}

Tender For Instrumentation, Hazira-Gujarat

Arcelor Mittal Nippon Steel India Limited has published Tender For Instrumentation. Submission Date for this Tender is 29-04-2025. RF Transmitter Tenders in Hazira Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

48799114
Tender For Instrumentation
Open Tender
Indian
Gujarat
Hazira
29-04-2025

Tender Documents

Tender Details

Tender For Instrumentation 28040471 0001 0001 300864167 TRNSMTR,PR,GP,0-5BAR,HART,24VDC,THREADE Technical Details Name : Harnish Desai Contact : Email : HARNISHKUMAR.DESAI@AMNS.IN 6 NO TRANSMITTER,PRESSURE TYPE:GAUGE PRESSURE , RANGE:0-5 BAR OUTPUT SIGNAL:4-20 MA WITH DIGITAL SIGNAL BASED ON HART POWER SUPPLY:24 VDC , PROCESS CONNECTION:THREADED - 1/2” NPT (F) ELECTRICAL CONNECTION:2 WIRE , SERVICE:LIQUID COMMUNICATION PROTOCOL:4-20 MA WITH DIGITAL SIGNAL BASED ON HART Item Details : * SCOPE :- The specification covers design, engineering, manufacturing, inspection, packing, despatch, supervision of erection, testing at site and commissioning of the instruments for central Chilled Water Plant. Drawing/Document shall be provided by successful Tenderer as per Clause No. 4.10.1.5 of this specification. Checking of calibration and pre-installation testing of all instrumentation items prior to installation to ensure that each individu al item are functionally correct and correctly calibrated and programmed. Commissioning and Performance test of all instruments shall be in Tenderer’s scope. Any item or accessories not included in this specification, but essential for proper functioning of the offered system shall be deemed to be included in the scope of the Tenderer. The design, manufacture and testing of the various equipment covered in this specification shall comply with the latest editions of the relevant Indian standards, and codes of practices or in the absence of the same, relevant international standards, codes and regulations. All equipment supplied shall also comply with the statutory requirement of the Government of India, State government (Gujarat) where instruments are to be installed and the latest revision of the International Instrumentation Rules. Factory Test: All necessary tests shall be made at the Manufacturers works, before despatch to determine whether the instruments offered conform to the relevant standards and specifications. Tests shall be conducted with the actual service conditions of site simulated as far as possible and with all external components and fittings in place, which are likely to affect the performance. Tenderer shall include and provide for in their tender all facilities, which shall enable inspection by the Purchaser for all supply items. The tests to be carried out shall include type tests as well as routine tests in accordance with standard practice Design Basis : Design Basis No. H019-MND-PGUH-GEN-I-DBS-001 shall be followed for selection of instrumentation system. * Annex-1 Datasheet of Pressure Transmitter General Tag No. Refer Taglist-1 Service Refer Taglist-1 P <(>&<)> ID No. Refer Taglist-1 Line Size Refer Taglist-1 Hazardous Area classification Safe area Mounting 2-inch pipe mounting Transmitter Fluid Refer Taglist-1 Oper. Pressure Normal Refer Taglist-1 Temperature Normal Refer Taglist-1 Oper. Spec. Gravity - Instrument Type Sensor Gauge Pressure Capacitive Measuring Diaphragm Impedance value 316L SS 600 ohms Process Conn 1/2 NPT (F) through manifold Output Signal Accuracy 4-20 mA, HART ± 0.1% of span Power Supply Electrical connection 24 VDC Loop Powered 1/2 NPT(F) Span <(>&<)> Zero Adjustment screws for span <(>&<)> zero Integral Indicator LC Display In-Built Lightning Protection - Enclosure Enclosure class Die Cast Al IP-65 Wetted Parts SS316 Accessories 2 Way Manifold 1/2 NPT(F) Material Vendors scope SS316 Cable Gland Material Vendors scope VTS Purchase Manufacturer VTS Model VTS * Taglist : Pressure Transmitter Sl. no. Tag no. Service LtiLi Page 2 of 12 ArcelorMittal Nippon Steel India Pvt Ltd AM/NS HAZIRA PLANT 27th KM, Surat-Hazira Road,,HAZIRA,394270,Gujarat,India GSTIN 24AAACE1741P1ZN PAN AAACE1741P CIN U27100GJ1976FTC013787 Request for Quotation Number 6000132691 Date 21.04.2025 Submission Date 29.04.2025 Coll Req No AMNS deals with OEMs directly. We are very well equipped in every way to import / buy our goods directly from OEMs from any part of the world in a professional manner. We also use the vast global networks of our parent companies where necessary. We do not welcome any contact from intermediaries or Indian Agents of vendors. We assure all OEMs that you do not need to engage anyone to manage your transactions with us.Kindly respond to our RFQs and deal with our officials directly without involving any agents or intermediaries. Offers of vendors who insist on involving intermediaries in dealings with us could be disqualified. Contact for this RFQ Ms. swati joshi Contact Email SWATI.JOSHI@AMNS.IN MATERIALS / SERVICES Please acknowledge receipt of the RFQ And provide your best quote for below given RFQ details. SR. No PR No. PR Item RFQ Item Material / Service No. Quantity UOM Detail Description Other Details 2 28040471 0002 0002 300893139 TRNSMTR,PR,GP,0-12BAR,HART,24VDC,THREAD Technical Details Name : Harnish Desai Contact : Email : HARNISHKUMAR.DESAI@AMNS.IN 6 NO TRANSMITTER,PRESSURE TYPE:GAUGE PRESSURE , RANGE:0-12 BAR OUTPUT SIGNAL:4-20 MA WITH DIGITAL SIGNAL BASED ON HART POWER SUPPLY:24 VDC , PROCESS CONNECTION:THREADED - 1/2 INCH NPT (F) SERVICE:LIQUID Item Details : * SCOPE :- The specification covers design, engineering, manufacturing, inspection, packing, despatch, supervision of erection, testing at site and commissioning of the instruments for central Chilled Water Plant. Drawing/Document shall be provided by successful Tenderer as per Clause No. 4.10.1.5 of this specification. Checking of calibration and pre-installation testing of all instrumentation items prior to installation to ensure that each individu al item are functionally correct and correctly calibrated and programmed. Commissioning and Performance test of all instruments shall be in Tenderer’s scope. Any item or accessories not included in this specification, but essential for proper functioning of the offered system shall be deemed to be included in the scope of the Tenderer. The design, manufacture and testing of the various equipment covered in this specification shall comply with the latest editions of the relevant Indian standards, and codes of practices or in the absence of the same, relevant international standards, codes and regulations. All equipment supplied shall also comply with the statutory requirement of the Government of India, State government (Gujarat) where instruments are to be installed and the latest revision of the International Instrumentation Rules. Factory Test: All necessary tests shall be made at the Manufacturers works, before despatch to determine whether the instruments offered conform to the relevant standards and specifications. Tests shall be conducted with the actual service conditions of site simulated as far as possible and with all external components and fittings in place, which are likely to affect the performance. Tenderer shall include and provide for in their tender all facilities, which shall enable inspection by the Purchaser for all supply items. The tests to be carried out shall include type tests as well as routine tests in accordance with standard practice Design Basis : Design Basis No. H019-MND-PGUH-GEN-I-DBS-001 shall be followed for selection of instrumentation system. * Annex-1 Datasheet of Pressure Transmitter General Tag No. Refer Taglist-1 Service Refer Taglist-1 P <(>&<)> ID No. Refer Taglist-1 Line Size Refer Taglist-1 Hazardous Area classification Safe area Mounting 2-inch pipe mounting Transmitter Fluid Refer Taglist-1 Oper. Pressure Normal Refer Taglist-1 Temperature Normal Refer Taglist-1 Oper. Spec. Gravity - Instrument Type Sensor Gauge Pressure Capacitive Measuring Diaphragm Impedance value 316L SS 600 ohms Process Conn 1/2 NPT (F) through manifold Output Signal Accuracy 4-20 mA, HART ± 0.1% of span Power Supply Electrical connection 24 VDC Loop Powered 1/2 NPT(F) Span <(>&<)> Zero Adjustment screws for span <(>&<)> zero Integral Indicator LC Display In-Built Lightning Protection - Enclosure Enclosure class Die Cast Al IP-65 Wetted Parts SS316 Accessories 2 Way Manifold 1/2 NPT(F) Material Vendors scope SS316 Cable Gland Material Vendors scope VTS Purchase Manufacturer VTS Model VTS * Taglist : Pressure Transmitter Sl. no. Tag no. Service Location Line size Operating temp. (° C) Operating pressure (bar G) Instrument range P<(>&<)>ID 116PIT1023CliWCliWSlCHdDN1200 Page 3 of 12 ArcelorMittal Nippon Steel India Pvt Ltd AM/NS HAZIRA PLANT 27th KM, Surat-Hazira Road,,HAZIRA,394270,Gujarat,India GSTIN 24AAACE1741P1ZN PAN AAACE1741P CIN U27100GJ1976FTC013787 Request for Quotation Number 6000132691 Date 21.04.2025 Submission Date 29.04.2025 Coll Req No AMNS deals with OEMs directly. We are very well equipped in every way to import / buy our goods directly from OEMs from any part of the world in a professional manner. We also use the vast global networks of our parent companies where necessary. We do not welcome any contact from intermediaries or Indian Agents of vendors. We assure all OEMs that you do not need to engage anyone to manage your transactions with us.Kindly respond to our RFQs and deal with our officials directly without involving any agents or intermediaries. Offers of vendors who insist on involving intermediaries in dealings with us could be disqualified. Contact for this RFQ Ms. swati joshi Contact Email SWATI.JOSHI@AMNS.IN MATERIALS / SERVICES Please acknowledge receipt of the RFQ And provide your best quote for below given RFQ details. SR. No PR No. PR Item RFQ Item Material / Service No. Quantity UOM Detail Description Other Details 3 28040471 0003 0003 300850272 TRNSMTR,PR,GP,0-1BAR,HART,24VDC,1/2NPT Technical Details Name : Harnish Desai Contact : Email : HARNISHKUMAR.DESAI@AMNS.IN 1 NO TRANSMITTER,PRESSURE TYPE:GAUGE PRESSURE , PROCESS CONNECTION:1/2NPT MALE OUTPUT SIGNAL:4-20 MA WITH DIGITAL SIGNAL BASED ON HART POWER SUPPLY:24 VDC , RANGE:0-1 BAR Item Details : * SCOPE :- The specification covers design, engineering, manufacturing, inspection, packing, despatch, supervision of erection, testing at site and commissioning of the instruments for central Chilled Water Plant. Drawing/Document shall be provided by successful Tenderer as per Clause No. 4.10.1.5 of this specification. Checking of calibration and pre-installation testing of all instrumentation items prior to installation to ensure that each individu al item are functionally correct and correctly calibrated and programmed. Commissioning and Performance test of all instruments shall be in Tenderer’s scope. Any item or accessories not included in this specification, but essential for proper functioning of the offered system shall be deemed to be included in the scope of the Tenderer. The design, manufacture and testing of the various equipment covered in this specification shall comply with the latest editions of the relevant Indian standards, and codes of practices or in the absence of the same, relevant international standards, codes and regulations. All equipment supplied shall also comply with the statutory requirement of the Government of India, State government (Gujarat) where instruments are to be installed and the latest revision of the International Instrumentation Rules. Factory Test: All necessary tests shall be made at the Manufacturers works, before despatch to determine whether the instruments offered conform to the relevant standards and specifications. Tests shall be conducted with the actual service conditions of site simulated as far as possible and with all external components and fittings in place, which are likely to affect the performance. Tenderer shall include and provide for in their tender all facilities, which shall enable inspection by the Purchaser for all supply items. The tests to be carried out shall include type tests as well as routine tests in accordance with standard practice Design Basis : Design Basis No. H019-MND-PGUH-GEN-I-DBS-001 shall be followed for selection of instrumentation system. * Annex-1 Datasheet of Pressure Transmitter General Tag No. Refer Taglist-1 Service Refer Taglist-1 P <(>&<)> ID No. Refer Taglist-1 Line Size Refer Taglist-1 Hazardous Area classification Safe area Mounting 2-inch pipe mounting Transmitter Fluid Refer Taglist-1 Oper. Pressure Normal Refer Taglist-1 Temperature Normal Refer Taglist-1 Oper. Spec. Gravity - Instrument Type Sensor Gauge Pressure Capacitive Measuring Diaphragm Impedance value 316L SS 600 ohms Process Conn 1/2 NPT (F) through manifold Output Signal Accuracy 4-20 mA, HART ± 0.1% of span Power Supply Electrical connection 24 VDC Loop Powered 1/2 NPT(F) Span <(>&<)> Zero Adjustment screws for span <(>&<)> zero Integral Indicator LC Display In-Built Lightning Protection - Enclosure Enclosure class Die Cast Al IP-65 Wetted Parts SS316 Accessories 2 Way Manifold 1/2 NPT(F) Material Vendors scope SS316 Cable Gland Material Vendors scope VTS Purchase Manufacturer VTS Model VTS * Taglist : Pressure Transmitter Sl. no. Tag no. Service Location Line size Operating temp. (° C) Operating pressure (bar G) Instrument range P<(>&<)>ID 116PIT1023CliWCliWSlCHdDN1200 Page 4 of 12 ArcelorMittal Nippon Steel India Pvt Ltd AM/NS HAZIRA PLANT 27th KM, Surat-Hazira Road,,HAZIRA,394270,Gujarat,India GSTIN 24AAACE1741P1ZN PAN AAACE1741P CIN U27100GJ1976FTC013787 Request for Quotation Number 6000132691 Date 21.04.2025 Submission Date 29.04.2025 Coll Req No AMNS deals with OEMs directly. We are very well equipped in every way to import / buy our goods directly from OEMs from any part of the world in a professional manner. We also use the vast global networks of our parent companies where necessary. We do not welcome any contact from intermediaries or Indian Agents of vendors. We assure all OEMs that you do not need to engage anyone to manage your transactions with us.Kindly respond to our RFQs and deal with our officials directly without involving any agents or intermediaries. Offers of vendors who insist on involving intermediaries in dealings with us could be disqualified. Contact for this RFQ Ms. swati joshi Contact Email SWATI.JOSHI@AMNS.IN MATERIALS / SERVICES Please acknowledge receipt of the RFQ And provide your best quote for below given RFQ details. SR. No PR No. PR Item RFQ Item Material / Service No. Quantity UOM Detail Description Other Details 4 28040471 0004 0004 300884209 TRNSMTR,PR,GP,0-10BAR,HART,24VDC,THREAD Technical Details Name : Harnish Desai Contact : Email : HARNISHKUMAR.DESAI@AMNS.IN 1 NO TRANSMITTER,PRESSURE TYPE:GAUGE PRESSURE , RANGE:0-10 BAR OUTPUT SIGNAL:4-20 MA WITH DIGITAL SIGNAL BASED ON HART POWER SUPPLY:24 VDC , PROCESS CONNECTION:THREADED - 1/2 INCH NPT (F) Item Details : * SCOPE :- The specification covers design, engineering, manufacturing, inspection, packing, despatch, supervision of erection, testing at site and commissioning of the instruments for central Chilled Water Plant. Drawing/Document shall be provided by successful Tenderer as per Clause No. 4.10.1.5 of this specification. Checking of calibration and pre-installation testing of all instrumentation items prior to installation to ensure that each individu al item are functionally correct and correctly calibrated and programmed. Commissioning and Performance test of all instruments shall be in Tenderer’s scope. Any item or accessories not included in this specification, but essential for proper functioning of the offered system shall be deemed to be included in the scope of the Tenderer. The design, manufacture and testing of the various equipment covered in this specification shall comply with the latest editions of the relevant Indian standards, and codes of practices or in the absence of the same, relevant international standards, codes and regulations. All equipment supplied shall also comply with the statutory requirement of the Government of India, State government (Gujarat) where instruments are to be installed and the latest revision of the International Instrumentation Rules. Factory Test: All necessary tests shall be made at the Manufacturers works, before despatch to determine whether the instruments offered conform to the relevant standards and specifications. Tests shall be conducted with the actual service conditions of site simulated as far as possible and with all external components and fittings in place, which are likely to affect the performance. Tenderer shall include and provide for in their tender all facilities, which shall enable inspection by the Purchaser for all supply items. The tests to be carried out shall include type tests as well as routine tests in accordance with standard practice Design Basis : Design Basis No. H019-MND-PGUH-GEN-I-DBS-001 shall be followed for selection of instrumentation system. * Annex-1 Datasheet of Pressure Transmitter General Tag No. Refer Taglist-1 Service Refer Taglist-1 P <(>&<)> ID No. Refer Taglist-1 Line Size Refer Taglist-1 Hazardous Area classification Safe area Mounting 2-inch pipe mounting Transmitter Fluid Refer Taglist-1 Oper. Pressure Normal Refer Taglist-1 Temperature Normal Refer Taglist-1 Oper. Spec. Gravity - Instrument Type Sensor Gauge Pressure Capacitive Measuring Diaphragm Impedance value 316L SS 600 ohms Process Conn 1/2 NPT (F) through manifold Output Signal Accuracy 4-20 mA, HART ± 0.1% of span Power Supply Electrical connection 24 VDC Loop Powered 1/2 NPT(F) Span <(>&<)> Zero Adjustment screws for span <(>&<)> zero Integral Indicator LC Display In-Built Lightning Protection - Enclosure Enclosure class Die Cast Al IP-65 Wetted Parts SS316 Accessories 2 Way Manifold 1/2 NPT(F) Material Vendors scope SS316 Cable Gland Material Vendors scope VTS Purchase Manufacturer VTS Model VTS * Taglist : Pressure Transmitter Sl. no. Tag no. Service Location Line size Operating temp. (° C) Operating pressure (bar G) Instrument range P<(>&<)>ID 116PIT1023CliWCliWSlCHdDN1200 Page 5 of 12 ArcelorMittal Nippon Steel India Pvt Ltd AM/NS HAZIRA PLANT 27th KM, Surat-Hazira Road,,HAZIRA,394270,Gujarat,India GSTIN 24AAACE1741P1ZN PAN AAACE1741P CIN U27100GJ1976FTC013787 Request for Quotation Number 6000132691 Date 21.04.2025 Submission Date 29.04.2025 Coll Req No AMNS deals with OEMs directly. We are very well equipped in every way to import / buy our goods directly from OEMs from any part of the world in a professional manner. We also use the vast global networks of our parent companies where necessary. We do not welcome any contact from intermediaries or Indian Agents of vendors. We assure all OEMs that you do not need to engage anyone to manage your transactions with us.Kindly respond to our RFQs and deal with our officials directly without involving any agents or intermediaries. Offers of vendors who insist on involving intermediaries in dealings with us could be disqualified. Contact for this RFQ Ms. swati joshi Contact Email SWATI.JOSHI@AMNS.IN MATERIALS / SERVICES Please acknowledge receipt of the RFQ And provide your best quote for below given RFQ details. SR. No PR No. PR Item RFQ Item Material / Service No. Quantity UOM Detail Description Other Details 5 28040471 0007 0005 300881878 TRNSMTR,FLOW,US,0-45M3/H,200DN Technical Details Name : Harnish Desai Contact : Email : HARNISHKUMAR.DESAI@AMNS.IN 2 NO TRANSMITTER,FLOW TYPE:ULTRASONIC , INPUT RANGE:0-45 M3/H OUTPUT RANGE:ANALOG 0-20 MA OR 4-20 MA , SIZE AND CONNECTION:200 DN COMMUNICATION PROTOCOL:4-20 MA WITH DIGITAL SIGNAL BASED ON HART Item Details : * SCOPE :- The specification covers design, engineering, manufacturing, inspection, packing, despatch, supervision of erection, testing at site and commissioning of the instruments for central Chilled Water Plant. Drawing/Document shall be provided by successful Tenderer as per Clause No. 4.10.1.5 of this specification. Checking of calibration and pre-installation testing of all instrumentation items prior to installation to ensure that each individu al item are functionally correct and correctly calibrated and programmed. Commissioning and Performance test of all instruments shall be in Tenderer’s scope. Any item or accessories not included in this specification, but essential for proper functioning of the offered system shall be deemed to be included in the scope of the Tenderer. The design, manufacture and testing of the various equipment covered in this specification shall comply with the latest editions of the relevant Indian standards, and codes of practices or in the absence of the same, relevant international standards, codes and regulations. All equipment supplied shall also comply with the statutory requirement of the Government of India, State government (Gujarat) where instruments are to be installed and the latest revision of the International Instrumentation Rules. Factory Test: All necessary tests shall be made at the Manufacturers works, before despatch to determine whether the instruments offered conform to the relevant standards and specifications. Tests shall be conducted with the actual service conditions of site simulated as far as possible and with all external components and fittings in place, which are likely to affect the performance. Tenderer shall include and provide for in their tender all facilities, which shall enable inspection by the Purchaser for all supply items. The tests to be carried out shall include type tests as well as routine tests in accordance with standard practice Design Basis : Design Basis No. H019-MND-PGUH-GEN-I-DBS-001 shall be followed for selection of instrumentation system. * ANNEXURE-2 - DATASHEET OF ULTRASONIC FLOW TRANSMITTER General Tag No. Refer Taglist-2 Service Refer Taglist-2 Location Refer Taglist-2 P <(>&<)> ID No. Refer Taglist-2 Area Classification Safe Area Process Conditions Fluid Refer Taglist-2 Operating Pressure Refer Taglist-2 Flow Measurement Range Refer Taglist-2 Operating Temperature Refer Taglist-2 Sensor Type Ultrasonic, clamp-on sensors with coupling pads MOC SS316L Mounting style Fixed retaining nut Type sensor fastening Strapping band Transmitter Output Signal Enclosure Class 4-20 mA HART IP-65 Accuracy ± 2% on FSD Power Supply Electrical connection 85-250 V AC 4 wire, Screw terminal Cable Entry No. of cable entry 1/2 NPT(F) 2 Electronics Enclosure Powder-coated die-cast aluminum Local Display No. of lines LC Display 2 Operating Element Push buttons Mounting Pipe mounting Sensor Cable Special shielded cable Sensor Cable Length 10 m Cable Cover Material PVC Conduit for Cable Vendor’s Scope Accessories Sensor Housing Material VTS SS304 Strapping Bands Material VTS SS304 Transmitter installation accessories Material Vendor’s scope VTS Cable Gland Material 2 nos. ½ NPT(F) VTS Purchase Manufacturer VTS Model VTS Page 6 of 12 ArcelorMittal Nippon Steel India Pvt Ltd AM/NS HAZIRA PLANT 27th KM, Surat-Hazira Road,,HAZIRA,394270,Gujarat,India GSTIN 24AAACE1741P1ZN PAN AAACE1741P CIN U27100GJ1976FTC013787 Request for Quotation Number 6000132691 Date 21.04.2025 Submission Date 29.04.2025 Coll Req No AMNS deals with OEMs directly. We are very well equipped in every way to import / buy our goods directly from OEMs from any part of the world in a professional manner. We also use the vast global networks of our parent companies where necessary. We do not welcome any contact from intermediaries or Indian Agents of vendors. We assure all OEMs that you do not need to engage anyone to manage your transactions with us.Kindly respond to our RFQs and deal with our officials directly without involving any agents or intermediaries. Offers of vendors who insist on involving intermediaries in dealings with us could be disqualified. Contact for this RFQ Ms. swati joshi Contact Email SWATI.JOSHI@AMNS.IN MATERIALS / SERVICES Please acknowledge receipt of the RFQ And provide your best quote for below given RFQ details. SR. No PR No. PR Item RFQ Item Material / Service No. Quantity UOM Detail Description Other Details 6 28040471 0008 0006 300940649 TRNSMTR,LVL,DP,-6000TO0MM,THRD Technical Details Name : Harnish Desai Contact : Email : HARNISHKUMAR.DESAI@AMNS.IN 1 NO TRANSMITTER,LEVEL TYPE:DIFFERENTIAL PRESSURE , MEASURING RANGE:-6000 TO 0 MM SIZE AND CONNECTION:1/2 INCH NPT F THROUGH MANIFOLD , POWER SUPPLY:24VDC COMMUNICATION PROTOCOL:HART ELECTRICAL CONNECTION:2 CABLE GLAND M20X1,5 , SERVICE:LIQUID MOUNTING:THREADED Item Details : * SCOPE :- The specification covers design, engineering, manufacturing, inspection, packing, despatch, supervision of erection, testing at site and commissioning of the instruments for central Chilled Water Plant. Drawing/Document shall be provided by successful Tenderer as per Clause No. 4.10.1.5 of this specification. Checking of calibration and pre-installation testing of all instrumentation items prior to installation to ensure that each individu al item are functionally correct and correctly calibrated and programmed. Commissioning and Performance test of all instruments shall be in Tenderer’s scope. Any item or accessories not included in this specification, but essential for proper functioning of the offered system shall be deemed to be included in the scope of the Tenderer. The design, manufacture and testing of the various equipment covered in this specification shall comply with the latest editions of the relevant Indian standards, and codes of practices or in the absence of the same, relevant international standards, codes and regulations. All equipment supplied shall also comply with the statutory requirement of the Government of India, State government (Gujarat) where instruments are to be installed and the latest revision of the International Instrumentation Rules. Factory Test: All necessary tests shall be made at the Manufacturers works, before despatch to determine whether the instruments offered conform to the relevant standards and specifications. Tests shall be conducted with the actual service conditions of site simulated as far as possible and with all external components and fittings in place, which are likely to affect the performance. Tenderer shall include and provide for in their tender all facilities, which shall enable inspection by the Purchaser for all supply items. The tests to be carried out shall include type tests as well as routine tests in accordance with standard practice Design Basis : Design Basis No. H019-MND-PGUH-GEN-I-DBS-001 shall be followed for selection of instrumentation system. * ANNEXURE-3 – DATASHEET OF DP TYPE LEVEL TRANSMITTER General Tag No. Refer Taglist-3 Service Refer Taglist-3 P<(>&<)>ID No. Refer Taglist-3 Hazardous Area classification Safe area Operating Pressure Refer Taglist-3 Level Measurement Range Refer Taglist-3 Operating Temperature Refer Taglist-3 Mounting 2-inch pipe mounting Transmitter Type Level (DP type) transmitter Output Signal Enclosure Class 4-20 mA 2Wire HART IP-65 Accuracy ± 0.1% of span Power Supply 2 wire loop powered (24V DC) Maximum Over Pressure Turn down Ratio VTS VTS Process Connection Cable Entry 1/2 NPT (F) through manifold 1/2 NPT(F) Body Material SS316 Electronics Enclosure Cast aluminum Wetted Parts Material SS316 Gasket/O - Ring Material VTS Span <(>&<)> Zero Adjustment Adjustment screws for span and zero In-Built Lightning Protection - Integral indicator Integral LC display Accessories 3 way manifold with ½ NPT (F) Material Vendors scope SS316 Cable gland Material Vendors scope VTS Mounting accessories Material SST 2 pipe mounting VTS Purchase Manufacturer VTS Model VTS Page 7 of 12 ArcelorMittal Nippon Steel India Pvt Ltd AM/NS HAZIRA PLANT 27th KM, Surat-Hazira Road,,HAZIRA,394270,Gujarat,India GSTIN 24AAACE1741P1ZN PAN AAACE1741P CIN U27100GJ1976FTC013787 Request for Quotation Number 6000132691 Date 21.04.2025 Submission Date 29.04.2025 Coll Req No AMNS deals with OEMs directly. We are very well equipped in every way to import / buy our goods directly from OEMs from any part of the world in a professional manner. We also use the vast global networks of our parent companies where necessary. We do not welcome any contact from intermediaries or Indian Agents of vendors. We assure all OEMs that you do not need to engage anyone to manage your transactions with us.Kindly respond to our RFQs and deal with our officials directly without involving any agents or intermediaries. Offers of vendors who insist on involving intermediaries in dealings with us could be disqualified. Contact for this RFQ Ms. swati joshi Contact Email SWATI.JOSHI@AMNS.IN MATERIALS / SERVICES Please acknowledge receipt of the RFQ And provide your best quote for below given RFQ details. SR. No PR No. PR Item RFQ Item Material / Service No. Quantity UOM Detail Description Other Details 7 28040471 0009 0007 300938259 TRNSMTR,TEMP,UH,PT100,2WR,HEAD,AL Technical Details Name : Harnish Desai Contact : Email : HARNISHKUMAR.DESAI@AMNS.IN 3 NO TRANSMITTER,TEMPERATURE TYPE:UNIVERSAL HEAD , INPUT RANGE:PT100 (-200 TO 850 DEG.C) OUTPUT RANGE:0-100 , SIZE AND CONNECTION:2-WIRE RTD AND OMEGA POWER SUPPLY:24 V DC , COMMUNICATION PROTOCOL:4-20MA HART MOUNTING:HEAD-MOUNTED , ENCLOSURE:ALUMINIUM Item Details : * SCOPE :- The specification covers design, engineering, manufacturing, inspection, packing, despatch, supervision of erection, testing at site and commissioning of the instruments for central Chilled Water Plant. Drawing/Document shall be provided by successful Tenderer as per Clause No. 4.10.1.5 of this specification. Checking of calibration and pre-installation testing of all instrumentation items prior to installation to ensure that each individu al item are functionally correct and correctly calibrated and programmed. Commissioning and Performance test of all instruments shall be in Tenderer’s scope. Any item or accessories not included in this specification, but essential for proper functioning of the offered system shall be deemed to be included in the scope of the Tenderer. The design, manufacture and testing of the various equipment covered in this specification shall comply with the latest editions of the relevant Indian standards, and codes of practices or in the absence of the same, relevant international standards, codes and regulations. All equipment supplied shall also comply with the statutory requirement of the Government of India, State government (Gujarat) where instruments are to be installed and the latest revision of the International Instrumentation Rules. Factory Test: All necessary tests shall be made at the Manufacturers works, before despatch to determine whether the instruments offered conform to the relevant standards and specifications. Tests shall be conducted with the actual service conditions of site simulated as far as possible and with all external components and fittings in place, which are likely to affect the performance. Tenderer shall include and provide for in their tender all facilities, which shall enable inspection by the Purchaser for all supply items. The tests to be carried out shall include type tests as well as routine tests in accordance with standard practice Design Basis : Design Basis No. H019-MND-PGUH-GEN-I-DBS-001 shall be followed for selection of instrumentation system. * ANNEXURE-4 – DATASHEET OF TEMPERATURE TRANSMITTER General Tag No. Refer Taglist-4 Service Refer Taglist-4 P <(>&<)> ID No. Refer Taglist-4 Line Size Refer Taglist-4 Hazardous Area classification Safe area Transmitter Fluid Refer Taglist-4 Oper. Pressure Norm Refer Taglist-4 Temperature Norm Refer Taglist-4 Oper. Spec. Gravity - Instrument Type Microprocessor based SMART Sensor type Universal (Factory Set - RTD Pt100, 3 wire) Mounting Field-mounted, on 2 pipe Output Signal Accuracy 4-20 mA, HART ± 0.17 Deg C (Error) Power Supply Electrical connection 24 VDC Loop Powered 1/2 NPT(F) Integral Indicator LC Display Display Clamp on with pin/ ribbon cable/VTS In-Built Lightning Protection Provided (In-built) Enclosure Enclosure class Cast Aluminum IP-65 Accessories Cable Gland Material Vendors scope VTS Mounting bracket <(>&<)> U-clamp Material Vendor’s scope VTS Purchase Manufacturer VTS Model VTS * TAGLIST-4 - TEMPERATURE TRANSMITTER Sl. no. Tag no. Service Line size Process temp. Instrument range P<(>&<)>ID 1. 16-TIT-1017 Cooling Water Supply Common Header NA 15-35 Deg C VTS H019-MND-CHWP-CWP-U-PID-001 2. 16-TIT-1018 Cooling Water Return Common Header NA 20-40 Deg C VTS H019-MND-CHWP-CWP-U-PID-001 316TIT1019ChilldWSlCHdNA35 Page 8 of 12 ArcelorMittal Nippon Steel India Pvt Ltd AM/NS HAZIRA PLANT 27th KM, Surat-Hazira Road,,HAZIRA,394270,Gujarat,India GSTIN 24AAACE1741P1ZN PAN AAACE1741P CIN U27100GJ1976FTC013787 Request for Quotation Number 6000132691 Date 21.04.2025 Submission Date 29.04.2025 Coll Req No AMNS deals with OEMs directly. We are very well equipped in every way to import / buy our goods directly from OEMs from any part of the world in a professional manner. We also use the vast global networks of our parent companies where necessary. We do not welcome any contact from intermediaries or Indian Agents of vendors. We assure all OEMs that you do not need to engage anyone to manage your transactions with us.Kindly respond to our RFQs and deal with our officials directly without involving any agents or intermediaries. Offers of vendors who insist on involving intermediaries in dealings with us could be disqualified. Contact for this RFQ Ms. swati joshi Contact Email SWATI.JOSHI@AMNS.IN MATERIALS / SERVICES Please acknowledge receipt of the RFQ And provide your best quote for below given RFQ details. SR. No PR No. PR Item RFQ Item Material / Service No. Quantity UOM Detail Description Other Details 8 28040471 0010 0008 300919266 RTD,IND,3WR,DPLX,PT100,1000MM,6MM Technical Details Name : Harnish Desai Contact : Email : HARNISHKUMAR.DESAI@AMNS.IN 2 NO RTD,INDUSTRIAL ELEMENT:3 WIRE , TYPE:DUPLEX , DESIGN:PT100 LENGTH:1000 MM , OD:6 MM , INSERTION LENGTH:950 MM PROTECTION:WITH THERMOWELL , PROCESS CONNECTION:THREADED TERMINATION:ALUMINIUM HEAD , INSULATION:MINERAL INSULATED TEMP RANGE:0-100 °C , THERMOWELL MATERIAL:STAINLESS STEEL 316 CONNECTION DETAILS:1 INCH NPT M Item Details : * SCOPE :- The specification covers design, engineering, manufacturing, inspection, packing, despatch, supervision of erection, testing at site and commissioning of the instruments for central Chilled Water Plant. Drawing/Document shall be provided by successful Tenderer as per Clause No. 4.10.1.5 of this specification. Checking of calibration and pre-installation testing of all instrumentation items prior to installation to ensure that each individu al item are functionally correct and correctly calibrated and programmed. Commissioning and Performance test of all instruments shall be in Tenderer’s scope. Any item or accessories not included in this specification, but essential for proper functioning of the offered system shall be deemed to be included in the scope of the Tenderer. The design, manufacture and testing of the various equipment covered in this specification shall comply with the latest editions of the relevant Indian standards, and codes of practices or in the absence of the same, relevant international standards, codes and regulations. All equipment supplied shall also comply with the statutory requirement of the Government of India, State government (Gujarat) where instruments are to be installed and the latest revision of the International Instrumentation Rules. Factory Test: All necessary tests shall be made at the Manufacturers works, before despatch to determine whether the instruments offered conform to the relevant standards and specifications. Tests shall be conducted with the actual service conditions of site simulated as far as possible and with all external components and fittings in place, which are likely to affect the performance. Tenderer shall include and provide for in their tender all facilities, which shall enable inspection by the Purchaser for all supply items. The tests to be carried out shall include type tests as well as routine tests in accordance with standard practice Design Basis : Design Basis No. H019-MND-PGUH-GEN-I-DBS-001 shall be followed for selection of instrumentation system. * ANNEXURE-5 - DATASHEET OF RTD General Tag No. Refer Taglist-5 Service Refer Taglist-5 P <(>&<)> ID No. Refer Taglist-5 Line Size Refer Taglist-5 Hazardous Area classification Safe area RTD Fluid Refer Taglist-5 Oper. Pressure Norm Refer Taglist-5 Temperature Norm Refer Taglist-5 Type RTD Pt 100, 3 wire, Duplex Sheath 6 mm dia SS 316 sheath Insulation Mineral insulated Immersion Length VTS Mounting Screwed adjustable Thermowell Type Drilled bar stock threaded thermowell matching with RTD element for line size up to 500 mm. Fabricated threaded thermowell matching with RTD element for line size more than 500 mm Well material SS316 Process connection 1² NPT (M) Head Type Weatherproof with spring-loaded terminals for cable connection Enclosure Protection IP65 Material of Construction Die cast aluminum Cable entry ½² NPT(F) with double compression cable gland of Nickel-plated Brass material Purchase Manufacturer VTS Model VTS *TAGLIST5RTD Page 9 of 12 ArcelorMittal Nippon Steel India Pvt Ltd AM/NS HAZIRA PLANT 27th KM, Surat-Hazira Road,,HAZIRA,394270,Gujarat,India GSTIN 24AAACE1741P1ZN PAN AAACE1741P CIN U27100GJ1976FTC013787 Request for Quotation Number 6000132691 Date 21.04.2025 Submission Date 29.04.2025 Coll Req No AMNS deals with OEMs directly. We are very well equipped in every way to import / buy our goods directly from OEMs from any part of the world in a professional manner. We also use the vast global networks of our parent companies where necessary. We do not welcome any contact from intermediaries or Indian Agents of vendors. We assure all OEMs that you do not need to engage anyone to manage your transactions with us.Kindly respond to our RFQs and deal with our officials directly without involving any agents or intermediaries. Offers of vendors who insist on involving intermediaries in dealings with us could be disqualified. Contact for this RFQ Ms. swati joshi Contact Email SWATI.JOSHI@AMNS.IN MATERIALS / SERVICES Please acknowledge receipt of the RFQ And provide your best quote for below given RFQ details. SR. No PR No. PR Item RFQ Item Material / Service No. Quantity UOM Detail Description Other Details 9 28040471 0011 0009 300915752 RTD,IND,3WR,DPLX,PT100,600MM,6MM Technical Details Name : Harnish Desai Contact : Email : HARNISHKUMAR.DESAI@AMNS.IN 2 NO RTD,INDUSTRIAL ELEMENT:3 WIRE , TYPE:DUPLEX , DESIGN:PT100 LENGTH:600 MM , OD:6 MM , INSERTION LENGTH:500 MM PROTECTION:WITH THERMOWELL , PROCESS CONNECTION:INSERT TERMINATION:ALUMINIUM HEAD , THERMOWELL MATERIAL:STAINLESS STEEL 316 ADDITIONAL INFORMATION:RTD PT 100, WITH HEAD MOUNTED TRANSMITTER, MOUNTING SCREWED ADJUSTABLE ADDITIONAL INFORMATION-1:FABRICATED THREADED THERMOWELL MATCHING WITH RTD ELEMENT Item Details : * SCOPE :- The specification covers design, engineering, manufacturing, inspection, packing, despatch, supervision of erection, testing at site and commissioning of the instruments for central Chilled Water Plant. Drawing/Document shall be provided by successful Tenderer as per Clause No. 4.10.1.5 of this specification. Checking of calibration and pre-installation testing of all instrumentation items prior to installation to ensure that each individu al item are functionally correct and correctly calibrated and programmed. Commissioning and Performance test of all instruments shall be in Tenderer’s scope. Any item or accessories not included in this specification, but essential for proper functioning of the offered system shall be deemed to be included in the scope of the Tenderer. The design, manufacture and testing of the various equipment covered in this specification shall comply with the latest editions of the relevant Indian standards, and codes of practices or in the absence of the same, relevant international standards, codes and regulations. All equipment supplied shall also comply with the statutory requirement of the Government of India, State government (Gujarat) where instruments are to be installed and the latest revision of the International Instrumentation Rules. Factory Test: All necessary tests shall be made at the Manufacturers works, before despatch to determine whether the instruments offered conform to the relevant standards and specifications. Tests shall be conducted with the actual service conditions of site simulated as far as possible and with all external components and fittings in place, which are likely to affect the performance. Tenderer shall include and provide for in their tender all facilities, which shall enable inspection by the Purchaser for all supply items. The tests to be carried out shall include type tests as well as routine tests in accordance with standard practice Design Basis : Design Basis No. H019-MND-PGUH-GEN-I-DBS-001 shall be followed for selection of instrumentation system. * ANNEXURE-5 - DATASHEET OF RTD General Tag No. Refer Taglist-5 Service Refer Taglist-5 P <(>&<)> ID No. Refer Taglist-5 Line Size Refer Taglist-5 Hazardous Area classification Safe area RTD Fluid Refer Taglist-5 Oper. Pressure Norm Refer Taglist-5 Temperature Norm Refer Taglist-5 Type RTD Pt 100, 3 wire, Duplex Sheath 6 mm dia SS 316 sheath Insulation Mineral insulated Immersion Length VTS Mounting Screwed adjustable Thermowell Type Drilled bar stock threaded thermowell matching with RTD element for line size up to 500 mm. Fabricated threaded thermowell matching with RTD element for line size more than 500 mm Well material SS316 Process connection 1² NPT (M) Head Type Weatherproof with spring-loaded terminals for cable connection Enclosure Protection IP65 Material of Construction Die cast aluminum Cable entry ½² NPT(F) with double compression cable gland of Nickel-plated Brass material Purchase Manufacturer VTS Model VTS *TAGLIST5RTD Page 10 of 12 ArcelorMittal Nippon Steel India Pvt Ltd AM/NS HAZIRA PLANT 27th KM, Surat-Hazira Road,,HAZIRA,394270,Gujarat,India GSTIN 24AAACE1741P1ZN PAN AAACE1741P CIN U27100GJ1976FTC013787 Request for Quotation Number 6000132691 Date 21.04.2025 Submission Date 29.04.2025 Coll Req No AMNS deals with OEMs directly. We are very well equipped in every way to import / buy our goods directly from OEMs from any part of the world in a professional manner. We also use the vast global networks of our parent companies where necessary. We do not welcome any contact from intermediaries or Indian Agents of vendors. We assure all OEMs that you do not need to engage anyone to manage your transactions with us.Kindly respond to our RFQs and deal with our officials directly without involving any agents or intermediaries. Offers of vendors who insist on involving intermediaries in dealings with us could be disqualified. Contact for this RFQ Ms. swati joshi Contact Email SWATI.JOSHI@AMNS.IN MATERIALS / SERVICES Please acknowledge receipt of the RFQ And provide your best quote for below given RFQ details. SR. No PR No. PR Item RFQ Item Material / Service No. Quantity UOM Detail Description Other Details 10 28040471 0012 0010 300932448 RTD,IND,3WR,DPLX,PT100,80MM,6MM Technical Details Name : Harnish Desai Contact : Email : HARNISHKUMAR.DESAI@AMNS.IN 1 NO RTD,INDUSTRIAL ELEMENT:3 WIRE , TYPE:DUPLEX , DESIGN:PT100 , LENGTH:80 MM OD:6 MM , INSERTION LENGTH:8 MM , PROTECTION:WITHOUT THERMOWELL PROCESS CONNECTION:INSERT , TERMINATION:ALUMINIUM HEAD THERMOWELL MATERIAL:NA Item Details : * SCOPE :- The specification covers design, engineering, manufacturing, inspection, packing, despatch, supervision of erection, testing at site and commissioning of the instruments for central Chilled Water Plant. Drawing/Document shall be provided by successful Tenderer as per Clause No. 4.10.1.5 of this specification. Checking of calibration and pre-installation testing of all instrumentation items prior to installation to ensure that each individu al item are functionally correct and correctly calibrated and programmed. Commissioning and Performance test of all instruments shall be in Tenderer’s scope. Any item or accessories not included in this specification, but essential for proper functioning of the offered system shall be deemed to be included in the scope of the Tenderer. The design, manufacture and testing of the various equipment covered in this specification shall comply with the latest editions of the relevant Indian standards, and codes of practices or in the absence of the same, relevant international standards, codes and regulations. All equipment supplied shall also comply with the statutory requirement of the Government of India, State government (Gujarat) where instruments are to be installed and the latest revision of the International Instrumentation Rules. Factory Test: All necessary tests shall be made at the Manufacturers works, before despatch to determine whether the instruments offered conform to the relevant standards and specifications. Tests shall be conducted with the actual service conditions of site simulated as far as possible and with all external components and fittings in place, which are likely to affect the performance. Tenderer shall include and provide for in their tender all facilities, which shall enable inspection by the Purchaser for all supply items. The tests to be carried out shall include type tests as well as routine tests in accordance with standard practice Design Basis : Design Basis No. H019-MND-PGUH-GEN-I-DBS-001 shall be followed for selection of instrumentation system. * ANNEXURE-5 - DATASHEET OF RTD General Tag No. Refer Taglist-5 Service Refer Taglist-5 P <(>&<)> ID No. Refer Taglist-5 Line Size Refer Taglist-5 Hazardous Area classification Safe area RTD Fluid Refer Taglist-5 Oper. Pressure Norm Refer Taglist-5 Temperature Norm Refer Taglist-5 Type RTD Pt 100, 3 wire, Duplex Sheath 6 mm dia SS 316 sheath Insulation Mineral insulated Immersion Length VTS Mounting Screwed adjustable Thermowell Type Drilled bar stock threaded thermowell matching with RTD element for line size up to 500 mm. Fabricated threaded thermowell matching with RTD element for line size more than 500 mm Well material SS316 Process connection 1² NPT (M) Head Type Weatherproof with spring-loaded terminals for cable connection Enclosure Protection IP65 Material of Construction Die cast aluminum Cable entry ½² NPT(F) with double compression cable gland of Nickel-plated Brass material Purchase Manufacturer VTS Model VTS *TAGLIST5RTD Page 11 of 12 ArcelorMittal Nippon Steel India Pvt Ltd AM/NS HAZIRA PLANT 27th KM, Surat-Hazira Road,,HAZIRA,394270,Gujarat,India GSTIN 24AAACE1741P1ZN PAN AAACE1741P CIN U27100GJ1976FTC013787 Request for Quotation Number 6000132691 Date 21.04.2025 Submission Date 29.04.2025 Coll Req No AMNS deals with OEMs directly. We are very well equipped in every way to import / buy our goods directly from OEMs from any part of the world in a professional manner. We also use the vast global networks of our parent companies where necessary. We do not welcome any contact from intermediaries or Indian Agents of vendors. We assure all OEMs that you do not need to engage anyone to manage your transactions with us.Kindly respond to our RFQs and deal with our officials directly without involving any agents or intermediaries. Offers of vendors who insist on involving intermediaries in dealings with us could be disqualified. Contact for this RFQ Ms. swati joshi Contact Email SWATI.JOSHI@AMNS.IN MATERIALS / SERVICES Please acknowledge receipt of the RFQ And provide your best quote for below given RFQ details. SR. No PR No. PR Item RFQ Item Material / Service No. Quantity UOM Detail Description Other Details 11 28040471 0013 0011 300941968 TRNSMTR,FLOW,US,0-8000M3/H Technical Details Name : Harnish Desai Contact : Email : HARNISHKUMAR.DESAI@AMNS.IN 2 NO TRANSMITTER,FLOW TYPE:ULTRASONIC , INPUT RANGE:0-8000 M3/H OUTPUT RANGE:4-20 MA OR HART-7, FF, PROFIBUS-PA AND TOTALIZER SIZE AND CONNECTION:1200MM, CLAMP ON , POWER SUPPLY:230 VAC COMMUNICATION PROTOCOL:4-20 MA WITH DIGITAL SIGNAL BASED ON HART PRESSURE RATING:0-5 BAR , TEMPERATURE RATING:15-35 °C ELECTRICAL CONNECTION:4 WIRE, SCREW TERMINAL , MOUNTING:PIPE ENCLOSURE:ALUMINIUM , SERVICE:LIQUID Item Details : * SCOPE :- The specification covers design, engineering, manufacturing, inspection, packing, despatch, supervision of erection, testing at site and commissioning of the instruments for central Chilled Water Plant. Drawing/Document shall be provided by successful Tenderer as per Clause No. 4.10.1.5 of this specification. Checking of calibration and pre-installation testing of all instrumentation items prior to installation to ensure that each individu al item are functionally correct and correctly calibrated and programmed. Commissioning and Performance test of all instruments shall be in Tenderer’s scope. Any item or accessories not included in this specification, but essential for proper functioning of the offered system shall be deemed to be included in the scope of the Tenderer. The design, manufacture and testing of the various equipment covered in this specification shall comply with the latest editions of the relevant Indian standards, and codes of practices or in the absence of the same, relevant international standards, codes and regulations. All equipment supplied shall also comply with the statutory requirement of the Government of India, State government (Gujarat) where instruments are to be installed and the latest revision of the International Instrumentation Rules. Factory Test: All necessary tests shall be made at the Manufacturers works, before despatch to determine whether the instruments offered conform to the relevant standards and specifications. Tests shall be conducted with the actual service conditions of site simulated as far as possible and with all external components and fittings in place, which are likely to affect the performance. Tenderer shall include and provide for in their tender all facilities, which shall enable inspection by the Purchaser for all supply items. The tests to be carried out shall include type tests as well as routine tests in accordance with standard practice Design Basis : Design Basis No. H019-MND-PGUH-GEN-I-DBS-001 shall be followed for selection of instrumentation system. * ANNEXURE-2 - DATASHEET OF ULTRASONIC FLOW TRANSMITTER General Tag No. Refer Taglist-2 Service Refer Taglist-2 Location Refer Taglist-2 P <(>&<)> ID No. Refer Taglist-2 Area Classification Safe Area Process Conditions Fluid Refer Taglist-2 Operating Pressure Refer Taglist-2 Flow Measurement Range Refer Taglist-2 Operating Temperature Refer Taglist-2 Sensor Type Ultrasonic, clamp-on sensors with coupling pads MOC SS316L Mounting style Fixed retaining nut Type sensor fastening Strapping band Transmitter Output Signal Enclosure Class 4-20 mA HART IP-65 Accuracy ± 2% on FSD Power Supply Electrical connection 85-250 V AC 4 wire, Screw terminal Cable Entry No. of cable entry 1/2 NPT(F) 2 Electronics Enclosure Powder-coated die-cast aluminum Local Display No. of lines LC Display 2 Operating Element Push buttons Mounting Pipe mounting Sensor Cable Special shielded cable Sensor Cable Length 10 m Cable Cover Material PVC Conduit for Cable Vendor’s Scope Accessories Sensor Housing Material VTS SS304 Strapping Bands Material VTS SS304 Transmitter installation accessories Material Vendor’s scope VTS Cable Gland Material 2 nos. ½ NPT(F) VTS Purchase Manufacturer VTS Model VTS Page 12 of 12 ArcelorMittal Nippon Steel India Pvt Ltd AM/NS HAZIRA PLANT 27th KM, Surat-Hazira Road,,HAZIRA,394270,Gujarat,India GSTIN 24AAACE1741P1ZN PAN AAACE1741P CIN U27100GJ1976FTC013787 Request for Quotation Number 6000132691 Date 21.04.2025 Submission Date 29.04.2025 Coll Req No AMNS deals with OEMs directly. We are very well equipped in every way to import / buy our goods directly from OEMs from any part of the world in a professional manner. We also use the vast global networks of our parent companies where necessary. We do not welcome any contact from intermediaries or Indian Agents of vendors. We assure all OEMs that you do not need to engage anyone to manage your transactions with us.Kindly respond to our RFQs and deal with our officials directly without involving any agents or intermediaries. Offers of vendors who insist on involving intermediaries in dealings with us could be disqualified. Contact for this RFQ Ms. swati joshi Contact Email SWATI.JOSHI@AMNS.IN MATERIALS / SERVICES Please acknowledge receipt of the RFQ And provide your best quote for below given RFQ details. SR. No PR No. PR Item RFQ Item Material / Service No. Quantity UOM Detail Description Other Details 12 28040471 0014 0012 300941962 TRNSMTR,FLOW,US,0-5000M3/H,CLAMPON Technical Details Name : Harnish Desai Contact : Email : HARNISHKUMAR.DESAI@AMNS.IN 1 NO TRANSMITTER,FLOW TYPE:ULTRASONIC , INPUT RANGE:0-5000 M3/H OUTPUT RANGE:4-20 MA OR HART-7, FF, PROFIBUS-PA AND TOTALIZER SIZE AND CONNECTION:CLAMP ON , POWER SUPPLY:230 V AC COMMUNICATION PROTOCOL:4-20 MA WITH DIGITAL SIGNAL BASED ON HART PRESSURE RATING:0-10 BAR , TEMPERATURE RATING:3-5 °C ELECTRICAL CONNECTION:1/2 INCH NPT F , MOUNTING:PIPE MOUNTING ENCLOSURE:ALUMINIUM , SERVICE:LIQUID Item Details : * SCOPE :- The specification covers design, engineering, manufacturing, inspection, packing, despatch, supervision of erection, testing at site and commissioning of the instruments for central Chilled Water Plant. Drawing/Document shall be provided by successful Tenderer as per Clause No. 4.10.1.5 of this specification. Checking of calibration and pre-installation testing of all instrumentation items prior to installation to ensure that each individu al item are functionally correct and correctly calibrated and programmed. Commissioning and Performance test of all instruments shall be in Tenderer’s scope. Any item or accessories not included in this specification, but essential for proper functioning of the offered system shall be deemed to be included in the scope of the Tenderer. The design, manufacture and testing of the various equipment covered in this specification shall comply with the latest editions of the relevant Indian standards, and codes of practices or in the absence of the same, relevant international standards, codes and regulations. All equipment supplied shall also comply with the statutory requirement of the Government of India, State government (Gujarat) where instruments are to be installed and the latest revision of the International Instrumentation Rules. Factory Test: All necessary tests shall be made at the Manufacturers works, before despatch to determine whether the instruments offered conform to the relevant standards and specifications. Tests shall be conducted with the actual service conditions of site simulated as far as possible and with all external components and fittings in place, which are likely to affect the performance. Tenderer shall include and provide for in their tender all facilities, which shall enable inspection by the Purchaser for all supply items. The tests to be carried out shall include type tests as well as routine tests in accordance with standard practice Design Basis : Design Basis No. H019-MND-PGUH-GEN-I-DBS-001 shall be followed for selection of instrumentation system. * ANNEXURE-2 - DATASHEET OF ULTRASONIC FLOW TRANSMITTER General Tag No. Refer Taglist-2 Service Refer Taglist-2 Location Refer Taglist-2 P <(>&<)> ID No. Refer Taglist-2 Area Classification Safe Area Process Conditions Fluid Refer Taglist-2 Operating Pressure Refer Taglist-2 Flow Measurement Range Refer Taglist-2 Operating Temperature Refer Taglist-2 Sensor Type Ultrasonic, clamp-on sensors with coupling pads MOC SS316L Mounting style Fixed retaining nut Type sensor fastening Strapping band Transmitter Output Signal Enclosure Class 4-20 mA HART IP-65 Accuracy ± 2% on FSD Power Supply Electrical connection 85-250 V AC 4 wire, Screw terminal Cable Entry No. of cable entry 1/2 NPT(F) 2 Electronics Enclosure Powder-coated die-cast aluminum Local Display No. of lines LC Display 2 Operating Element Push buttons Mounting Pipe mounting Sensor Cable Special shielded cable Sensor Cable Length 10 m Cable Cover Material PVC Conduit for Cable Vendor’s Scope Accessories Sensor Housing Material VTS SS304 Strapping Bands Material VTS SS304 Transmitter installation accessories Material Vendor’s scope VTS Cable Gland Material 2 nos. ½ NPT(F) VTS Purchase Manufacturer VTS

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail