Improvement Estimate for low voltage -conversion Kalingarajapuram Their SS-100K under Namboly section, 2)Improvement estimate for Low voltage – conversion of Thoothoor Engine SS-100KVA under Namboly section, 3)Improvement estimate for replacement of 5 nos HT/LT PSC 9 mtr cored and Improvement estimate for replacement of 1 no 63 KVA Low voltage DT under Puthukadai section, 4)Replacement of deteriorated structure materials at Edappadu Puthuvazhvudyanaillam 100KVA DT under Namboly section, 5)Replacement of deteriorated 2 nos RCC structure pole and structure materials of location Poothurai post office SS/100KVA under Namboly section, 6)Replacement of deteriorated structure materials at Nursing college SS 100KVA under Karungal section, 7)Replacement of 1 no deteriorated structure materials at AzhithuraiSS I 100KVA in 11KV Thengapattanam feeder under Killiyoor section, 8)Revised estimate for replacement of MS structure materials to GI structure materials in Uthukuzhi SS 100KVA under Puthukadai section, 9)Replacement of MS structure materials to GI structure materials and 2 nos 9m PSC pole in Bharathiyar SS 1 100KVA under Killiyoor section, 10)Replacement of MS structure materials to GI structure materials and 2 nos 9m PSC pole in STD SS2 100KVA under Killiyoor section, 11)Replacement of deteriorated structure materials at PoothuraiKarunniyapuram 100 KVA DTunder Namboly Section, 12)Replacementof 2 nos deteriorated RCC 9.14 mtr poles locs no :61, in Kozhivilai feeder and 16 in 11KV Oorambu feeder under Sooriacode section, 13)Replacement of deteriorated 2nosRCC structure pole and structure materials of location St.Jud’s Colony SS/100KVA in 11KV Poothurai feeder under Namboly section, 14)Replacement of deteriorated2 nos RCC structure poles and structure materials of locationKaruniyapuram School SS/100KVA in Poothurai feeder under Namboly section, 15)Replacement of deteriorated 2 nos RCC structure pole and structure materials of location Kalingarajapuram SSIII/100KVA in 11KV Nithiravilai feeder under Namboly section, 16)Replacement of 2 nos deteriorated RCC structure pole and structure materials in Mekadu VLC SS 100KVA under Sooriyacode section, 17)Replacement of 2 nos deteriorated RCC structure pole and structure materials Vadalikonam SS 100KVA under Sooriyacode section, 18)Replacement of 1 no deteriorated structure materials with poles at Barathiyar Street SS II 100KVA Thengapattanam feeder under Killiyoor section, 19)Replacement of 1 no deteriorated structure materials at STD SS I 100KVA Thengapattanam feeder under Killiyoor section, 20)Replacement ofdeteriorated 2nos structure pole and structure materials of location Edappadu SSV/100KVA under Namboly section, 21)Improvement estimate for MS structure materials to GI materials in Aathupalli SS under Puthukadai section, 22)Replacement of dereriorated structure materials at Thoothoor-E SS 100KVA under Namboly distribution section,23)Provision of by providing 1 no double pole 11KV AB switch at Tharathattu area in 11KV Nattalam feeder under Karungal Section, 24)Provision of by providing 1 no double pole 11 KV AB switch at Oolavilai area in 11KV Kattuvilai feeder under Karungal section, 25)Replacement of 2nos deteriorated 9mtr PSC pole various location Police station SS 500KVA FII/2 and9 under Karungal section, 26)Replacement of 3nos deteriorated PSC 9mtr poles loc no NTM/44,45 and 46 in 11 KV Nattalam feeder under Palliyadi section, 27)Replacement of 4 nos deteriorated PSC 9mtr poles loc no :NTM/9,12,14 AND 19 in 11KV Nattalam feeder under palliyadi section, 28)Improvement estimate for shifting of 1 no 40feet RSJ pole road at location F1/1 in Methukummal NH SS 100KVA under Sooriyacode section, 29)Replacement of 4nos deteriorated RCC 9.14 mtr poles loc no 54,55,56 and 58 in Kozhivilai feeder under Sooriyacode section, 30)Replacement of 4nos deteriorated PSC 9mtr poles locs no:NTM/22, 28, 40, 42 in 11KV Nattalam feeder under Palliyadi section, 31)Estimate for over load at Kanjikuzhi area of Kanjikuzhi SS II/100KVA by providing 1 no additional 63KVA DT under Palliyadi setion, 32) Estimate for replacing detoriated MS DT structure materials into new structure with GI structure materials at Bharathiyar St.SS I under Killiyoor section, 33)Improvement estimate for Low voltage area in vattakottai SS II 100 KVA by providing 2Nos songle pole structure 25 KVA New DT under Killiyoor section, 34)Improvement est for bifurcation of load in 11KV Kollencode feeder and 11KV Thengapattanam feeder of 110/11KV SS Munchirai under Puthukadai Section, 35)Estimate for replacement of corroded LT MS line materials into LT GI line Materials at Kaithavilagam SS 100KVA in feeders F1&F2 of coastal areas under Karungal section, 36)Improvement estimate for replacement of corroded AAAC 7/3.15, 7/2.59 and ACSR 7/2.59sq mm conductor at Kaithavilagam SS /100KVA under Karungal section, 37)Improvement est for Low voltage DT in Maniyarankuntu SS I 100KVA by providing 1 no single pole structure 63 KVA New DT in Orupilavilai under PKD section, 38)Improvement est for over load DT in Thoppu School SS 100KVA by providing 1 no single pole structure 63 KVA New DT in Thoppu School SS II under PKD Section, 39)Estimate for avoiding overload at Kakavilai area of Kaithavilagam SS1/25 KVA by providing 1 no additional 11KV/433/25KVA DT under Karungal Section, 40)Proposal for improving low voltage at Thomas Nagar area of Manal Hospital SS 100KVA by providing 1 no additional 63KVA DT under Namboly section, 41)Eos to 1 No PAL Service Connection to M/s wireless info service limited by providing 1 no Additional DT 63 KVA under Palliyadi section, 42)Proposalforimproving low voltage at Kidarakuzhi area of Valiyavilai SS/100KVA by providing 1 no additional 63KVA DT under Namboly section, 43)Proposal for improving low voltage at Kalingarajapuram area of Kalingarajapuram Their SS/100KVA by providing 1 no additional 63KVA DT under Namboly section, 44)Estimate for over load at Puthucode SS 100KVA by providing 1 no additional 11KV /433V/63KVA DT under Sooriyacode section, 45)Estimate for overload at Paruthikattuvilai area of Punkarai Arch SS by providing 1 no additional 63KVA DT under Palliyadi section, 46)Proposal for improving low voltage at Kulinjavilai area of south Mullucode SS by providing 1 no additional 25 KVA DT under Sooriyacode section, 47)Proposal for improving low voltage at Pootakulam Chappathu area of Vavarai School providing 1 no additional 25 KVA DT under Sooriyacode section, 48)Proposal for improving low voltage at ThekkumuriPottakulam area of Thekkumuri SS by providing 1 no additional 25KVA DT under Sooriyacode section, 49)Proposal for improving low voltage at ThekkumuriKonam area of Thekkumuri SS by providing 1 no additional 25 KVA DT under Sooriyacode section, 50) Improvement estimate for tail end low voltage complaint Makkaludan Muthalvar camp Nadaikkavu dt:06.08.2024 at Fathimanagar Church SS 100KVA by providing ADL1 no 25 KVA Single pole DT at Vadakaravilai under SooriacodeSection in KanyakumariElectricityDistribution Circle.- 1 Loading & unloading charges of all RCC ,REC pole above 8.0 Mts length 2 Transporting charges of all type of pole and other associated materials from Road side to pole pit and vice versa up to 2 KM (Above 8m pole) 3 Excavation of pole pitin Rocky area (cmmon to all size of poles) by blasting / Manual 4 Erection of RCC,REC,PSC pole above 8.0 Mts length by using Crane/manual 5 Loading & unloading charges of all RCC ,REC pole upto 8.0 Mts length 6 Transporting charges of all type of pole and other associated materials from Road side to pole pit and vice versa up to 2 KM (Up to 8m pole) 7 Excavation of pole pit upto 8.0 mts length by using JCB/Manual 8 Erection of RCC,REC,PSC pole upto 8.0 Mts length by using Crane/manual 9 Fixing of 3Q X arm 10 Fixing of SQ X arm 11 Fixing of VX arm 3 .5 feet 12 Fixing of Taping Channel X Arm 13 Fixing of HT/LT TI Fittings 14 Dismantling & Re-Erection of 3Q Xarm 15 Dismantling & Re-Erection of SQ X arm 16 Dismantling & Re-Erection of V Xarm 17 Dismantling & Re-Erection ofTaping Channel X Arm 18 Dismantling & Re Fixing of HT/LT TI Fittings 19 Fixing of HT Pin Insulater 20 Fixing of LT Pin Insulater 21 Fixing of HT Disc Insulater 22 Fixing of Lt shackle 23 Fixing of Aluminium knob 24 Dismantling & Re Fixing of HT Pin Insulater 25 Dismantling & Re Fixing of LT Pin Insulater 26 Dismantling & Re Fixing of HT Disc Insulater 27 Dismantling & Re Fixing of Lt shackle 28 Dismantling & Re Fixing of Aluminium knob 29 Dis & Redoing of S phase connection 30 Dis & Redoing of 3 phase connection 31 Dismantiling Re-Erection of 1*40 W tube light cmplete set 32 Street light switching point arrangement 33 Dismantling & Re-Erection of street lightswitching point arrangement 34 Excavation of stay pit of 4.5 depth 35 Erection of stay setcomplete 36 Erection of stay setcomplete in the rocky area by blasting 37 Dismantling and re Erection of stay setcomplete 38 Dismantling & Re Erection of stay setcompleteof stay pit of 4.5 depth (50% of original erection charges) 39 Paving & Stringing of conductor 7/4.09 mm ACSR 40 Paving & Stringing of conductor of above 7/2.59mm ACSR up to 7/3.35 mm ACSR 41 Paving & Stringing of conductor up to 7/2.59mm ACSR or other equivalent conductor 42 Dismantling &Re Stringing of conductor 7/4.09 mm ACSR 43 Dismantling & Re erection of conductor of above 7/2.59mm ACSR up to 7/3.35 mm ACSR 44 Dismantling & Re erection of conductor up to 7/2.59mm ACSR or other equivalent conductor 45 Dismantling & Re erection of split newtral gaurding 46 Dismantling of Structure set complete including Bed Channel, Belting Angle, AB switch,H.G. Fuse, Feeder arrangements with open type fuse unit for 2 feeders,HT-LAS ,LT-LAS ,HT jumpering complete, LT Bus arrangement, insulator angle and erection of 3 Nos. Pin insulator, Danger board, Structure earthing complete with 3 pits and earth loops & 63KVA Distribution Transformer & RCC, REC, PSC & METAL POLE OF ALL SIZES including the closing of pit(Grill Seperation) 47 Erection of 11 KV single pole Structere including erection of DT complete without center support 48 Erection of 11 KV single pole Structere including erection of DT complete with center support 49 Erection of Dis Tr Str complete as per TNEB standard including painting,Feeders arrangement,colour washing of RCC poles etc… fixing of HT/LT lASand Jumbering 3 nos Earth pit with earth except Distn Transformer 50 Erection of Dis Tr Str complete as per TNEB standard including painting,Feeders arrangement,colour washing of RCC poles etc… fixing of HT/LT lASand Jumbering 3 nos Earth pit with earth except Distn Transformer and expect 2 nos pole erection 51 Dismantling of Structure set complete including Bed Channel, Belting Angle, AB switch,H.G. Fuse, Feeder arrangements with open type fuse unit for 2 feeders,HT-LAS ,LT-LAS ,HT jumpering complete, LT Bus arrangement, insulator angle and erection of 3 Nos. Pin insulator, Danger board, Structure earthing complete with 3 pits and earth loops & 63KVA Distribution Transformer & RCC, REC, PSC &ALL SIZES of pole 52 Loading & un loading of Distribution Transformer up to 25 KVA 53 Transporting of Distribution Transformer up to 25 KVA 54 Erection of Distribution Transformer Above 25 KVA to 100KVA 55 Loadind & un loading of Distribution Transformer Above 25 KVA to 100KVA 56 Transporting of Distribution Transformer Above 25 KVA to 100KVA 57 Dismantling and re-Erection of Distribution Transformer Above 25 KVA to 100KVA 58 Erection of DP structure with stay asper TNEB std including fixing of Top channel,crossbracing, concreting, painting,colour washing etc with11 KV ABS using all type of poles 59 Set right of all sizes of leaning pole 60 Loading & unloading ofline materials 61 Transporting of distn transformer/ line materials from store to office /site up to 10 km distance by enqaging 62 Drilling / Less than 23mm holes per hole / Slatted holes of slotted holes 63 Ordinary TreeClearance 64 Coconut TreeClearance