}

Stage Contract For The Day To Day Maintenance Works Of The Buildings To Be Executed During The Year 2025-26 Sub- Division Udhampur (Group-I)- I) Ddc Office Complex Udhampur, Ii) Distt. Court Complex Udhampur, Iii) Tehsildar Office Complex, Iv) Addc Office, udhampur-Jammu And Kashmir

Public Works Department has published Stage Contract For The Day To Day Maintenance Works Of The Buildings To Be Executed During The Year 2025-26 Sub- Division Udhampur (Group-I)- I) Ddc Office Complex Udhampur, Ii) Distt. Court Complex Udhampur, Iii) Tehsildar Office Complex, Iv) Addc Office. Submission Date for this Tender is 01-05-2025. Housekeeping Services Tenders in udhampur Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

48746459
Stage Contract For The Day To Day Maintenance Works Of The Buildings To Be Executed During The Year 2025-26 Sub- Division Udhampur (Group-I)- I) Ddc Office Complex Udhampur, Ii) Distt. Court Complex Udhampur, Iii) Tehsildar Office Complex, Iv) Addc Office
Open Tender
Indian
Jammu And Kashmir
Udhampur
01-05-2025

Tender Documents

Tender Details

Stage Contract for the day to day maintenance works of the buildings to be executed during the year 2025-26 Sub- Division Udhampur (GROUP-I)- i) DDC Office Complex Udhampur, ii) Distt. Court Complex Udhampur, iii) Tehsildar Office Complex, iv) ADDC Office Complex, v) Badminton Court Udhampur, vi) Food & Supply Office Complex Udhampur, vii) Distt. Hospital Complex Udhampur, viiii) ADC Office Complex Udhampur, ix) Conference hall in DDC Complex Udhampur incl. other Govt. Offices.- 1 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: 1:3:6 or richer mix (i/c equivalent design mix) 2 Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge 3 Extra for cutting reinforcement bars manually/by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional areas of R.C.C. or R.B. work) as per direction of Engineer-in-charge 4 Extra for scraping, cleaning and straightening reinforcement from R.C.C or R.B work. 5 Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar 6 Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m. (stacks of cleaned bricks shall be measured) : From brick work in cement mortar 7 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead 8 of area of 3 Sqm. and below 9 of area beyond 3 Sqm. 10 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 meters lead 11 of area of 3 Sqm. and below 12 of area beyond 3 Sqm. 13 Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 meters lead 14 Demolishing mud phaska in terracing and disposal of material within 50 meters lead 15 Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meters lead 16 Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 meters lead With cement mortar 1:4 (1 cement : 4 fine sand) 17 Renewing glass panes, with putty and nails wherever necessary including raking out old putty 18 Float glass panes of thickness 4.0 mm (weight not less than 10kg/sqm) 19 Float glass panes of thickness 5.0 mm (weight not less than 12.5 kg/sqm) 20 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering grade. All work upto linth level. 21 1:5:10 (1 cement : 5 coarse sand : 10 graded crushed stone agg. 40mm nominal size) 22 1:4:8 (1 cement : 4 coarse sand : 8 graded crushed stone agg. 40mm nominal size) 23 1:3:6 (1 cement : 3 coarse sand : 6 graded crushed stone agg. 20mm nominal size) 24 1:2:4 (1 cement : 2 coarse sand :4 graded crushed stone agg. 20mm nominal size) 25 Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand) 26 Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level 27 Extra for brick work/tile brick/AAC block masonryin superstructure above floor V levelfor each four floors or part thereofby mechanical means 28 Extra for brick work in square or rectangular pillars. 29 Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in Cement mortar 1:4 ( 1 cement : 4 coarse sand) 30 Extra for half Brick masonry in superstructure above plinth level upto floor V level. 31 Providing and laying damp-proofCourse 50 mm thickwith cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete 32 Centering and shuttering including strutting, propping etc and removal of form work for:- 33 Foundation, footing, bases of columns. 34 Suspended floors, roofs, Landing, balconies and access platform. 35 Shelves (Cost in Situ) 36 Edges of slab and breaks in floors and walls under 20 mm wide 37 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 38 Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and strutsupto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 39 Reinforcement for R.C.C work incuding straightening cutting, bending, placing in positionand binding all complete, Thermo-Mechanically Treated bars of grade Fe-500D or more 40 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 41 Regrading terracing of mud phaska covered with tiles or bricks, in cement by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud phaska to proper slope, relaying mud plaster gobri leaping and tiles or bricks, grouted in cement mortar 1:3 (1 cement: 3 fine sand), including replacing unserviceable tiles or bricks with new ones and disposal of unserviceable material to the dumping ground (the cost of the new tiles or brick excluded) within 50 meters lead 42 Raking out joints in lime or cement mortar and preparing the surface for re-pointing or re-plastering, including disposal of rubbish to the dumping ground within 50 meters lead 43 White washing with lime to give an shades 44 Old work (Two or more coats) 45 Old work ( One or more coats) 46 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth incl. necessary repairs to scratches etc complete. 47 Distempering with 1st quality Acrylic/oil bound washable distemper (ready-made) having VOC content less than 50 grams/litre of approved manufacturer and of required shade and colour complete as per manufacturers’ specifications, one or more coats on old work 48 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete 49 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade, one or more coats on old work 50 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, one or more coats on old work 51 15 mm cement plaster on the rough side of single or half brick wall of mix 52 1:6 (1 cement : 6 coarse sand) 53 1:4(1 cement : 4 coarse sand) 54 20 mm cement plaster of mix 1 : 6 ( 1 cement : 6 coarse sand) 55 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer 56 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface 57 Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) 58 Finishing walls with water proofing cement paint of required shade 59 New work (Two or more coats) applied @ 3.84 Kg/10Sqm 60 Old work (One or more coats) applied @ 2.20 Kg/10Sqm over priming coat of primer applied @ 0.80 ltrs./10 Sqm complete including cost of priming coat. 61 Applying priming coat 62 With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) 63 With ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel galvanized iron/steel works 64 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, one or more coats on old work 65 Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work 66 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work 67 Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1 mm thick 68 Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick 69 Providing and fixing Polyethylene- Aluminum- Polyethylene (PE-ALPE) Composite Pressure Pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot and cold water supply, capable to withstand temperature upto 80ºC, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. Elbows, tees, reducers, couplers and connectors etc. This includes testing of joints complete as per direction of the Engineer-in-charge: Internal work-exposed on wall with clamps at 1.00 meter spacing 70 1216 (16mm OD) pipe 71 1620 (20 mm OD) pipe 72 2025 (25 mm OD) pipe 73 Providing and fixing Polyethylene- Aluminum- Polyethylene (PE-ALPE) Composite Pressure Pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot and cold water supply, capable to withstand temperature upto 80ºC, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. Elbows, tees, reducers, couplers and connectors etc. This includes testing of joints complete as per direction of the Engineer-in-charge: Internal work concealed with clamps at 1.00 meter spacing including cutting the chases and making good the wall etc. 74 1216 (16mm OD) pipe 75 1620 (20 mm OD) pipe 76 2025 (25 mm OD) pipe 77 Providing and fixing G.I pipes complete with G.I fittings and clamps, including cutting and making good the walls etc Internal work-Exposed on wall (Surya, Jindal Make) 78 15 mm dia nominal bore (Medium) 79 20 mm dia nominal bore (Medium) 80 25 mm dia nominal bore (Medium) 81 Providing and fixing G.I Pipes complete with G.I fittings excluding trenching and refilling etc (External work) (Surya, Jindal Make) 82 15 mm dia nominal bore (Medium) 83 20 mm dia nominal bore (Medium) 84 25 mm dia nominal bore (Medium) 85 Providing and fixing G.I union in G.I pipe including cutting and threading the pipe and making long screws etc complete. (New work) (Surya, Jindal Make) 86 15 mm nominal bore 87 20 mm nominal bore 88 25 mm nominal bore 89 Providing and fixing on wall face un-plasticized Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. Single socketed pipes 90 75 MM dia pipe 91 110 MM dia pipe 92 Providing and fixing on wall face un-plasticized - PVC moulded fittings/ accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mmgap for thermal expansionBend 87.5° 93 75mm dia bend 94 110 mm dia Bend 95 Providing & fixing white vitreous China pedestal type water closet (Europen Type) with cistern (A/PHAS-100+Cat No. 21054) with CP bolts, nuts, CI chair hanging arrangements, bakelite seat & cover with CP hinges & rubber buffers, CP brass screw, washer with all accessories with WC connector with rubber lip/ buffer and side gap filled with silicon sealant wherever required. including brass/ SS screws and washer complete including cutting, making good the walls, floors, slab wherever required as per direction of engineer in charge 96 Providing & fixing of white vitreous china wash basin with pedestal (Hindware Cat No. 1008+ Pedestal Cat No. 11003) with CP brass waste assembly, CP cast brass bottle trap with extension piece (Jaguar Cat No. 769B+Parko 1535 or approve equivalent), 450 mm longCP Copper connecting pipes (Jaguar Cat No. 803B or Parko 1535 or approved equivelent) wall flanges and rubber adopters for waste connection complete including CI/MS brackets duly painted, nuts, washers, cutting and making good the walls floors wherever required as per direction of Engineer- in- charge. 97 Providing & fixing CP single liver extended basin mixer (Height 85 mm) without popup waste system with 450 mm long braided hoses and brass trap with all fittings and accessories as per direction of engineer in charge (Jaguar FUS 29023B) 98 Providing & fixing CP hand spray with lever control (health faucet) (Jaguar Cat No. ALDCHR-565) and flexible hose 1.0 mtr long connection with CP holder for hand spray complete in all respects as per direction of engineer in charge. 99 Providing & fixing CP brass angle valve for basin mixer and geyser points of approved quality conforming to IS : 8931 a) 15 mm nominal size (Make Jaguar FUS 29053). 100 Providing & fixing of Soap Dish Holder with all fittings as per direction of engineer in charge (Jaguar Cat No. ACN 113N). 101 providing & fixing 6 mm copper backed float glass mirror MODI/ SAINT- GOBAIN including 6 mm thick BWR type ply wood, 40 mm stainless steel channel plugged to wall, hard wood treated with two coats of wood preservative etc. All complete as specified and shown in drawing complete to the statisfaction of engineer in charge. 102 providing & fixing brass towel ring square with round flenge of approved make complete with all fittings (Jaguar Cat No. ACN 11021 BN) 103 Providing & fixing of glass shelf 600 m long with all CP fittings of approved quality complete item (Jaguar Cat No. ACN 11071 N). 104 Providing & fixing toilet holder with all fittings Jaguar Contienal ACN 1153 N. 105 Providng & fixing 15 mm dia CP brass bib cock with wall flange of approved quality conforming to IS standard (Jaguar Cat NO. 29037) 106 Providing & fixing regular body of concealed stop cock suitable for 15 mm pipe line with protection cap (Jaguar ALD-083) with exposed part angular stop cock with flange FUS 29.53 107 Providing & fixing heavy class SS grating with cockroach proof SS stramer of approved design including floor trap & setting in floor with cement motor to match with floor finish as per direction of engineer in charge (Size 100 mm dia (ISI marked) 108 Providing and fixing of CP brass 2 in 1wall mixer Jaguar MAKE 109 Providing and fixing of CP brass basin mixer Jaguar MAKE 110 Providing and fixing of CP brass waste coupling full length for wash basin etc 111 Providing and fixing of plain CP jali 112 Providing and fixing of cp brass cap 113 Providing and fixing of CP brass nipple (12-25) mm long Jaguar MAKE 114 Providing and fixing of CP brass nipple (12-37) mm long Jaguar MAKE 115 Providing and fixing of CP brass nipple (12-100) mm long Jaguar MAKE 116 Providing of CP brass liquid soap Dispenser 117 Providing and fixing of powder coated aluminium 50 microns in partitions including glazing with float glass pane of minimum 5mm thickness or 12mm thick particle board decorative on both sides average spacing between each aluminium members should not exceed 0.9m c/c both horizontally and vertically. Complete including all harware items ie Handles, hinges, tower bolts, door, closer, Aldrop, rubber sealing etc. Including all types of doors and windows. (Double shutters for doors and windows will be paid for separately) 118 Waste couplling 119 Phase 120 Long nose bib cock 121 PVC connection pipes 122 Waste pipes 123 ball valves-3/4 124 ball valves-(1/2) 125 Chrome Plated (CP)Towel Ring Jaguar MAKE 126 Seat cover Jaguar MAKE 127 C.P Jet sprayJaguar MAKE 128 C.P pillar cock Jaguar MAKE 129 Acid for cleaning of chocked Waste pipes 130 CP Soap dish container 131 Providing and Fixing of Stainless steel Gate of grade 304 of Jindal Make 132 Providing and Fixing of Stainless steel Railing of grade 304 of Jindal Make of minimum height 0.9m. The minimum horizontal member in the railing should be 4 in nos including top rail. The verticles post should be 1.5m centre to centre and intermediate post should be provided on each step including main posts at each corner. 133 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 134 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 135 Extra for depth. for man holes ofSize 90x80cmWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5 136 Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) For fixed portion 137 Anodized aluminum (Anodized transparent or dyed to required shade according to IS:1868, minimum anodic coating of grade AC 15) 138 Powder coated aluminum (minimum thickness of powder coated 50 microns) 139 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate Z-section and other sections of approved make conforming to IS 733 and IS 1285, fixed with dash fastener ofrequired dia and size incl. necessary filling upto gaps at junctions i.e at top, bottom and sides with required EPDM rubber/ neoprane gasket felt etc. Aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically wherever required incl. cleat angle, aluminium snap beading for glazing / panelling, C.P brass / stainless steel screws, all complete as per architectural drawing and the directions of Engineer-in-charge (glazing ,panelling and dash fasterner to be paid for reparately). For fixed portion For shutters of doors, windows & ventilators incl. providing and fixing hinges /pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprane gasket required (fittings shall be paid for separately). 140 Anodized aluminum (Anodized transparent or dyed to required shade according to IS:1868, minimum anodic coating of grade AC 15) 141 Powder coated aluminum (minimum thickness of powder coated 50 microns) 142 Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board (conforming to IS: 12823 Grade-I type-II) in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-incharge. Pre-laminated particle board with decorative lamination on both sides 143 Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin-charge. (Cost of aluminum snap beading shall be paid in basic item.)With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm) 144 Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked,having brand logo embossed on the body/plate with double spring mechanism and door weight upto 125 kg for doors including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineerin- plate etc. complete as per the direction of Engineer-in-charge. With Stainless Steel cover plate minimum 1.25 mm thickness 145 Providing and fixing Brass 100mm mortice latch and lock with 6levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete 146 Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete 147 300 x 16mm 148 250 x 16mm 149 Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc complete. 150 200 x 10 mm 151 150 x 10 mm 152 100 x 10 mm 153 Providing and fixing alumnium handles ISI marked anodised (anodic coating not less than grade AC as per IS:1868) transparent or dyed to required colour and shade with necessary screws etc complete. 154 125mm 155 100mm 156 75mm 157 Providing and fixing in position collapsible steel shutters with vertical channels 20x 10x2 mm and braced with flat iron diagonals 20 x5 mm size with top and bottom rail of T- iron 40x40x6mm with 40 mm dia, steel pulleys complete with bolts, nuts, locking arrangment, stoppers, handles, including applying a priming coat of approved steel primer. 158 Providing & fixing panelled or panelled & glazed shutters for Doors and windows & clerestoy windows incl. ISI marked M.S pressedButt hinges bright finished of required size with necessary screws excluding panelling which will be paid separately, all complete as per direction of Engineer-in-charge. 159 Second class Deodar wood : 30mm thick 160 Second class Deodar wood : 35mm thick 161 Providing & fixing panelling or panelling & glazing in panelled or panelled and glazed shutters for doors, windows & clerestory windows (Area of opening for panel insert excluding portion inside Grooves or rebates to be measured) panelling for panelled or panelled & Glazed shutters 25mm to 40mm particle board 12mm thick, 162 Providing and fixing 35mm thick wire gauge shutters using Galvanised M.S wire gauge of average width for aperture 1.4mm in both directions with wire of dia 0.63 mm for doors, windows and clear story windows with hinges and necessary screw & including ISI marked bright M.S bright finishedM.S Butt hinges with neceaasry screw of required size. Second Class Deodar wood. 163 Providing and fixing wooden moulded beading to doors & windows frames with iron screws, plugs & priming coat on unexposed surface etc complete. 2nd class Teak wood 164 50x12mm 165 50 x 20mm 166 Providing & fixing curtain Rods of 1.25 mm thick chromium plated brass plate with two chromium plated brass Brackets fixed with C.P Brass screws & wooden plugs etc wherever necessary complete. 167 12mm dia 168 20mm dia 169 Providing and fixing tiles false ceiling of approved material of 595x595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanised @ 120 Sqm. both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross T of size 24x25mm made of 0.30 thick sheet 1200mm lay spaced between man T at 600mm center to center to form a grid of 1200x600mm and secondary cross T of length 600mm size 24x25mm made of 0.30 mm thick sheet to be interlocked at middle of 1200 x 600mm panel to form grids of 600x600 and wall angle of size 24x24x0.30mm laying false ceiling tiles of approved texture in the grid. including, wherever required cutting/making, opening for services like diffusers, grills, light fittings, fixtures smoke detectors etc Main T runners to be suspsnded form ceiling using G.I slotted cleats of size 27x37x25x1.6mm fixed to ceiling with 12.5mm dia and 50mtr. long dash fasterners 4mm G.I adjustable rods with galvanised butterfuly level clips of size 85x30x0.8mm spaced at 1200mm center to center along main T, bottom GI Metal ceiling lay in perforated Tegular edge globawhite color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop made of GI sheet having galvanizing of 100 gm/sqm (both sides inclusive) and 20% perforationarea with 1.8 mm dia holes and having NCR (Noice Reduction Coefficient) of 0.5 electro statically polyesterpowder coated of thickness 60 microns (minimum), including factory paintedafter bending and perforation, and backed with a black Glass fiber acoustical fleece.exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 170 10cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25mm thick mud mortar mixed with bhusa at 35 kg/Cum of earth and gobri leeping with bhusa at 3.5kg/cum 8 earth and mixed with 1:1(1 clay : 1 cow dung) and covered with flat tile bricks of class designation 100 grouted with cement mortar 1:3 mixed(1 cement : 3 fine sand) with 2% of integal water proofing compound by weight of cement and finsihing neat with hand moulded FPS brick tiles. 171 Extra for every additional 1 cm thickness of mud phaska. 172 Providing gola 75 x 75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand4 graded stone 10mm down gauge) incl. finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design in 75 x 75mm deep chase. 173 Making khurras 45x45cm with average min. thickness of 5cm cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone agg. 20mm nominal size) over pvc sheet 1mx1mx400 micron finished with 12mmcement plaster 1:3 (1 cement : 3 coarse sand)and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 174 Providing and layingwater proofing treatment in sunkan portion of WCs, bathroom etc.by applying cement slurry mixed water proofing cement compound consisting of applying.a) After surface preparation, first layer of slurry of cement @0.488 Kg/Sqm mixed with water proofing cement compound @0.253 Kg/sqm. This layer will be allowed to air cure for 4 hours.b)Second layer of sullary of cement @ 04242 Kg/Sqm mixed with water proofing cement compound @ 0.126 Kg/Sqm. This layer will be allowed to air cure for 4 hours followed with water curring for 48 hours.The Rates includes prepration of surface, treatment and sealing of all joints, corners, junctions of pipes and masonary with polymer mixed slurry. 175 Providing and layingwater proofing treatment on roofs of slabs by applying cement slurry mixed water proofing cement compound consisting of applying.a) After surface preparation, first layer of slurry of cement @0.488 Kg/Sqm mixed with water proofing cement compound @0.253 Kg/sqmb) Laying of second layer of fiber glass cloth when the first layer is still green.Overlaps of joints of fiber cloth should not be less than @0.253 kg/sqm c) Third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @0.670 kg/sqm and coarse sand @1.289 kg/sqm.This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all aroundd) forth and final layer of brick tiling with cement mortor (Which will be paid for separately)for the purpose of measurement the entire terated suface will be measured. 176 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement incl. cement slurry but excluding the cost of nosing of steps etc complete. 177 40 mm thick with 20 mm nominal size stone agg (Crushed) 178 50 mm thick with 20 mm nominal size stone agg (Crushed) 179 Providing and fixinggang saw cut mirror polished (pre moalded and pre polished) machine cut for kitchen, platform, vanity counters, window sills facias and similar locations of required size of approved shade colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement matching pigment, epoxy touch ups including rubbing moulding and polishing to edge to give high gloss finisg etc complete at all levels. Granite of any colour and shape (area of slab upto 0.50 Sqm) 180 16mm thick 181 Extra for providing edge moulding to 18mm thick marble stone counters, Vanities etc including machine polishing to edge to give high gloss finish etc complete as per design approved by Engineer-in-charge. Granite work 182 Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured) 183 Providing and fixing M.S Grills of required pattern in frames of windows etc with M.S Flats square or round bars etc incl. priming coat with approved steel primer all complete. 184 Fixed to steel windows by welding 185 Fixed to openings / wooden frames 186 Providing and laying vitrified floor tiles in different sizes(thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm 187 Providing & fixing of PVC Panelling (Hard) in walls of approved brand incl. necessary screws & fittings as per directions of Engineer in charge all complete job 188 Supply of labour for repair works 189 Black smith Ist class 190 Carpanter Ist class 191 Carpenter 2nd class 192 Mason Ist class 193 Mason 2nd class 194 Painter 195 Mazdoor 196 Malli 197 Sweeper 198 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared 199 Carriage of material by M.T inclloading/unloading& stacking complete (Carriage to be paid actual) 200 Udhampur Sub Division 201 Sand av. Lead 50 km 202 Stone Av. Lead 10 km 203 Stone agg. Below 40 mm nominal size av. Lead 10 km 204 Stone agg. Above 40 mm nominal size av. Lead 10 km 205 Disposal of mulba 1 km 206 Brick av. Lead 71 km 207 Brick tile av. Lead 71 km

Key Value

Document Fees
INR 600 /-
EMD
INR 30000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail