}

Imp Estimate For Shifting Of 1No 8Mtr Rcc Pole As Per The Request Of The Public, Mekkottukonam Under Puthenchanthai Section. 2)Improvement Estimate For Shifting Of 1No 8Mtr Psc Pole As Per The Request Of Thiru.Maniyan, Kizhakkethottam, Under Puthenchantha, Kanniyakumari-Tamil Nadu

Tamil Nadu Generation And Distribution Corporation Limited has published Imp Estimate For Shifting Of 1No 8Mtr Rcc Pole As Per The Request Of The Public, Mekkottukonam Under Puthenchanthai Section. 2)Improvement Estimate For Shifting Of 1No 8Mtr Psc Pole As Per The Request Of Thiru.Maniyan, Kizhakkethottam, Under Puthenchantha. Submission Date for this Tender is 24-04-2025. Overhead Line Tenders in Kanniyakumari Tamil Nadu. Bidders can get complete Tender details and download the document.




Tender Notice

48639196
Imp Estimate For Shifting Of 1No 8Mtr Rcc Pole As Per The Request Of The Public, Mekkottukonam Under Puthenchanthai Section. 2)Improvement Estimate For Shifting Of 1No 8Mtr Psc Pole As Per The Request Of Thiru.Maniyan, Kizhakkethottam, Under Puthenchantha
Open Tender
Indian
Tamil Nadu
Kanniyakumari
24-04-2025

Tender Details

Imp estimate for shifting of 1no 8mtr RCC pole as per the request of The Public, Mekkottukonam under Puthenchanthai Section. 2)Improvement estimate for shifting of 1no 8mtr PSC Pole as per the request of Thiru.Maniyan, Kizhakkethottam, under Puthenchanthai section. 3)Estimate for replacement of HT/LT line 1 no 8m PSC into 9m PSC pole for line clearance at location F1/10 in Exchange SS/100KVA under Puthenchanthai section. 4)Estimate for replacement ot H I /LT line 1no 8m PSC pole for line clearance at location FI/1 in MPM Market SS1/63KVA under Puthenchanthaisection. 5)Elecy. replacement of HT/LT line 2nos changing 8mtr pole into 9mPSC pole for ground clearanceunder Puthenchanthai Section. 6)Estimate for improving the low voltage at Panankalaivilai area of Vavaraivilai SS 63KVA by transfer the load to Kurumadathukulam SS 63KVA under Puthenchanthai section. 7)Estimate for replacement of aged conductor deteriorated pole and strengthening of conductor in LT line ACSR 7/2.59 and 7/2.11 change to AAAC 7/3.15 as per request of Thiru.S.G.Sajayakumar at Parayadivilai under Puthenchanthai Section. 8)Replacement of 1no deteriorated 9mtr PSC pole at loc FI/9 in Kuzhijanvilai SS 100 KVA under Puthenchanthai Section. 9)Replacement of 1no deteriorated 9.14mtr RCC pole at loc FII/2 in Malamari SS I 100 KVA under Puthenchanthai Section. 10)Insertion of 1no 8mtr PSC pole at loc FI/3-4 in Mulluvilai SS 100KVA under Puthenchanthai section. 11)Insertion of 1no 8mtr PSC pole at loc FI/16-17 in Mullacheri SS I 250 KVA under Puthenchanthai section. 12)Replacement of 1no deteriorated 9.14mtr RCC pole at loc FI/1 in Rakulam SS 100 KVA under Puthenchanthai Section. 13)Replacement of 3nos deteriorated 8 mtr PSC pole at various location no Fl/34, Fl/40 and F2/18 in VHSS 250KVA under Puthenchanthai section. 14)Replacement of 1nos deteriorated 8 mtr PSC pole at various location no Fl/4 in KannapuramSS II 100 KVA under Puthenchanthai section. 15)Insertion of 1no 8mtr PSC pole at loc FI/9-10 in Kuzhijanvilai SS I 100 KVA under Puthenchanthai distribution section. 16)Replacement of 1nos deteriorated 8 mtr RCC pole at location no Fl/14 in Elluvilai SS 100 KVA under Puthenchanthai section. 17)Replacement of 1nos deteriorated 8 mtr PSC pole atlocation no Fl/93 in Perumpila SS 63 KVA under Puthenchanthai section. 18)Insertion of 1no 8mtr PSC pole at loc FII/19 to 20 in VH SS 250 KVA under Puthenchanthai section. 19)Replacement of 2 nos deteriorated 8 mtr RCC pole at location no FlI/36&54 in Puthuvettukonam SS II 100 KVA under Puthenchanthai section. 20)Replacement of 1nos deteriorated 8 mtr PSC pole atlocation no Fl/15 in PTC SS II 63 KVA under Puthenchanthai section. 21)Natural Calamity estimate for replacement of 1no 8mtr PSC pole at loc no:FI/17 of Kudukkachivilai SS 100 KVA damaged due to fallen of rubber tree over LT line under Puthanchanthai Section. 22)Natural Calamity estimate for replacement of 1no 8mtr PSC pole at loc no:FII/31 of VH SS 250 KVA damaged due to fallen of rubber tree over LT line under Puthanchanthai Section. 23)Natural Calamity estimate for replacement of 1no 8mtr PSC pole at loc no:FI/7 of Ambatinkalai SS 63 KVA damaged due to fallen of Ayani tree over LT line under Puthanchanthai Section. 24)Natural Calamity estimate for replacement of 1no 8mtr PSC pole at loc no:FII/9 of Puthenchanthai SS 100 KVA damaged due to fallen of coconut tree over LT line under Puthanchanthai Section. 25)Natural Calamity estimate for replacement of 2 nos 8mtr PSC pole at loc no:FII/13,18 of Pilavilai SS 100 KVA damaged due to fallen of rubber tree over LT line under Puthanchanthai Section. 26)Natural Calamity estimate for replacement of 1 nos 8mtr PSC pole at loc no:FII/28 of Kanjiyodu SS 63 KVA damaged due to fallen of rubber tree over LT line under Puthanchanthai Section. 27)Natural Calamity estimate for replacement of 1 nos 8mtr PSC pole at loc no:FI/9 of VH SS 250 KVA damaged due to fallen of tree over LT line under Puthanchanthai Section. 28)Natural Calamity estimate for replacement of 1 nos 8mtr PSC pole at loc no:FI/7 of Pakode SS II 63 KVA damaged due to fallen of tree over LT line under Puthanchanthai Section. 29)Natural Calamity estimate for replacement of 1 nos 9.14mtr RCC pole at loc no:FII/3 of Kallupalam SS 63 KVA damaged due to fallen of tree over HT/LT line under Puthanchanthai Section. 30)Maintenance estimate for the 11 KV line Tree clearance work from Malapuram ABS to Malamari ABS of 11 KV Mukkuttukadal feeder under Puthenchanthai Section in KanyakumariElectricityDistribution Circle.- 1 Loading&unloading of all REC, RCC pole above 8 m length 2 Excavation of pole pits for pole above 8 m length by using JCB/Manual 3 Erection of RCC,REC,PSC poles above 8 m length by using crane or manual 4 Loading&unloading of all REC, RCC pole upto8 m length 5 Excavation of pole pits for pole upto 8 m length by using JCB/Manual 6 Erection of RCC,REC,PSC poles upto 8 m length by using crane or manual 7 Transportation of all types and sizes of poles and other associated materials from road side to pole pit and vice versa upto 0.50KM 8 Fixing of LT S phase cross arm 9 Fixing of LT 3 phase cross arm 10 Fixing of LT pin insulator 11 Fixing of shackle 12 Fixing of aluminium knob 13 Excavation of stay pit of 4.5 to 5 depth using JCB/Manual 14 Erection of stay set complete with fixing up stay wire Eye, Bow, Guy shackle, Binding etc 15 Paving and stringing of conductors of sizes upto 7/2.59 mm ACSR or equivalent conductor 16 Paving and stringing of conductors of above 7/2.59 mm ACSR or other equivalent conductor upto 7/3.35 mm ACSR or other equivalent conductor. 17 Paving and stringing od conductors of 7/4.09mm ACSR or other equivalent conductor 18 Earthing of poles with GI wires 4 or 6 SWG by coil earthing 19 Loading&unloading of line materials 20 Transporting of Distribution Transformer/Line materials from stores to office/ site up to 10 Km distance by engaging 1 Ton capacity Minidor(Lorry) 21 Drilling/less than 23mm hole per hole/slatted hole 22 Coconut Tree clearance 23 Ordinary tree clearance 24 Dismantling & re erctionof Single phase Service connection 25 Dismantling & re erctionof Three phase Service connection 26 Dismantling & reerction of V X arm 27 Dismantling & reerction of HT/LT TI fittings 28 Dismantling & reerction of HT pin insulator 29 Dismantling & reerction of LT S phase cross arm 30 Dismantling & reerction of LT 3 phase cross arm 31 Dismantling & reerection of LT pin insulator 32 Dismantling & reerection of LT Shackle 33 Dismantling&reerection of aluminium knob 34 Dismantling&reerction of conductors of sizes upto 7/2.59 mm ACSR or equivalent conductor 35 Dismantling& Reerection conductors of above 7/2.59 mm ACSR or other equivalent conductor upto 7/3.35 mm ACSR or other equivalent conductor. 36 Dismantling&reerction of conductors of 7/4.09mm ACSR or other equivalent conductor 37 Dismantling of stay set complete with fixing up stay wire Eye, Bow, Guy shackle, Binding etc 38 Dismantling of 9mtr RCC,REC, PSC &metal pole including the closing of the pit 39 Dismantling of 8mtr RCC,REC, PSC &metal pole including the closing of the pit 40 Dismantling of conductors of sizes upto 7/2.11&7/2.59 mm ACSR or equivalent conductor

Key Value

Document Fees
Refer document
EMD
INR 3360.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail