| 1 | Supply & fixingin replacement of new generation energy saving and environmental friendly long life LED street light 35 watt made up of pressure dia cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening separate driver compartment with IP66 protection and impact resistance of IK07by using 2 core PVC insulated cable aluminium conductor 2.5 Sqmm approx 2 m length complete all as specified and directed. |
| 2 | All as per item No.1 above but but ofLED street light 45 watt. |
| 3 | All as per item No.1 above but but ofLED street light 60 watt. |
| 4 | All as per item No.1 above but but ofLED street light 70 watt. |
| 5 | All as per item No.1 above but but ofLED street light 90 watt. |
| 6 | Supply & fixing in replacement ofenergy saving, environmental friendly, long life , exclusive innovate die-cast aluminiumLED floodlight 100 watt as light source, suitable for highlighting architectural features or area lightingby using 2 core PVC insulated cable aluminium conductor 2.5 Sqmm approx 2 m length complete all as specified and directed. silicon pottet gel driver with 10kv SPD & 4KV external driver with BIS Approved/ 110 Lumen/watt. |
| 7 | Supply & fixing in replacement ofnew generation, LED 20 WPost Top Lantern, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LED as light source by using 2 core PVC insulated cable aluminium conductor 2.5 Sqmm approx 2 m length complete all as specified and directed. |
| 8 | Taking down the unserviceable any defective LED street/security light/flood light fittingof any type, make and wattage from the pole alongwith fixing arrangements complete, upto 100 watt capacity from any height of pole or building, servicing, cleaning thoroughly of the fitting including bracket, arm and pole fixing arrangement.Supply and replace the minor spares such as PVC tape, PVC insulated copper wire with in the fittings screws bolts, nuts washers required to make the fitting serviceable and refixing in position after repair and testing for satisfactory functioning. Note for item :(8)Spares for LED street light/ flood light like PCB, circuit board and LED driver shall be measured and paid separately under relevant items of this schedule.All other items of minor spares such asPVC insulated copper conductor cable with in fitting of wiring and necessay bolts and nuts shall be deemed to be included in the item rate and no extra payment shall be allowed. (b) The contractor has to depute his accredited representative with one electrician once in week or as demanded by department to carry out jointly checking of street/security lights in the entire area under Mil Stn Agartalato ascertain the serviceability and repairs required.The item is deemed to be inclusive of the same.(c) The rate quoted deemed to included for cleaning of vegitation on the LT pole and Electric supply made available at the point of street light . (d)The measurement for payment shall be made as per the actual replacement of accessories. (e) No extra cost will be paid to the contractor for T&P and tradesmen as required. (f) Taking down the fittings as required for maintenance for cleaning or minor repairs such as screws wires,carbon removing, taking down etc the cost of same is deemed to be included in the quoted rate. (g) The contractor shall depute one electrician and two helpers on all working days in MES complaint cell for attending the complaint regarding the street/Securitylights. (h) Contractor or his accredited representative is responsible to receieve complaints from JE I/C andfeed back of the same after completion of the job on daily basis. |
| 9 | Supply only LED security light Driver 36 Watt to 100Watt, voltage range 100 to 265 Power factor .98 and Efficiency 92% single phase, power factor complete all as specified and directed |
| 10 | Supply only LED security light PCB circuit board, 36 Watt to 100Watt 50Hz complete all as specified and directed. |
| 11 | Taking up old unsv LT UG cable of any size from trenches/road /floor/poles & wall complete all as specified and directed. |
| 12 | Material & labour for XLPE insulated heavy duty armoured LT under ground cable of size 10 Sqmm, 4 core 1100 V grade PVC insulated ,PVC sheathed ,multi stranded aluminiumcable of following size inpipe /trench /cable duct /fixed on wall by proper size shaped GI clamps with nut bolts etc including aluminium lugs at ends of cable and making good the disturbed surfaces complete all as specified and directed. |
| 13 | Excavating in trenches not exceeding 1.5m wide and not exceeding1.5 mtr in depth/ width for laying under ground cable / foundations and getting out in soft / loose soil all as specified and directed. |
| 14 | Returning, filling in incl spreading, leveling, watering and well ramming in layers not exceeding 25cm all as specified and directed. |
| 15 | Removing of surplus excavating material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed. |
| 16 | Material & labour for sand cushioning for protection of PVC cable with screen wash sand and punning to proper reqd cover all as specified and directed. |
| 17 | Supply & Fixing bricks well burnt sub class ‘B’ bricks in trenches on cable as cable protection across the length of the cable (width wise) complete all as specified and as directed. |
| 18 | Material & labour for 40mm bore galvanized tube (light grade) with all fittings (if required)laid in road crossing or along poles with clamps for protection of UG cable complete all as specified and directed. |
| 19 | Material & labour for three core (for phase , neutral and earth) multistandred aluminium cable 2.5 Sqmm size, 1100 volt grade, PVC insulated unsheathed, cable drawing insteel tubular poles from junction box to street light fitting and testing complete all as directed. |
| 20 | M & L for replacement of rusted/corroted security light bracket made out of GI pipe of light grade1.5 RMx40mm dia and 0.3RM x32 mm dia at one end for inserting of light fitting, properly shaped, bended, & fixed on the pole through MS flat by nut,bolt & washer of suitable sizes incl two coat synthetic enameled paint ,dismantling the old unsv existing one complete all as specified and directed. |
| 21 | Supply and fixingin replacementoutdoor type cable entry junction box of size 205 x 255 x 112 mm, weather proof with knockouts for cable entry- black colour with necessary cable connector link inside the box and fixing arrangement by clamp, nut bolts etc fixied on pole/ walls complete all as specified and as directed. |
| 22 | Material & labour for replacement of 3 pole power contactorof 40 Amp, AC-3 duty rating at 415 Volt, 50 HZ on existingpanel after replacement of old burnt contactor, cutting / thimbling old burnt cable complete all asspecified and directed. |
| 23 | Material & labour for replacement of digital time switch 24 hrs dial (SST- 15 min) single phase 110-240 Volt on existingpanelcomplete all as specified and directed. |
| 24 | S&F solid state electronic type Aviation obstruction light fittings with lamp of minimum 302 LED with cast aluminiumalloy poly carbonate red colour and connecting up and testing complete on top of the hill/tower/over head reservior and other high rise buildings all as directed by Engr-in-charge.(Note: Deployment of technicians to climb up/down for repair/replacement works with proper safety eqpts is the responsiblity of the contractor) |
| 25 | NOTES :-1.The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum.2.Unless otherwise specified the rates for PCC shall deemed to include the cost of formwork shuttering etc, required for complete and proper execution of the work. Refer Schedule \"A\" notes for details. |