| 1 | M&L in repair/replacment LED light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embeddee PC cover having top opening separate driver compartment with IP 66 portection ,including LED lamps of 35Watt and connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed by Engr-in-Charge. |
| 2 | M&Lin repair /replacement LED street light made up of pressure die cast housing with toughned glass and individual high power LEDs withsecondary optics,potted drever,IP 66 portection, including LED lamps of 60 Wattand connecting up with twin core twisted flexible copper conductor cable of suitable size,complete all as specified and as directed by Engr-in-Charge. |
| 3 | M&L in repair /replacement LED street light made up of pressure die cast housing with toughned glass and individual high power LEDs withsecondary optics,potted drever,IP 66 portection, including LED lamps of 120 Wattand connecting up with twin core twisted flexible copper conductor cable of suitable size,complete all as specified and as directed by Engr-in-Charge. |
| 4 | M&L in repair /replacement electronic LED driver for LED light fittings capacity 45 watt,50Hz,complete all as specified and as directed by Engr-in-Charge. |
| 5 | Excavation in trenches n.exc. 1.5 mtr wide and n.exc 1.5 mtr deep for foundations of poles/stays/cable etc not exc 10 Sqm area on plan and getting out in Hard/Dense soilcomplete all as specified and as directed by Engr-in-Charge. |
| 6 | Returning filling in including spreading levelling, watering and well ramming in layer each not exc. 25 cm thick in a soft/loose soilcomplete all as specified and as directed by Engr-in-Charge. |
| 7 | Removing surplus soil to a distance not exc. 50 mtr and depositing where directed at a level n.exc. 1.5 mtr above the starting pointcomplete all as specified and as directed by Engr-in-Charge. |
| 8 | M&L for PCC cable coverClass LV, Type I,flat,size 250 mm x 150mm x 40mm laid Flat in trenches over the cable with length 250mm perpendicular to the direction of cable, adjacent/ abutting each other complete all as specified and as directed by Engr-in-Charge.MAKE: NTC, NITCO, ULTRA, JOHNSON, RUCHI, any other BIS approved manufacturer (ISI marked) as approved by GENote:-Excavation and earth work to be measured and paid for separately |
| 9 | M&L Sand cushioning to protection of underground cables, laid 8 cm before laying and 15 cm after laying of cable, and punned to form an overall layer of 18 cm thick complete all as specified and as directed by Engr-in-Charge.Note: Punned thickness shall be measured. |
| 10 | S&F LTJunction box for street lights,sheet Moulding compound(smc) hinged door type and locking arrangment ,off white colour of size 155 x 155 x 100mm (internal dimensions) comprising 2 Nos aluminium bus bar of adequate capacity including suitable size MS Clamps,including taking down old unserviceble junction box complete all as specified and as directed by Engr-in-Charge. |
| 11 | S&F in repair including taking out old LT Junction box for street Moulding compound(smc) hinged door type and locking arrangment ,off white colour of size 240 x 130 x 95 mm (internal dimensions) comprising 4 Nos aluminium bus bar of200 Amps complet on 6 Amp MCB SP adequate capacity including suitable size MS Clamps,including taking down old unserviceble junction box complete all as specified and as directed by Engineer-in-Charge. |
| 12 | S&F Aviation obstruction light in die cast aliminium alloy housing built in 75V step up transformer 1x 75VA neno spiral lamp,heat resistant, clearthick glass dome complete with all acessories as specified and as directed by Engineer -in-Charge. |
| 13 | M&L in repair /replacement XLPE insulated screened PVC bedded galvanised steel strip or wire armoured heavy duty electric cable with aluminium conductor 1100Volts grade cross sectional area 16.0 sqmm 2 core laid in trenches or passing through pipes including suitable lugs and accessories for making connections at both endscomplete all as specified and as directed by Engr-in-Charge. |
| 14 | All as per Srl Item No 13.00 above but of size cross-sectional area 16.0 Sqmm, 4-corecomplete all as specified and as directed by Engr-in-Charge. |
| 15 | All as per Srl Item No 13.00 above but of size cross-sectional area 185.0 Sqmm, 3.5 -corecomplete all as specified and as directed by Engr-in-Charge. |
| 16 | All as per Srl Item No 13.00 above but of size cross-sectional area 300.0 Sqmm, 3.5 -corecomplete all as specified and as directed by Engr-in-Charge. |
| 17 | Replacement of old unserviceable/damaged street light bracket made out of GI pipe 40 mm gore light grade 1.5 m long bend to shape required fixedto pole/wall with ms clamps madeout of 40 x5 mm, 50 cm long incl nuts bolts of size 80 x 12 mmcomplete all as specified and as directed by Engr-in-Charge. |
| 18 | S&F in weather proof flat twin core cable aluminium conductor cable 2.5 sqmmcomplete all as specified and as directed by Engr-in-Charge. |
| 19 | M&L for GI pipe 20mm dia light grade for passing through wire between terminal box to street light with GI Clamp complete all as specified and as directed by Engr-in-Charge. |
| 20 | Supply andfixing SPN 32 Amp rating 240v,10KA \"C\" curve MCB 32 amp current carring capacity in the MCB DB complete with connection testing and commissioningcomplete all as specified and as directed by Engr-in-Charge. |
| 21 | M&L in repair/replacement fabrication and install street light terminal box outdoor canopy type size 40cm Height x 30 cm width x 12 cm thick size of canopy 30cm x 13 cm complete with locking arrangement,4 Nos aluminium busbar size 20 x 5mm, 8Nosnut, bolt & 8 Nos aluminium cable socket suitable for upto 185 sqmm cable embeded in PCC foundation with 2 Nos angle iron leg 25 x 25 mm 40 cm long as per sample incl taking down complete all as specified and as directed by Engr-in-Charge. |
| 22 | M&L in repair /replacement Change overswitch ,rating 100Amps ,four poles 415 volts AC ,50 Hz,onload ,conforms to IS: 13947 (part-3) IEC : 60947-2,side handle ,fixing in repairscomplete all as specified and as directed by Engr-in-Charge..Make:- Havells cat part No- IHBFFF0100 or equivalent |
| 23 | M&L in repair /replacement Change overswitch ,rating 200 Amps ,four poles 415 volts AC ,50 HZ off load ,conforms to IS: 13947 (part-3) IEC : 60947-2,side handle ,fixing in repairs ,Complate all as specified and as directed by Engineer -in-Charge.Make:- Havells cat part No- IHBFFF0200 or equivalent |
| 24 | M&L inrepair/replacement Mild steel bands ,straps,includingbolts,if required clamps for house brackets for mounting street/securty lights fittings,ties hooks for hanging fans and similar smalll articles conforming to Fe -290 Gde E-165,complete all asspecified and as directed by Engineer-in Charge. |
| 25 | Attending day to day complaints for maintenance and repair of LT Network of any type and any specifications or any accessories related to Electric Supply of any descriptions, fitted/ fixed on poles, buildings or watching towers of any heights and any location, and re-fixing the same after necessary repairs/ replacement of defective parts including rectifying the same as per directions by concerned JE E/M and Engineer-In-Charge, at various locations, complete all as specified and directed by Engineer-In-Charge.Note: (i) Cost of T&P, ladder or mechanical lift shall be deemed included in quoted rate.(ii) Supply of spare parts of light fittings shall be measured and paid separately. |
| 26 | Note: The work under subject BoQ (item No. 1 to 25 ) is meant for maint of External Electric Supply in AF Stn Thoiseunder GE(AF ) Thoise. The work shall be executed on ground on required basis. Contractor shall deploy sufficient resources to keep smooth working of External Electric Supply in the AF station. Contractor or his representative will daily attend thecomplaints at E/M complaint cell and in addition any breakdown shall be communicated to contractor or his representative by concerned Engineer-in-charge/JE E/M through phone call, text message, complaint slip and or in writing through site order book or through other means. Non complying of attending breakdown by contractor within 24 hours after notify the complaint, recovery @ Rs 1500/- per day shall be recovered from contractor\"s payment for each complaint so notified. |