Expression Of Interest Is Hereby Invited From The Manufacturer Or Their Authorized Stockiest/Distributors For Empanelment Of Vendor To Provide Artificial Appliances Implants - Stents For Cardiology Procedures On Credit Basis In Igmc , Technical Specifications Of Pacemakers, Other Devices And Consumables For Intervention (Cardiology Department). Separate Rates Should Be Quoted For Items Of Boq Sr. No. 2 To 197 For Bis/Dcgi Only. , Vvi * Pacemaker With Lead &Accessories. All Single Chamber Modes And Basic Multi-Programmable Parameters With Preferably Autosensing And Autocapture/Output Management Facilities. * Must Have Ventricular Capture Management. * Monitor The Integrity Of Lead And Switch Polarity In Case Of Issue. * The Size Of Lead Should Be 7F Or Less. * The Lead Must Be Steroid Eluting And Should Be Both Bipolar And Unipolar Configuration. * Must Have Both Active And Passive Fixation Endocardial Leads Available. * Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla. * Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. * Company Must Quote Only The Latest Model Of Devices Commercially Available. , Vvir • Pacemaker With Lead & Accessories. • All Single Chamber Modes And Basic Multi-Programmable Parameters With Preferably Autosensing And Autocapture /Output Management Facilities. • Must Have Ventricular Capture Management. • Monitor The Integrity Of Lead And Switch Polarity In Case Of Issue. The Size Of Lead Should Be 7F Or Less. • The Lead Must Be Steroid Eluting And Should Be Both Bipolar And Unipolar Configuration. • Must Have Both Active And Passive Fixation Endocardial Leads Available. • Must Have Rate Response Which Allows Rate Profile Optimization. • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla. • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. • Company Must Quote Only The Latest Model Of Devices Commercially Available. , Vvir (Paediatric) • Pacemaker With Lead & Accessories. • All Single Chamber Modes And With Paediatric Base Rate Upto 160Bpm And Parameters, Must Be Smallest Size Designated For Paediatrics Patient, Weight Should Be Less Than 14Gm, • Must Have Ventricular Capture Management. • The Size Of Lead Should Be 7F Or Less. • The Lead Must Be Steroid Eluting And Should Be Both Bipolar And Unipolar Configuration. • Must Have Both Active And Passive Fixation Endocardial Leads Available. • Must Have Rate Response Which Allows Rate Profile Optimization. • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla. • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. • Company Must Quote Only The Latest Model Of Devices Commercially Available. , Vvir (Mri Compatible) • Mri Conditional Pacemaker With Lead & Accessories • Should Allow Full Body At Least 1.5 T Mri Scan Preferably Without Any Restriction Zone. • Must Have Ventricular Capture Management • Monitor The Integrity Of Lead And Switch Polarity • The Size Of Lead Should Be 7F Or Less. • The Lead Must Be Steroid Eluting And Should Be Both Bipolar And Unipolar Configuration. • Must Have Both Active And Passive Fixation Endocardial Leads Available. • Must Have Rate Response Which Allows Rate Profile Optimization. • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. • Company Must Quote Only The Latest Model Of Devices Commercially Available. , Ddd • Pacemaker With Lead & Accessories • All Pacing Modes And Basic Pacing Programmable Parameters Including Hysteresis With Preferably Autosensing And Autocapture/Output Management Facilities. • Must Have Ventricular And Atrial Capture Management. • Must Minimize Ventricular Pacing By Optimizing Av Delay Automatically. • Monitor The Integrity Of Lead And Switch Polarity In Case Of Issue. • The Size Of Lead Should Be 7F Or Less. • The Lead Must Be Steroid Eluting And Should Be Both Bipolar And Unipolar Configuration. • Must Have Both Active And Passive Fixation Endocardial Leads Available. • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. • Company Must Quote Only The Latest Model Of Devices Commercially Available. , Dddr • Pacemaker With Lead & Accessories • All Pacing Modes And Basic Pacing Programmable Parameters Including Hysteresis With Preferably Autosensing And Autocapture/Output Management Facilities. • Must Have Ventricular And Atrial Capture Management. • Must Have Rate Response Which Allows Rate Profile Optimization. • Monitor The Integrity Of Lead And Switch Polarity In Case Of Issue. • The Size Of Lead Should Be 7F Or Less. • The Lead Must Be Steroid Eluting And Should Be Both Bipolar And Unipolar Configuration. • Must Have Both Active And Passive Fixation Endocardial Leads Available. • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. , Dddr Pacemaker (Mri Compatible) • Pacemaker With Lead & Accessories. • Should Allow Full Body At Least 1.5T Mri Scan Preferably Without Any Restriction Zone. • Mode Based Physiological Pacing Algorithm To Promote Intrinsic Conduction. • Patient Symptomatic Relief By Regularizing Ventricular Rhythm During Af. • Monitor The Integrity Of Lead And Switch Polarity In Case Of Issue. • The Size Of Lead Should Be 7F Or Less. • The Lead Must Be Steroid Eluting And Should Be Both Bipolar And Unipolar Configuration. • Must Have Both Active And Passive Fixation Endocardial Leads Available. • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. , Dddr ( With At/Af Management) • Pacemaker. • With All Lead & Accessories With Syncope Management & Af Prevention. • Should Allow Full Body At Least 1.5T Mri Scan Preferably Without Any Restriction Zone. • Evaluate Threshold Of Atrial & Ventricular Lead To Adjust Atrial & Ventricular Output On Daily Basis. • Automatically Adjust Sensitivity To Maintain Adequate Sensing Margins. • Dual Zone Rate Response, One For Normal Response And Other For Response During Exercise. • Mode Based Physiological Pacing Algorithm To Promote Intrinsic Conduction. • Atrial Intervention For Af Prevention By Constantly Overdriving Atrium. • Rate Drop Response For Syncope Management With Ability To Detect Both Drop Rate And Drop Size. • Atp Therapies To Terminate High-Rate Atrial Tachyarrhythmia Episodes. • The Size Of Lead Should Be 7F Or Less. • The Lead Must Be Steroid Eluting And Should Be Both Bipolar And Unipolar Configuration. • Must Have Both Active And Passive Fixation Endocardial Leads Available. • Must Have Rate Response Which Allows Rate Profile Optimization. • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required , Vdd/Vddr • With Lead & Accessories • All Vdd And Single Chamber Modes And Basic Pacing Programmable Parameters With Following Special Features. • Must Have Ventricular Capture Management. • Monitor The Integrity Of Lead And Switch Polarity In Case Of Issue • The Size Of Lead Should Be 9F Or Less. • The Lead Must Be Steroid Eluting And Should Be Both Bipolar And Unipolar Configuration. • Must Have Both Active And Passive Fixation Endocardial Leads Available. • Must Have Rate Response Which Allows Rate Profile Optimization. • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. • Company Must Quote Only The Latest Model Of Devices Commercially Available. , Implantable Loop Recorder • Mri Compatible With 1.5 &/Or 3.0 T System • Ability To Record At/Af Burden • Ability To Record Brady-/Tachy- Episodes • Patient Triggered Ecg Storage. , Aicd • Aicd Single Chamber With All Leads & Accessories. • Rv Lead Must Be 8F Or Less • All Basic Programmable Parameters With Preferably Autosensing And Auto Capture/Output Management Facilities. • Must Have Morphological Based Svt Discrimination • Must Monitor The Lead Integrity And Notify In Case Of A Suspected Failure • Must Have Shock Reduction Or Shock Guard Or Any Other Similar Technology. • Must Have Remote Patient Management Capability. • Lead Should Be Steroid Eluting. • Should Have Both Active And Passive Fixation Leads. • Standard International Warranty • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. • Company Must Quote Only The Latest Model Of Devices Commercially Available. , Aicd (Advanced) • Aicd Single Chamber With All Leads & Accessories • Defibrillator With Wireless Telemetry Without Requirement Of Additional Equipment • Should Be Able To Deliver At Least 35J Energy • Ability To Withhold Shock In Cases Of Rv Noise • Should Have Programmable Polarity Of Leads • Should Have Capture Management In Rv • Should Audibly Alert The Patient In Case Of Rv Noise & Lead Failure, And Extend Nidshould Monitor The Fluid Build-Up Status In A Heart Failure Patient And Audible Alert The Patient In Case Its Critical • Should Have Atp During Charge In Vf Mode, With An Option To Make It Atp Before Charge. • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. • Company Must Quote Only The Latest Model Of Devices Commercially Available. , Aicd • Mri Conditional Aicd Single Chamber With All Leads & Accessories • Defibrillator With Wireless Telemetry Without Requirement Of Additional Equipment • Should Be 1.5T &/Or 3T Full Body Mri Conditional Preferably Without Restriction Zone. • Should Have A Declared Longevity Of At Least 10 Years. • Should Be Able To Deliver At Least 35J Energy. • Should Have Capture Management In Rv. • Ability To Withhold Shock In Cases Of Rv Noise Or T-Wave Oversensing. • Capable Of Af Diagnosis Without Additional Lead. • Should Audibly Alert The Patient In Case Of Rv Noise & Lead Failure, And Extend Nid. • Should Monitor The Fluid Build-Up Status In A Heart Failure Patient, And Audible Alert The Patient In Case Its Critical • Should Have Atp During Charge In Vf Mode, With An Option To Make It Atp Before Charge. • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla. • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. • Company Must Quote Only The Latest Model Of Devices Commercially Available. , Aicd (Mri Compatible) • Defibrillator With Wireless Telemetry Without Requirement Of Additional Equipment • Us Fda Approved Dual Chamber Aicd With All Leads & Accessories • Defibrillator With Wireless Telemetry Without Requirement Of Additional Equipment • Should Be At Least 1.5T Full Body Mri Conditional Preferably Without Any Restriction Zone. • Should Have A Declared Longevity Of At Least 8 Years • Should Be Able To Minimize Rv Pacing • Should Be Able To Deliver At Least 35J Energy • Should Have Capture Management In Ra And Rv • Ability To Withhold Shock In Cases Of Rv Noise • Ability To Withhold Shock In Cases Of T-Wave Oversensing • Should Have Algorithms To Manage And Treat Atrial Arrhythmias • Should Have Rate Drop Response To Counter Neurocardiogenic Syncope • Should Audibly Alert The Patient In Case Of Rv Noise & Lead Failure. • Should Monitor The Fluid Build-Up Status In A Heart Failure Patient, And Audible Alert The Patient In Case Its Critical Level. , Crt-P • Biventricular Pacemaker With Atrial, Rv And Lv Leads And All Accessories • Must Have Separate Programmable Rv, Lv Lead Amplitude, Pulse Width And Vv Delay. • The Size Of Ra, Rv & Lv Leads Should Be 7F Or Less • The Leads Should Be Steroid Eluting And Should Be Bipolar And Unipolar Configuration • Should Have Both Active And Passive Fixation Ra & Rv Endocardial Leads. • Should Have Facility For Active Fixation Of Lv Lead In Cs With Both Screwing And/Or Deployable Lobes With Anchor Mechanism. • Should Have Facility For Epicardial Lv Lead Implantation. • Monitor The Integrity Of Lead And Switch Polarity In Case Of Issue • Must Have Ra, Rv And Lv Capture Management. • Must Have Remote Patient Management Capability. • Standard International Warranty. , Crt-P (Advanced) • Biventricular Pacemaker With Atrial, Rv And Lv Leads And All Accessories • Ability To Program Rv Synchronised Lv Only Pacing Mode • Should Have In-Clinic Optimization Capability • Should Have Ventricular Sense Response • Should Have Ventricular Safety Pacing In Order To Ensure 100% Crt Therapy • Should Have Capture Management In Ra, Rv And Lv • Should Monitor The Fluid Build-Up Status In A Heart Failure Patient, And Audible Alert The Patient In Case Its Critical. , Crt-D • Biventricular Pacemaker With Atrial, Rv And Lv Leads And All Accessories • Wireless Telemetry • Should Be Able To Deliver 35J Energy • Should Have Capture Management In Lv • Ability To Withhold Shock In Cases Of Rv Noise • Ability To Withhold Shock In Cases Of T-Wave Oversensing • Should Have Algorithms To Manage And Treat Atrial Arrhythmias • Should Have Rate Drop Response To Counter Neurocardiogenic Syncope • Should Audibly Alert The Patient In Case Of Rv Noise & Lead Failure. • Should Have Atp During Charge In Vf Mode, With An Option To Make It Atp Before Charge. , Crt-D (Advanced) • Biventricular Pacemaker With Atrial, Rv And Lv Leads And All Accessories • Wireless Telemetry • Should Have In-Clinic Optimization Capability • Compatible With Quadripolar Lead Options • Ability To Automatically Select The Best Pacing Vector • Should Be Able To Minimize Rv Pacing • Should Be Able To Deliver At Least 35J Energy • Should Have Capture Management In Ra, Rv And Lv • Ability To Withhold Shock In Cases Of Rv Noise • Ability To Withhold Shock In Cases Of T-Wave Oversensing • Should Have Algorithms To Manage And Treat Atrial Arrhythmias • Should Have Rate Drop Response To Counter Neurocardiogenic Syncope • Should Monitor The Fluid Build-Up Status In A Heart Failure Patient, And Audible Alert The Patient In Case Its Critical • Should Audibly Alert The Patient In Case Of Rv Noise & Lead Failure. • Should Have Atp During Charge In Vf Mode, With An Option To Make It Atp Before Charge. , Crt-D (Mri Compatible) • Biventricular Pacemaker With Atrial, Rv And Lv Leads And All Accessories. • Wireless Telemetry • Should Be 1.5T Or 3T Full Body Mri Conditional. • Should Have In-Clinic Optimization Capability • Compatible With Quadripolar Lead Options • Ability To Automatically Select The Best Pacing Vector. • Should Be Able To Minimize Rv Pacing • Should Be Able To Deliver At Least 35J Energy • Should Have Capture Management In Ra, Rv And Lv • Ability To Withhold Shock In Cases Of Rv Noise • Ability To Withhold Shock In Cases Of T-Wave Oversensing • Should Have Algorithms To Manage And Treat Atrial Arrhythmias • Should Have Rate Drop Response To Counter Neurocardiogenic Syncope • Should Audibly Alert The Patient In Case Of Rv Noise & Lead Failure. • Should Monitor The Fluid Build-Up Status In A Heart Failure Patient, And Audible Alert The Patient In Case Its Critical • Should Have Atp During Charge In Vf Mode, With An Option To Make It Atp Before Charge. , Crt-D (With Only Lv Pacing Option) • Biventricular Pacemaker With Atrial, Rv And Lv Leads And All Accessories • Wireless Telemetry • Ability To Program Rv Synchronized Lv Only Pacing Mode • Should Have In-Clinic Optimization Capability • Compatible With Quadripolar Lead Options • Ability To Automatically Select The Best Pacing Vector Through Vector Express • Should Be Able To Minimize Rv Pacing • Should Be Able To Deliver 35J Energy • Should Have Capture Management In Ra, Rv And Lv • Ability To Withhold Shock In Cases Of Rv Noise • Ability To Withhold Shock In Cases Of T-Wave Oversensing • Should Have Algorithms To Manage And Treat Atrial Arrhythmias • Should Have Rate Drop Response To Counter Neurocardiogenic Syncope • Should Audibly Alert The Patient In Case Of Rv Noise & Lead Failure. • Should Monitor The Fluid Build-Up Status In A Heart Failure Patient, And Audible Alert The Patient In Case Its Critical • Should Have Atp During Charge In Vf Mode, With An Option To Make It Atp Before Charge. , Crt-D (With Only Lv Pacing Option; Mri Compatible) • Biventricular Pacemaker With Atrial, Rv And Lv Leads And All Accessories. • Wireless Telemetry • Should Be 1.5T Or 3T Full Body Mri Conditional Without Exclusion Zone • Ability To Program Rv Syncronized Lv Only Pacing Mode • Should Have In-Clinic Optimization Capability • Compatible With Quadripolar Lead Options • Ability To Automatically Select The Best Pacing Vector Through Vector Express • Should Be Able To Minimize Rv Pacing • Should Be Able To Deliver 35J Energy • Should Have Capture Management In Ra, Rv And Lv • Ability To Withhold Shock In Cases Of Rv Noise • Ability To Withhold Shock In Cases Of T-Wave Oversensing • Should Have Algorithms To Manage And Treat Atrial Arrhythmias • Should Have Rate Drop Response To Counter Neurocardiogenic Syncope • Should Audibly Alert The Patient In Case Of Rv Noise & Lead Failure. • Should Monitor The Fluid Build-Up Status In A Heart Failure Patient, And Audible Alert The Patient In Case Its Critical • Should Have Atp During Charge In Vf Mode, With An Option To Make It Atp Before Charge. , Left Bundle/His Pacing * Left Bundle Pacing Lead/His Bundle Pacing Lead With Sheath And All The Accessories Used. * Deflectable Sheath Should Be Quoted Separately. , Fixed Tip Deflectable E.P. Catheters, All Curve. , Bidirectional 7F E.P. Catheter With Tip Electrode Of 4 And 5 Mm, All Curves. , Decapolar Coronary Sinus Catheter For Jugular/ Subclavian/Femoral Insertion, Fixed And Deflectable Tip, 5 F & 7F With Connector. , Parahisian Diagnostic Deflectable Catheter, Octapolar Configuration Catheter. , 20 Pole Deflectable Catheter For Atrial Isthmus Mapping. , Quadripolar Pacing Lead 6F/7F With Inter-Electrode Distance Of 5 Mm With Connectors. , Quadripolar Pacing Lead 6F/7F With Inter-Electrode Distance Of 5 Mm Withoutconnectors. , 4 And 5 Mm Tip Quadripolar Tip Deflectable Rf Ablation Catheter 7F, All Curves. , Thermocool Ablation Catheter. , Connecting Cables For Eps Catheter And Connectors. , Regular Thermistor/Thermocouple Rf Ablation Catheter. , Radio Frequency Ablation Catheter (4Mm) Compatible With Any Make Generator With Connector(7F), Different Curves, Push-Pull Technology. , Radio Frequency Ablation Catheter (8Mm) Compatible Any Make With Connector (7F), Different Curves, Push-Pull Technology. , Impedance Patches. , Balloon Catheter For Non-Contact Mapping Of Arrhythmias. , Radiofrequency Ablation Saline Cooled 4Mm Catheter Compatible With Any Make With Connector (7F). , Introducer Sheath With Haemostatic Valve And Locking Hub (8F/8.5F,12 Cm). , Introducer Sheath With 2 Port Haemostatic Valve And Locking Hub (10 &12F,12 Cm) , Introducer Sheath With 3 Port Haemostatic Valve And Locking Hub (12 &14F,12 Cm). , 7F 4Mm Bidirectional Steerable Ablation Catheter With Autolock Mechanism (All Curves) With Connector. , 7F 8Mm Bidirectional Steerable Ablation Catheter With Autolock Mechanism (All Curves) With Connector. , Connector For Radiofrequency Ablation Catheter Compatible With Ablator And Catheter Of Any Make Connector For Radiofrequency Ablation Catheter Compatible With Any Make. , Connector For Radiofrequency Ablation Catheter Compatible With Any Make. , Radiofrequency Ablation Catheter Unidirectional Def. Curve * 6/7Fr Size With 4Mm Tip Electrode. * 2-5-2 Mm Inter-Electrode Spacing. * 92-115Cm Insertion Length * Single Thermistor/Thermocouple Sensor With Connector , Radiofrequency Ablation Catheter Unidirectional Def. Curve * Polyurethane Coating With Bi-Directional Deflectable Curve, * 7Fr Size With 8Mm Tip Electrode And 1-6-2Mm Inter Electrode Spacing. * 115Cm Insertion Length, Single Long Thermocouple Sensor With Connector. , Irrigated Tip Ablation Catheter * Polyurethane Coating With Bi Directional Deflectable Curve. * 7Fr Size With 3.5Mm Tip Electrode * 6 Side-Holes For Open Loop Irrigation At The Tip Electrode, * 2-5-2 Mm Inter-Electrode, * Spacing.115Cm Insertion Length, Single Thermocouple Sensor With Connector. , Indifferent Patch Electrode (Reusable) With Connecting Cable. , Tubing For Irrigated Catheters Compatible With Cool Flow Pump. , Fixed Curve Quadripolar Electrophysiology Catheter (All Curve, 5-7F) With Connector. , Fixed Quadripolar Catheter Pre-Curve Shape For His Position. , Deflectable Quadripolar Electrophysiology Catheter (All Curve, 5-7F) With Connector. , Fixed Curve Deca-Polar Catheter For Coronary Sinus Mapping (All Curve, 5- 7F) With Connector. , Deflectable Deca -Polar Catheter For Coronary Sinus Mapping (All Curve, 5- 7F) With Connector. , Duo Deca-Polar Electrophysiology Catheter-20 Poles With Connector. , Bipolar Pacing Leads. 5F, 6F, &7F. , Balloon Tipped Pacing Leads 6F And & F. , List Of Consumables For Intervention (Cardiology Department) , Adult Femoral Introducer Sheath With Haemostatic Valve In A Kit Containing Puncture Needle And 0.038” Guide Wire. 4 To 7F. , Pediatric Femoral Introducer Sheath With Haemostatic Valve In A Kit Containing Puncture Needle , Adult And Pediatric Puncture Needle , Radial Introducer Sheath With Patent Unique Cross Cut Design Haemostatic Valve, 20Gx2 Puncture Needle With Plastic Iv Catheter And 0.025 Radifocus Mini Plastic Guidewire , Angiographic Guide Wire; Ptfe Coated; ‘J’ Tip & Straight Tip; Diameter 0.021”, 0.025,00.032, 0.035, 0.038 ; Length 120-150 (Regular Length). , Angiographic Guide Wire; Ptfe Coated; ‘J’ Tip & Straight Tip; Diameter 0.021”, 0.025,00.032, 0.035, 0.038 ; Length 250-260 Cm Exchange Length , Angiographic Guide Wire; Hydrophilic Coated; ‘J’ Tip & Straight Tip; Diameter 0.021”, 0.025,0,0.032, 0.035, 0.038 ; Length 120-150 (Regular Length , Angiographic Guide Wire; Hydrophilic Coated; ‘J’ Tip & Straight Tip; Diameter 0.021”, 0.025,0,0.032, 0.035, 0.038 ; Length 250-260 Cm (Exchange Length) , Three Way Stop Cock With One Male And Two Female Ports And Freely Rotating Adapter For Coronary Angiography. , Manifold - Two & Three Ports With Knobs To Turn “Right” When Open. , Radial Artery Compression Band Consists Of Two Balloons Specially Designed For Spot Compression Of The Radial Puncture Site , Short Connecting Pressure Line Of 20-30 Cm With Male Port In One Side And Female Port In The Other Side , High Pressure Injector Line To Withstand Pressure Up To 1200 Psi, 75-100 Cm Length With Luer Lock Male Port And Rotator. , Pressure Line: 120-150 Cm, 4-6 Mm, Compatible With Manifold And Three-Way Ports , Amplatzer Super Stiff Guide Wire, All Available Length And Diameters , Contrast Injecting Luer Lock Controlled Syringe 2, 5, 10 Cc With And Without Finger Grip , Short Tube Of 12 To 15 Inches To Connect To Touhyborst , Y-Connector Hemostatic Valve With Spring Type Push And Release Mechanism , Inflation Device With Manometer Up To 30 Atmosphere (Easy To Operate With Luminescent Dial) , Disposable Sterile Patient Drape With Pre-Shaped Circular Access For Both Radial And Femoral Approach During Cardiac Catheterization. , Disposal Sterile Cath Trolley Sheet. , Disposable Sterile Plastic Drape Sheet Used During Cardiac Catheterization , Sterile Adhesive Transparent Incision Drape; Absorbent And Completely Impervious To Fluids; Sizes 30-40 Cm X 25-40 Cm And 20-25 Cm X 10-15 Cm; Should Be Transparent With A Non-Glare Surface; Should Be Bacterial Proof And Water Proof , Disposable Gown Of Non-Woven Material With Elastic Wrist Bands, In All Sizes, With Fasteners , Disposable Sterile Linen/ Gauge Swabs Used During Cardiac Catheterization , Special Catheter For Cardiac Cath And Angio. All Sizes 4F To 7F: A. Swan Ganz Catheter B. Berman Cath C. Nih D. Counard Catheter E. Head Hunter Catheter F. Simmons Catheter G. Pig Tail Catheter Straight H. Pigtail Catheter With Markers I. Angled Pig Tail Catheter J. Vtk Catheter , Coronary Angiography Diagnostic Catheters 100 Cm Or Longer For Femoral Approach And Various Curves (Wherever Applicable) Of 3.0, 3.5, 4.0, 4.5, 5.0 A. Judkins Left 5F/6F B. Judkins Right 5F/6F C. Amplatz Left (Ali/Alii/Aliii) 5F/6F D. Amplatz Right (Ari/Arii) 5F/6F E. I.M.A. Catheter 5F/6F F. Right Coronary Catheter Not Requiring Torque (Ntr) 5F/6F G. Multipurpose Ai, Ii 5F/6F H. Multipurpose Bi, Ii 5F/6F I. 3Drc (Williams Catheter, 5.2 , Radial Diagnostic Catheter With The Unique Tiger Curve Which Enables Angiography Of Right And Left Coronary Arteries Using Either Radial Or Brachial Approach , Ptca Guiding Catheter, 100 Cm Long. It Should Be Large Lumen Braided, Inner Layer Coated With Ptfe. It Should Have Atraumatic Soft Tip With Radio Opaque Marker Band At The Tip. A. Judkins Left With/ Without Side Holes (Curves 3, 3.5, 4, 5Cm) Size5f/6F/7F/8F B. Judkins Left With Short Tip (Curves 3, 3.5, 4, 5 Cm), Size5f/6F/7F/8F. C. Judkins Rightwith/Without Side Holes (Cvs 3, 3.5, 4, 5Cm) Size5f/6F/7F/8F D. Judkins Right With Short Tip (Curves 3, 3.5, 4, 5 Cm), Size 5F/6F/7F/8F E. Ima Guiding Catheter, 5F/6F/7F F. Multipurpose (Ai, Aii), 5F/6F/7F/8F G. Multipurpose (Bi, Bii), 5F/6F/7F/8F H. Amplatzleft With/ Without Side Holes (Curves Al0.75, Al1, Al1.5, Al2, Al3),5F/6F/7F/8F I. Amplatz Right With/Without Side Holes (Curves Al0.75, Al1, Al1.5, Al2, Al3), 5F/F/7F/8F J. Voda Left, 5F/6F/7F/8F K. Voda Right, 5F/6F/7F/8F L. Left Coronary Bypass Guide Catheter, 6F/7F M. Right Coronary Bypass Guide Catheter, 6F/7F N. Contra Lateral Support (Cls) Left Without Side Holes, 5F/6F/7F/8F O. Contra Lateral Support (Cls) Left With Side Hole, 5F/6F/7F/8F P. Contra Lateral Support (Cls) Right Without Side Hole, 5F/6F/7F/8F Q. Contra Lateral Support (Cls) Right With Side Hole, 5F/6F/7F/8F R. 3D Right Guiding Catheter Without Side Hole, 6F/7F S. 3D Right Guiding Catheter With Side Hole, 6F/7F T. Hockey Stick Guiding Catheter, 6F/7F U. Shepherd Crook Right Type Guiding (Curves 3.5, 4, 5), 6F/7F V. Head Hunter Guiding Catheter, 6F/7F W. Ikari Guide 6F,&F , Ptca Guide Wire With Ptfe Coating Over Shaft, Polymer Sleeve Length Of 20Cm, Tip Load Of 0.8 Gm, Tip Size Of 0.014”, Tip Radiopacity Of 3Cm * 180-190 Cm Long , Ptca Guide Wire With Ptfe Coating Over Shaft, Polymer Sleeve Length Of 20Cm, Tip Load Of 0.8 Gm, Tip Size Of 0.014”, Tip Radiopacity Of 3Cm * 280-300 Cm Long , Ptca Guide Wire With Ptfe Coating Over Shaft, Polymer Sleeve Length Of 20 Cm, Tip Load Of 0.8 Gm, Tip Size Of 0.009”, Tip Radiopacity Of 16 Cm * 180-190 Cm Long , Ptca Guide Wire With Ptfe Coating Over Shaft, Polymer Sleeve Length Of 20 Cm, Tip Load Of 0.8 Gm, Tip Size Of 0.009”, Tip Radiopacity Of 16 Cm * 280-300 Cm Long , Ptca Extra-Support Guide Wire With Ptfe Coating Over Shaft, Tip Load Of 0.7 Gm, Tip Size Of 0.014”, Spring Coil Of 4 Cm And Tip Radiopacity Of 4 Cm *180-190 Cm Long , Ptca Extra-Support Guide Wire With Ptfe Coating Over Shaft, Tip Load Of 0.7 Gm, Tip Size Of 0.014”, Spring Coil Of 4 Cm And Tip Radiopacity Of 4 Cm *280-300 Cm Long , Ptca Guide Wire For Cto With Ptfe Coating Over Shaft, Tip Size Of 0.014”, Tip Radiopacity Of 11 Cm And Spring Coil Of 11 Cm, Length Of 180-190 Cm Tip Load Of * 3Gm , Ptca Guide Wire For Cto With Ptfe Coating Over Shaft, Tip Size Of 0.014”, Tip Radiopacity Of 11 Cm And Spring Coil Of 11 Cm, Length Of 180-190 Cm Tip Load Of *4.5Gm , Ptca Guide Wire For Cto With Ptfe Coating Over Shaft, Tip Size Of 0.014”, Tip Radiopacity Of 11 Cm And Spring Coil Of 11 Cm, Length Of 180-190 Cm Tip Load Of *6Gm , Ptca Guide Wire For Cto With Ptfe Coating Over Shaft, Tip Size Of 0.014”, Tip Radiopacity Of 11 Cm And Spring Coil Of 11 Cm, Length Of 180-190 Cm Tip Load Of *12Gm , Ptca Guide Wire For Cto With Extra-Support, Tip Load Of 9 Gm, Tip Size Of 0.009”, Length 180-190 Cm, With *Spring Coil And Tip Radiopacity Of 11 Cm , Ptca Guide Wire For Cto With Extra-Support, Tip Load Of 9 Gm, Tip Size Of 0.009”, Length 180-190 Cm, With * Spring Coil And Tip Radiopacity Of 20 Cm , Joint Less Spring Coil 0.014” One Piece Core Ptca Guide Wire With Tip Radiopacity 3 Cm, Length 180 Cm * Tip Load 0.7 Gm , Joint Less Spring Coil 0.014” One Piece Core Ptca Guide Wire With Tip Radiopacity 3 Cm, Length 180 Cm * Tip Load 0.5 Gm , Ptca Guide Wires, 0.014”, 180-190 Cm Long, Nitinol Distal Super Elastic Core For Kink Resistance And Shape Retention, Silicon Coating For Distal 2 Cm And Hydrophilic Coating Of Rest Of The Wire Length * Tip Load Of 1.0 Gm , Ptca Guide Wires, 0.014”, 180-190 Cm Long, Nitinol Distal Super Elastic Core For Kink Resistance And Shape Retention, Silicon Coating For Distal 2 Cm And Hydrophilic Coating Of Rest Of The Wire Length * Tip Load Of 0.6 Gm , Ptca Guide Wires, 0.014”, 180-190 Cm Long, Nitinol Distal Super Elastic Core For Kink Resistance And Shape Retention, Silicon Coating For Distal 2 Cm And Hydrophilic Coating Of Rest Of The Wire Length * Tip Load Of 3.6 Gm , Steerable Ptca Guide Wire With Floppy Tip, Elastinite Core, Soft Shaping Ribbon Tip And Hydrophilic Or Hydrophobic Coating * 180-190 Cm. , Steerable Ptca Guide Wire With Floppy Tip, Elastinite Core, Soft Shaping Ribbon Tip And Hydrophilic Or Hydrophobic Coating. * 280-300 Cm. , Steerable Ptca Extra Support Guide Wire With Durasteel Core Material, Core To Tip Design, Floppy Tip *With Hydrophobic Coating , Steerable Ptca Extra Support Guide Wire With Durasteel Core Material, Core To Tip Design, Floppy Tip *With Hydrophilic Coating , Steerable Pta High Support Guide Wire Of 0.018”, Body Ptfe/Hydrophobic Coated, Distal Hydrophilic Coating, Distal Radiopacity Of 2 Cm * 180-190 Cm Long , Steerable Pta High Support Guide Wire Of 0.018”, Body Ptfe/Hydrophobic Coated, Distal Hydrophilic Coating, Distal Radiopacity Of 2 Cm * =300 Cm Long , Ptra Guide Wire For Renal Angioplasty, Diameter 0.018”, 100- 110 Cm Long , Steerable Pta Guide Wire With Floppy Tip, Titanium Stainless Steel Alloy Core, Extra-Support Of 0.018” Diameter, =300 Cm Long. A. Tip Non-Hydrophilic B. Tip Hydrophilic , Ptca Pre-Dilatation, Monorail Balloon (Semi Compliant). Hypotube Shaft Design, Low Entry Profile (=0.017”) And 5F Guide Catheter Compatibility. Diameters (Mm): 1.2/1.25, 1.5, 2.0, 2.5, 3, 3.5, 4.0. Length: Minimum 6-8 Mm To Maximum 20 Mm Or More , Ptca Pre-Dilatation Semi-Compliant Balloon, With Push And Flex Technology, Lowest Tip Entry Profile Of =0.017”, Crossing Profile Of =0.021”, Low Profile And Marker For Better Visibility, Stepwise Transition Stiffening For More Pushability. Diameter (Mm): 1.2/1.25, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0. Length: Minimum 6-8 Mm To Maximum 20 Mm Or More , High Pressure Non-Compliant Balloon Smooth, Rounded Distal Tip And No Edge Over-Dilatation At Higher Pressure; With Least Balloon Overhang At The Edges. Diameter (Mm): 2.5, 2.75, 3.0, 3.25, 3.5, 3.75, 4, Length (Mm): Minimum 6-8Mm To =20 Mm , Ultra-Low Entry Profile Semi Compliant Balloon With .40Mm Or 0.016” And Entry Profile From 1.25*10 To 2.25*10 Remains Same For Exceptional Cross Ability Even With Higher Diameter Balloon A. Otw Over 0.018” Guidewire. B.Monorail Over 0.018” Guidewire , Peripheral Long Balloon, Hydrophobic Coating, 4F Sheath Compatible, Various Diameters Of 2-4 Mm. Length: 20 To =200 Mm, Otw Over 0.014” Guidewire. , Coronary Microcatheter With Distal Diameter Of 1.8 Fr Or Less, Proximal Diameter 2.6F, Ptfe Coated Inner Layer, And Distal Hydrophilic Coating At The Outer Layer, Flexible Tip With Outer And Inner Taper With Gold Marker At Distal Tip For Enhanced Distal Visibility To Cross Difficult Lesions * 130-135 Cm Long , Coronary Microcatheter With Distal Diameter Of 1.8 Fr Or Less, Proximal Diameter 2.6F, Ptfe Coated Inner Layer, And Distal Hydrophilic Coating At The Outer Layer, Flexible Tip With Outer And Inner Taper With Gold Marker At Distal Tip For Enhanced Distal Visibility To Cross Difficult Lesions * 150-160 Cm Long , Drug Eluting Coronary Balloon. (All Diameters And Sizes Available) A. Paclitaxel Eluting Balloon B. Sirolimus Eluting Balloon , Ivc Filter A. Temporary B. Permanent (Mri & Non Mri Compatible) , Rota Burr For Rotational Coronary Atherectomy, 1.25- 2.0 Mm. A. Burr Only. B. Burr With Advancer. C. Advancer Only , Guide Wire For Rotational Coronary Atherectomy A. Floppy. B. Extra Support , Guideliner Catheter, 6F/7F, Rapid Exchange With 145-150 Cm Working Length, Tip Radiopaque Marker , Guide Extension Catheter Other Make, 145-150 Cms Working Length , Coronary Micro-Catheter , Coronary Mother And Child Catheter , Coronary Covered Stents All Sizes , Balloon Mounted Monorail 0.014 Compatible Stainless Steel Renal Stent, All Types And Sizes , Balloon Mounted Monorail 0.014 Compatible Cobalt Chromium Renalstent, All Types And Sizes , Peripheral Stainless Steel Stent Otw/Monorail ,Balloon Mounted, All Types And Sizes , Peripheral Stainless Steel Stent, Otw/Monorail Self Expanding, All Types And Sizes , Peripheral Cobalt Chromium Stents, Otw/Monorail Self Expanding All Types And Sizes , Peripheral Cobalt Chromium Stent, Otw/Monorail, Balloon Mounted, All Types And Sizes , Peripheral Covered Stents , Nitinol Peripheral Stent, Otw/Monorail, All Types And Sizes , Peripheral Drug Eluting Balloon , Ptmc Accessories Set Complete , Spring Wire For Ptmc. , Stylet For Ptmc Balloon. , Septal Dilator For Ptmc. , Mitral Balloon All Sizes. , Mitral Balloon All Sizes. , Brokenbrough Needle Adult And Pediatric. , Mullin Sheaths Adult All Sizes. , Mullins Sheath, Paediatrics All Sizes. , Shuttle Sheaths All Sizes. , Carotid Stents All Sizes Self-Expanding/Balloon Expandable. , Filterwie For Carotid Angioplasty. , Cross Over Sheaths All Sizes. , Pulmonary Valvuloplasty Catheters. (Pediatric) , Pulmonary Valvuloplasty Catheters (Adults).All Sizes. , Aortic Valvuloplasty Catheters (Pediatric). , Aortic Valvuloplasty Catheters (Adults). , Balloons For Valvuloplasty,( Adult&Pediatric) All Sizes. , Endomyocardial Biopsy Catheters, All Sizes. , Intravasacular Retrieval Snares. , Snares With 3 Loops. , Artery Retrieval Snares. , Micro Vena Snares. , Destination Sheath For Carotids. All Sizes. , Pda Coils All Sizes. , Pda Closure Devices All Types And Sizes. (Quote Separately) , Asd Closure Devices All Types And Sizes. (Quote Separately) , Vsd Closure Devices All Types And Sizes. (Quote Separately) , Delivery System For Asd, Complete Set. , Delivery System For Vsd, Complete Set. , Delivery System For Pda, Complete Set. , Vasacular Plugs All Types And Sizes. , Cp Stent All Sizes. , Bib Stent For Coarctation. , Covered Stent For Coarctation. , Pva Particles All Sizes. , Micro Coils For Avm. , Cyanoacrylate Glue. , Microcatheter For Uterine Artery Embolization. , Ffr Wire Which Should Be Hydrophilic And With A Tip Load 0.6G. Should Be Usfda Approved. , Oct Catheter For Advanced, High Resolution Imaging. Its Tip Should Be Low Profile (2.7F), And Catheter Should Be Compatible With Standard 0.014 Guide Wires , Ivus Catheter With Single Rotating/Mechanical Transducer Driven By A Flexible Drive Cable With Minimum 20 Mhz Frequency. , Embolectomy Catheter 2 × 2 For Bas. , Non Ionic Iodine Contrast Iohexol 300 Mg X50 Ml Pack , Non Ionic Iodine Contrast Iohexol 300 Mg X100 Ml Pack , Non Ionic Iodine Contrast Iohexol 350 Mg X50 Ml Pack , Non Ionic Iodine Contrast Iohexol 350 Mg X100 Ml Pack , Iodixanol 320 Mg Iodine Per Ml. X 50 Ml Pack , Iodixanol 320 Mg Iodine Per Ml. X100 Ml Pack , Iomeperol 400Mg Iodine Per Ml. X 100 Ml Pack , Iobitridol 370Mg Iodine Per Ml X 100 Ml , Iopromide 300Mg Iodine Per Ml. 50 Ml Pack , Iopromide370 Mg Iodine Per Ml. 50 Ml Pack , Iopromide 300Mg Iodine Per Ml. 100 Ml Pack , Iopromide 370Mg Iodine Per Ml. 100 Ml Pack , Renal Denervation Therapy - Spiral Multi Electrode Renal Denervation Catheter Essential Features: A. The Catheter Should Be Able To Provide Plug And Play Design With A Uniform Sizing That Fits The Anatomy Of The Renal Artery, Accessory And Brand Vessels In The Diameter Of 3-8Mm. B. It Should Be Having A Multi-Electrode System That Covers The 4 Quadrants Simultaneously For A Circumferential Ablation Giving Complete Denervation As The Result. C. Rapid Exchange Design Compatible With 0.014” Guidewire. D. Guidewire Retraction Used To Deploy The Spiral Electrode Array. E. Rx Joint: 30Cm From Distal Tip. F. Vessel Diameter Treatment Range 3-8Mm. G. Four Independently Controlled Rf Monopolar Gold Electrodes Spaced 6.5Mm Apart (Distal Self-Expanding Array Of 4 Electrodes, Which Is Made Of Gold, Radio-Opaque And 1.5Mm In Length). H. Treatment Length 17-21Mm If All Electrodes Are Activated. I.Tip Length 5Mm J. Tip Marker: 1Mm Proximal Of Distal Tip (Platinum/ Iridium Alloy As Tip Marker) K. Femoral Shaft Marker 55Cm From Distal Tip L. Sterilization Process: E-Beam And 10-6Sal M. Shelf Life: Three Years. , Endovascular Repair Of Thoracic And Abdominal Aortic Aneurysm(Evar/Tevar) Stent Graft Of All Size: 18-32Mm Diameter) Infra Renal Neck Length (Minimum – 15Mm) Material – Ptfe/Polyester Trifurcated Or Aorto – Unilliac Configuration , Trans Catheter Aortic Valve Replacement (Tavr) - Self Expanding Valve (Sev) - Balloon Expendable Valve (Bev) Specification Of Evolut Fx Self-Expanding, Recapturable Supra-Annular Porcine Pericardium Aortic Tavr Valve With An External Skirt And 3Mm Depth Markers, Delivered Through A Single-Spine Catheter, Designed To Treat Annulus Ranging From 17 To 30Mm. Evolut Fx 23-34 Evolut Pro Plus Self-Expanding, Recapturable Supra-Annular Porcine Pericardium Aortic Tavr Valve With An External Skirt Designed To Treat Annulus Ranging From 17 To 30Mm. Evolut Pro+ 23-34 , Technical Specifications Of Pacemakers, Other Devices And Consumables For Intervention (Cardiology Department). Separate Rates Should Be Quoted For Items Of Boq Sr. No.199 To 394 For European Ce Marked . , Vvi * Pacemaker With Lead &Accessories. All Single Chamber Modes And Basic Multi-Programmable Parameters With Preferably Autosensing And Autocapture/Output Management Facilities. * Must Have Ventricular Capture Management. * Monitor The Integrity Of Lead And Switch Polarity In Case Of Issue. * The Size Of Lead Should Be 7F Or Less. * The Lead Must Be Steroid Eluting And Should Be Both Bipolar And Unipolar Configuration. * Must Have Both Active And Passive Fixation Endocardial Leads Available. * Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla. * Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. * Company Must Quote Only The Latest Model Of Devices Commercially Available. , Vvir • Pacemaker With Lead & Accessories. • All Single Chamber Modes And Basic Multi-Programmable Parameters With Preferably Autosensing And Autocapture /Output Management Facilities. • Must Have Ventricular Capture Management. • Monitor The Integrity Of Lead And Switch Polarity In Case Of Issue. The Size Of Lead Should Be 7F Or Less. • The Lead Must Be Steroid Eluting And Should Be Both Bipolar And Unipolar Configuration. • Must Have Both Active And Passive Fixation Endocardial Leads Available. • Must Have Rate Response Which Allows Rate Profile Optimization. • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla. • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. • Company Must Quote Only The Latest Model Of Devices Commercially Available. , Vvir (Paediatric) • Pacemaker With Lead & Accessories. • All Single Chamber Modes And With Paediatric Base Rate Upto 160Bpm And Parameters, Must Be Smallest Size Designated For Paediatrics Patient, Weight Should Be Less Than 14Gm, • Must Have Ventricular Capture Management. • The Size Of Lead Should Be 7F Or Less. • The Lead Must Be Steroid Eluting And Should Be Both Bipolar And Unipolar Configuration. • Must Have Both Active And Passive Fixation Endocardial Leads Available. • Must Have Rate Response Which Allows Rate Profile Optimization. • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla. • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. • Company Must Quote Only The Latest Model Of Devices Commercially Available. , Vvir (Mri Compatible) • Mri Conditional Pacemaker With Lead & Accessories • Should Allow Full Body At Least 1.5 T Mri Scan Preferably Without Any Restriction Zone. • Must Have Ventricular Capture Management • Monitor The Integrity Of Lead And Switch Polarity • The Size Of Lead Should Be 7F Or Less. • The Lead Must Be Steroid Eluting And Should Be Both Bipolar And Unipolar Configuration. • Must Have Both Active And Passive Fixation Endocardial Leads Available. • Must Have Rate Response Which Allows Rate Profile Optimization. • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. • Company Must Quote Only The Latest Model Of Devices Commercially Available. , Ddd • Pacemaker With Lead & Accessories • All Pacing Modes And Basic Pacing Programmable Parameters Including Hysteresis With Preferably Autosensing And Autocapture/Output Management Facilities. • Must Have Ventricular And Atrial Capture Management. • Must Minimize Ventricular Pacing By Optimizing Av Delay Automatically. • Monitor The Integrity Of Lead And Switch Polarity In Case Of Issue. • The Size Of Lead Should Be 7F Or Less. • The Lead Must Be Steroid Eluting And Should Be Both Bipolar And Unipolar Configuration. • Must Have Both Active And Passive Fixation Endocardial Leads Available. • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. • Company Must Quote Only The Latest Model Of Devices Commercially Available. , Dddr • Pacemaker With Lead & Accessories • All Pacing Modes And Basic Pacing Programmable Parameters Including Hysteresis With Preferably Autosensing And Autocapture/Output Management Facilities. • Must Have Ventricular And Atrial Capture Management. • Must Have Rate Response Which Allows Rate Profile Optimization. • Monitor The Integrity Of Lead And Switch Polarity In Case Of Issue. • The Size Of Lead Should Be 7F Or Less. • The Lead Must Be Steroid Eluting And Should Be Both Bipolar And Unipolar Configuration. • Must Have Both Active And Passive Fixation Endocardial Leads Available. • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. , Dddr Pacemaker (Mri Compatible) • Pacemaker With Lead & Accessories. • Should Allow Full Body At Least 1.5T Mri Scan Preferably Without Any Restriction Zone. • Mode Based Physiological Pacing Algorithm To Promote Intrinsic Conduction. • Patient Symptomatic Relief By Regularizing Ventricular Rhythm During Af. • Monitor The Integrity Of Lead And Switch Polarity In Case Of Issue. • The Size Of Lead Should Be 7F Or Less. • The Lead Must Be Steroid Eluting And Should Be Both Bipolar And Unipolar Configuration. • Must Have Both Active And Passive Fixation Endocardial Leads Available. • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. , Dddr ( With At/Af Management) • Pacemaker. • With All Lead & Accessories With Syncope Management & Af Prevention. • Should Allow Full Body At Least 1.5T Mri Scan Preferably Without Any Restriction Zone. • Evaluate Threshold Of Atrial & Ventricular Lead To Adjust Atrial & Ventricular Output On Daily Basis. • Automatically Adjust Sensitivity To Maintain Adequate Sensing Margins. • Dual Zone Rate Response, One For Normal Response And Other For Response During Exercise. • Mode Based Physiological Pacing Algorithm To Promote Intrinsic Conduction. • Atrial Intervention For Af Prevention By Constantly Overdriving Atrium. • Rate Drop Response For Syncope Management With Ability To Detect Both Drop Rate And Drop Size. • Atp Therapies To Terminate High-Rate Atrial Tachyarrhythmia Episodes. • The Size Of Lead Should Be 7F Or Less. • The Lead Must Be Steroid Eluting And Should Be Both Bipolar And Unipolar Configuration. • Must Have Both Active And Passive Fixation Endocardial Leads Available. • Must Have Rate Response Which Allows Rate Profile Optimization. • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required , Vdd/Vddr • With Lead & Accessories • All Vdd And Single Chamber Modes And Basic Pacing Programmable Parameters With Following Special Features. • Must Have Ventricular Capture Management. • Monitor The Integrity Of Lead And Switch Polarity In Case Of Issue • The Size Of Lead Should Be 9F Or Less. • The Lead Must Be Steroid Eluting And Should Be Both Bipolar And Unipolar Configuration. • Must Have Both Active And Passive Fixation Endocardial Leads Available. • Must Have Rate Response Which Allows Rate Profile Optimization. • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. • Company Must Quote Only The Latest Model Of Devices Commercially Available. , Implantable Loop Recorder • Mri Compatible With 1.5 &/Or 3.0 T System • Ability To Record At/Af Burden • Ability To Record Brady-/Tachy- Episodes • Patient Triggered Ecg Storage. , Aicd • Aicd Single Chamber With All Leads & Accessories. • Rv Lead Must Be 8F Or Less • All Basic Programmable Parameters With Preferably Autosensing And Auto Capture/Output Management Facilities. • Must Have Morphological Based Svt Discrimination • Must Monitor The Lead Integrity And Notify In Case Of A Suspected Failure • Must Have Shock Reduction Or Shock Guard Or Any Other Similar Technology. • Must Have Remote Patient Management Capability. • Lead Should Be Steroid Eluting. • Should Have Both Active And Passive Fixation Leads. • Standard International Warranty • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. • Company Must Quote Only The Latest Model Of Devices Commercially Available. , Aicd (Advanced) • Aicd Single Chamber With All Leads & Accessories • Defibrillator With Wireless Telemetry Without Requirement Of Additional Equipment • Should Be Able To Deliver At Least 35J Energy • Ability To Withhold Shock In Cases Of Rv Noise • Should Have Programmable Polarity Of Leads • Should Have Capture Management In Rv • Should Audibly Alert The Patient In Case Of Rv Noise & Lead Failure, And Extend Nidshould Monitor The Fluid Build-Up Status In A Heart Failure Patient And Audible Alert The Patient In Case Its Critical • Should Have Atp During Charge In Vf Mode, With An Option To Make It Atp Before Charge. • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. • Company Must Quote Only The Latest Model Of Devices Commercially Available. , Aicd • Mri Conditional Aicd Single Chamber With All Leads & Accessories • Defibrillator With Wireless Telemetry Without Requirement Of Additional Equipment • Should Be 1.5T &/Or 3T Full Body Mri Conditional Preferably Without Restriction Zone. • Should Have A Declared Longevity Of At Least 10 Years. • Should Be Able To Deliver At Least 35J Energy. • Should Have Capture Management In Rv. • Ability To Withhold Shock In Cases Of Rv Noise Or T-Wave Oversensing. • Capable Of Af Diagnosis Without Additional Lead. • Should Audibly Alert The Patient In Case Of Rv Noise & Lead Failure, And Extend Nid. • Should Monitor The Fluid Build-Up Status In A Heart Failure Patient, And Audible Alert The Patient In Case Its Critical • Should Have Atp During Charge In Vf Mode, With An Option To Make It Atp Before Charge. • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla. • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. • Company Must Quote Only The Latest Model Of Devices Commercially Available. , Aicd (Mri Compatible) • Defibrillator With Wireless Telemetry Without Requirement Of Additional Equipment • Us Fda Approved Dual Chamber Aicd With All Leads & Accessories • Defibrillator With Wireless Telemetry Without Requirement Of Additional Equipment • Should Be At Least 1.5T Full Body Mri Conditional Preferably Without Any Restriction Zone. • Should Have A Declared Longevity Of At Least 8 Years • Should Be Able To Minimize Rv Pacing • Should Be Able To Deliver At Least 35J Energy • Should Have Capture Management In Ra And Rv • Ability To Withhold Shock In Cases Of Rv Noise • Ability To Withhold Shock In Cases Of T-Wave Oversensing • Should Have Algorithms To Manage And Treat Atrial Arrhythmias • Should Have Rate Drop Response To Counter Neurocardiogenic Syncope • Should Audibly Alert The Patient In Case Of Rv Noise & Lead Failure. • Should Monitor The Fluid Build-Up Status In A Heart Failure Patient, And Audible Alert The Patient In Case Its Critical Level. , Crt-P • Biventricular Pacemaker With Atrial, Rv And Lv Leads And All Accessories • Must Have Separate Programmable Rv, Lv Lead Amplitude, Pulse Width And Vv Delay. • The Size Of Ra, Rv & Lv Leads Should Be 7F Or Less • The Leads Should Be Steroid Eluting And Should Be Bipolar And Unipolar Configuration • Should Have Both Active And Passive Fixation Ra & Rv Endocardial Leads. • Should Have Facility For Active Fixation Of Lv Lead In Cs With Both Screwing And/Or Deployable Lobes With Anchor Mechanism. • Should Have Facility For Epicardial Lv Lead Implantation. • Monitor The Integrity Of Lead And Switch Polarity In Case Of Issue • Must Have Ra, Rv And Lv Capture Management. • Must Have Remote Patient Management Capability. • Standard International Warranty. , Crt-P (Advanced) • Biventricular Pacemaker With Atrial, Rv And Lv Leads And All Accessories • Ability To Program Rv Synchronised Lv Only Pacing Mode • Should Have In-Clinic Optimization Capability • Should Have Ventricular Sense Response • Should Have Ventricular Safety Pacing In Order To Ensure 100% Crt Therapy • Should Have Capture Management In Ra, Rv And Lv • Should Monitor The Fluid Build-Up Status In A Heart Failure Patient, And Audible Alert The Patient In Case Its Critical. , Crt-D • Biventricular Pacemaker With Atrial, Rv And Lv Leads And All Accessories • Wireless Telemetry • Should Be Able To Deliver 35J Energy • Should Have Capture Management In Lv • Ability To Withhold Shock In Cases Of Rv Noise • Ability To Withhold Shock In Cases Of T-Wave Oversensing • Should Have Algorithms To Manage And Treat Atrial Arrhythmias • Should Have Rate Drop Response To Counter Neurocardiogenic Syncope • Should Audibly Alert The Patient In Case Of Rv Noise & Lead Failure. • Should Have Atp During Charge In Vf Mode, With An Option To Make It Atp Before Charge. , Crt-D (Advanced) • Biventricular Pacemaker With Atrial, Rv And Lv Leads And All Accessories • Wireless Telemetry • Should Have In-Clinic Optimization Capability • Compatible With Quadripolar Lead Options • Ability To Automatically Select The Best Pacing Vector • Should Be Able To Minimize Rv Pacing • Should Be Able To Deliver At Least 35J Energy • Should Have Capture Management In Ra, Rv And Lv • Ability To Withhold Shock In Cases Of Rv Noise • Ability To Withhold Shock In Cases Of T-Wave Oversensing • Should Have Algorithms To Manage And Treat Atrial Arrhythmias • Should Have Rate Drop Response To Counter Neurocardiogenic Syncope • Should Monitor The Fluid Build-Up Status In A Heart Failure Patient, And Audible Alert The Patient In Case Its Critical • Should Audibly Alert The Patient In Case Of Rv Noise & Lead Failure. • Should Have Atp During Charge In Vf Mode, With An Option To Make It Atp Before Charge. , Crt-D (Mri Compatible) • Biventricular Pacemaker With Atrial, Rv And Lv Leads And All Accessories. • Wireless Telemetry • Should Be 1.5T Or 3T Full Body Mri Conditional. • Should Have In-Clinic Optimization Capability • Compatible With Quadripolar Lead Options • Ability To Automatically Select The Best Pacing Vector. • Should Be Able To Minimize Rv Pacing • Should Be Able To Deliver At Least 35J Energy • Should Have Capture Management In Ra, Rv And Lv • Ability To Withhold Shock In Cases Of Rv Noise • Ability To Withhold Shock In Cases Of T-Wave Oversensing • Should Have Algorithms To Manage And Treat Atrial Arrhythmias • Should Have Rate Drop Response To Counter Neurocardiogenic Syncope • Should Audibly Alert The Patient In Case Of Rv Noise & Lead Failure. • Should Monitor The Fluid Build-Up Status In A Heart Failure Patient, And Audible Alert The Patient In Case Its Critical • Should Have Atp During Charge In Vf Mode, With An Option To Make It Atp Before Charge. , Crt-D (With Only Lv Pacing Option) • Biventricular Pacemaker With Atrial, Rv And Lv Leads And All Accessories • Wireless Telemetry • Ability To Program Rv Synchronized Lv Only Pacing Mode • Should Have In-Clinic Optimization Capability • Compatible With Quadripolar Lead Options • Ability To Automatically Select The Best Pacing Vector Through Vector Express • Should Be Able To Minimize Rv Pacing • Should Be Able To Deliver 35J Energy • Should Have Capture Management In Ra, Rv And Lv • Ability To Withhold Shock In Cases Of Rv Noise • Ability To Withhold Shock In Cases Of T-Wave Oversensing • Should Have Algorithms To Manage And Treat Atrial Arrhythmias • Should Have Rate Drop Response To Counter Neurocardiogenic Syncope • Should Audibly Alert The Patient In Case Of Rv Noise & Lead Failure. • Should Monitor The Fluid Build-Up Status In A Heart Failure Patient, And Audible Alert The Patient In Case Its Critical • Should Have Atp During Charge In Vf Mode, With An Option To Make It Atp Before Charge. , Crt-D (With Only Lv Pacing Option; Mri Compatible) • Biventricular Pacemaker With Atrial, Rv And Lv Leads And All Accessories. • Wireless Telemetry • Should Be 1.5T Or 3T Full Body Mri Conditional Without Exclusion Zone • Ability To Program Rv Syncronized Lv Only Pacing Mode • Should Have In-Clinic Optimization Capability • Compatible With Quadripolar Lead Options • Ability To Automatically Select The Best Pacing Vector Through Vector Express • Should Be Able To Minimize Rv Pacing • Should Be Able To Deliver 35J Energy • Should Have Capture Management In Ra, Rv And Lv • Ability To Withhold Shock In Cases Of Rv Noise • Ability To Withhold Shock In Cases Of T-Wave Oversensing • Should Have Algorithms To Manage And Treat Atrial Arrhythmias • Should Have Rate Drop Response To Counter Neurocardiogenic Syncope • Should Audibly Alert The Patient In Case Of Rv Noise & Lead Failure. • Should Monitor The Fluid Build-Up Status In A Heart Failure Patient, And Audible Alert The Patient In Case Its Critical • Should Have Atp During Charge In Vf Mode, With An Option To Make It Atp Before Charge. , Left Bundle/His Pacing * Left Bundle Pacing Lead/His Bundle Pacing Lead With Sheath And All The Accessories Used. * Deflectable Sheath Should Be Quoted Separately. , Fixed Tip Deflectable E.P. Catheters, All Curve. , Bidirectional 7F E.P. Catheter With Tip Electrode Of 4 And 5 Mm, All Curves. , Decapolar Coronary Sinus Catheter For Jugular/ Subclavian/Femoral Insertion, Fixed And Deflectable Tip, 5 F & 7F With Connector. , Parahisian Diagnostic Deflectable Catheter, Octapolar Configuration Catheter. , 20 Pole Deflectable Catheter For Atrial Isthmus Mapping. , Quadripolar Pacing Lead 6F/7F With Inter-Electrode Distance Of 5 Mm With Connectors. , Quadripolar Pacing Lead 6F/7F With Inter-Electrode Distance Of 5 Mm Withoutconnectors. , 4 And 5 Mm Tip Quadripolar Tip Deflectable Rf Ablation Catheter 7F, All Curves. , Thermocool Ablation Catheter. , Connecting Cables For Eps Catheter And Connectors. , Regular Thermistor/Thermocouple Rf Ablation Catheter. , Radio Frequency Ablation Catheter (4Mm) Compatible With Any Make Generator With Connector(7F), Different Curves, Push-Pull Technology. , Radio Frequency Ablation Catheter (8Mm) Compatible Any Make With Connector (7F), Different Curves, Push-Pull Technology. , Impedance Patches. , Balloon Catheter For Non-Contact Mapping Of Arrhythmias. , Radiofrequency Ablation Saline Cooled 4Mm Catheter Compatible With Any Make With Connector (7F). , Introducer Sheath With Haemostatic Valve And Locking Hub (8F/8.5F,12 Cm). , Introducer Sheath With 2 Port Haemostatic Valve And Locking Hub (10 &12F,12 Cm) , Introducer Sheath With 3 Port Haemostatic Valve And Locking Hub (12 &14F,12 Cm). , 7F 4Mm Bidirectional Steerable Ablation Catheter With Autolock Mechanism (All Curves) With Connector. , 7F 8Mm Bidirectional Steerable Ablation Catheter With Autolock Mechanism (All Curves) With Connector. , Connector For Radiofrequency Ablation Catheter Compatible With Ablator And Catheter Of Any Make Connector For Radiofrequency Ablation Catheter Compatible With Any Make. , Connector For Radiofrequency Ablation Catheter Compatible With Any Make. , Radiofrequency Ablation Catheter Unidirectional Def. Curve * 6/7Fr Size With 4Mm Tip Electrode. * 2-5-2 Mm Inter-Electrode Spacing. * 92-115Cm Insertion Length * Single Thermistor/Thermocouple Sensor With Connector , Radiofrequency Ablation Catheter Unidirectional Def. Curve * Polyurethane Coating With Bi-Directional Deflectable Curve, * 7Fr Size With 8Mm Tip Electrode And 1-6-2Mm Inter Electrode Spacing. * 115Cm Insertion Length, Single Long Thermocouple Sensor With Connector. , Irrigated Tip Ablation Catheter * Polyurethane Coating With Bi Directional Deflectable Curve. * 7Fr Size With 3.5Mm Tip Electrode * 6 Side-Holes For Open Loop Irrigation At The Tip Electrode, * 2-5-2 Mm Inter-Electrode, * Spacing.115Cm Insertion Length, Single Thermocouple Sensor With Connector. , Indifferent Patch Electrode (Reusable) With Connecting Cable. , Tubing For Irrigated Catheters Compatible With Cool Flow Pump. , Fixed Curve Quadripolar Electrophysiology Catheter (All Curve, 5-7F) With Connector. , Fixed Quadripolar Catheter Pre-Curve Shape For His Position. , Deflectable Quadripolar Electrophysiology Catheter (All Curve, 5-7F) With Connector. , Fixed Curve Deca-Polar Catheter For Coronary Sinus Mapping (All Curve, 5- 7F) With Connector. , Deflectable Deca -Polar Catheter For Coronary Sinus Mapping (All Curve, 5- 7F) With Connector. , Duo Deca-Polar Electrophysiology Catheter-20 Poles With Connector. , Bipolar Pacing Leads. 5F, 6F, &7F. , Balloon Tipped Pacing Leads 6F And & F. , List Of Consumables For Intervention (Cardiology Department) , Adult Femoral Introducer Sheath With Haemostatic Valve In A Kit Containing Puncture Needle And 0.038” Guide Wire. 4 To 7F. , Pediatric Femoral Introducer Sheath With Haemostatic Valve In A Kit Containing Puncture Needle , Adult And Pediatric Puncture Needle , Radial Introducer Sheath With Patent Unique Cross Cut Design Haemostatic Valve, 20Gx2 Puncture Needle With Plastic Iv Catheter And 0.025 Radifocus Mini Plastic Guidewire , Angiographic Guide Wire; Ptfe Coated; ‘J’ Tip & Straight Tip; Diameter 0.021”, 0.025,00.032, 0.035, 0.038 ; Length 120-150 (Regular Length). , Angiographic Guide Wire; Ptfe Coated; ‘J’ Tip & Straight Tip; Diameter 0.021”, 0.025,00.032, 0.035, 0.038 ; Length 250-260 Cm Exchange Length , Angiographic Guide Wire; Hydrophilic Coated; ‘J’ Tip & Straight Tip; Diameter 0.021”, 0.025,0,0.032, 0.035, 0.038 ; Length 120-150 (Regular Length , Angiographic Guide Wire; Hydrophilic Coated; ‘J’ Tip & Straight Tip; Diameter 0.021”, 0.025,0,0.032, 0.035, 0.038 ; Length 250-260 Cm (Exchange Length) , Three Way Stop Cock With One Male And Two Female Ports And Freely Rotating Adapter For Coronary Angiography. , Manifold - Two & Three Ports With Knobs To Turn “Right” When Open. , Radial Artery Compression Band Consists Of Two Balloons Specially Designed For Spot Compression Of The Radial Puncture Site , Short Connecting Pressure Line Of 20-30 Cm With Male Port In One Side And Female Port In The Other Side , High Pressure Injector Line To Withstand Pressure Up To 1200 Psi, 75-100 Cm Length With Luer Lock Male Port And Rotator. , Pressure Line: 120-150 Cm, 4-6 Mm, Compatible With Manifold And Three-Way Ports , Amplatzer Super Stiff Guide Wire, All Available Length And Diameters , Contrast Injecting Luer Lock Controlled Syringe 2, 5, 10 Cc With And Without Finger Grip , Short Tube Of 12 To 15 Inches To Connect To Touhyborst , Y-Connector Hemostatic Valve With Spring Type Push And Release Mechanism , Inflation Device With Manometer Up To 30 Atmosphere (Easy To Operate With Luminescent Dial) , Disposable Sterile Patient Drape With Pre-Shaped Circular Access For Both Radial And Femoral Approach During Cardiac Catheterization. , Disposal Sterile Cath Trolley Sheet. , Disposable Sterile Plastic Drape Sheet Used During Cardiac Catheterization , Sterile Adhesive Transparent Incision Drape; Absorbent And Completely Impervious To Fluids; Sizes 30-40 Cm X 25-40 Cm And 20-25 Cm X 10-15 Cm; Should Be Transparent With A Non-Glare Surface; Should Be Bacterial Proof And Water Proof , Disposable Gown Of Non-Woven Material With Elastic Wrist Bands, In All Sizes, With Fasteners , Disposable Sterile Linen/ Gauge Swabs Used During Cardiac Catheterization , Special Catheter For Cardiac Cath And Angio. All Sizes 4F To 7F: A. Swan Ganz Catheter B. Berman Cath C. Nih D. Counard Catheter E. Head Hunter Catheter F. Simmons Catheter G. Pig Tail Catheter Straight H. Pigtail Catheter With Markers I. Angled Pig Tail Catheter J. Vtk Catheter , Coronary Angiography Diagnostic Catheters 100 Cm Or Longer For Femoral Approach And Various Curves (Wherever Applicable) Of 3.0, 3.5, 4.0, 4.5, 5.0 A. Judkins Left 5F/6F B. Judkins Right 5F/6F C. Amplatz Left (Ali/Alii/Aliii) 5F/6F D. Amplatz Right (Ari/Arii) 5F/6F E. I.M.A. Catheter 5F/6F F. Right Coronary Catheter Not Requiring Torque (Ntr) 5F/6F G. Multipurpose Ai, Ii 5F/6F H. Multipurpose Bi, Ii 5F/6F I. 3Drc (Williams Catheter, 5.2 , Radial Diagnostic Catheter With The Unique Tiger Curve Which Enables Angiography Of Right And Left Coronary Arteries Using Either Radial Or Brachial Approach , Ptca Guiding Catheter, 100 Cm Long. It Should Be Large Lumen Braided, Inner Layer Coated With Ptfe. It Should Have Atraumatic Soft Tip With Radio Opaque Marker Band At The Tip. A. Judkins Left With/ Without Side Holes (Curves 3, 3.5, 4, 5Cm) Size5f/6F/7F/8F B. Judkins Left With Short Tip (Curves 3, 3.5, 4, 5 Cm), Size5f/6F/7F/8F. C. Judkins Rightwith/Without Side Holes (Cvs 3, 3.5, 4, 5Cm) Size5f/6F/7F/8F D. Judkins Right With Short Tip (Curves 3, 3.5, 4, 5 Cm), Size 5F/6F/7F/8F E. Ima Guiding Catheter, 5F/6F/7F F. Multipurpose (Ai, Aii), 5F/6F/7F/8F G. Multipurpose (Bi, Bii), 5F/6F/7F/8F H. Amplatzleft With/ Without Side Holes (Curves Al0.75, Al1, Al1.5, Al2, Al3),5F/6F/7F/8F I. Amplatz Right With/Without Side Holes (Curves Al0.75, Al1, Al1.5, Al2, Al3), 5F/F/7F/8F J. Voda Left, 5F/6F/7F/8F K. Voda Right, 5F/6F/7F/8F L. Left Coronary Bypass Guide Catheter, 6F/7F M. Right Coronary Bypass Guide Catheter, 6F/7F N. Contra Lateral Support (Cls) Left Without Side Holes, 5F/6F/7F/8F O. Contra Lateral Support (Cls) Left With Side Hole, 5F/6F/7F/8F P. Contra Lateral Support (Cls) Right Without Side Hole, 5F/6F/7F/8F Q. Contra Lateral Support (Cls) Right With Side Hole, 5F/6F/7F/8F R. 3D Right Guiding Catheter Without Side Hole, 6F/7F S. 3D Right Guiding Catheter With Side Hole, 6F/7F T. Hockey Stick Guiding Catheter, 6F/7F U. Shepherd Crook Right Type Guiding (Curves 3.5, 4, 5), 6F/7F V. Head Hunter Guiding Catheter, 6F/7F W. Ikari Guide 6F,&F , Ptca Guide Wire With Ptfe Coating Over Shaft, Polymer Sleeve Length Of 20Cm, Tip Load Of 0.8 Gm, Tip Size Of 0.014”, Tip Radiopacity Of 3Cm * 180-190 Cm Long , Ptca Guide Wire With Ptfe Coating Over Shaft, Polymer Sleeve Length Of 20Cm, Tip Load Of 0.8 Gm, Tip Size Of 0.014”, Tip Radiopacity Of 3Cm * 280-300 Cm Long , Ptca Guide Wire With Ptfe Coating Over Shaft, Polymer Sleeve Length Of 20 Cm, Tip Load Of 0.8 Gm, Tip Size Of 0.009”, Tip Radiopacity Of 16 Cm * 180-190 Cm Long , Ptca Guide Wire With Ptfe Coating Over Shaft, Polymer Sleeve Length Of 20 Cm, Tip Load Of 0.8 Gm, Tip Size Of 0.009”, Tip Radiopacity Of 16 Cm * 280-300 Cm Long , Ptca Extra-Support Guide Wire With Ptfe Coating Over Shaft, Tip Load Of 0.7 Gm, Tip Size Of 0.014”, Spring Coil Of 4 Cm And Tip Radiopacity Of 4 Cm *180-190 Cm Long , Ptca Extra-Support Guide Wire With Ptfe Coating Over Shaft, Tip Load Of 0.7 Gm, Tip Size Of 0.014”, Spring Coil Of 4 Cm And Tip Radiopacity Of 4 Cm *280-300 Cm Long , Ptca Guide Wire For Cto With Ptfe Coating Over Shaft, Tip Size Of 0.014”, Tip Radiopacity Of 11 Cm And Spring Coil Of 11 Cm, Length Of 180-190 Cm Tip Load Of * 3Gm , Ptca Guide Wire For Cto With Ptfe Coating Over Shaft, Tip Size Of 0.014”, Tip Radiopacity Of 11 Cm And Spring Coil Of 11 Cm, Length Of 180-190 Cm Tip Load Of *4.5Gm , Ptca Guide Wire For Cto With Ptfe Coating Over Shaft, Tip Size Of 0.014”, Tip Radiopacity Of 11 Cm And Spring Coil Of 11 Cm, Length Of 180-190 Cm Tip Load Of *6Gm , Ptca Guide Wire For Cto With Ptfe Coating Over Shaft, Tip Size Of 0.014”, Tip Radiopacity Of 11 Cm And Spring Coil Of 11 Cm, Length Of 180-190 Cm Tip Load Of *12Gm , Ptca Guide Wire For Cto With Extra-Support, Tip Load Of 9 Gm, Tip Size Of 0.009”, Length 180-190 Cm, With *Spring Coil And Tip Radiopacity Of 11 Cm , Ptca Guide Wire For Cto With Extra-Support, Tip Load Of 9 Gm, Tip Size Of 0.009”, Length 180-190 Cm, With * Spring Coil And Tip Radiopacity Of 20 Cm , Joint Less Spring Coil 0.014” One Piece Core Ptca Guide Wire With Tip Radiopacity 3 Cm, Length 180 Cm * Tip Load 0.7 Gm , Joint Less Spring Coil 0.014” One Piece Core Ptca Guide Wire With Tip Radiopacity 3 Cm, Length 180 Cm * Tip Load 0.5 Gm , Ptca Guide Wires, 0.014”, 180-190 Cm Long, Nitinol Distal Super Elastic Core For Kink Resistance And Shape Retention, Silicon Coating For Distal 2 Cm And Hydrophilic Coating Of Rest Of The Wire Length * Tip Load Of 1.0 Gm , Ptca Guide Wires, 0.014”, 180-190 Cm Long, Nitinol Distal Super Elastic Core For Kink Resistance And Shape Retention, Silicon Coating For Distal 2 Cm And Hydrophilic Coating Of Rest Of The Wire Length * Tip Load Of 0.6 Gm , Ptca Guide Wires, 0.014”, 180-190 Cm Long, Nitinol Distal Super Elastic Core For Kink Resistance And Shape Retention, Silicon Coating For Distal 2 Cm And Hydrophilic Coating Of Rest Of The Wire Length * Tip Load Of 3.6 Gm , Steerable Ptca Guide Wire With Floppy Tip, Elastinite Core, Soft Shaping Ribbon Tip And Hydrophilic Or Hydrophobic Coating * 180-190 Cm. , Steerable Ptca Guide Wire With Floppy Tip, Elastinite Core, Soft Shaping Ribbon Tip And Hydrophilic Or Hydrophobic Coating. * 280-300 Cm. , Steerable Ptca Extra Support Guide Wire With Durasteel Core Material, Core To Tip Design, Floppy Tip *With Hydrophobic Coating , Steerable Ptca Extra Support Guide Wire With Durasteel Core Material, Core To Tip Design, Floppy Tip *With Hydrophilic Coating , Steerable Pta High Support Guide Wire Of 0.018”, Body Ptfe/Hydrophobic Coated, Distal Hydrophilic Coating, Distal Radiopacity Of 2 Cm * 180-190 Cm Long , Steerable Pta High Support Guide Wire Of 0.018”, Body Ptfe/Hydrophobic Coated, Distal Hydrophilic Coating, Distal Radiopacity Of 2 Cm * =300 Cm Long , Ptra Guide Wire For Renal Angioplasty, Diameter 0.018”, 100- 110 Cm Long , Steerable Pta Guide Wire With Floppy Tip, Titanium Stainless Steel Alloy Core, Extra-Support Of 0.018” Diameter, =300 Cm Long. A. Tip Non-Hydrophilic B. Tip Hydrophilic , Ptca Pre-Dilatation, Monorail Balloon (Semi Compliant). Hypotube Shaft Design, Low Entry Profile (=0.017”) And 5F Guide Catheter Compatibility. Diameters (Mm): 1.2/1.25, 1.5, 2.0, 2.5, 3, 3.5, 4.0. Length: Minimum 6-8 Mm To Maximum 20 Mm Or More , Ptca Pre-Dilatation Semi-Compliant Balloon, With Push And Flex Technology, Lowest Tip Entry Profile Of =0.017”, Crossing Profile Of =0.021”, Low Profile And Marker For Better Visibility, Stepwise Transition Stiffening For More Pushability. Diameter (Mm): 1.2/1.25, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0. Length: Minimum 6-8 Mm To Maximum 20 Mm Or More , High Pressure Non-Compliant Balloon Smooth, Rounded Distal Tip And No Edge Over-Dilatation At Higher Pressure; With Least Balloon Overhang At The Edges. Diameter (Mm): 2.5, 2.75, 3.0, 3.25, 3.5, 3.75, 4, Length (Mm): Minimum 6-8Mm To =20 Mm , Ultra-Low Entry Profile Semi Compliant Balloon With .40Mm Or 0.016” And Entry Profile From 1.25*10 To 2.25*10 Remains Same For Exceptional Cross Ability Even With Higher Diameter Balloon A. Otw Over 0.018” Guidewire. B.Monorail Over 0.018” Guidewire , Peripheral Long Balloon, Hydrophobic Coating, 4F Sheath Compatible, Various Diameters Of 2-4 Mm. Length: 20 To =200 Mm, Otw Over 0.014” Guidewire. , Coronary Microcatheter With Distal Diameter Of 1.8 Fr Or Less, Proximal Diameter 2.6F, Ptfe Coated Inner Layer, And Distal Hydrophilic Coating At The Outer Layer, Flexible Tip With Outer And Inner Taper With Gold Marker At Distal Tip For Enhanced Distal Visibility To Cross Difficult Lesions * 130-135 Cm Long , Coronary Microcatheter With Distal Diameter Of 1.8 Fr Or Less, Proximal Diameter 2.6F, Ptfe Coated Inner Layer, And Distal Hydrophilic Coating At The Outer Layer, Flexible Tip With Outer And Inner Taper With Gold Marker At Distal Tip For Enhanced Distal Visibility To Cross Difficult Lesions * 150-160 Cm Long , Drug Eluting Coronary Balloon. (All Diameters And Sizes Available) A. Paclitaxel Eluting Balloon B. Sirolimus Eluting Balloon , Ivc Filter A. Temporary B. Permanent (Mri & Non Mri Compatible) , Rota Burr For Rotational Coronary Atherectomy, 1.25- 2.0 Mm. A. Burr Only. B. Burr With Advancer. C. Advancer Only , Guide Wire For Rotational Coronary Atherectomy A. Floppy. B. Extra Support , Guideliner Catheter, 6F/7F, Rapid Exchange With 145-150 Cm Working Length, Tip Radiopaque Marker , Guide Extension Catheter Other Make, 145-150 Cms Working Length , Coronary Micro-Catheter , Coronary Mother And Child Catheter , Coronary Covered Stents All Sizes , Balloon Mounted Monorail 0.014 Compatible Stainless Steel Renal Stent, All Types And Sizes , Balloon Mounted Monorail 0.014 Compatible Cobalt Chromium Renalstent, All Types And Sizes , Peripheral Stainless Steel Stent Otw/Monorail ,Balloon Mounted, All Types And Sizes , Peripheral Stainless Steel Stent, Otw/Monorail Self Expanding, All Types And Sizes , Peripheral Cobalt Chromium Stents, Otw/Monorail Self Expanding All Types And Sizes , Peripheral Cobalt Chromium Stent, Otw/Monorail, Balloon Mounted, All Types And Sizes , Peripheral Covered Stents , Nitinol Peripheral Stent, Otw/Monorail, All Types And Sizes , Peripheral Drug Eluting Balloon , Ptmc Accessories Set Complete , Spring Wire For Ptmc. , Stylet For Ptmc Balloon. , Septal Dilator For Ptmc. , Mitral Balloon All Sizes. , Mitral Balloon All Sizes. , Brokenbrough Needle Adult And Pediatric. , Mullin Sheaths Adult All Sizes. , Mullins Sheath, Paediatrics All Sizes. , Shuttle Sheaths All Sizes. , Carotid Stents All Sizes Self-Expanding/Balloon Expandable. , Filterwie For Carotid Angioplasty. , Cross Over Sheaths All Sizes. , Pulmonary Valvuloplasty Catheters. (Pediatric) , Pulmonary Valvuloplasty Catheters (Adults).All Sizes. , Aortic Valvuloplasty Catheters (Pediatric). , Aortic Valvuloplasty Catheters (Adults). , Balloons For Valvuloplasty,( Adult&Pediatric) All Sizes. , Endomyocardial Biopsy Catheters, All Sizes. , Intravasacular Retrieval Snares. , Snares With 3 Loops. , Artery Retrieval Snares. , Micro Vena Snares. , Destination Sheath For Carotids. All Sizes. , Pda Coils All Sizes. , Pda Closure Devices All Types And Sizes. (Quote Separately) , Asd Closure Devices All Types And Sizes. (Quote Separately) , Vsd Closure Devices All Types And Sizes. (Quote Separately) , Delivery System For Asd, Complete Set. , Delivery System For Vsd, Complete Set. , Delivery System For Pda, Complete Set. , Vasacular Plugs All Types And Sizes. , Cp Stent All Sizes. , Bib Stent For Coarctation. , Covered Stent For Coarctation. , Pva Particles All Sizes. , Micro Coils For Avm. , Cyanoacrylate Glue. , Microcatheter For Uterine Artery Embolization. , Ffr Wire Which Should Be Hydrophilic And With A Tip Load 0.6G. Should Be Usfda Approved. , Oct Catheter For Advanced, High Resolution Imaging. Its Tip Should Be Low Profile (2.7F), And Catheter Should Be Compatible With Standard 0.014 Guide Wires , Ivus Catheter With Single Rotating/Mechanical Transducer Driven By A Flexible Drive Cable With Minimum 20 Mhz Frequency. , Embolectomy Catheter 2 × 2 For Bas. , Non Ionic Iodine Contrast Iohexol 300 Mg X50 Ml Pack , Non Ionic Iodine Contrast Iohexol 300 Mg X100 Ml Pack , Non Ionic Iodine Contrast Iohexol 350 Mg X50 Ml Pack , Non Ionic Iodine Contrast Iohexol 350 Mg X100 Ml Pack , Iodixanol 320 Mg Iodine Per Ml. X 50 Ml Pack , Iodixanol 320 Mg Iodine Per Ml. X100 Ml Pack , Iomeperol 400Mg Iodine Per Ml. X 100 Ml Pack , Iobitridol 370Mg Iodine Per Ml X 100 Ml , Iopromide 300Mg Iodine Per Ml. 50 Ml Pack , Iopromide370 Mg Iodine Per Ml. 50 Ml Pack , Iopromide 300Mg Iodine Per Ml. 100 Ml Pack , Iopromide 370Mg Iodine Per Ml. 100 Ml Pack , Renal Denervation Therapy - Spiral Multi Electrode Renal Denervation Catheter Essential Features: A. The Catheter Should Be Able To Provide Plug And Play Design With A Uniform Sizing That Fits The Anatomy Of The Renal Artery, Accessory And Brand Vessels In The Diameter Of 3-8Mm. B. It Should Be Having A Multi-Electrode System That Covers The 4 Quadrants Simultaneously For A Circumferential Ablation Giving Complete Denervation As The Result. C. Rapid Exchange Design Compatible With 0.014” Guidewire. D. Guidewire Retraction Used To Deploy The Spiral Electrode Array. E. Rx Joint: 30Cm From Distal Tip. F. Vessel Diameter Treatment Range 3-8Mm. G. Four Independently Controlled Rf Monopolar Gold Electrodes Spaced 6.5Mm Apart (Distal Self-Expanding Array Of 4 Electrodes, Which Is Made Of Gold, Radio-Opaque And 1.5Mm In Length). H. Treatment Length 17-21Mm If All Electrodes Are Activated. I.Tip Length 5Mm J. Tip Marker: 1Mm Proximal Of Distal Tip (Platinum/ Iridium Alloy As Tip Marker) K. Femoral Shaft Marker 55Cm From Distal Tip L. Sterilization Process: E-Beam And 10-6Sal M. Shelf Life: Three Years. , Endovascular Repair Of Thoracic And Abdominal Aortic Aneurysm(Evar/Tevar) Stent Graft Of All Size: 18-32Mm Diameter) Infra Renal Neck Length (Minimum – 15Mm) Material – Ptfe/Polyester Trifurcated Or Aorto – Unilliac Configuration , Trans Catheter Aortic Valve Replacement (Tavr) - Self Expanding Valve (Sev) - Balloon Expendable Valve (Bev) Specification Of Evolut Fx Self-Expanding, Recapturable Supra-Annular Porcine Pericardium Aortic Tavr Valve With An External Skirt And 3Mm Depth Markers, Delivered Through A Single-Spine Catheter, Designed To Treat Annulus Ranging From 17 To 30Mm. Evolut Fx 23-34 Evolut Pro Plus Self-Expanding, Recapturable Supra-Annular Porcine Pericardium Aortic Tavr Valve With An External Skirt Designed To Treat Annulus Ranging From 17 To 30Mm. Evolut Pro+ 23-34 , Technical Specifications Of Pacemakers, Other Devices And Consumables For Intervention (Cardiology Department). Separate Rates Should Be Quoted For Items Of Boq Sr. No.396 To 591 For Usfda Certified , Vvi * Pacemaker With Lead &Accessories. All Single Chamber Modes And Basic Multi-Programmable Parameters With Preferably Autosensing And Autocapture/Output Management Facilities. * Must Have Ventricular Capture Management. * Monitor The Integrity Of Lead And Switch Polarity In Case Of Issue. * The Size Of Lead Should Be 7F Or Less. * The Lead Must Be Steroid Eluting And Should Be Both Bipolar And Unipolar Configuration. * Must Have Both Active And Passive Fixation Endocardial Leads Available. * Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla. * Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. * Company Must Quote Only The Latest Model Of Devices Commercially Available. , Vvir • Pacemaker With Lead & Accessories. • All Single Chamber Modes And Basic Multi-Programmable Parameters With Preferably Autosensing And Autocapture /Output Management Facilities. • Must Have Ventricular Capture Management. • Monitor The Integrity Of Lead And Switch Polarity In Case Of Issue. The Size Of Lead Should Be 7F Or Less. • The Lead Must Be Steroid Eluting And Should Be Both Bipolar And Unipolar Configuration. • Must Have Both Active And Passive Fixation Endocardial Leads Available. • Must Have Rate Response Which Allows Rate Profile Optimization. • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla. • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. • Company Must Quote Only The Latest Model Of Devices Commercially Available. , Vvir (Paediatric) • Pacemaker With Lead & Accessories. • All Single Chamber Modes And With Paediatric Base Rate Upto 160Bpm And Parameters, Must Be Smallest Size Designated For Paediatrics Patient, Weight Should Be Less Than 14Gm, • Must Have Ventricular Capture Management. • The Size Of Lead Should Be 7F Or Less. • The Lead Must Be Steroid Eluting And Should Be Both Bipolar And Unipolar Configuration. • Must Have Both Active And Passive Fixation Endocardial Leads Available. • Must Have Rate Response Which Allows Rate Profile Optimization. • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla. • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. • Company Must Quote Only The Latest Model Of Devices Commercially Available. , Vvir (Mri Compatible) • Mri Conditional Pacemaker With Lead & Accessories • Should Allow Full Body At Least 1.5 T Mri Scan Preferably Without Any Restriction Zone. • Must Have Ventricular Capture Management • Monitor The Integrity Of Lead And Switch Polarity • The Size Of Lead Should Be 7F Or Less. • The Lead Must Be Steroid Eluting And Should Be Both Bipolar And Unipolar Configuration. • Must Have Both Active And Passive Fixation Endocardial Leads Available. • Must Have Rate Response Which Allows Rate Profile Optimization. • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. • Company Must Quote Only The Latest Model Of Devices Commercially Available. , Ddd • Pacemaker With Lead & Accessories • All Pacing Modes And Basic Pacing Programmable Parameters Including Hysteresis With Preferably Autosensing And Autocapture/Output Management Facilities. • Must Have Ventricular And Atrial Capture Management. • Must Minimize Ventricular Pacing By Optimizing Av Delay Automatically. • Monitor The Integrity Of Lead And Switch Polarity In Case Of Issue. • The Size Of Lead Should Be 7F Or Less. • The Lead Must Be Steroid Eluting And Should Be Both Bipolar And Unipolar Configuration. • Must Have Both Active And Passive Fixation Endocardial Leads Available. • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. • Company Must Quote Only The Latest Model Of Devices Commercially Available. , Dddr • Pacemaker With Lead & Accessories • All Pacing Modes And Basic Pacing Programmable Parameters Including Hysteresis With Preferably Autosensing And Autocapture/Output Management Facilities. • Must Have Ventricular And Atrial Capture Management. • Must Have Rate Response Which Allows Rate Profile Optimization. • Monitor The Integrity Of Lead And Switch Polarity In Case Of Issue. • The Size Of Lead Should Be 7F Or Less. • The Lead Must Be Steroid Eluting And Should Be Both Bipolar And Unipolar Configuration. • Must Have Both Active And Passive Fixation Endocardial Leads Available. • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. , Dddr Pacemaker (Mri Compatible) • Pacemaker With Lead & Accessories. • Should Allow Full Body At Least 1.5T Mri Scan Preferably Without Any Restriction Zone. • Mode Based Physiological Pacing Algorithm To Promote Intrinsic Conduction. • Patient Symptomatic Relief By Regularizing Ventricular Rhythm During Af. • Monitor The Integrity Of Lead And Switch Polarity In Case Of Issue. • The Size Of Lead Should Be 7F Or Less. • The Lead Must Be Steroid Eluting And Should Be Both Bipolar And Unipolar Configuration. • Must Have Both Active And Passive Fixation Endocardial Leads Available. • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. , Dddr ( With At/Af Management) • Pacemaker. • With All Lead & Accessories With Syncope Management & Af Prevention. • Should Allow Full Body At Least 1.5T Mri Scan Preferably Without Any Restriction Zone. • Evaluate Threshold Of Atrial & Ventricular Lead To Adjust Atrial & Ventricular Output On Daily Basis. • Automatically Adjust Sensitivity To Maintain Adequate Sensing Margins. • Dual Zone Rate Response, One For Normal Response And Other For Response During Exercise. • Mode Based Physiological Pacing Algorithm To Promote Intrinsic Conduction. • Atrial Intervention For Af Prevention By Constantly Overdriving Atrium. • Rate Drop Response For Syncope Management With Ability To Detect Both Drop Rate And Drop Size. • Atp Therapies To Terminate High-Rate Atrial Tachyarrhythmia Episodes. • The Size Of Lead Should Be 7F Or Less. • The Lead Must Be Steroid Eluting And Should Be Both Bipolar And Unipolar Configuration. • Must Have Both Active And Passive Fixation Endocardial Leads Available. • Must Have Rate Response Which Allows Rate Profile Optimization. • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required , Vdd/Vddr • With Lead & Accessories • All Vdd And Single Chamber Modes And Basic Pacing Programmable Parameters With Following Special Features. • Must Have Ventricular Capture Management. • Monitor The Integrity Of Lead And Switch Polarity In Case Of Issue • The Size Of Lead Should Be 9F Or Less. • The Lead Must Be Steroid Eluting And Should Be Both Bipolar And Unipolar Configuration. • Must Have Both Active And Passive Fixation Endocardial Leads Available. • Must Have Rate Response Which Allows Rate Profile Optimization. • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. • Company Must Quote Only The Latest Model Of Devices Commercially Available. , Implantable Loop Recorder • Mri Compatible With 1.5 &/Or 3.0 T System • Ability To Record At/Af Burden • Ability To Record Brady-/Tachy- Episodes • Patient Triggered Ecg Storage. , Aicd • Aicd Single Chamber With All Leads & Accessories. • Rv Lead Must Be 8F Or Less • All Basic Programmable Parameters With Preferably Autosensing And Auto Capture/Output Management Facilities. • Must Have Morphological Based Svt Discrimination • Must Monitor The Lead Integrity And Notify In Case Of A Suspected Failure • Must Have Shock Reduction Or Shock Guard Or Any Other Similar Technology. • Must Have Remote Patient Management Capability. • Lead Should Be Steroid Eluting. • Should Have Both Active And Passive Fixation Leads. • Standard International Warranty • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. • Company Must Quote Only The Latest Model Of Devices Commercially Available. , Aicd (Advanced) • Aicd Single Chamber With All Leads & Accessories • Defibrillator With Wireless Telemetry Without Requirement Of Additional Equipment • Should Be Able To Deliver At Least 35J Energy • Ability To Withhold Shock In Cases Of Rv Noise • Should Have Programmable Polarity Of Leads • Should Have Capture Management In Rv • Should Audibly Alert The Patient In Case Of Rv Noise & Lead Failure, And Extend Nidshould Monitor The Fluid Build-Up Status In A Heart Failure Patient And Audible Alert The Patient In Case Its Critical • Should Have Atp During Charge In Vf Mode, With An Option To Make It Atp Before Charge. • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. • Company Must Quote Only The Latest Model Of Devices Commercially Available. , Aicd • Mri Conditional Aicd Single Chamber With All Leads & Accessories • Defibrillator With Wireless Telemetry Without Requirement Of Additional Equipment • Should Be 1.5T &/Or 3T Full Body Mri Conditional Preferably Without Restriction Zone. • Should Have A Declared Longevity Of At Least 10 Years. • Should Be Able To Deliver At Least 35J Energy. • Should Have Capture Management In Rv. • Ability To Withhold Shock In Cases Of Rv Noise Or T-Wave Oversensing. • Capable Of Af Diagnosis Without Additional Lead. • Should Audibly Alert The Patient In Case Of Rv Noise & Lead Failure, And Extend Nid. • Should Monitor The Fluid Build-Up Status In A Heart Failure Patient, And Audible Alert The Patient In Case Its Critical • Should Have Atp During Charge In Vf Mode, With An Option To Make It Atp Before Charge. • Company Must Provide At Least One Programmer Exclusively To The Department Of Cardiology Igmc Shimla. • Company Must Provide Its Trained Technical Person For Each Implantation And For Follow Up Programming Whenever Required. • Company Must Quote Only The Latest Model Of Devices Commercially Available. , Aicd (Mri Compatible) • Defibrillator With Wireless Telemetry Without Requirement Of Additional Equipment • Us Fda Approved Dual Chamber Aicd With All Leads & Accessories • Defibrillator With Wireless Telemetry Without Requirement Of Additional Equipment • Should Be At Least 1.5T Full Body Mri Conditional Preferably Without Any Restriction Zone. • Should Have A Declared Longevity Of At Least 8 Years • Should Be Able To Minimize Rv Pacing • Should Be Able To Deliver At Least 35J Energy • Should Have Capture Management In Ra And Rv • Ability To Withhold Shock In Cases Of Rv Noise • Ability To Withhold Shock In Cases Of T-Wave Oversensing • Should Have Algorithms To Manage And Treat Atrial Arrhythmias • Should Have Rate Drop Response To Counter Neurocardiogenic Syncope • Should Audibly Alert The Patient In Case Of Rv Noise & Lead Failure. • Should Monitor The Fluid Build-Up Status In A Heart Failure Patient, And Audible Alert The Patient In Case Its Critical Level. , Crt-P • Biventricular Pacemaker With Atrial, Rv And Lv Leads And All Accessories • Must Have Separate Programmable Rv, Lv Lead Amplitude, Pulse Width And Vv Delay. • The Size Of Ra, Rv & Lv Leads Should Be 7F Or Less • The Leads Should Be Steroid Eluting And Should Be Bipolar And Unipolar Configuration • Should Have Both Active And Passive Fixation Ra & Rv Endocardial Leads. • Should Have Facility For Active Fixation Of Lv Lead In Cs With Both Screwing And/Or Deployable Lobes With Anchor Mechanism. • Should Have Facility For Epicardial Lv Lead Implantation. • Monitor The Integrity Of Lead And Switch Polarity In Case Of Issue • Must Have Ra, Rv And Lv Capture Management. • Must Have Remote Patient Management Capability. • Standard International Warranty. , Crt-P (Advanced) • Biventricular Pacemaker With Atrial, Rv And Lv Leads And All Accessories • Ability To Program Rv Synchronised Lv Only Pacing Mode • Should Have In-Clinic Optimization Capability • Should Have Ventricular Sense Response • Should Have Ventricular Safety Pacing In Order To Ensure 100% Crt Therapy • Should Have Capture Management In Ra, Rv And Lv • Should Monitor The Fluid Build-Up Status In A Heart Failure Patient, And Audible Alert The Patient In Case Its Critical. , Crt-D • Biventricular Pacemaker With Atrial, Rv And Lv Leads And All Accessories • Wireless Telemetry • Should Be Able To Deliver 35J Energy • Should Have Capture Management In Lv • Ability To Withhold Shock In Cases Of Rv Noise • Ability To Withhold Shock In Cases Of T-Wave Oversensing • Should Have Algorithms To Manage And Treat Atrial Arrhythmias • Should Have Rate Drop Response To Counter Neurocardiogenic Syncope • Should Audibly Alert The Patient In Case Of Rv Noise & Lead Failure. • Should Have Atp During Charge In Vf Mode, With An Option To Make It Atp Before Charge. , Crt-D (Advanced) • Biventricular Pacemaker With Atrial, Rv And Lv Leads And All Accessories • Wireless Telemetry • Should Have In-Clinic Optimization Capability • Compatible With Quadripolar Lead Options • Ability To Automatically Select The Best Pacing Vector • Should Be Able To Minimize Rv Pacing • Should Be Able To Deliver At Least 35J Energy • Should Have Capture Management In Ra, Rv And Lv • Ability To Withhold Shock In Cases Of Rv Noise • Ability To Withhold Shock In Cases Of T-Wave Oversensing • Should Have Algorithms To Manage And Treat Atrial Arrhythmias • Should Have Rate Drop Response To Counter Neurocardiogenic Syncope • Should Monitor The Fluid Build-Up Status In A Heart Failure Patient, And Audible Alert The Patient In Case Its Critical • Should Audibly Alert The Patient In Case Of Rv Noise & Lead Failure. • Should Have Atp During Charge In Vf Mode, With An Option To Make It Atp Before Charge. , Crt-D (Mri Compatible) • Biventricular Pacemaker With Atrial, Rv And Lv Leads And All Accessories. • Wireless Telemetry • Should Be 1.5T Or 3T Full Body Mri Conditional. • Should Have In-Clinic Optimization Capability • Compatible With Quadripolar Lead Options • Ability To Automatically Select The Best Pacing Vector. • Should Be Able To Minimize Rv Pacing • Should Be Able To Deliver At Least 35J Energy • Should Have Capture Management In Ra, Rv And Lv • Ability To Withhold Shock In Cases Of Rv Noise • Ability To Withhold Shock In Cases Of T-Wave Oversensing • Should Have Algorithms To Manage And Treat Atrial Arrhythmias • Should Have Rate Drop Response To Counter Neurocardiogenic Syncope • Should Audibly Alert The Patient In Case Of Rv Noise & Lead Failure. • Should Monitor The Fluid Build-Up Status In A Heart Failure Patient, And Audible Alert The Patient In Case Its Critical • Should Have Atp During Charge In Vf Mode, With An Option To Make It Atp Before Charge. , Crt-D (With Only Lv Pacing Option) • Biventricular Pacemaker With Atrial, Rv And Lv Leads And All Accessories • Wireless Telemetry • Ability To Program Rv Synchronized Lv Only Pacing Mode • Should Have In-Clinic Optimization Capability • Compatible With Quadripolar Lead Options • Ability To Automatically Select The Best Pacing Vector Through Vector Express • Should Be Able To Minimize Rv Pacing • Should Be Able To Deliver 35J Energy • Should Have Capture Management In Ra, Rv And Lv • Ability To Withhold Shock In Cases Of Rv Noise • Ability To Withhold Shock In Cases Of T-Wave Oversensing • Should Have Algorithms To Manage And Treat Atrial Arrhythmias • Should Have Rate Drop Response To Counter Neurocardiogenic Syncope • Should Audibly Alert The Patient In Case Of Rv Noise & Lead Failure. • Should Monitor The Fluid Build-Up Status In A Heart Failure Patient, And Audible Alert The Patient In Case Its Critical • Should Have Atp During Charge In Vf Mode, With An Option To Make It Atp Before Charge. , Crt-D (With Only Lv Pacing Option; Mri Compatible) • Biventricular Pacemaker With Atrial, Rv And Lv Leads And All Accessories. • Wireless Telemetry • Should Be 1.5T Or 3T Full Body Mri Conditional Without Exclusion Zone • Ability To Program Rv Syncronized Lv Only Pacing Mode • Should Have In-Clinic Optimization Capability • Compatible With Quadripolar Lead Options • Ability To Automatically Select The Best Pacing Vector Through Vector Express • Should Be Able To Minimize Rv Pacing • Should Be Able To Deliver 35J Energy • Should Have Capture Management In Ra, Rv And Lv • Ability To Withhold Shock In Cases Of Rv Noise • Ability To Withhold Shock In Cases Of T-Wave Oversensing • Should Have Algorithms To Manage And Treat Atrial Arrhythmias • Should Have Rate Drop Response To Counter Neurocardiogenic Syncope • Should Audibly Alert The Patient In Case Of Rv Noise & Lead Failure. • Should Monitor The Fluid Build-Up Status In A Heart Failure Patient, And Audible Alert The Patient In Case Its Critical • Should Have Atp During Charge In Vf Mode, With An Option To Make It Atp Before Charge. , Left Bundle/His Pacing * Left Bundle Pacing Lead/His Bundle Pacing Lead With Sheath And All The Accessories Used. * Deflectable Sheath Should Be Quoted Separately. , Fixed Tip Deflectable E.P. Catheters, All Curve. , Bidirectional 7F E.P. Catheter With Tip Electrode Of 4 And 5 Mm, All Curves. , Decapolar Coronary Sinus Catheter For Jugular/ Subclavian/Femoral Insertion, Fixed And Deflectable Tip, 5 F & 7F With Connector. , Parahisian Diagnostic Deflectable Catheter, Octapolar Configuration Catheter. , 20 Pole Deflectable Catheter For Atrial Isthmus Mapping. , Quadripolar Pacing Lead 6F/7F With Inter-Electrode Distance Of 5 Mm With Connectors. , Quadripolar Pacing Lead 6F/7F With Inter-Electrode Distance Of 5 Mm Withoutconnectors. , 4 And 5 Mm Tip Quadripolar Tip Deflectable Rf Ablation Catheter 7F, All Curves. , Thermocool Ablation Catheter. , Connecting Cables For Eps Catheter And Connectors. , Regular Thermistor/Thermocouple Rf Ablation Catheter. , Radio Frequency Ablation Catheter (4Mm) Compatible With Any Make Generator With Connector(7F), Different Curves, Push-Pull Technology. , Radio Frequency Ablation Catheter (8Mm) Compatible Any Make With Connector (7F), Different Curves, Push-Pull Technology. , Impedance Patches. , Balloon Catheter For Non-Contact Mapping Of Arrhythmias. , Radiofrequency Ablation Saline Cooled 4Mm Catheter Compatible With Any Make With Connector (7F). , Introducer Sheath With Haemostatic Valve And Locking Hub (8F/8.5F,12 Cm). , Introducer Sheath With 2 Port Haemostatic Valve And Locking Hub (10 &12F,12 Cm) , Introducer Sheath With 3 Port Haemostatic Valve And Locking Hub (12 &14F,12 Cm). , 7F 4Mm Bidirectional Steerable Ablation Catheter With Autolock Mechanism (All Curves) With Connector. , 7F 8Mm Bidirectional Steerable Ablation Catheter With Autolock Mechanism (All Curves) With Connector. , Connector For Radiofrequency Ablation Catheter Compatible With Ablator And Catheter Of Any Make Connector For Radiofrequency Ablation Catheter Compatible With Any Make. , Connector For Radiofrequency Ablation Catheter Compatible With Any Make. , Radiofrequency Ablation Catheter Unidirectional Def. Curve * 6/7Fr Size With 4Mm Tip Electrode. * 2-5-2 Mm Inter-Electrode Spacing. * 92-115Cm Insertion Length * Single Thermistor/Thermocouple Sensor With Connector , Radiofrequency Ablation Catheter Unidirectional Def. Curve * Polyurethane Coating With Bi-Directional Deflectable Curve, * 7Fr Size With 8Mm Tip Electrode And 1-6-2Mm Inter Electrode Spacing. * 115Cm Insertion Length, Single Long Thermocouple Sensor With Connector. , Irrigated Tip Ablation Catheter * Polyurethane Coating With Bi Directional Deflectable Curve. * 7Fr Size With 3.5Mm Tip Electrode * 6 Side-Holes For Open Loop Irrigation At The Tip Electrode, * 2-5-2 Mm Inter-Electrode, * Spacing.115Cm Insertion Length, Single Thermocouple Sensor With Connector. , Indifferent Patch Electrode (Reusable) With Connecting Cable. , Tubing For Irrigated Catheters Compatible With Cool Flow Pump. , Fixed Curve Quadripolar Electrophysiology Catheter (All Curve, 5-7F) With Connector. , Fixed Quadripolar Catheter Pre-Curve Shape For His Position. , Deflectable Quadripolar Electrophysiology Catheter (All Curve, 5-7F) With Connector. , Fixed Curve Deca-Polar Catheter For Coronary Sinus Mapping (All Curve, 5- 7F) With Connector. , Deflectable Deca -Polar Catheter For Coronary Sinus Mapping (All Curve, 5- 7F) With Connector. , Duo Deca-Polar Electrophysiology Catheter-20 Poles With Connector. , Bipolar Pacing Leads. 5F, 6F, &7F. , Balloon Tipped Pacing Leads 6F And & F. , List Of Consumables For Intervention (Cardiology Department) , Adult Femoral Introducer Sheath With Haemostatic Valve In A Kit Containing Puncture Needle And 0.038” Guide Wire. 4 To 7F. , Pediatric Femoral Introducer Sheath With Haemostatic Valve In A Kit Containing Puncture Needle , Adult And Pediatric Puncture Needle , Radial Introducer Sheath With Patent Unique Cross Cut Design Haemostatic Valve, 20Gx2 Puncture Needle With Plastic Iv Catheter And 0.025 Radifocus Mini Plastic Guidewire , Angiographic Guide Wire; Ptfe Coated; ‘J’ Tip & Straight Tip; Diameter 0.021”, 0.025,00.032, 0.035, 0.038 ; Length 120-150 (Regular Length). , Angiographic Guide Wire; Ptfe Coated; ‘J’ Tip & Straight Tip; Diameter 0.021”, 0.025,00.032, 0.035, 0.038 ; Length 250-260 Cm Exchange Length , Angiographic Guide Wire; Hydrophilic Coated; ‘J’ Tip & Straight Tip; Diameter 0.021”, 0.025,0,0.032, 0.035, 0.038 ; Length 120-150 (Regular Length , Angiographic Guide Wire; Hydrophilic Coated; ‘J’ Tip & Straight Tip; Diameter 0.021”, 0.025,0,0.032, 0.035, 0.038 ; Length 250-260 Cm (Exchange Length) , Three Way Stop Cock With One Male And Two Female Ports And Freely Rotating Adapter For Coronary Angiography. , Manifold - Two & Three Ports With Knobs To Turn “Right” When Open. , Radial Artery Compression Band Consists Of Two Balloons Specially Designed For Spot Compression Of The Radial Puncture Site , Short Connecting Pressure Line Of 20-30 Cm With Male Port In One Side And Female Port In The Other Side , High Pressure Injector Line To Withstand Pressure Up To 1200 Psi, 75-100 Cm Length With Luer Lock Male Port And Rotator. , Pressure Line: 120-150 Cm, 4-6 Mm, Compatible With Manifold And Three-Way Ports , Amplatzer Super Stiff Guide Wire, All Available Length And Diameters , Contrast Injecting Luer Lock Controlled Syringe 2, 5, 10 Cc With And Without Finger Grip , Short Tube Of 12 To 15 Inches To Connect To Touhyborst , Y-Connector Hemostatic Valve With Spring Type Push And Release Mechanism , Inflation Device With Manometer Up To 30 Atmosphere (Easy To Operate With Luminescent Dial) , Disposable Sterile Patient Drape With Pre-Shaped Circular Access For Both Radial And Femoral Approach During Cardiac Catheterization. , Disposal Sterile Cath Trolley Sheet. , Disposable Sterile Plastic Drape Sheet Used During Cardiac Catheterization , Sterile Adhesive Transparent Incision Drape; Absorbent And Completely Impervious To Fluids; Sizes 30-40 Cm X 25-40 Cm And 20-25 Cm X 10-15 Cm; Should Be Transparent With A Non-Glare Surface; Should Be Bacterial Proof And Water Proof , Disposable Gown Of Non-Woven Material With Elastic Wrist Bands, In All Sizes, With Fasteners , Disposable Sterile Linen/ Gauge Swabs Used During Cardiac Catheterization , Special Catheter For Cardiac Cath And Angio. All Sizes 4F To 7F: A. Swan Ganz Catheter B. Berman Cath C. Nih D. Counard Catheter E. Head Hunter Catheter F. Simmons Catheter G. Pig Tail Catheter Straight H. Pigtail Catheter With Markers I. Angled Pig Tail Catheter J. Vtk Catheter , Coronary Angiography Diagnostic Catheters 100 Cm Or Longer For Femoral Approach And Various Curves (Wherever Applicable) Of 3.0, 3.5, 4.0, 4.5, 5.0 A. Judkins Left 5F/6F B. Judkins Right 5F/6F C. Amplatz Left (Ali/Alii/Aliii) 5F/6F D. Amplatz Right (Ari/Arii) 5F/6F E. I.M.A. Catheter 5F/6F F. Right Coronary Catheter Not Requiring Torque (Ntr) 5F/6F G. Multipurpose Ai, Ii 5F/6F H. Multipurpose Bi, Ii 5F/6F I. 3Drc (Williams Catheter, 5.2 , Radial Diagnostic Catheter With The Unique Tiger Curve Which Enables Angiography Of Right And Left Coronary Arteries Using Either Radial Or Brachial Approach , Ptca Guiding Catheter, 100 Cm Long. It Should Be Large Lumen Braided, Inner Layer Coated With Ptfe. It Should Have Atraumatic Soft Tip With Radio Opaque Marker Band At The Tip. A. Judkins Left With/ Without Side Holes (Curves 3, 3.5, 4, 5Cm) Size5f/6F/7F/8F B. Judkins Left With Short Tip (Curves 3, 3.5, 4, 5 Cm), Size5f/6F/7F/8F. C. Judkins Rightwith/Without Side Holes (Cvs 3, 3.5, 4, 5Cm) Size5f/6F/7F/8F D. Judkins Right With Short Tip (Curves 3, 3.5, 4, 5 Cm), Size 5F/6F/7F/8F E. Ima Guiding Catheter, 5F/6F/7F F. Multipurpose (Ai, Aii), 5F/6F/7F/8F G. Multipurpose (Bi, Bii), 5F/6F/7F/8F H. Amplatzleft With/ Without Side Holes (Curves Al0.75, Al1, Al1.5, Al2, Al3),5F/6F/7F/8F I. Amplatz Right With/Without Side Holes (Curves Al0.75, Al1, Al1.5, Al2, Al3), 5F/F/7F/8F J. Voda Left, 5F/6F/7F/8F K. Voda Right, 5F/6F/7F/8F L. Left Coronary Bypass Guide Catheter, 6F/7F M. Right Coronary Bypass Guide Catheter, 6F/7F N. Contra Lateral Support (Cls) Left Without Side Holes, 5F/6F/7F/8F O. Contra Lateral Support (Cls) Left With Side Hole, 5F/6F/7F/8F P. Contra Lateral Support (Cls) Right Without Side Hole, 5F/6F/7F/8F Q. Contra Lateral Support (Cls) Right With Side Hole, 5F/6F/7F/8F R. 3D Right Guiding Catheter Without Side Hole, 6F/7F S. 3D Right Guiding Catheter With Side Hole, 6F/7F T. Hockey Stick Guiding Catheter, 6F/7F U. Shepherd Crook Right Type Guiding (Curves 3.5, 4, 5), 6F/7F V. Head Hunter Guiding Catheter, 6F/7F W. Ikari Guide 6F,&F , Ptca Guide Wire With Ptfe Coating Over Shaft, Polymer Sleeve Length Of 20Cm, Tip Load Of 0.8 Gm, Tip Size Of 0.014”, Tip Radiopacity Of 3Cm * 180-190 Cm Long , Ptca Guide Wire With Ptfe Coating Over Shaft, Polymer Sleeve Length Of 20Cm, Tip Load Of 0.8 Gm, Tip Size Of 0.014”, Tip Radiopacity Of 3Cm * 280-300 Cm Long , Ptca Guide Wire With Ptfe Coating Over Shaft, Polymer Sleeve Length Of 20 Cm, Tip Load Of 0.8 Gm, Tip Size Of 0.009”, Tip Radiopacity Of 16 Cm * 180-190 Cm Long , Ptca Guide Wire With Ptfe Coating Over Shaft, Polymer Sleeve Length Of 20 Cm, Tip Load Of 0.8 Gm, Tip Size Of 0.009”, Tip Radiopacity Of 16 Cm * 280-300 Cm Long , Ptca Extra-Support Guide Wire With Ptfe Coating Over Shaft, Tip Load Of 0.7 Gm, Tip Size Of 0.014”, Spring Coil Of 4 Cm And Tip Radiopacity Of 4 Cm *180-190 Cm Long , Ptca Extra-Support Guide Wire With Ptfe Coating Over Shaft, Tip Load Of 0.7 Gm, Tip Size Of 0.014”, Spring Coil Of 4 Cm And Tip Radiopacity Of 4 Cm *280-300 Cm Long , Ptca Guide Wire For Cto With Ptfe Coating Over Shaft, Tip Size Of 0.014”, Tip Radiopacity Of 11 Cm And Spring Coil Of 11 Cm, Length Of 180-190 Cm Tip Load Of * 3Gm , Ptca Guide Wire For Cto With Ptfe Coating Over Shaft, Tip Size Of 0.014”, Tip Radiopacity Of 11 Cm And Spring Coil Of 11 Cm, Length Of 180-190 Cm Tip Load Of *4.5Gm , Ptca Guide Wire For Cto With Ptfe Coating Over Shaft, Tip Size Of 0.014”, Tip Radiopacity Of 11 Cm And Spring Coil Of 11 Cm, Length Of 180-190 Cm Tip Load Of *6Gm , Ptca Guide Wire For Cto With Ptfe Coating Over Shaft, Tip Size Of 0.014”, Tip Radiopacity Of 11 Cm And Spring Coil Of 11 Cm, Length Of 180-190 Cm Tip Load Of *12Gm , Ptca Guide Wire For Cto With Extra-Support, Tip Load Of 9 Gm, Tip Size Of 0.009”, Length 180-190 Cm, With *Spring Coil And Tip Radiopacity Of 11 Cm , Ptca Guide Wire For Cto With Extra-Support, Tip Load Of 9 Gm, Tip Size Of 0.009”, Length 180-190 Cm, With * Spring Coil And Tip Radiopacity Of 20 Cm , Joint Less Spring Coil 0.014” One Piece Core Ptca Guide Wire With Tip Radiopacity 3 Cm, Length 180 Cm * Tip Load 0.7 Gm , Joint Less Spring Coil 0.014” One Piece Core Ptca Guide Wire With Tip Radiopacity 3 Cm, Length 180 Cm * Tip Load 0.5 Gm , Ptca Guide Wires, 0.014”, 180-190 Cm Long, Nitinol Distal Super Elastic Core For Kink Resistance And Shape Retention, Silicon Coating For Distal 2 Cm And Hydrophilic Coating Of Rest Of The Wire Length * Tip Load Of 1.0 Gm , Ptca Guide Wires, 0.014”, 180-190 Cm Long, Nitinol Distal Super Elastic Core For Kink Resistance And Shape Retention, Silicon Coating For Distal 2 Cm And Hydrophilic Coating Of Rest Of The Wire Length * Tip Load Of 0.6 Gm , Ptca Guide Wires, 0.014”, 180-190 Cm Long, Nitinol Distal Super Elastic Core For Kink Resistance And Shape Retention, Silicon Coating For Distal 2 Cm And Hydrophilic Coating Of Rest Of The Wire Length * Tip Load Of 3.6 Gm , Steerable Ptca Guide Wire With Floppy Tip, Elastinite Core, Soft Shaping Ribbon Tip And Hydrophilic Or Hydrophobic Coating * 180-190 Cm. , Steerable Ptca Guide Wire With Floppy Tip, Elastinite Core, Soft Shaping Ribbon Tip And Hydrophilic Or Hydrophobic Coating. * 280-300 Cm. , Steerable Ptca Extra Support Guide Wire With Durasteel Core Material, Core To Tip Design, Floppy Tip *With Hydrophobic Coating , Steerable Ptca Extra Support Guide Wire With Durasteel Core Material, Core To Tip Design, Floppy Tip *With Hydrophilic Coating , Steerable Pta High Support Guide Wire Of 0.018”, Body Ptfe/Hydrophobic Coated, Distal Hydrophilic Coating, Distal Radiopacity Of 2 Cm * 180-190 Cm Long , Steerable Pta High Support Guide Wire Of 0.018”, Body Ptfe/Hydrophobic Coated, Distal Hydrophilic Coating, Distal Radiopacity Of 2 Cm * =300 Cm Long , Ptra Guide Wire For Renal Angioplasty, Diameter 0.018”, 100- 110 Cm Long , Steerable Pta Guide Wire With Floppy Tip, Titanium Stainless Steel Alloy Core, Extra-Support Of 0.018” Diameter, =300 Cm Long. A. Tip Non-Hydrophilic B. Tip Hydrophilic , Ptca Pre-Dilatation, Monorail Balloon (Semi Compliant). Hypotube Shaft Design, Low Entry Profile (=0.017”) And 5F Guide Catheter Compatibility. Diameters (Mm): 1.2/1.25, 1.5, 2.0, 2.5, 3, 3.5, 4.0. Length: Minimum 6-8 Mm To Maximum 20 Mm Or More , Ptca Pre-Dilatation Semi-Compliant Balloon, With Push And Flex Technology, Lowest Tip Entry Profile Of =0.017”, Crossing Profile Of =0.021”, Low Profile And Marker For Better Visibility, Stepwise Transition Stiffening For More Pushability. Diameter (Mm): 1.2/1.25, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0. Length: Minimum 6-8 Mm To Maximum 20 Mm Or More , High Pressure Non-Compliant Balloon Smooth, Rounded Distal Tip And No Edge Over-Dilatation At Higher Pressure; With Least Balloon Overhang At The Edges. Diameter (Mm): 2.5, 2.75, 3.0, 3.25, 3.5, 3.75, 4, Length (Mm): Minimum 6-8Mm To =20 Mm , Ultra-Low Entry Profile Semi Compliant Balloon With .40Mm Or 0.016” And Entry Profile From 1.25*10 To 2.25*10 Remains Same For Exceptional Cross Ability Even With Higher Diameter Balloon A. Otw Over 0.018” Guidewire. B.Monorail Over 0.018” Guidewire , Peripheral Long Balloon, Hydrophobic Coating, 4F Sheath Compatible, Various Diameters Of 2-4 Mm. Length: 20 To =200 Mm, Otw Over 0.014” Guidewire. , Coronary Microcatheter With Distal Diameter Of 1.8 Fr Or Less, Proximal Diameter 2.6F, Ptfe Coated Inner Layer, And Distal Hydrophilic Coating At The Outer Layer, Flexible Tip With Outer And Inner Taper With Gold Marker At Distal Tip For Enhanced Distal Visibility To Cross Difficult Lesions * 130-135 Cm Long , Coronary Microcatheter With Distal Diameter Of 1.8 Fr Or Less, Proximal Diameter 2.6F, Ptfe Coated Inner Layer, And Distal Hydrophilic Coating At The Outer Layer, Flexible Tip With Outer And Inner Taper With Gold Marker At Distal Tip For Enhanced Distal Visibility To Cross Difficult Lesions * 150-160 Cm Long , Drug Eluting Coronary Balloon. (All Diameters And Sizes Available) A. Paclitaxel Eluting Balloon B. Sirolimus Eluting Balloon , Ivc Filter A. Temporary B. Permanent (Mri & Non Mri Compatible) , Rota Burr For Rotational Coronary Atherectomy, 1.25- 2.0 Mm. A. Burr Only. B. Burr With Advancer. C. Advancer Only , Guide Wire For Rotational Coronary Atherectomy A. Floppy. B. Extra Support , Guideliner Catheter, 6F/7F, Rapid Exchange With 145-150 Cm Working Length, Tip Radiopaque Marker , Guide Extension Catheter Other Make, 145-150 Cms Working Length , Coronary Micro-Catheter , Coronary Mother And Child Catheter , Coronary Covered Stents All Sizes , Balloon Mounted Monorail 0.014 Compatible Stainless Steel Renal Stent, All Types And Sizes , Balloon Mounted Monorail 0.014 Compatible Cobalt Chromium Renalstent, All Types And Sizes , Peripheral Stainless Steel Stent Otw/Monorail ,Balloon Mounted, All Types And Sizes , Peripheral Stainless Steel Stent, Otw/Monorail Self Expanding, All Types And Sizes , Peripheral Cobalt Chromium Stents, Otw/Monorail Self Expanding All Types And Sizes , Peripheral Cobalt Chromium Stent, Otw/Monorail, Balloon Mounted, All Types And Sizes , Peripheral Covered Stents , Nitinol Peripheral Stent, Otw/Monorail, All Types And Sizes , Peripheral Drug Eluting Balloon , Ptmc Accessories Set Complete , Spring Wire For Ptmc. , Stylet For Ptmc Balloon. , Septal Dilator For Ptmc. , Mitral Balloon All Sizes. , Mitral Balloon All Sizes. , Brokenbrough Needle Adult And Pediatric. , Mullin Sheaths Adult All Sizes. , Mullins Sheath, Paediatrics All Sizes. , Shuttle Sheaths All Sizes. , Carotid Stents All Sizes Self-Expanding/Balloon Expandable. , Filterwie For Carotid Angioplasty. , Cross Over Sheaths All Sizes. , Pulmonary Valvuloplasty Catheters. (Pediatric) , Pulmonary Valvuloplasty Catheters (Adults).All Sizes. , Aortic Valvuloplasty Catheters (Pediatric). , Aortic Valvuloplasty Catheters (Adults). , Balloons For Valvuloplasty,( Adult&Pediatric) All Sizes. , Endomyocardial Biopsy Catheters, All Sizes. , Intravasacular Retrieval Snares. , Snares With 3 Loops. , Artery Retrieval Snares. , Micro Vena Snares. , Destination Sheath For Carotids. All Sizes. , Pda Coils All Sizes. , Pda Closure Devices All Types And Sizes. (Quote Separately) , Asd Closure Devices All Types And Sizes. (Quote Separately) , Vsd Closure Devices All Types And Sizes. (Quote Separately) , Delivery System For Asd, Complete Set. , Delivery System For Vsd, Complete Set. , Delivery System For Pda, Complete Set. , Vasacular Plugs All Types And Sizes. , Cp Stent All Sizes. , Bib Stent For Coarctation. , Covered Stent For Coarctation. , Pva Particles All Sizes. , Micro Coils For Avm. , Cyanoacrylate Glue. , Microcatheter For Uterine Artery Embolization. , Ffr Wire Which Should Be Hydrophilic And With A Tip Load 0.6G. Should Be Usfda Approved. , Oct Catheter For Advanced, High Resolution Imaging. Its Tip Should Be Low Profile (2.7F), And Catheter Should Be Compatible With Standard 0.014 Guide Wires , Ivus Catheter With Single Rotating/Mechanical Transducer Driven By A Flexible Drive Cable With Minimum 20 Mhz Frequency. , Embolectomy Catheter 2 × 2 For Bas. , Non Ionic Iodine Contrast Iohexol 300 Mg X50 Ml Pack , Non Ionic Iodine Contrast Iohexol 300 Mg X100 Ml Pack , Non Ionic Iodine Contrast Iohexol 350 Mg X50 Ml Pack , Non Ionic Iodine Contrast Iohexol 350 Mg X100 Ml Pack , Iodixanol 320 Mg Iodine Per Ml. X 50 Ml Pack , Iodixanol 320 Mg Iodine Per Ml. X100 Ml Pack , Iomeperol 400Mg Iodine Per Ml. X 100 Ml Pack , Iobitridol 370Mg Iodine Per Ml X 100 Ml , Iopromide 300Mg Iodine Per Ml. 50 Ml Pack , Iopromide370 Mg Iodine Per Ml. 50 Ml Pack , Iopromide 300Mg Iodine Per Ml. 100 Ml Pack , Iopromide 370Mg Iodine Per Ml. 100 Ml Pack , Renal Denervation Therapy - Spiral Multi Electrode Renal Denervation Catheter Essential Features: A. The Catheter Should Be Able To Provide Plug And Play Design With A Uniform Sizing That Fits The Anatomy Of The Renal Artery, Accessory And Brand Vessels In The Diameter Of 3-8Mm. B. It Should Be Having A Multi-Electrode System That Covers The 4 Quadrants Simultaneously For A Circumferential Ablation Giving Complete Denervation As The Result. C. Rapid Exchange Design Compatible With 0.014” Guidewire. D. Guidewire Retraction Used To Deploy The Spiral Electrode Array. E. Rx Joint: 30Cm From Distal Tip. F. Vessel Diameter Treatment Range 3-8Mm. G. Four Independently Controlled Rf Monopolar Gold Electrodes Spaced 6.5Mm Apart (Distal Self-Expanding Array Of 4 Electrodes, Which Is Made Of Gold, Radio-Opaque And 1.5Mm In Length). H. Treatment Length 17-21Mm If All Electrodes Are Activated. I.Tip Length 5Mm J. Tip Marker: 1Mm Proximal Of Distal Tip (Platinum/ Iridium Alloy As Tip Marker) K. Femoral Shaft Marker 55Cm From Distal Tip L. Sterilization Process: E-Beam And 10-6Sal M. Shelf Life: Three Years. , Endovascular Repair Of Thoracic And Abdominal Aortic Aneurysm(Evar/Tevar) Stent Graft Of All Size: 18-32Mm Diameter) Infra Renal Neck Length (Minimum – 15Mm) Material – Ptfe/Polyester Trifurcated Or Aorto – Unilliac Configuration , Trans Catheter Aortic Valve Replacement (Tavr) - Self Expanding Valve (Sev) - Balloon Expendable Valve (Bev) Specification Of Evolut Fx Self-Expanding, Recapturable Supra-Annular Porcine Pericardium Aortic Tavr Valve With An External Skirt And 3Mm Depth Markers, Delivered Through A Single-Spine Catheter, Designed To Treat Annulus Ranging From 17 To 30Mm. Evolut Fx 23-34 Evolut Pro Plus Self-Expanding, Recapturable Supra-Annular Porcine Pericardium Aortic Tavr Valve With An External Skirt Designed To Treat Annulus Ranging From 17 To 30Mm. Evolut Pro+ 23-34