Tender For Electrical Improvement Work And Installation Of Electrical Equipment At Inspection House Meerut - S/F of following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch 2 Same as above but for 2 way 5/6 A switch 3 Same as above but for 15/16 A switch 4 Same as above but for 3 pin 5/6 A socket outlet. 5 Same as above but for 6 pin 15/16 A socket outlet. 6 Same as above but for Bell push 7 supply and fixing following size modules, GI box along with modular base and cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mm×75mm) 8 Same as above but for 3 Module (100mm×75mm) 9 Same as above but for 4 Module (125mm×75mm) 10 Same as above but for 6 Module (200mm×75mm) 11 Same as above but for 8 Module (125mm×125mm) 12 Same as above but for 12 Module (200mm×150mm) 13 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, power painted including earthing etc. as required. (But Without MCB/RCCB/Isolator)4 way (4+12), Double door 14 Supplying and fixing 12 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, power painted including earthing etc. as required. (But Without MCB/RCCB/Isolator) Complete in all respect. 15 Supply and fixing 5 A to 32 A rating, 240/415V, 10KA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole. Complete in all respect. 16 Supply and fixing 40/63 Amp rating, double pole, 240 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. complete in all respect. 17 Supply and fixing 63 Amp rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. complete in all respect. 18 Supply & Installation of 2.0 TR BEE Star rated 5 Star, Invertor Split AC supply single phase 50 Hz 230 Volts with DC Inverter complete in all respect. (Make-Carrier/Voltas)/Equivalent make. Complete in all respect. as per direction of Engineer Incharge. 19 Supply & Installation of 1.5 TR BEE Star rated 5 Star Invertor Split AC supply single phase 50 Hz 230 Volts with DC Inverter complete in all respect. (Make-Carrier/Voltas)/Equivalent makeComplete in all respect. as per direction of Engineer Incharge. 20 S/F of 5 KVA Voltage Stablizer for Air conditioner upto 2TR (130-300V Range) (Make: V Guard/Microtek or Eq make) copper winding complete in all respect. as per direction of Engineer Incharge. 21 S/F of 4 KVA Voltage Stablizer for Air conditioner upto 1.5TR (130-300V Range) (Make: V Guard/Microtek or Eq make) copper winding complete in all respect. as per direction of Engineer Incharge. 22 SITC of Suction/Discharge copper pipe line in split A.C. Unit 1.5 Ton capacity including brazing, nitrile, rubber insulation 6mm thick class O etc complete 1/4 (6.40 mm) and 1/2 (12.70 mm) Complete in all respect. as per direction of Engineer Incharge. 23 SITC of Suction/Discharge copper pipe line in split A.C. Unit 2 Ton capacity including brazing, nitrile, rubber insulation 6mm thick class O etc complete 3/8 (9.50 mm) and 5/8 (15.90 mm) Complete in all respect. as per direction of Engineer Incharge. 24 S/I of Heavy duty PVC Plastic bralded 20 mm OD flexible pipe for condensed water drain with clipping accessories complete in all respect. as per direction of Engineer Incharge. 25 S/F of 2.5sq mm 3 core PVC insulated round sheathed copper conductor for AC connecting to stabilizer complete in all respect. as per direction of Engineer Incharge. 26 S/F of 2.5sq mm 4 core PVC insulated round sheathed copper conductor for AC connecting indoor/outdoor. complete in all respect. as per direction of Engineer Incharge. 27 Providing and fixing of CPVC pipe with all fitting 25mm dia including all material labour etc complete in all respect as per direction of engineer-in-Charge for drain water 28 S/F of iron Angle Stand for outdoor unit of 1.5 and 2.0 TR solit Air Conditioners Unit. including all material labour, T&P complete in all respect. 29 S/f of LED street light fittingwith mandatory driver set having die cast aluminium body and lense suitable for 90 Wand confirming to IP 66 protection having company LOGO Engraved complete in all respect including labour CAT-AAA 9000-10800system lumans High Power LED with lenses 110 lm@W PF 0.95 THD 10% at full load CRI 70, Potted driver set (Not Circuitory), Phase to Phase Protection at 440 V & 300 V auto cut and restart feature with 5 year warranty. make-crompton/phillips/havells or equivalent. complete in all respect. as per direction of Engineer Incharge. 30 S/F of oil type heater (13 fins) (Make Model : Bajaj Majesty RH 13f plus or equivalent) complete in all respect. as per direction of Engineer Incharge. 31 Supply and Installation of fridge 300 Ltr capacity (Make Model : LG Direct Cool Double Door 300 Ltr 3 Star or eauivalent.) complete in all respect. as per direction of Engineer Incharge. 32 SITC of water cooler with water purification system.including all material labour, T&P, pipe etc. Make Model : Aquaguard RO SS304 or equivalent. Capacity 80 Ltr. Complete in all respect. as per direction of Engineer Incharge. 33 SITC of Inverter 950VA/1 kva sine wave (Make : Sukam, Luminous or equivalent) with Trolley. Complete in all respect. as per direction of Engineer Incharge. 34 S/F of Tubular Battery 150 AH exide make or equivalent. (3 for New invertor and 2 for existing) Complete in all respect. as per direction of Engineer Incharge.