Tender For Work Of Conversion Handpump Scheme To Piped Scheme Solar Based At Various Villages In Region Udaipur To Provide Fhtc Including One Year Dlp On Spr Basis Under Jjm--- 1 DISTT PRATAPGARH (Dhariyawad and Chotisadri) 2 Provision for construction of Sources 3 Construction of Tube Well up to 100 mtr. depthin all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended upto date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a throughout bore as per nominal dia of casing pipe. 4 Nominal bore 150 mm dia. 5 Nominal bore 200 mm dia. 6 Add 15% extra on above item for drilling depth beyond 100 mtr, If depth of Tube well is more than 100 mtr. 7 Nominal bore 150 mm dia. 8 Nominal bore 200 mm dia. 9 Testing verticality of tube well by plumbing system and yield test and draw down test by pumping system as per IS : 2800 (Part – II) – 1979 or as per amended up to date. 10 Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to dateoffollowing sizes 11 150 mm dia NB(Thickness of pipe 5.0 mm & mass of tube 20.13 Kg/m) 12 200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m) 13 Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS:8110-1985. 14 150 mm dia nominal bore of 4.8 mm thickness 15 200 mm dia nominal bore of 4.8 mm thickness 16 Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc. 17 3 core 4.0 Sq.mm 18 3 core 6.0 Sq.mm 19 Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 20 10.0 Sq.mm, 4 core 21 Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc for holding the riser pipe assembly of submersible pump set. 22 Providing & Lowering in tube well ISI marked HDPE pipe as per IS 4984:1995 or amended upto date in PE 80 grade and class PN 10 of following dia. including HDPE/GI fittings and PVC rope confirming to IS 5175:1992 or amended upto date, along with clamping of submersible cable etc. complete in all respect. 23 40 mm dia 24 Provision for Solar panel, motor pump, over head tank on MS fabricated struture 25 Supply, installation, testing and commissioning ofMNRE approved off GridSolar Panels for running of motor pumps with 25 years of Linear Generation warranty, Work includes designing of solar panel area and structure, showing arrangement of panel on rectangular OHSR with flat roof/ MS fabricated structure with polyethylene tank and installation ofPV module on above structure as per approved design and drawings. Mountingstructure shall be suitably designto withstand wind velocity up to 150km/hr. The work shall be as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge. This item does not include cost of OHSR/ MS fabricated structure with tank but includes cost of items required for installation of solar panels on top of the tank.Note: There shall be 5 year service warranty for solar panel and mounting structureandsuitable provision shall be included in tender document. 26 Providing, installation, testing and commissioning of AC submerssible pump sets with inbuilt or individual solar pump controllerwith Maximum power point tracking (MPPT) for optimally use the solar panel and maximize water discharge to deliver maximum water during the day including PVC flat submersible cable from controller to motor pumps..Solar pumpshall be of Stainless steel construction and performance shall be as per scope of work and minimum lift of water shall be as per defined in scope .Pump controller shall have Adequate protection against dry operation of motor pump set, and against hails and storms. Full protection against open circuit, accidental short circuit and reverse polarity should be provided. A good reliable on/off switchbe provided. The cable shall be ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date ( standard insulation) and conductor as per class 5 of IS 8130:1980 or amended up to date.The duty condition of pump set shall be as per scope of work and entire work shall be executed as per technical specification and direction of Engineer in charge. 27 1.5 KW (2.0 HP) 28 2.2 KW (3.0 HP) 29 3.7 kw (5.0 HP) 30 Supply, installation, testing and commissioning of Remote monitoring unit on off grid solar controller for remote ON/OFF, parameter setting, monitoring and troubleshooting through mobile etc. complete. Web charges and data charges for 5 year during service warranty etc. complete in all respect as per technical specification and as per direction of Engineer. 31 Providing, installation, testing and commissioning structural steel work riveted or bolted in built up sections, trusses and framed work, including cutting, hoisting for following staging and capacity of Rotational Moulded Polyethylene water storage tank on it as per indicative drawing given in the bid document. On thePolyethylene tanks, there shall be provision of suitable space for installation of solar panels up to 5.0 KW and further additional 2.5 KW on the side of Steel structure if required as per indicative drawing. Cost of solar panels is not included in this item . The structural steel shall be 120 micron hot dip galvanized iron and foundation of structure shall be in RCC with minimum depth as 2.0 mtr (other than rocky strata). The work includes P&F of Polyethylene Water Storage Tank(IS: 12701,ISI marked, indicating the BIS license No.) of approved make with cover. Providing & fixing 50 mm dia ISI marked G.I. class B pipe for inlet, outlet and over flow pipe and 32 mm GI class B pipe for wash out with GM gate valves at inlet and outlet pipe Including making connection etc. complete as per drawing, technical specification and direction of Engineer in In charge. The scope includes inlet GI pipe from ground level to water tank and outlet pipe from water tank to ground and up to 2.0 mtr away from foundation and overflow pipe is to be interconnected in distribution pipe line. Wash out pipe shall be taken up to a suitable point minimum 5.0 mtr away from tank. Water level controller shall installed to monitor level in tank and shall automatically shut off motor when tank is filled . 32 Note: There shall be 5 year service warranty for structure, tank, fittings etc. andsuitable provision shall be included in tender document. 33 5000 Liter X 2 Nos. PE water tank , staging 12 meter. 34 5000 Liter X 2 Nos. PE water tank , staging 10 meter. 35 7500 Liter X 2 Nos. PE water tank, staging 12 meter. 36 SITC of Bulk Flow Meter with removable mechanism class B confirming to ISO:4064:2005/ IS: 2373of approved make of following dia sized pipelines and specifications complete:Media : Water (Clear ), Temp. 50 deg., Pr. rating: PN16, Protection type: IP- 68,Body Material : IS-210 Gr. FG-200, Accuracy Class :Class B (±2 % @ Nominal flow rate), Magnetic Drive,Dry Dial, Epoxy powder coated, Pulse out put option, Anti-magnetic protection including all materials and making connection with existing pipeline required for Bulk Flow Meter including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. 37 BFM 80 mm 38 Providing and fixing of flanged/plain ended MS specials from MS sheet strips of relevant IS specification of approved thickness by welding , lowering, laying and aligning, fixing in position at all level/depths in trenches complete including all taxes, material , labour, inside lining, outside coating , testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-chargeMS pipe special upto 600mm dia (with minimum 5.0 mm thickness sheet) 39 HDPE PE-80PN-6 40 75 mm dia 41 90 MM DIA 42 Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing type Non Return Valves (NRV)of approved make of following Pressure rating & dia complete, confirming to IS: 5312 (part -1)/ 2004 (amendedup to date) and of following specifications: Body, Cover & disc of Grey cast iron of IS:210/ FG200. Face to face dimensions as per IS 5312 (part -1):2004 , Flanges Drilled as per IS:1538. All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660and two coats of black Japan paints conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside. Body seat ring of SS/CS Door face ring - EPDM/ Neoprene (food grade quality) ,Shaft of HTB1/ SS- AISI- 410, Hinge Malleable cast iron / SS AISI 316/410 ,Bonnet Gasket EPDM, Bush- Leaded tin Bronze/ PTET, GasketEPDM/NBR,Nut-Bolt as per IS:1363 and IS: 1367 (galvanised steel) ,Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 43 80 mm dia Class PN 1.0 44 Providing & Lowering in tube well ISI marked GI Pipe “B class as per IS:1239 or amended up to date threaded and double flanged (welded) on both ends and two number25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. 45 50 mm dia 46 32 mm dia 47 Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixinginpositionatalllevel/ depths in trenches complete includingall taxes, material,labour, inside lining, outside coating, testingandcommissioning alongwithpipelineaspertechnicalspecifications anddirection of Engineer-in-charge. 48 MS pipespecialsupto600mmdia (withminimum5mmthickness sheet) 49 Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 50 Manually Operated Resilient Seated Sluice Valves of Class PN 1.0/1.6 51 80 mm dia PN 1.6 52 100 mm dia PN 1.6 53 150 mm dia PN 1.6 54 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches for water supply pipe lines,shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete forlifts up to 1.5 depth and strata as specified. The work also includesdepositing and refilling of trench with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed for lead up to 50 mtr. 55 In all type of soil 56 In soft Rock 57 In Hard Rock (Required blasting) 58 In Hard Rock (Blasting prohibited) 59 Dismantling of cement concrete pavement for pipe lineand chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shallbe made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. 60 Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. 61 M10 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). 62 M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). 63 Providing, lowering,aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specificationscompleteofthefollowingsizesincludingall jointing material,costofalllabour,testingandcommissioningand as per technical specifications and direction of Engineer In-Charge. Class PN 1.0/1.6 64 Dia (mm) PN rating 65 80 1.6 66 Construction of RCC Valve Chamber(unit estimate attaced) 67 Earth work in excavation in foundationtrenches or drains including dressing of sides and ramming of bottons, lift upto 1.5 mt. including taking the excavated soil and depositing the refilling of Jhiri with watering and ramming and disposal of surplus excavated soil as directed within lead of 50m. 68 All kind ofsoil. 69 Ordinary Rock 70 Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg.including all jointing material as per specification with safety cover. 71 180cm high fencing with angle iron post 55x55x6mm. placed at every 3Mtr. apart 45cm. in ground embedded in cement concrete 1:3:6 (30x30x60cm) corner and every tenth post to be strutted with 55x55x6mm. angle iron provided with 6 horizontal lines and two diagonals of black barbed wire between two posts fitted and fixed with G.I. staples including earth work in excavation etc. complete. 72 Providing and laying in position cement concrete including curing compaction etc complete in specified grade excluding the cost of centering and shuttering-All work up to plinth level. using crusher broken aggregate. 73 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). 74 Centering&shutteringwithplywood or steel sheetsincludingstruttings proppingbracing bothwayswithwoodenmembersremovalofform work forup to floor three level for: Walls ( any thickness) including attached pilaster buttresses , plinth and string course 75 Centering&shutteringwithplywood or steel sheetsincludingstruttings proppingbracing bothwayswithwoodenmembersremovalofform work forup to floor three level for: Suspended floor, roofs, landings, staircases, balconies girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chajjas, lintels, beams etc. 76 RCCworkincluding atteched pilasters ,buttresses, plinth and string coureses, fillets,columns,pillers, abutements, posts etc. upto floor three level including curing,compaction,finishing 1:1.5:3.(M-20). 77 Providing and fabricatting reinforcement for RCC work including straightening, cutting, bending, and placing in position in binding (including cost of binding wire) All complete up to floor Three level. Thermomechanically Treated bars (Conforming of relevent IS code) 78 Valves for pipe line 79 Providing, lowering, aligning, fixing in position in pipe line at work site,DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves), Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN- 1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS:1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick.Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tailpiece/ dismantling joints and earth work. 80 Manually Operated Resilient Seated Sluice Valves of Class PN 1.0/1.6 80 mm dia 81 Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer. Class PN 1.0 80 mm dia 82 Construction of CWT in village (1.5x3.0 mtr) 83 Earth work in excavation over areas (exceeding 30 Cm. In depth, 1.5 Mtr. in width as well as 10 Sqm. on plan) including disposal of excavated earth lead up to 50 M and lift up to 1.5 Mtr. disposed earth to be leveled and neatly dressed:All kinds of soil 84 Providing and laying in position cement concrete including curing compaction etc . Complete in specified grade excluding the cost of centering and shuttering. All work up to plinth level using crusher broken aggregate 85 Providing and fabricating reinforcement for R.C.C. work including straightening,cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. a) Hot-rolled defomred bars (IS:1139) 86 Centering and shuttering with plywood or steel sheets including strutting, propping, bracing both ways and removal of formwork for foundations in basements rafts, footings, strap beams, bases of columns , etc. up to plinth level. 87 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix 88 Providing and fixing full way valve(IS778 marked) or wheel valve of approved marked. gun matel 32mm nominal bore 89 Provision for FHTCs 90 Providing Household Tap Connectionas per technical specification and approved drawing as per relevant IS code (amended up to date) from uPVC/DI/AC/MS/GI pipe line up to consumer meter/premises by using PVC/MS saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil (excluding road); depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance withspecification for potable water including MS/PVC saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or wheel valveand specials, below ground level 20 mm nominal dia MDPE pipe PE80 PN 16 as per ISO 4427 / 20 mm nominaldia PPR-C (Three layered) pipePN16 SDR 7.4 (IS:15801:2008) (ISI mark) and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia GI pipe with fittings in the premises for fixing a tap / meter box (excluding),including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level.Note: Road cut and restoration is not part of this item and paid seperately. 91 For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr. 92 Providing Household Tap Connectionas per technical specification andapproved drawing and as per relevant IS code (amended up to date) from HDPE pipe line up to consumer meter/premises by using electro fusion saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance withspecification for potable water including electrofusion saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or wheel valve and specials, below ground level 20 mm nominal dia MDPE pipe PE80 PN 16 as per ISO 4427 / 20 mm nominaldia PPR-C (Three layered) pipePN16 SDR 7.4 (IS:15801:2008) (ISI mark) for and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia GI pipes with fittings in the premises for fixing a tap / meterbox (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level.Note: Road cut and restoration is not part of this item and paid seperately. 93 For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr. 94 P& F Bib cock (IS : 8931 mark), superior quality of approved make , brss 400 gm, 15 mm nominal bore. 95 Road cutting for house hold service connection in minimum trench width whereever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be doneby using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge.. 96 Add extra over item no 1.21 & 1.22 for providing20 mm PE80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr. 97 DISTRICT DUNGARPUR 98 Construction of 150 mm dia and 120 meter deep tube well. 99 Construction of tube well from ground level and upto 100 mtr. depth and above in all type of soils and overburden by DTH system as per IS : 2800 (Part I & II) 1979 as amended up to date to accommodate casing pipe of following sizes but excluding cost of casing pipe. The work would be completed after obtaining sand free water. The tube well should have a throughout bore as per nominal bore of casing pipe 200 mm dia nominal bore. 100 Add 15% extra on above item for drilling depth beyond 100 mtr, If depth of Tube well is more than 100 mtr. 101 Supply of ERW M.S. black casing pipe ISi marked (IS: 4270/2001) or amended up to date of grade Fe 41 O of following sizes. 200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m) 102 Supply & Fixing tube well coverof MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2 (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. 103 150 mm dia 104 Providing, commissioning ofSolar based water supply systemTW 105 Supply, installation, testing and commissioning of MNRE approved off Grid Solar Panels for running of motor pumps with 25 years of Linear Generation warranty, Work includes designing of solar panel area and structure, showing arrangement of panel on rectangular OHSR with flat roof/ MS fabricated structure with polyethylene tank and installation of PV module on above structure as per approved design and drawings. Mounting structure shall be suitably design to withstand wind velocity up to 150km/hr. The work shall be as per detailed technical specifications, approved drawing and direction of Engineer in Charge.This item does not include cost of OHSR/ MS fabricated structure with tank but includes cost of items required for installation of solar panels on top of the tank.Note: There shall be 5 year service warranty for solar panel and mounting structure and suitable provision shall be included in tender document. 106 Supply, installation, testing and commissioning of MNRE approved off Grid Solar Panels for running of motor pumps with 25 years of Linear Generation warranty, Work includes designing of solar panel area and structure, showing arrangement of panel on rectangular OHSR with flat roof/ MS fabricated structure with polyethylene tank and installation of PV module on above structure as per approved design and drawings. Mounting structure shall be suitably design to withstand wind velocity up to 150km/hr. The work shall be as per detailed technical specifications, approved drawing and direction of Engineer in Charge.This item does not include cost of OHSR/ MS fabricated structure with tank but includes cost of items required for installation of solar panels on top of the tank.Note: There shall be 5 year service warranty for solar panel and mounting structure and suitable provision shall be included in tender document. 107 Supply, installation, testing and commissioning of DC submerssible pump sets with inbuilt or individual solar pump controller with Maximum power point tracking (MPPT) for optimally use the solar panel and B9maximize water discharge to deliver maximum water during the day including PVC flat submersible cable from controller to motor pumps.Solar pump shall be of Stainless steel construction and performance shall be as per scope of work and minimum lift of water shall be as per defined in scope. Pump controller shall have Adequate protection against dry operation of motor pump set, and against hails and storms. Full protection against open circuit,accidental short circuit and reverse polarity should be provided. A good reliable on/off switch suitable for DC use is to be provided. The cable shall be ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date ( standard insulation) and conductor as per class 5 of IS 8130:1980 or amended up to date.The duty condition of pump set shall be as per scope of work and entire work shall be as per technical specification and direction of Engineer in charge. 1.5 KW (2.0 HP) 108 Supply, installation, testing and commissioning of DC submerssible pump sets with inbuilt or individual solar pump controller with Maximum power point tracking (MPPT) for optimally use the solar panel and B9maximize water discharge to deliver maximum water during the day including PVC flat submersible cable from controller to motor pumps.Solar pump shall be of Stainless steel construction and performance shall be as per scope of work and minimum lift of water shall be as per defined in scope. Pump controller shall have Adequate protection against dry operation of motor pump set, and against hails and storms. Full protection against open circuit,accidental short circuit and reverse polarity should be provided. A good reliable on/off switch suitable for DC use is to be provided. The cable shall be ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date ( standard insulation) and conductor as per class 5 of IS 8130:1980 or amended up to date.The duty condition of pump set shall be as per scope of work and entire work shall be as per technical specification and direction of Engineer in charge. 2.2 KW (3.0 HP) 109 Providing, installation, testing and commissioning structural steel work riveted or bolted in built up sections, trusses and framed work, including cutting, hoisting for following staging and capacity of Rotational Moulded Polyethylene water storage tank on it as per indicative drawing given in the bid document. On the Polyethylene tanks, there shall be provision of suitable space for installation of solar panels up to 5.0 KW and further additional 2.5 KW on the side of Steel structure if required as per indicative drawing. Cost of solar panels is not included in this item. The structural steel shall be 120 micron hot dip galvanized iron and foundation of structure shall be in RCC with minimum depth as 2.0 mtr (other than rocky strata). The work includes P&F of Polyethylene Water Storage Tank(IS: 12701,ISI marked, indicating the BIS license No.) of approved make with cover.Providing & fixing 50 mm dia ISI marked G.I. class B pipe for inlet, outlet and over flow pipe and 32 mm GI class B pipe for wash out with GM gate valves at inlet and outlet pipe Including making connection etc. complete as per drawing, technical specification and direction of Engineer in In charge. The scope includes inlet GI pipe from ground level to water tank and outlet pipe from water tank to ground and up to 2.0 mtr away from foundation and overflow pipe is to be interconnected in distribution pipe line. Wash out pipe shall be taken up to a suitable point minimum 5.0 mtr away from tank. Water level controller shall installed to monitor level in tank and shall automatically shut off motor when tank is filled. Note: There shall be 5 year service warranty for structure, tank, fittings etc. and suitable provision shall be included in tender document. 7500 Liter X 2 Nos. HDPE water tank, staging 12 meter. 110 P & F Gun-metal Non-return Valve or Check Valve (IS :Make) of approved make, superior quality: 111 50mm nominal bore.Horizontal 112 50mm nominal bore.Horizontal 113 P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make : 114 Gun-metal 50mm nominal bore. 115 40 mm dia (horizontal) 116 Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc. 117 3 core 4.0 Sq.mm 118 Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 119 10.0 Sq.mm, 4 core 120 Providing & Lowering in tube well ISI marked GI Pipe “B class as per IS:1239 or amended up to date threaded and double flanged (welded) on both ends and two number25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. 121 50 mm dia 122 Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc for holding the riser pipe assembly of submersible pump set. 123 Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended upto date of approved make including cost of all material andlabouras per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia. 124 50 mm dia 125 Supply, installation, testing and commissioning of Remote monitoring unit on off grid solar controller for remote ON/OFF, parameter setting, monitoring and troubleshooting through mobile etc. complete. Web charges and data charges for 5 year during service warranty etc. complete in all respect as per technical specification and as per direction of Engineer. 126 Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg.including all jointing material as per specification with safety cover. 127 120cm high fencing with angle iron post 55x55x6mm. placed at every 3Mtr. apart 45cm. in ground embedded in cement concrete 1:3:6 (30x30x60cm) corner and every tenth post to be strutted with 55x55x6mm. angle iron provided with 6 horizontal lines and two diagonals of black barbed wire between two posts fitted and fixed with G.I. staples including earth work in excavation etc. complete. 128 Providing, commissioning ofSolar based water supply systemTW 129 Supply, installation, testing and commissioning of MNRE approved off Grid Solar Panels for running of motor pumps with 25 years of Linear Generation warranty, Work includes designing of solar panel area and structure, showing arrangement of panel on rectangular OHSR with flat roof/ MS fabricated structure with polyethylene tank and installation of PV module on above structure as per approved design and drawings. Mounting structure shall be suitably design to withstand wind velocity up to 150km/hr. The work shall be as per detailed technical specifications, approved drawing and direction of Engineer in Charge.This item does not include cost of OHSR/ MS fabricated structure with tank but includes cost of items required for installation of solar panels on top of the tank.Note: There shall be 5 year service warranty for solar panel and mounting structure and suitable provision shall be included in tender document. (Each 1.5Kw) 130 Supply, installation, testing and commissioning of DC submerssible pump sets with inbuilt or individual solar pump controller with Maximum power point tracking (MPPT) for optimally use the solar panel and B9maximize water discharge to deliver maximum water during the day including PVC flat submersible cable from controller to motor pumps.Solar pump shall be of Stainless steel construction and performance shall be as per scope of work and minimum lift of water shall be as per defined in scope. Pump controller shall have Adequate protection against dry operation of motor pump set, and against hails and storms. Full protection against open circuit,accidental short circuit and reverse polarity should be provided. A good reliable on/off switch suitable for DC use is to be provided. The cable shall be ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date ( standard insulation) and conductor as per class 5 of IS 8130:1980 or amended up to date.The duty condition of pump set shall be as per scope of work and entire work shall be as per technical specification and direction of Engineer in charge. 1.5 KW (2.0 HP) 131 Providing, installation, testing and commissioning structural steel work riveted or bolted in built up sections, trusses and framed work, including cutting, hoisting for following staging and capacity of Rotational Moulded Polyethylene water storage tank on it as per indicative drawing given in the bid document. On the Polyethylene tanks, there shall be provision of suitable space for installation of solar panels up to 5.0 KW and further additional 2.5 KW on the side of Steel structure if required as per indicative drawing. Cost of solar panels is not included in this item. The structural steel shall be 120 micron hot dip galvanized iron and foundation of structure shall be in RCC with minimum depth as 2.0 mtr (other than rocky strata). The work includes P&F of Polyethylene Water Storage Tank(IS: 12701,ISI marked, indicating the BIS license No.) of approved make with cover.Providing & fixing 50 mm dia ISI marked G.I. class B pipe for inlet, outlet and over flow pipe and 32 mm GI class B pipe for wash out with GM gate valves at inlet and outlet pipe Including making connection etc. complete as per drawing, technical specification and direction of Engineer in In charge. The scope includes inlet GI pipe from ground level to water tank and outlet pipe from water tank to ground and up to 2.0 mtr away from foundation and overflow pipe is to be interconnected in distribution pipe line. Wash out pipe shall be taken up to a suitable point minimum 5.0 mtr away from tank. Water level controller shall installed to monitor level in tank and shall automatically shut off motor when tank is filled. Note: There shall be 5 year service warranty for structure, tank, fittings etc. and suitable provision shall be included in tender document. 5000 Liter X 2 Nos. HDPE water tank, staging 12 meter. 132 P & F Gun-metal Non-return Valve or Check Valve (IS :Make) of approved make, superior quality: 133 50mm nominal bore.Horizontal 134 P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make : 135 Gun-metal 50mm nominal bore. 136 Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc. 137 3 core 4.0 Sq.mm 138 Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 139 10.0 Sq.mm, 4 core 140 Providing & Lowering in tube well ISI marked GI Pipe “B class as per IS:1239 or amended up to date threaded and double flanged (welded) on both ends and two number25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. 141 50 mm dia 142 Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc for holding the riser pipe assembly of submersible pump set. 143 Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended upto date of approved make including cost of all material andlabouras per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia. 144 50 mm dia 145 Supply, installation, testing and commissioning of Remote monitoring unit on off grid solar controller for remote ON/OFF, parameter setting, monitoring and troubleshooting through mobile etc. complete. Web charges and data charges for 5 year during service warranty etc. complete in all respect as per technical specification and as per direction of Engineer. 146 Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg.including all jointing material as per specification with safety cover. 147 180cm high fencing with angle iron post 55x55x6mm. placed at every 3Mtr. apart 45cm. in ground embedded in cement concrete 1:3:6 (30x30x60cm) corner and every tenth post to be strutted with 55x55x6mm. angle iron provided with 6 horizontal lines and two diagonals of black barbed wire between two posts fitted and fixed with G.I. staples including earth work in excavation etc. complete. 148 Providing, Laying & jointing of Distribution Main for water supply to various streets of the village. 149 Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply may be in coil or straight length in 6 M/12 M. 150 HDPE PE-100PN-6,75 mm 151 HDPE PE-100PN-6,90 mm 152 HDPE PE-80PN-6,75 mm 153 HDPE PE-80PN-6,90mm 154 HDPE PE-80PN-6,110mm 155 Earth work in excavation by mechanical means (Hydraulic Excavator )/manual means in trenches for water supply pipe lines, shoring and strutting if required as per required gradient and line including safety provisions using site rails and stacking excavated stuff including up to all required lead cleaning the site etc. complete for lifts up to 1.5 depth and strata as specified. The work also includes depositing and refilling of trench with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed for lead up to 50 mtr. All Kind of Soil 156 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and stacking serviceable material for measurements and disposal of unserviceable material as directed, with in a lead of 50 Mtr. including all safety provisions required .: Ordinary Rock 157 Dismantling of cement concrete pavement for pipe line line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. 158 Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. 159 Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. 160 M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size). 161 Valves for pipe line 162 Providing, lowering, aligning, fixing in position in pipe line at work site,DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves), Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN- 1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS:1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick.Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tailpiece/ dismantling joints and earth work. 163 Manually Operated Resilient Seated Sluice Valves of Class PN 1.0/1.6 80 mm dia 164 Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer. Class PN 1.0 80 mm dia 165 Construction of sluice valve chamber/NRV Chambers (size inner side 1.2x1.2x1.2mtr)-35 Nos. 166 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil 167 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and stacking serviceable material for measurements and disposal of unserviceable material as directed, with in a lead of 50 Mtr. including all safety provisions required .:Ordinary rock 168 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 169 1:4:8 (1 cement 4 coarse sand 8 graded stone aggregate 40mm nominal size) 170 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation in basements rafts, footings, straps beams, bases of columns etc. up to plinth level. 171 Suspended floors, roofs landings staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam etc. 172 Providing and fixing up to floor three level pre cast cement concrete string or lacing courses, copings, bed plates, anchor blocks, windows sills, shelves, louvers steps, staircases, etc. including carriage, hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand) cost of required centering, shuttering and finishing smooth with 6 mm thick cement plaster 1:3 (1 cement : 3 fine sand) on exposed surface, including all T & P, curing etc. complete: 173 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. 174 Supply fixing RCC Manholes covers with frame of aproved make light duty size 600x600mm 175 Providing laying aligning fixing in postiion and jointing CI Dismantaling joint as per IS Specification s class PN 1.0 80mm dia 176 construction of CWT 177 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.:All kinds of soil 178 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 179 1:2:4 (1 cement 2 coarse sand 4 graded stone aggregate 20mm nominal size) 180 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level. 181 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation in basements rafts, footings, straps beams, bases of columns etc. up to plinth level. 182 Providing and fixing up to floor three level pre cast cement concrete string or lacing courses, copings, bed plates, anchor blocks, windows sills, shelves, louvers steps, staircases, etc. including carriage, hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand) cost of required centering, shuttering and finishing smooth with 6 mm thick cement plaster 1:3 (1 cement : 3 fine sand) on exposed surface, including all T & P, curing etc. complete: 183 Providing and fixing full way valve or wheel valve of approved make . Gun matel 32mm nominal bore 184 Functional House Tap Connections ( FHTCs ). 185 Providing Household Tap Connection as per technical specification and approved drawing and as per relevant IS code (amended up to date) from HDPE pipe line up to consumer meter/premises by using electro fusion saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil; epositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance with specification for potable water including electrofusion saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or wheel valve and specials, below ground level 20 mm nominal dia MDPE pipe PE 80 PN 16 as per ISO 4427 / 20 mm nominal dia PPR-C (Three layered) pipe PN16 SDR 7.4 (IS:15801:2008) (ISI mark) for and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia GI pipes with fittings in the premises for fixing a tap / meterbox (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connectioncomplete in all respect including labour charges . The service line should be laid at least 45 cm below ground level. Note: Road cut and restoration is not part of this item and paid seperately. For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr. 186 P& F Bib cock (IS : 8931 mark), superior quality of approved make ,brss 400 gm, 15 mm nominal bore. 187 Road cutting for house hold service connection in minimum trench width whereever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be done by using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge.. 188 Add extra over item no 1 for providing 20 mm PE 80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr. 189 RISING MAIN PIPELINE 190 Providing & Lowering in tube well ISI marked HDPE pipe as per IS 4984:1995 or amended upto date in PE 80 grade and class PN 10 of following dia. including HDPE/GI fittings and PVC rope confirming to IS 5175:1992 or amended upto date, along with clamping of submersible cable etc. complete in all respect. 191 40 mm dia 192 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, dressing of sides and ramming of bottoms, depth up to 1.5 mtr including taking out the excavated soils and then returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed for lead up to 50 mtr including required all safety provisions etc. 193 All kind of soils 194 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, dressing of sides and ramming of bottoms, depth up to 1.5 mtr including taking out the excavated soils and then returning the soil as required in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering etc. and stacking serviceable materials for measurement and and disposable of unserviceable mesurement as directed for lead up to 50 mtr including all safety provisionsrequired 195 Ordinary rock 196 Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. 197 M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mmnominal size). 198 DISTRICT CHITTORGARH (Nimbaheda) 199 Construction of Tube Well 200 Construction of Tube Well up to 100 mtr. depthin all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended upto date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a throughout bore as per nominal dia of casing pipe. 201 Nominal bore 150 mm dia. 202 Add 15% extra on above item (Item No 2.4.1 to 2.4.2) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr. 203 Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to dateoffollowing sizes 204 150 mm dia NB (Thickness of pipe 5.0 mm & mass of tube 20.13 Kg/m) 205 Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc for holding the riser pipe assembly of submersible pump set. 206 Supply & Fixing tube well coverof MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2 (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. 207 150 mm dia 208 Solar Plant and pump Machinery 209 Supply, installation, testing and commissioning ofMNRE approved off GridSolar Panels for running of motor pumps with 25 years of Linear Generation warranty, Work includes designing of solar panel area and MS fabricated structure 120 micron hot dip galvanized iron , showing arrangement of panel in available space and installation ofPV module on frame structure such that minimum height of lower edge of panel shall be 4.0 mtr from ground level to safeguard against damage and theft as per indicative drawing enclosed with the bid document. The foundation of structure shall be in RCC. Mountingstructure shall be suitably designedto withstand wind velocity up to 150km/hr. The work shall be executed as perdetailedtechnical specifications, approved drawing and direction of Engineer in Charge.Note: There shall be 5 year service warranty for solar panel and mounting structureandsuitable provision shall be included in tender document. 210 Providing, installation, testing and commissioning of AC submerssible pump sets with inbuilt or individual solar pump controllerwith Maximum power point tracking (MPPT) for optimally use the solar panel and maximize water discharge to deliver maximum water during the day including PVC flat submersible cable from controller to motor pumps..Solar pumpshall be of Stainless steel construction and performance shall be as per scope of work and minimum lift of water shall be as per defined in scope .Pump controller shall have Adequate protection against dry operation of motor pump set, and against hails and storms. Full protection against open circuit, accidental short circuit and reverse polarity should be provided. A good reliable on/off switchbe provided. The cable shall be ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date ( standard insulation) and conductor as per class 5 of IS 8130:1980 or amended up to date.The duty condition of pump set shall be as per scope of work and entire work shall be executed as per technical specification and direction of Engineer in charge. 211 2.2 KW (3.0 HP) 212 3.7 KW (5.0 HP) 213 Supply, installation, testing and commissioning of remote monitoring unit on off grid solar controller for remote ON/OFF, parameter setting, monitoring and troubleshooting through mobile etc. complete Web charges and data charges for 5 Year during service warranty etc. complete in all respect as per technical specification and as per direction of Engineer. 214 Supply & Fixing XLPE insulated/PVC sheathed cable of 1.1 KV grade with aluminium condutor armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavtion of 30cmx75cm size trench, 25cm thick under layer of sand, second class bricks covering, refelling earth, compaction of earth, making necessary connection, testing etc as required of size. 215 10 Sq.mm,4 core 216 Providing & Lowering in tube well ISI marked HDPE pipe as per IS 4984:1995 or amended upto date in PE 80 grade and class PN 10 of following dia. including HDPE/GI fittings and PVC rope confirming to IS 5175:1992 or amended upto date, along with clamping of submersible cable etc. complete in all respect. 217 50 mm dia 218 Supplying & Installing 100mm dia mtr. Sealed diaphragm burdentypepressuregaugealongwithall jointing materials Range 0 to 15 kg/cm2 including all jointing material as per specification with safety cover. 219 Providing and Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizes. 220 80 mm 221 Providing, installation, testing and commissioning structural steel work riveted or bolted in built up sections, trusses and framed work, including cutting, hoisting for following staging and capacity of Rotational Moulded Polyethylene water storage tank on it as per indicative drawing given in the bid document. On thePolyethylene tanks, there shall be provision of suitable space for installation of solar panels up to 5.0 KW and further additional 2.5 KW on the side of Steel structure if required as per indicative drawing. Cost of solar panels is not included in this item . The structural steel shall be 120 micron hot dip galvanized iron and foundation of structure shall be in RCC with minimum depth as 2.0 mtr (other than rocky strata). The work includes P&F of Polyethylene Water Storage Tank(IS: 12701,ISI marked, indicating the BIS license No.) of approved make with cover. Providing & fixing 50 mm dia ISI marked G.I. class B pipe for inlet, outlet and over flow pipe and 32 mm GI class B pipe for wash out with GM gate valves at inlet and outlet pipe Including making connection etc. complete as per drawing, technical specification and direction of Engineer in In charge. The scope includes inlet GI pipe from ground level to water tank and outlet pipe from water tank to ground and up to 2.0 mtr away from foundation and overflow pipe is to be interconnected in distribution pipe line. Wash out pipe shall be taken up to a suitable point minimum 5.0 mtr away from tank. Water level controller shall installed to monitor level in tank and shall automatically shut off motor when tank is filled . 222 Note: There shall be 5 year service warranty for structure, tank, fittings etc. andsuitable provision shall be included in tender document. 223 5000 Liter X 2 Nos. PE water tank, staging 10 meter. 224 7500 Liter X 2 Nos. PE water tank, staging 10 meter. 225 Providing, lowering, laying and jointing in trenches, standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) .Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.Supply may be in coil or straight length in 6 M/12 M. 226 HDPE PE-80PN-6 227 90 mm dia 228 Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesof approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitablesupport structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 229 Manually Operated CI Sluice valve of Class PN-1.0 230 80 mm HW 231 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.: 232 A. All kind of soil 233 Dismantling of cement concrete pavement for pipe line line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. 234 Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shallbe made for trench width more than specified,complete work as per technical specification and scope of work.M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size). 235 Providing Household Tap Connectionas per technical specification andapproved drawing and as per relevant IS code (amended up to date) from HDPE pipe line up to consumer meter/premises by using electro fusion saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance withspecification for potable water including electrofusion saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or wheel valve and specials, below ground level 20 mm nominal dia MDPE pipe PE80 PN 16 as per ISO 4427 / 20 mm nominaldia PPR-C (Three layered) pipePN16 SDR 7.4 (IS:15801:2008) (ISI mark) for and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia GI pipes with fittings in the premises for fixing a tap / meterbox (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level.Note: Road cut and restoration is not part of this item and paid seperately. 236 For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr. 237 Road cutting for house hold service connection in minimum trench width whereever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be doneby using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge.. 238 Add extra over item no 1.21 & 1.22 for providing20 mm PE80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr.