Tender For Rate Contract For Supply, Installation Of Pump Set On Various Sources Of Sub Division Delwara - Providing, Installation, Testing And Commissioning Of Centrifugal Monoblock Pump Set Conforming To Is 9079 , 2 Pole Motor Operating At Synchronised , nathdwara-Rajasthan

Public Health Engineering Department has published Tender For Rate Contract For Supply, Installation Of Pump Set On Various Sources Of Sub Division Delwara - Providing, Installation, Testing And Commissioning Of Centrifugal Monoblock Pump Set Conforming To Is 9079 , 2 Pole Motor Operating At Synchronised . Submission Date for this Tender is 28-04-2025. Submersible Pump Tenders in nathdwara Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

48688882
Tender For Rate Contract For Supply, Installation Of Pump Set On Various Sources Of Sub Division Delwara - Providing, Installation, Testing And Commissioning Of Centrifugal Monoblock Pump Set Conforming To Is 9079 , 2 Pole Motor Operating At Synchronised
Open Tender
Indian
Rajasthan
Nathdwara
28-04-2025

Tender Documents

Tender Details

Tender For Rate Contract For Supply, Installation Of Pump Set On Various Sources Of Sub Division Delwara - Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at synchronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected onC.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. 2 Centrifugal Monoblock Pump set (Single Stage) 3 2.2 KW (3.0 HP) 4 3.7 KW (5.0 HP) 5 5.5 KW (7.5 HP) 6 7.5 KW (10 HP) 7 9.3 KW (12.5 HP) 8 11.0 KW (15 HP) 9 15.0 KW (20.0 HP) 10 18.5 KW (25.0 HP) 11 Centrifugal Monoblock Pump set (Double Stage) 12 3.7 KW (5.0 HP) 13 5.5 KW (7.5 HP) 14 7.5 KW (10.0 HP) 15 9.3 KW (12.5 HP) 16 11.0 KW (15.0 HP) 17 15.0 KW (20.0 HP) 18 Vacuum Pump set (Monoblock) 19 Providing, installation, testing and commissioning of Mono block Vacuum pump set with base plate including C.C. foundation / cross channels / RSJ frame and foundation bolts etc. complete in all respect as perspecification, scope of work and direction of Engineer in Charge. 20 0.75 KW (1 HP), single Ph 21 2.2 KW (3 HP), three Ph 22 Vacuum Pump set (Coupled) 23 Providing, installation, testing and commissioning of Vacuum pump set with horizontal foot mounted TEFC squirrel cage motor working on three phase 50 Hz, 415 Volts +/- 10% with base plate including cost of flexible couplings, coupling guard etc. complete in all respect as perspecification, scope of work and direction of Engineer in Charge. 24 3.7 KW (5.0 HP) 25 7.5 KW (10.0 HP) 26 Providing, installation, testing and commissioningof Submerged Centrifugal Pump sets with motor 4 pole synchronised speed of 1500 rpm ( water immersed, dry air filled, class F insulated TEWC motor integrally mounted on volute casing pump sets for drinking water ) 3 phase, +/- 3%, 415 volt +/- 10%, along with suitable foundation/ installation device and with 10 mtr cable, material of construction of impeller SS, casing (volute) CI, wearing ring SS, etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. 27 15 KW 28 18.5 KW 29 22 KW 30 Providing, installation, testing and commissioning of submersible Monoblock pump set conforming to IS 8034 and2 pole motor operating at synchronised speed of speed 3000 RPM, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fibre bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturers design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. 31 2.2 KW (3.0 HP) 32 3.7 KW (5.0 HP) 33 5.5 KW (7.5 HP) 34 7.5 KW (10 HP) 35 9.3 KW (12.5 HP) 36 11.0 KW (15 HP) 37 15.0 KW (20.0 HP) 38 Providing, installation, testing and commissioning of submersible dewatering pump set conforming to relevant IS codes and as per scope of work and Technical Specifications, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft, impeller, pump and motor body. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard. The pump set shall be suitable for direct coupling, with suitable suction strainer etc. completein all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditionsmentioned in TD. 39 0.75 KW (1.0 HP) 40 1.5 KW (2.0 HP) 41 2.2 KW (3.0 HP) 42 3.7 KW (5.0 HP ) 43 Supply & Installation of single phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. 44 Up to 2.0 KW 45 Above 2.0 KW 46 Supply & Installation of 3 phase ISI marked submersible motor pump set ofthree star or better rating of BEEand as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. 47 Up to 5.5 KW (7.5 HP) & head up to 120 mtr. 48 Up to 5.5 KW (7.5 HP) & head above 120 mtr. 49 7.5 KW (10 HP) & head up to 120 mtr. 50 7.5 KW (10 HP) & head above 120 mtr. 51 9.3 KW (12.5 HP) & head up to 120 mtr. 52 9.3KW (12.5 HP) & head above 120 mtr. 53 11 KW (15 HP) & head up to 120 mtr. 54 11 KW (15 HP) & head above 120 mtr. 55 13 KW (17.5 HP) & head up to 120 mtr. 56 13 KW (17.5 HP) & head above 120 mtr. 57 15 KW (20 HP) and above, head up to 120 mtr. 58 15 KW (20 HP) and above, head above 120 mtr. 59 Supply and Fixing of Electric feeder panel (having projected canopy)for submersible pump set Single phase up to 5 HP, comprising of DOL Starter, MCB, Indicating Light, Ammeter, Volt meter, connection plate, condensers of approved make and the panel enclosure should be made out from 18 gauge M.S. Sheet with powder coating. Panel size Height 600 mm Width 500 mm depth 250 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18 and double door including in built locking system.The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The operation of panel should be suitable for on 240 Volt AC Supply. 60 Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB, DOL starter, overload relay, ampere meter, volt meter, phase preventer,phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 300mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18 and double door including in built locking system.The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level.The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. 61 Up to 5.00 HP 62 Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc. complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18 and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. 63 Above 5 HP and up to 10 HP 64 Above 10 HP and up to 15 HP 65 Above 15 HP and up to 20 HP 66 Above 20 HP and up to 30 HP 67 Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc. 68 3 core 4.0 Sq.mm 69 3 core 6.0 Sq.mm 70 3 core 10.0 Sq.mm 71 3 core 16.0 Sq.mm 72 Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 73 10.0 Sq.mm, 4 core 74 16.0 Sq.mm, 4 core 75 25.0 Sq.mm, 3.5 core 76 35.0 Sq.mm, 3.5 core 77 Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set. 78 Supply & Fixing tube well coverof MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2 (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. 79 125 mm dia 80 150 mm dia 81 200 mm dia 82 250 mm dia 83 Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. 84 32 mm dia 85 50 mm dia 86 65 mm dia 87 80mm dia 88 Providing & Lowering in tube well ISI marked HDPE pipe as per IS 4984:1995 or amended up to date in PE 80 grade and class PN 10 of following dia. including HDPE/GI fittings and PVC rope confirming to IS 5175:1992 or amended up to date, along with clamping of submersible cable etc. complete in all respect. 89 40 mm dia 90 50 mm dia 91 63 mm dia 92 75 mm dia 93 90 mm dia 94 Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended up to date of approved make including cost of all material andlabouras per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia. 95 50 mm dia 96 65 mm dia 97 80 mm dia 98 Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizes 99 65 mm dia 100 80 mm dia 101 Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg.including all jointing material as per specification with safety cover. 102 Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixinginpositionatalllevel/ depths in trenches complete includingall taxes, material,labour, inside lining, outside coating, testingandcommissioning alongwithpipelineaspertechnicalspecifications anddirection of Engineer-in-charge. 103 MS pipespecialsup to600mmdia (withminimum5mmthickness sheet) 104 MS pipe specials above 600mm dia(with minimum 6.3mm thickness sheet) 105 SITC of Bulk Flow Meter with removable mechanism class B confirming to ISO:4064:2005/ IS: 2373of approved make of following dia sized pipelines and specifications complete:Media : Water (Clear ), Temp. 50 deg., Pr. rating: PN16, Protection type: IP- 68,Body Material : IS-210 Gr. FG-200, Accuracy Class :Class B (±2 % @ Nominal flow rate), Magnetic Drive,Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. 106 BFM 80 mm 107 BFM100 mm 108 BFM125 mm 109 BFM 150 mm

Key Value

Document Fees
INR 2000 /-
EMD
INR 56000.0 /-
Tender Value
INR 28 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail