}

Tender For Rate Contract For Supply And Fixing Of Various Electric Item Under The Jurisdiction Of City Division I Jodhpur, jodhpur-Rajasthan

Public Health And Engineering Department has published Tender For Rate Contract For Supply And Fixing Of Various Electric Item Under The Jurisdiction Of City Division I Jodhpur. Submission Date for this Tender is 30-04-2025. Electrical Products Tenders in jodhpur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

48807974
Tender For Rate Contract For Supply And Fixing Of Various Electric Item Under The Jurisdiction Of City Division I Jodhpur
Open Tender
NCB
Rajasthan
Jodhpur
30-04-2025

Tender Documents

Tender Details

Tender For Rate Contract For Supply And Fixing Of Various Electric Item Under The Jurisdiction Of City Division I Jodhpur - 1 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 2 Short point (up to 3 mtr.) 3 Medium point (up to 6 mtr.) 4 Long point(up to 10 mtr.) 5 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal,2 Nos10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 6 Short point (up to 3 mtr.) 7 Medium point (up to 6 mtr.) 8 Long point(up to 10 mtr.) 9 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 10 On board 11 Short point (up to 3 mtr.) 12 Medium point (up to 6 mtr.) 13 Long point(up to 10 mtr..) 14 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 15 1 x 1.5 sq.mm 16 2 x 1.5 sq.mm 17 3x 1.5 sq.mm 18 4 x 1.5 sq.mm 19 1 x 2.5 sq.mm 20 2 x 2.5 sq.mm 21 2 x 2.5 sq. mm. + 1x1.5sqmm 22 P/Laying ISI marked P.V.C. insulated submersible cable confirming to(IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen freefor less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,existing pipe / open trench / Cable tray / on surface including making connection etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 23 1.5 Sq.mm 3 core flat / Round 24 2.5 Sq.mm 3 core flat / Round 25 4.0 Sq.mm 3 core flat / Round 26 6.0 Sq.mm 3 core flat / Round 27 10.0 Sq.mm 3 core flat / Round 28 16.0 Sq.mm 3 core flat / Round 29 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 30 Single pole MCB (With B/C curve tripping Characteristics) 31 0.5 A to 5 A rating 32 6 A to 32 A rating 33 40 Arating 34 50/63 Arating 35 80 A rating 36 100 A rating 37 125 A rating 38 Double pole MCB(With B/C curve tripping Characteristics) 39 0.5 A to 5 A rating 40 6 A to 32 A rating 41 40 A rating 42 50/63 A rating 43 80 A rating 44 100 A rating 45 125 A rating 46 Triple pole MCB(With B/C curve trippingCharacteristics) 47 0.5A to 5 A rating 48 6 A to 32 A rating 49 40 A rating 50 50/63 A rating 51 80 A rating 52 100 A rating 53 125 A rating 54 Four pole MCB (With B/C curve tripping Characteristics) 55 0.5A to 5 A rating 56 6 A to 32 A rating 57 40 A rating 58 50/63 A rating 59 80 A rating 60 100 A rating 61 125 A rating 62 Providing & Fixing ofof 3/5 pin 6 amp. flush typenon modular socketmade out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 63 Providing & Fixing of3/6 pin 16 amp flush type non modular socketmade out from Industrial grade Polycarbonate or fire resistant ABS material, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 64 Providing & Fixing ofISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screws including making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 65 (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 66 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 67 Electrolytic grade Aluminium bus bar 6010 grade 68 Electrolytic grade (Cu-ETP) Tin Coated annealed copper bus bars IACS 100% grade 69 Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type(up to 500) V range Volt meter / Direct- Ammeter /CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracyas per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 70 Single Phase Ammeter 71 Single Phase Voltmeter 72 Three phase Ammeterwith Inbuilt Selector Switch 73 Three phase Voltmeter with Inbuilt Selector Switch 74 Three phase KWH Meter 75 Three phase KWH Meter Dual Source 76 Frequency Meter 77 Threephase AMP+HZ+PF+KW+KVA+K VAR+T. ENERGY +THD-I, THD-V & RUN HRS 78 Three phase AMP + HZ + PF + KW + KVA + KVAR + KVARH+KWH+DUAL ENERGY+ ENERGY+THD-I, THD-V & RUN HRS 79 Three phase with universal Auxiliary supply + AMP + HZ + PF + KW + KVA + KVAR + KVARH + KWH + DUAL ENERGY+ ENERGY+THD-I, THD-V & RUN HRS + MD with RS485 80 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 81 Ring type tape wound CT 82 C T Class 1, Ratio upto 150/5, Burden 5 VA 83 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 84 C T Class 1, Ratio 400/5 to 1200/5, Burden 15 VA 85 C T Class 1, Ratio 1600/5 to 3000/5, Burden 15 VA 86 C T Class 1, Ratio 3200/5 to 4000/5, Burden 15 VA 87 Resin cast wound type CT 88 C T Class 1, Ratio upto 150/5, Burden 5 VA 89 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 90 C T Class 1, Ratio 400/5 to 1200/5, Burden 15 VA 91 C T Class 1, Ratio 1600/5 to 3000/5, Burden 15 VA 92 C T Class 1, Ratio 3200/5 to 4000/5, Burden 15 VA 93 Providing & Fixing ofCam operated rotary (Auto/manual) switches on existing panel with 2 way and off position using high grade engineering materialto international standards with cam assemblyinsulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc.as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 10 AMP 95 16 Amp 96 32 AMP 97 63 AMP 98 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 99 Red/yellow/Green colour 100 Blue / white Colour 101 Providing & Fixing offlush head push button actuators IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV,including connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 102 Non luminous type 103 Luminous typeRed , Yellow, Green, Amber 104 Luminous typeBlue , white 105 Providing & Fixing of Electricalinsulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 /2006with one sideanti skid abberation marks and pasting the mat with synthetic rubber adhesive as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 106 3.3 KV,class A 2 mm thick with proof voltage 10 KV AC (rms) and Break Down Voltage 30 KV AC (rms) 107 11 KV,Class B 2.5 mm thick with proof voltage 22 KV AC (rms) and Break Down Voltage45 KV AC (rms) 108 33 KV,class C 3 mm thick with proof voltage 36 KV AC (rms) for3 min. and Break Down Voltage 65 KV AC (rms) 109 Providing & Fixing of self healing IP20 MPP type shunt capacitor (banks) conforming to IS:13340-41 /IEC :831-1&2 OR IEC : 60831-1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz, Operating loss less than 0.30 Watt per KVAR. Min over current capacity 1.8 times rated current & peak inrush current min. 300 times of rated current, llife expectancy greater than 100000hrs(temp class - 25 D)in 440 V/480 V Capacitor and for 525 V should life expectancy minimum 1,65,000 hrs (temp class - 25 D)including making connections, testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 110 Heavy dutyThree phase 440 V, 50 Hzcylindrical type capacitor (Bank) 111 Heavy dutyThree phase 480 V, 50 Hzcylindrical type capacitor (Bank) 112 Heavy dutyThree phase 525V, 50 Hzcylindrical typecapacitor (Bank) 113 Providing & Fixing ofAC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 114 3 pole Power contactorswith following AC 3 Rating 115 Up to 12 Amp 116 13 to 25 Amp 117 32 Amp. 118 40 Amp 119 50 Amp 120 70 Amp 121 80 Amp 122 95 Amp 123 140Amp 124 185 Amp 125 250 Amp 126 300 Amp 127 400 Amp 128 550 Amp 129 630 Amp 130 4 pole Power contactorswith following AC 1 Rating 131 16 Amp. 132 25/32 Amp. 133 40 Amp 134 50 Amp 135 63 Amp 136 100 Amp 137 160 Amp 138 200 Amp 139 250 Amp 140 325 Amp 141 400 Amp 142 500 Amp 143 600 Amp 144 700 Amp 145 800 Amp 146 Providing & Fixing ofthermal over load relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 147 Up to 14 Amp 148 14 to 23 Amp 149 20 to 33 Amp 150 24 to 40 Amp 151 36 to 60 Amp 152 45 to 75 Amp 153 66 to 110 Amp 154 P & F of 240 / 415 V Electronic ON - OFF Timer 3 -30 Sec / 12 - 120 Sec including making Connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 155 Providing & Fixing of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1 and 60730-2-7 etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 156 One day reserve (Analog type ) 157 One day & week reserve (Analog type ) 158 One day & week reserve (digital type ) 159 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 160 3 pole MCCB With Thermal Magnetic release 161 up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting 162 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 163 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 164 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 165 200 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 166 250 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 167 250 Amp , 35 kA, adjustable O/L & adjustable S/C setting, 168 400 Amp , 35 kA, adjustable O/L & adjustable S/C setting, 169 630 Amp , 50 kA, adjustable O/L & adjustable S/C setting, 170 800 Amp , 50 kA, adjustable O/L & adjustable S/C setting, 171 3 pole MCCB With Microprocessor based release with adjustable O/L &S/C setting with Inbuilt Instantaneous and Ground fault Protection. 172 250 Amp , 25 Ka 173 400 Amp , 35 kA 174 630 Amp , 50 kA 175 800 Amp , 50 kA 176 4 pole MCCB With Thermal Magnetic release 177 up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting 178 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 179 125 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 180 160 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 181 200 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 182 250 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 183 250 Amp , 35 kA, adjustable O/L & adjustable S/C setting, 184 400 Amp , 35 kA, adjustable O/L & adjustable S/C setting, 185 630 Amp , 50 kA, adjustable O/L & adjustable S/C setting, 186 800 Amp , 50 kA, adjustable O/L & adjustable S/C setting, 187 Providing & Fixing of ISO certified company made 240/415 V porcelain kitkat fuse (/HBC type) as per PWD specificationfor electrical Works conforming to IS:2086,1983 on existing board/ sheet including making connections with lugs, testing etc. as required .Appropriate type test certificate / OEM test report shall be submitted . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 188 16 A ,240 V 189 16 A ,415 V 190 32 A ,240 V 191 32 A ,415 V 192 63 A , 415 V 193 100 A ,415 V 194 200 A , 415 V 195 320 A , 415 V 196 Providing & Fixing of ISO certified company made bolted type/ Din type HBC (High breaking capacity) fuse links of 80 KA breaking capacity,as per PWD specificationfor electrical Works conforming to IS:13703 in the existing fuse base, fuse switch unit etc. of the following type and rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 197 Cylindrical Fuse Link 198 2 A to 32 A 199 40 A 200 50 A 201 63A 202 Offset tag type 203 2 A to 20 A 204 25 A to 32 A 205 35 A to 63 A 206 80 A to 125 A 207 Central tag type 208 80 A to 125 A 209 160 A to 200 A 210 250 A to 315 A 211 400 A to 500 A 212 630 A 213 Din (knife type) type 214 63 A to 125 A Size 000 215 63 A to 160 A Size 00 216 80 A to 200 A Size 0 217 125 A to 315 A Size 1 218 200 A to 400 A Size 2 219 315A to 800 A Size 3 220 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 221 4.0 Sq. mm 222 2 core 223 3 core 224 4 core 225 6.0 sq.mm 226 2 core 227 3 core 228 4 core 229 10.0 sq.mm 230 2 core 231 3 core 232 4 core 233 16.0 sq.mm 234 2 core 235 3 core 236 4 core 237 25.0 sq.mm 238 2 core 239 3 core 240 3.5 core 241 35.0 sq.mm 242 2 core 243 3 core 244 3.5 core 245 50.0 sq.mm 246 2 core 247 3 core 248 3.5 core 249 70.0 sq.mm 250 1 core 251 2 core 252 3 core 253 3.5 core 254 95.0 sq.mm 255 1 core 256 3.5 core 257 120.0 sq.mm 258 1 core 259 3.5 core 260 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArmouredCoppercable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withelectrolytic gradeCopper made of copper rodsconfirming to IS 613-1964, of purity >99.7 %, round / flat strip armouring, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie)includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure A attached with this BSR 261 1.5 sq.mm 262 2 core 263 3 core 264 4 core 265 6 core 266 8 core 267 10 core 268 12 core 269 2.5 sq.mm 270 2 core 271 3 core 272 4 core 273 6 core 274 8 core 275 10 core 276 12 core 277 4.0 sq.mm 278 2 core 279 3 core 280 4 core 281 6.0 sq.mm 282 2 core 283 3 core 284 4 core 285 10.0 sq.mm 286 2 core 287 3 core 288 4 core 289 16.0 sq.mm 290 1 core 291 2 core 292 3 core 293 4 core 294 25.0 sq.mm 295 1 core 296 2 core 297 3 core 298 4 core 299 35.0 sq.mm 300 1 core 301 2 core 302 3 core 303 4 core 304 50.0 sq.mm 305 1 core 306 2 core 307 3 core 308 4 core 309 Supplying and makingend termination with heavy aluminiumlugs ( Pin / ring type )confirming to IS 8309 -1993 & IS 8337-1976 duly crimped with crimping tool, PVC tape etc of following size.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 310 1.5 sq.mm 311 2.5 sq.mm 312 4.0 sq.mm 313 6.0 sq.mm 314 10.0 sq.mm 315 16.0 sq.mm 316 25.0 sq.mm 317 35.0 sq.mm 318 50.0 sq.mm 319 70.0 sq.mm 320 95.0 sq.mm 321 120.0 sq.mm 322 150.0 sq.mm 323 185.0 sq.mm 324 240.0 sq.mm 325 300.0 sq.mm 326 400.0 sq.mm 327 500.0 sq.mm 328 630.0 sq.mm 329 800.0 sq.mm 330 1000.0 sq.mm 331 Supplying and makingend termination with heavy duty Copper lugs ( ANY type ) confirming toIS 8337 -1976 duly crimped with crimping tool, PVC tape etc of following size.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 332 1.5 sq.mm 333 2.5 sq.mm 334 4.0 sq.mm 335 6.0 sq.mm 336 10.0 sq.mm 337 16.0 sq.mm 338 25.0 sq.mm 339 35.0 sq.mm 340 50.0 sq.mm 341 70.0 sq.mm 342 95.0 sq.mm 343 120.0 sq.mm 344 Providing & Laying XLPE insulated three core ArmouredAluminiumcable for working voltage 11 K.V.(E) confirming IS :7098 P - 2withH4- Grade electrolyticaluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 345 3 core 95.0 sq.mm 346 3 core 120.0 sq.mm 347 3 core 150.0 sq.mm 348 3 core 185.0 sq.mm 349 3 core 240.0 sq.mm 350 3 core 300.0 sq.mm 351 late Earthing as per IS:3043 withcopper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying3 mtr. below the ground level with 20mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 352 Making of hole in wall (brick/stone) of required and placing NP-2 RCC pipe ring of required size for housing exhaust fan and making good the same, with cement plaster required of following size. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 353 up to 457 mm size 354 more than 457 mm & up to 610 mm 355 Supply & Fixing of phenolic laminated boardof 6.4 mm thick forfresh air fan/exhaust fan up to size of 300 mm onexisting window frame including cost of board, cutting of hole , Nut bolts etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 356 Installation , testing and Commissioning of ceiling fan (any size) including wiring the down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 357 with regulator 358 without regulator 359 Providing & Fixing ofof BLDC Technologyventilating fans , single phase with PVC impeller, ABS body, Double Ball bearing, automatic back lower shutterincluding making connection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 360 150 mm sweep with Min. Air delivery 350 cmh, 2000 RPM 361 200 mm sweep with Min. Air delivery 800 cmh, 1600 RPM 362 250 mm sweep with Min. Air delivery 1150 cmh, 1300 RPM 363 Providing & Fixing ofof Double ball bearing, copper wounded capacitor startsingle phase metallicblade fresh air fan, in existing opening including cost of hardware , flexible 3 core copper conductor ,making connections, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 364 225 mm sweep 365 300 mm sweep 366 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminiumhousing with in built driver, System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 367 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 368 570mm (+/-10%) batten with min. lumen output 1000 lm 369 Providing & Fixing of IP65 IK08 rated Integrated High power LED ( each LED between 3 to 5 watt power with secondary lencs on each LED) Highbaylight fixture made from Pressure Die Cast Aluminium housing, toughned glass diffuser, potteddriver, Eye bolt for mounting,system lumen efficacy ≥140 lm/Watt output , THD < 10% ,p.f.≥0.95,CRI >80 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. surge protection 4 KV inbuilt & 10 KV external inside fixture.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 370 Minimum lumen output 10000 lm 371 Minimum lumen output 14000 lm 372 Minimum lumen output 16500 lm 373 Providing & Fixing of Suspended mountingIP66 IK08 rated Integrated High power LED Wellglasslight fixture made from Pressure Die Cast Aluminium housing, potted driver, Eye bolt for mounting, PC clear / Opal Diffuser, system lumen efficacy ≥120 lm/Watt output , THD < 10% ,p.f.≥0.95,CRI >70 , life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. surge protection 4 KV . OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 374 Minimum lumen output 3500 lm 375 Minimum lumen output 4800 lm 376 Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulbin existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI >70,minimum life time of minimum25000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure A attacheded with this BSR. 377 2/3 watt 378 6/7 watt 379 9 watt 380 15 watt 381 18/20 watt 382 Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 383 Single arm overhang 384 Double arm overhang 385 Supply and erection ofGalvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) Swaged tubular pole conforming to IS: 2713-1980 (part I to II) with galvanised base plate, The pole shall be made from steel tube & Pipe (IS:1141, Fe 410) including excavation of the pit and filling the same with C.C. of M-20 grade (1:1.5:3) from base plate to 50 cm above ground level, with the help of steel frame not less than 40 cm dia up to 114.3mm outer dia and 50 cm beyond 114.3mm outer dia around the pole. Duly finished with cement plaster, earthing terminals, cable entry with 32 mm dia. B class GI cable sleeves complete as required. of following height & designation.( See Table P - 02 forspecs. ) All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 386 7.5 Mtr. ( 410 SP - 5 ) 387 8.5 Mtr. ( 410 SP - 17 ) 388 9.0 Mtr. ( 410 SP - 28 ) 389 10 Mtr.( 410 SP - 42 ) 390 Providing & Fixing of Street light bracket made out from following size of B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 391 20 mm Dia 392 25 mm Dia 393 32 mm Dia 394 40 mm Dia 395 Providing & Fixing ofIK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles,of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R numberhaving efficiency more than 85 % and in compliance to BIS certified and Trade markcertificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10%, driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K±355K.Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 396 High Power LED Flood Light Minimum lumen output 3700 lm 397 High Power LED Flood Light Minimum lumen output 6200 lm 398 High Power LED Flood Light Minimum lumen output 8700 lm 399 High Power LED Flood Light Minimum lumen output 10000 lm 400 High Power LED Flood Light Minimum lumen output 12400 lm 401 High Power LED Flood Light Minimum lumen output 14800 lm 402 High Power LED Flood Light Minimum lumen output 18650 lm 403 High Power LED Flood Light Minimum lumen output 22400 lm 404 High Power LED Flood Light Minimum lumen output 25000 lm 405 High Power LED Flood Light Minimum lumen output 30000 lm 406 High Power LED Flood Light Minimum lumen output 37500 lm 407 High Power LED Flood Light Minimum lumen output 43750 lm 408 Providing and fixing of fuse box size 250(H) x 200(W) x 150(D) mmfabricated of 1.6mm MS sheet with hinged cover, dust and vermin proof, rubber gasket, locking arrangement, duly holded with 2 nos pole clamps of 20 mm x 3 mm flat with nut and bolts, complete with anticorrosive treatment, finished with two coat of approved enamel paint. The box shall be provided with 2 / 4 nos copper bus bar 125 x 20 x 3 mm with brass screws suitable supports,earth terminal, inter connection, knock outs for 20 / 25 mm cable gland, 1 no. 6 Amp MCBcomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .

Key Value

Document Fees
INR 500 /-
EMD
INR 16000.0 /-
Tender Value
INR 8 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail