| 1 | Removing dry or oil bound distemper by scrapping sand papering and preparing surface smooth including necessary repairs to scratches by sandla/loi and all scaffolding (for colour changing only) |
| 2 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50m lead With cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 3 | Repair to damaged RCC slabs, beams and columns etc for strengthening with cement mortar 1:2 in following steps(i) Choping losse and cracked concrete to required depth, cleaning the exposed surface of steel and concrete with wire brush and sand papering , cleaning of concrete surface with water as necessary and getting dried.(ii) Applying Epoxy primer on the exposed steel bars.(iii) Applying Epoxy hardener and resin mix (as per manufactured s specification) on concrete and steel bars with brush.(iv) Spreading dry cement mortar 1:2 mix over epoxy treated wet surface and allow it to dry for one day.(v) Plastering the surface with cement sand mortar 1:3 upto depth of 30mm complete.(vi) Cure the plastered surface for 15 days all work including scaffolding etc. complete in all respect |
| 4 | Providing and Applying white cement based putty over plastered surface to prepare the surface even and smooth complete |
| 5 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : Old work (One or more coats) |
| 6 | Providing and laying APP (Atactic Polypropylene polymer) modified prefabricated five layer 3mm thick water proofing membrane, black finished reinforced with non woven polyster matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40ltr/sqmt by the same membrane manufacture of density at 25ºC, 0.87-0.89 kg/ltr. and viscosity 70-160 cps. over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc. and preparing the surface complete. the vital physical and chemical parameters of the membrane shall be as under joint strength in longitudinal and transverse direction at 23ºC as 650/450/5cm tear strength in longitudinal and transverse direction as 300/250 N softening point of membrane mot less than 150ºC cold flexibility shall be upto -2ºC when tested in accordance with ASTM D-5147. The laying of membrane shall be got done through the authorized applicator of the manufacturer of membrane. 3 mm thick. |
| 7 | P & F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor : 1.0 mm thick stainless steel AISI -304 & IS 13983-1994 kitchen sink of approved make as per Engineer- in-charge with large waste coupling 24×18×8 Bowl size 20×16×8 |
| 8 | P & F 1st quality heavy Duty vitrified glazed MAT tiles on floor, skirting and steps etc. in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS:15622 of approved make in all colour and shade, laid with 20 mm thick CM 1:4 including grouting the joints with white cement and matching pigment etc. complete. size 600mm × 600 mm |
| 9 | Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and amp; cold water supply including all CPVC plain and amp; brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and amp; fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.) |
| 10 | 20 mm nominal outer dia pipes |
| 11 | 25 mm nominal outer dia pipes |
| 12 | P & F Low level flushing cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS 1703 mark) complete including cutting and making good the wall. PVC with bend as per IS 7231 |
| 13 | Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make110 mm dia |
| 14 | Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make |
| 15 | Single Tee 110 mm dia |
| 16 | Bend 45º |
| 17 | Coupler (socket) 110 mm dia |
| 18 | Vent Cowel 110 mm dia |
| 19 | Half brick masonry in Superstructure, above plinth level upto floor V level using bricks of designation 75 Cement mortar 1:3 (1 cement : 3 coarse sand) |
| 20 | Providing and fixing to existing door frames 30mm thick factory made polyvinyl chloride (PVC) door shutter made of stiles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2mm +/- 0.2mm with inbuilt decorative moulding edging on one side. The stiles and rails mitred and joined and the corners by means of M.S. galvanized/plastic brackets of size 75×220 mm having wall thickness 1.0mmand stainless steel screws. The stiles of the shutter reinforced by inserting galvanized M.S. tube of size 25×20 mm and 1mm +/- 0.1mm wall thickness. The lock rail made up of “H” section, a uPVC hollow section of size 100×30 mm and 2mm +/- 0.2mmwall thickness fixed to the shutter stiles by means of plastic/galvanized M.S. tube “U” cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 610mm, having overall thickness of 20mm and 1mm+/- 0.1mm wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6mm galvanized M.S. rod and fastened with nuts and washers. complete as per manufacturer’s specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter) |
| 21 | Providing and fixing factory made P.V.C. door frame of size 50×47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos. of 150mm long brackets of 15×15mm M.S. square tube, the vertical door profiles to be reinforced with 19×19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size complete as per manufacturers specification and direction of Engineer-in-Charge. |
| 22 | P & F PVC Storage Tank ISI Marked (IS : 12701) indicating he BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 500 litres capacity. |
| 23 | Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : One or more coats on old work. |
| 24 | Plaster on new surface on wall in cement sand mortar 1:3 including racking of joints etc. complete fine finish : 12mm thick |
| 25 | Labour charges for repair to door / window without using any material such as applying randha (finishing) tightening of bolts & screw etc. |
| 26 | Repair of door, window shutters including cost of material and labour for change of damaged : (f) Steel Hinges For Stone Chowkhat, 4\"size |
| 27 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding: Old work (one or more coats) including scrapping surface and necessary repairs. Colour Change |
| 28 | Add extra for mirror polishing on existing marble work/ Kota stone flooring work where ever required to give high gloss finish complete. |