Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | YATRIHALL ( G+1) |
| 2 | Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. |
| 3 | Filling of carted earth. |
| 4 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. |
| 5 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. |
| 6 | Providing and injecting chemical emulsion for pre constructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete. |
| 7 | (plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm |
| 8 | (4) Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer\"s standard dilution) |
| 9 | R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. The rate excludes making of drip course which shall be paid extra. [IN LINTEL] |
| 10 | R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. The rate excludes making of drip course which shall be paid extra. [IN BEAM] |
| 11 | R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. The rate excludes making of drip course which shall be paid extra. [IN SLAB] |
| 12 | R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. The rate excludes making of drip course which shall be paid extra. [IN COLUMN] |
| 13 | R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. The rate excludes making of drip course which shall be paid extra. [IN FOOTING] |
| 14 | M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 15 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) |
| 16 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
| 17 | Same as in item No. 11 abovebutin super-structure above plinth level up to floor two level ( up to two storeys ) includingnecessarycutting and moulding of brick work asrequiredand also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement : coarse sand) |
| 18 | Ground Floor |
| 19 | First Floor |
| 20 | Same as in item no. 14 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. |
| 21 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Mild steel and Medium Tensile steel bars |
| 22 | 15mm thick plaster with cement mortar in proportion of 1:4 cement & coarse sand of 2.25 F.M. |
| 23 | 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 fine sand |
| 24 | Ground Floor |
| 25 | First Floor |
| 26 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 finesand. |
| 27 | Ground Floor |
| 28 | First Floor |
| 29 | Making grooves 10 to 12 X 12mm and upto 25 X 15 mm deep in plaster of the walls or in ceiling vertically or horizontally as required. |
| 30 | Supply & fixing 6mm China white glazed tiles in flooring or in skirting or dado laid with 1:3 Cement and approved coarse sand mortar finished with whitecement slurry, jointing and polishing complete, including supply of all materials, labour and Tool & plants. |
| 31 | Supply & fixing 6mm China white glazed tiles in flooring or in skirting or dado laid with 1:3 Cement and approved coarse sand mortar finished with whitecement slurry, jointing and polishing complete, including supply of all materials, labour and Tool & plants. |
| 32 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x1200 mm (Flooring) |
| 33 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x1200 mm (Skirting) |
| 34 | Providing and fixing 18 mm thick (Granite) gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm [IN FLOORING] |
| 35 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Ordinary cement without any pigment |
| 36 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). |
| 37 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 38 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Second class teak wood |
| 39 | Providing and fixing factory made uPVC white colour sliding glazed door comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension uPVC extruded glazing beads, uPVC extruded interlock and uPVC extruded Inline sash adaptor (if required), EPDM gasket, wool pile, zinc alloy (white powder coated) handle with key on one side of extreme panels along with zinc plated mild steel multi point locking having transmission gear with keeps, zinc alloy (white powder coated) cresent lock (if required), stainless steel (SS 304 grade) body with adjustable doublenylon rollers (weight bearing capacity to be 120 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. |
| 40 | Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware\"s anddrainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 41 | Three track three panels sliding door with fly proof S.S wire mesh (Two nos. glazed & one no. wire mesh panels) made of (big series) frame 116 x 45 mm & sash 46 x 82 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door above 2.00 sqm upto 5.00 sqm) |
| 42 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For Internal wall surface) |
| 43 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 44 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (Ceiling) |
| 45 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 46 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. |
| 47 | Providing & fixingAluminiumsliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 300mm x 16mm. |
| 48 | Providing and fixingAluminium. anodised towerbolts (barrel type) with necessary screws etc. complete. |
| 49 | (a) 250 mm x 10mm |
| 50 | Providing and fixing S.S anodised handles with screws etc. complete (a) 125 mm. |
| 51 | Providing & laying \"brick coba\" 12 mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15 mm to each other, over 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with aerelic cement concrete water water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth & top mashed false square 30cm x cm and side wall parapet shall be mono tythic plaster wall upto 30 cm higher and junction |
| 52 | and corner shall be rounded by brick ballast cement and coarse sand masonary coba with top finished plaster mixed with acelic water proofing compound @ 2% by weight & including S/o all material, labour, T & P etc complete for proper completion of work. |
| 53 | Painting with synthetic enamel paint of approved brand and manufacture of required colourto give an even shade : |
| 54 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 55 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 56 | Construction of drain alongwith apron. |
| 57 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. |
| 58 | Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc.p |
| 59 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 60 | (a) Foundations, footings, bases of columns, etc. for mass concrete |
| 61 | (b) Suspended floors, roofs, landings, balconies and access platform |
| 62 | (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 63 | (d) Columns, Pillars, Piers, Abutments, Posts and Struts |
| 64 | Providingandfixingtiledfalseceilingofspecifiedmaterialsofsize 595x595mmintruehorizontallevel,suspendedoninterlockingmetalgrid ofhotdippedgalvanizedsteelsections(galvanized@120grams/sqm, bothsideinclusive)consistingofmain“T”runnerwithsuitablyspaced jointstogetrequiredlengthandofsize24x38mm madefrom0.30mm thick(minimum)sheet,spacedat1200mmcentertocenterandcross “T”ofsize24x25mmmadeof0.30mmthick(minimum)sheet,1200 mmlongspacedbetweenmain“T”at600mmcentertocentertoform agridof1200x600mmandsecondarycross“T”oflength600mmand size24x25mmmadeof0.30mmthick(minimum)sheettobeinterlocked atmiddleofthe1200x600mmpaneltoformgridsof600x600mmand wallangleofsize24x24x0.3mmand layingfalseceilingtilesofapproved textureinthegridincluding,requiredcutting/making, openingforservices likediffusers,grills,lightfittings,fixtures,smokedetectorsetc. |
| 65 | Main“T” runnerstobesuspendedfromceilingusingGIslottedcleatsofsize27x 37x25x1.6mmfixedtoceilingwith12.5mmdiaand50mmlongdash fasteners,4mmGIadjustablerodswithgalvanisedbutterflylevelclipsof size85x30x0.8mmspacedat1200mmcentertocenteralongmainT, bottomexposedwidthof24mmofallT-sectionsshallbepre-paintedwith polyesterpaint,allcompleteforallheightsasperspecifications,drawings andasdirectedbyEngineer-in-charge. |
| 66 | 12.5mmthicksquareedgePVCLaminatedGypsum Tileofsize595x595mm,madeofGypsumplasterboard, manufacturedfromnaturalgypsumasperIS2095part|and laminatedwithwhite0.16mmthickfireretardantPVCfilm onthefacesideand12micronmetalizedpolyesteronthe backsidewithalledgessealedwiththefacesidePVCfilm whichgoesaroundandwrapstheedgesandisbondedto theedgesandthebacksidemetalizedpolyesterfilmsoasto makethetileacompletelysealedunit. |
| 67 | Internal Electrification (Yatri Hall) |
| 68 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 69 | Group C |
| 70 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 71 | Submains : |
| 72 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 73 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 74 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 75 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 76 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 77 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 78 | 20 mm |
| 79 | 25 mm |
| 80 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 81 | 5/6 A switch |
| 82 | 3 pin 5/6 A socket outlet |
| 83 | TV antenna socket outlet |
| 84 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 85 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 86 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 87 | 1 or 2 Module (75mmX75mm) |
| 88 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 89 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 90 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 91 | Upto 450 mm sweep |
| 92 | MCB\"s & DB’s : |
| 93 | Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 94 | 4 way (4 + 12), Double door |
| 95 | 6 way (4 + 18), Double door |
| 96 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 97 | 4 way (4 + 12), Double door |
| 98 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 99 | Single pole |
| 100 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 101 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 102 | 100 A,30KA,FPMCCB |
| 103 | Supply and fixing of 40 Amp. TP MCB (10 KA) C Curve. CAT A |
| 104 | Supply and fixing of 63 Amp. TP MCB (10 KA) C Curve. CAT A |
| 105 | Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A |
| 106 | Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A |
| 107 | ELCB/RCCB Switches : |
| 108 | Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 109 | 40 A |
| 110 | 63 A |
| 111 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 112 | Earthing Work : |
| 113 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 114 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 115 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 116 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, inconvenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 117 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 118 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 119 | Lighting Fixtures (Lights/Fans) : |
| 120 | Supply and fixing of Single light Wall Bracketon matching M.D.F.E.G. Board base etc.Complete in all respect. CAT. - AAA |
| 121 | Supply and fixing of LED Tube Light fitting suitable for up to 1X22 Watt LED Tube Light on surface complete in all Respect . |
| 122 | Supply & fixing of recess mounting round 10 to 15 watt LED down Lighter complete in all respect. |
| 123 | Supply & fixing of recess mounting round 15 to 18 watt LED down Lighter complete in all respect. |
| 124 | Armoured Cables (Cable/Gland/Lug) : |
| 125 | Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size |
| 126 | size 25 sq mm x 3-1/2core |
| 127 | size 35 sq mm x 3-1/2core |
| 128 | Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer-incharge. for cable |
| 129 | size 25 sq mm x 3-1/2core |
| 130 | size 35 sq mm x 3-1/2core |
| 131 | Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable |
| 132 | size 25 sq mm |
| 133 | size 35 sq mm |
| 134 | L.T. Switch Panel Board : |
| 135 | Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCB\"s (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects. |
| 136 | The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. |
| 137 | The MCCB\"s shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle Type |
| 138 | Incoming - |
| 139 | 200 Amp MCCB-1 No. |
| 140 | Outgoing - |
| 141 | 100 Amp 4P MCCB - 2 Nos. (for VTPN D.B. DB\"s) |
| 142 | 100 Amp 4P MCCB - 2 Nos. (for VTPN D.B. DB\"s) |
| 143 | 63 Amp 4P MCCB - 1 Nos. (for Terrace pump)) |
| 144 | 40 Amp DP MCB - 2 Nos. (Spare) |
| 145 | (or As per requirment directed by Project Manager.) |
| 146 | Non-Schedule Items |
| 147 | S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. |
| 148 | Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. |
| 149 | INTERNAL SANITARY (Yatri Hall) |
| 150 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required |
| 151 | W.C. pan with ISI marked white plastic seat and lid |
| 152 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: |
| 153 | White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap. |
| 154 | Providing and fixing wash basin with C.I. brackets, 15 mm dia C.P. brass Single Hole Basin Mixture approved quality and make ,including painting of fittings and brackets, cutting and making good the walls wherever require. |
| 155 | a)White Vitreous China wash basin size 550x 400 mm with 15 mm dia C.P. brass Single Hole Basin Mixture. |
| 156 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. |
| 157 | Semi rigid pipe |
| 158 | a) 32mm dia |
| 159 | b) 40mm dia |
| 160 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 161 | Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate for Eureopean type W.C. of quality and make as approved by engineer-in-charge. |
| 162 | 15mm nominal bore |
| 163 | Providing and fixing CP Brass 32 mm sizeBottal Trap of approved quality & make and as per thedirection of Enginer-in-charge. |
| 164 | Providing and fixing CP Brass Single lever lelephonic wall mixture of quality & make and as per thedirection of Enginer-in-charge. |
| 165 | a) 15mm dia nominal dia. |
| 166 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet |
| 167 | a) 100 mm diameter |
| 168 | Providing and fixing Toilet paper holder |
| 169 | a) C.P. brass |
| 170 | Providing & fixing 600x120x5 mm glass self with edges round off, supported on anodiesd aluminium angle framewith C.P. brass bracket and guard rail complete fixed with 40 mmlong screws, rawl plugs etc, complete. |
| 171 | Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms. |
| 172 | Providing & fixing PTMT towl rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm. long towl rail length of 645 mm. width 78 mm. and effective height of 88 mm, weighing not less than 190 gms. |
| 173 | Providing & fixing 32 # G.I. Pipes spout including cutting & making good the walls etc. |
| 174 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. |
| 175 | 110mm diameter |
| 176 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. |
| 177 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 178 | 110mm |
| 179 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 180 | Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. |
| 181 | (internal work) |
| 182 | Exposed on wall |
| 183 | 32mm dia nominal bore |
| 184 | Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality. |
| 185 | 32mm dia nominal bore. |
| 186 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. |
| 187 | internal work -Exposed on wall |
| 188 | 20mm dia nominal outer dia pipes |
| 189 | 25mm dia nominal outer dia pipes |
| 190 | 32mm dia nominal outer dia pipes |
| 191 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. |
| 192 | Concealed work including cutting chases and making good the walls etc. |
| 193 | 15mm dia nominal outer dia pipes |
| 194 | 20mm dia nominal outer dia pipes |
| 195 | 25mm dia nominal outer dia pipes |
| 196 | Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 |
| 197 | 15mm nominal bore |
| 198 | Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 |
| 199 | 15mm nominal bore |
| 200 | Providing & fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. |
| 201 | Providing and fixing gun metal gate valve with wheel of approved quality. |
| 202 | 25mm dia nominal bore |
| 203 | 20 mm dia nominal bore |
| 204 | 32mm dia nominal bore |
| 205 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete |
| 206 | 25 mm nominal bore |
| 207 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank. IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 208 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required, |
| 209 | in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. |
| 210 | Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. |
| 211 | Providing, laying and joining glazed stone ware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. |
| 212 | 100mm diameter |
| 213 | 150mm diameter |
| 214 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. |
| 215 | 100mm diameterS.W. Pipe |
| 216 | 150mm diameterS.W. Pipe |
| 217 | Providing and fixing square mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design: |
| 218 | 150 x 100 mm. size P type |
| 219 | With Sewer bricks conforming to IS : 4885 |
| 220 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design |
| 221 | Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). |
| 222 | With FPS bricks of class designation 75 |
| 223 | (i) For Sewer Line |
| 224 | Extra for depth of man hole size 90x80 cm |
| 225 | Inside size 90x120 cm & 90 cm deep including C.I. cover with frame (medium duty) total wt. of cover & frame to be not less than 116 Kg (wt. of cover 58 Kg & wt. of frame 58 Kg. |
| 226 | Extra for depth of man hole size 90x120 cm |
| 227 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design |
| 228 | With 20x20 mm square bar |
| 229 | EXTERNAL WATER SUPPLY SYSTEM |
| 230 | Provding and fixing gun metal non return valve of approved quality (screwed end) |
| 231 | 50 mm nominal bore |
| 232 | Vertical |
| 233 | Providing & fixing G.I. pipes complete with G.I. fittings includingtenching and refilling etc. |
| 234 | External work |
| 235 | 32mm nominal bore. |
| 236 | 50mm nominal bore. |
| 237 | Providing & fixing sand of grading zone V or coaser grade alround the G.I. Pipes in external work. |
| 238 | 32 mm diameter pipe |
| 239 | 50 mm diameter pipe |
| 240 | Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. |
| 241 | 32 mm nominal bore |
| 242 | 50 mm nominal bore |
| 243 | Constructing masonry Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand ) for sluice valve, with C.I. surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : |
| 244 | With F.P.S. bricks |
| 245 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : |
| 246 | 25 to 40 mm dia nominal bore |
| 247 | 50 to 80 mm dia nominal bore |
| 248 | Supply and fixing of UPVC S.W.R. pipe type-B confirming to IS-13592 including jointing the pipes with rubber ring,lubricant and UPVC SWR cupler confirming to IS-14735. Also including excavation of treanches cutting of walls and holes and repairing the walls,floors and refilling the trenches as before but excluding supply and cost of other fIttlings such as elbow,bend,tee and y-tee including supply of al marerial labour and T&P.Required for proper completion of work. |
| 249 | 90 mm O.D. |
| 250 | 110 mm O.D. |
| 251 | Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali. |
| 252 | Supply and fixing of UPVC S.W.R. plain bend confirming to IS-14735. |
| 253 | Size 90 mm |
| 254 | Size 110 mm |
| 255 | Supply and fixing of UPVC S.W.R. Cowel confirming to IS-14735. |
| 256 | Size 75/90 mm |
| 257 | Size 110 mm |
| 258 | Supply and fixing of UPVC S.W.R. plain tee confirming to IS-14735. |
| 259 | Size 90x90x90 mm |
| 260 | Size 110x110x110 mm |
| 261 | Supply and fixing of UPVC S.W.R. plain Y confirming to IS-14735. |
| 262 | Size 90 mm |
| 263 | Size 110 mm |
| 264 | FIRE FIGHTING |
| 265 | (A) Supplying, Installation, Testing & Commissioning ofElectric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required:(Terrace Pump) |
| 266 | (B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal confirming to IS 1520. |
| 267 | (C) Suitable HP Squirrel cage indution motor, TEFC type suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, confirming to IS-325. |
| 268 | (D) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. |
| 269 | (E) Suitable cement concrete foundation duly plastered with anti vibration pads. |
| 270 | 450 lpm at 35 m head |
| 271 | Providing, laying, testing & Commissioning of\"C\" class heavy duty MS pipe confirming to IS 3589/IS1239 inculding welding, fittings like elbows,tees, langes,tapers,nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of syntetic enamel paint of required shade complete as required: |
| 272 | 25 mm dia |
| 273 | 100 mm dia |
| 274 | Supplying & fixing single headed internal yard hydrant valve with instantaneousGunmetal/Stainless Steel coupling of63 mm dia with cast iron wheel, ISI marked, confirming to IS 5290(type A) with blank Gunmetal/Stainless Steel cap and chain as required: |
| 275 | Single headed Gunmetal |
| 276 | Supplying, fixing, testing & commission of butterfly valve ofPN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets confirming to IS 13095 of following sizes as required: |
| 277 | 100 mm dia |
| 278 | Supplying & fixing orifice plate made out of 6 mm thick stainless steel(grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required: |
| 279 | Providing, installation, testing and commission of non-return valve offollowing sizes confirming to IS: 5312 complete with rubber gaskets GI bolts, nuts, washers etc as required: |
| 280 | 100 mm dia |
| 281 | Supplying & fixing 63 mm dia, 15m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. confirming to IS 636(type-A) as required: |
| 282 | Gun Metal |
| 283 | Supplying & fixing First-aid hose Reel with MS construction spray painted in post office red,conforming to IS 884 complete with the following as required. |
| 284 | 20 mm nominal internal dia water hose thermoplastic(Textile reinforced) type-2 as per IS:12585 |
| 285 | 20 mm nominal internal dia gun metal globe valve & nozzle. |
| 286 | Drum and brackets for fixing the equipments on wall. |
| 287 | Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. |
| 288 | 30 m |
| 289 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle confirming to IS:903 suitable for instantaneous connection to interconnect hos pipe coupling as required. |
| 290 | Gun Metal |
| 291 | Supplying & fixing air vessel made out of 250 mm dia,8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. |
| 292 | Providing & fixing of pressure switch in M.S. pipe line including connection etc as required. |
| 293 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank. IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 294 | FIRE DETECTION & ALARM SYSTEM |
| 295 | Supplying, installation, testing & commissioning of Manual call Boxes of MS constuction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. |
| 296 | Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box(16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching trasformer etc. complete as required. |
| 297 | Supplying & laying of 2X1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 298 | Supply and fixing of following size of PVC conduit alongwith the accessories in recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: |
| 299 | 25mm |
| 300 | Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilityes as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. |
| 301 | 4 Zone |
| 302 | Providing, laying, testing & Commissioning of\"C\" class heavy duty MS pipe confirming to IS 3589/IS1239 inculding welding, fittings like elbows,tees, langes,tapers,nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of syntetic enamel paint of required shade complete as required: |
| 303 | 80 mm dia |
| 304 | 100 mm dia |
| 305 | Supplying & fixing single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, confirming to IS 5290(type A) with blank Gunmetal/Stainless Steel cap and chain as required: |
| 306 | Single headed Gunmetal |
| 307 | Supplying, fixing, testing & commission of butterfly valve ofPN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets confirming to IS 13095 of following sizes as required: |
| 308 | 80 mm dia |
| 309 | 100 mm dia |
| 310 | Providing, installation, testing and commission of non-return valve offollowing sizes confirming to IS: 5312 complete with rubber gaskets GI bolts, nuts, washers etc as required: |
| 311 | 100 mm dia |
| 312 | Supplying & fixing 63 mm dia, 15m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. confirming to IS 636(type-A) as required: |
| 313 | Gun Metal |
| 314 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle confirming to IS:903 suitable for instantaneous connection to interconnect hos pipe coupling as required. |
| 315 | Gun Metal |
| 316 | Supplying & fixing ofFire brigade connection of cast iron body with gun metal male instantaneous inlet coupling complete with cap and chain as required. for suitable dia MS pipe connection conforming to IS 904 as required: |
| 317 | 2 way-100 mm dia M.S. Pipe |
| 318 | Supply & fixing of fire extinguisher, ABC Type 6.00 kg. capacity(ISI Marked IS:15683 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 319 | Supply & fixing of CO2 type fire extinguisher,6.5 kg. capacity(ISI Marked IS:2878 & TAC approved) comlete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. |
| 320 | Providing/Fixing of Fire Hose cabinet box made out of 18 gauge MS sheet including two coats of post office red paint over one coat of primer with 4 mm, thick glass door in front painted “FIRE” in red luminous paint. The size of the box should be 750 mm X 600 mm X 250 mm size capable of accommodating a pair of hose with coupling and nozzle. The box should be floor mounted type with railway coach lock arrangement and lever for opening the door after breaking the glass complete.Make : Standard/Lifeguard or EQ. |
| 321 | Supplying and fixing of Fire man axe.Make :- Agni Suraksha (ASES) or EQ |
| 322 | Supply, Installation, Testing and Commissioning of electronic siren with suitable audible range of 1 k.m. approximately 4 watt.complete in all respects. Make :- Agni Suraksha (ASES) or EQ. |
| 323 | Providing/Fixing of cubical type floor mounted Fire pump control panel fabricated from 16 G M.S. sheet duly powder coated finish of approved shade and comprisingof :a) 40 amp 3 Pole MCCB, 50Hz with breaking capacity 10KW.b)One Volt meter (0-500 V) with selector switch.c) One set including lamps.Make :- Make :- Agni Suraksha (ASES)/ABB/L&T or EQ. |
| 324 | SEPTIC TANK & SOAK PIT |
| 325 | Size :- Length = 5.00 M. Width = 2.00M Total Depth =3.00M |
| 326 | Earth work in excavation over areas including disposal of excavated earth, lead upto 50m, disposed earth to be levelled and neatly dressed. |
| 327 | In all kind of soil upto 1.5m depth |
| 328 | In all kind of soil upto 1.5m to 3.0m. depth |
| 329 | In all kind of soil upto 3.0m to 4.5m. depth |
| 330 | Providing and laying of cement concrete in base excluding the cost of centring and shuttering by 1:2:4 (1 cement : 2 coarse sand : 4 gradded stone aggregae 20mm nominal size) |
| 331 | Brick work with brick of class designation 150 in foundation and plinth in cement mortar (1 cement : 4 coarse sand) |
| 332 | Reinforcement cement concrete work in RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarse sand and 3 gradded stone aggregate of 20 mm nominal size) including centering and shuttering and reinforcement. |
| 333 | TMT Fe-500 in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 334 | 15mm cement plaster on rough side of mix 1:4 (1 cement : 4 coarse sand) |
| 335 | Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. |
| 336 | Providing and fixing C.I. tee at the inlet and outlet of septic tank. |
| 337 | Providing & fixing 75mm dia vent pipes. |
| 338 | Providing & fixing of 75mm dia cast iron terminal guard. |
| 339 | M.D. -10- Circular shape 500mm internal diameter |
| 340 | M.D. -2.5- Circular shape 450mm internal diameter |
| 341 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. |
| 342 | With F.P.S. bricks |
| 343 | Centering and shuttering including strutting, propping etc. and removal. |
| 344 | UPGRADATION OF BOUNDRY WALL (519.20 RM) |
| 345 | R.C.C. work in Beam |
| 346 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 347 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 348 | Mild steel or iron in plain work such as reinforced concrete or reinforced, brick workbending for proper shap as necessary including bending for proper completion of thework andincluding supply of steel itswastage bendhooks andauthorisedover lappingshallbe measured. |
| 349 | M-150 Brick work in Super Structure in 1:6 cement and coarse sand mortar necessary cutting & moulding of brick as required thickness of walls not to be less than 1-1/2 brick. including supply of all materiallabour, Tools & Plants etc.required for proper completion of the work |
| 350 | 12 mm cement plasterinsingle coat on fair sideofsingle orhalfbrick wall for interior plastering up to floor twolevelincludinginternalrounded angles not exceeding80mm ingirth and finshed even and smooth.(1)1 cement:6 fine sand 1.25 F.M. |
| 351 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm |
| 352 | Steel reinforcement for R.C.C. work ready to use “cut and bend” rebars of approved make fromfactory/workshop to construction site includin placing in position and binding all complete above plinth level. 5.22C.1 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 353 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. |
| 354 | Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 355 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 356 | Lintels, beams, plinth beams, girders, bressumers andcantilevers |
| 357 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 358 | Column |
| 359 | COST OF SIGNAGE /INTERPATION WALL about theme of Kabir das gurunanak ravidas & Guru Gorakhsh Nath & Sant Keshavdas (CIVIL WORK) (07 Nos) |
| 360 | Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. |
| 361 | Providing and laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone ballast 40 mm nominal size) and curing complete,including cost of form- work, in foundation. |
| 362 | R.C.C. (M-20) work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. The rate excludes making of drip course which shall be paid extra. |
| 363 | As in item 3 abovebut inR.C.C.beamwithapproved stone ballast.(Using1:1.5:3Mix concrete) |
| 364 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in footing excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item.(M-20) |
| 365 | R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone ballast in the proportion of 1:1.5:3 (M-20) in columns excluding supply of reinforcement and its fixing and binding the same with 24 B.W.G.G.I. binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. Binding wire cost being inluded in the item.(M-20) |
| 366 | P/F TMT Bar -Fe 500 in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 367 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : |
| 368 | Red sand stone - Exposed face machine cut and table rubbed with rough backing. 40 mm thick |
| 369 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 370 | (a) Foundations, footings, bases of columns, etc. for mass concrete |
| 371 | (b) Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 372 | (c) Columns, Pillars, Piers, Abutments, Posts and Struts |
| 373 | INTERLOCKING PAVER front side parking (971.50 sqm) |
| 374 | Earth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 50 meter and including filling, watering and ramming of excavated earthdisposal of sur-plus earth as directed by the Engineer incharge up to a distance of 50 meters from the foundation trenches. (DSR 2.8.1) |
| 375 | Providing and layingin cement concrete 1:4:8 (1 cement: 4 coarse sand : 8 graded Stone aggregate 40 mm nominal size) and curing complete, including cost ofform-work, in foundation and floors. DSR 4.1.8 |
| 376 | M-150 brick work in 1:4 (one cement and four coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 377 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-inCharge. |
| 378 | 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern |
| 379 | SAND STONE PATHWAY (arround kund & green area) 1631 SQM) |
| 380 | Earth work in Excavation in trenches for foundations pipes cable etc in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 50 meter and including filling, watering and ramming of excavated earthdisposal of sur-plus earth as directed by the Engineer incharge up to a distance of 50 meters from the foundation trenches. (DSR 2.8.1) |
| 381 | Providing and layingin cement concrete 1:4:8 (1 cement: 4 coarse sand : 8 graded Stone aggregate 40 mm nominal size) and curing complete, including cost ofform-work, in foundation and floors. DSR 4.1.8 |
| 382 | M-150 brick work in 1:4 (one cement and four coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 383 | 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar.Red sand stone |
| 384 | HORTICULTURE AND LANDSCAPING |
| 385 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 386 | Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or / and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). |
| 387 | Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment). |
| 388 | Supplying and stacking well decomposed cow dung manure at site including royalty and carriage upto site (cow dung measured in stacked will be reduced by 8% for payment.) |
| 389 | Anti termite treatment of lawn area through premise 30.50% I P. one literpremise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge.and as per direction of officer-in-charge. |
| 390 | Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge. |
| 391 | GRASS PLANTING WORK |
| 392 | Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge |
| 393 | GROUND COVER/ PLANTING WORKS |
| 394 | Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20%: one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately) |
| 395 | SHRUB PLANTING WORKS |
| 396 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing includingremoval of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) |
| 397 | Holes 60 cm dia, and 60 cm deep |
| 398 | Providing and stacking of Ficus benjamina (green) of height 150-165 cm., bushy with healthy branches and lush green foliage in big size HDPE bags as per direction of the officer-in-charge. |
| 399 | Providing and stacking of Foxtail palm of ht. 240-270 cm bottom girth 35- 40 cm well developed in big size HDPE bags as per direction of the officer-in-charge. |
| 400 | Providing and stacking of Ficus blackii (F.vivion) of height 45-60 cm. with 6- 8 branches healthy foliage in earthen pots of size 25 cm as per direction of the officer-in-charge. |
| 401 | Providing and Displaying Ficus black vivion piller Topiary (sylinder type) well developed with fresh & healthy 180 to 210 cm ht in 40 cm Cement Pot as per direction of the officer-in-charge. |
| 402 | Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm. with 3-4 branches and thick stem in big size HDPE bags as per direction of the officer-in-charge. |
| 403 | Providing and Displaying Bamboo Buddha Valley with fresh & healthy 5 to 6 suckers 1.80 m to 2.10m ht umbrella type well developed in 50 cm Cement Pot as per direction of the officer-in-charge. |
| 404 | Providing and stacking of Bottle palm of ht. 150-180 cm bottom girth 20-25 cm well developed in big poly bags of size 25 cm as per direction of the officer-in-charge. |
| 405 | Providing and stacking of Polyalthia pendula (Ashok Pendula) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge. |
| 406 | External water suplly from submersiblepump (85 RM) (Detail As per TS Estimate) |
| 407 | GAZIBO (2 Nos) |
| 408 | Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. |
| 409 | Filling of Carted earth |
| 410 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km. (5 miles) from the site of work and including watering, ramming, dressing etc rate to include cost of all materials, labour and T & P etc required for proper completion of the work. |
| 411 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. |
| 412 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground |
| 413 | floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm |
| 414 | (4) Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm. |
| 415 | R.C.C. work in slab |
| 416 | R.C.C.work in beams |
| 417 | R.C.C.work in footing foundation |
| 418 | R.C.C.work in Column |
| 419 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. |
| 420 | M-150 brick work in 1:6 (one cement and six coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 421 | Same as in item no. 12 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. |
| 422 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 423 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
| 424 | 15 mm cement plaster on rough side of single or half brick wall of mix: |
| 425 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. F.M.2.25 |
| 426 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 427 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : |
| 428 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 429 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 430 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment,V epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. |
| 431 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 432 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 433 | (a) Foundations, footings, bases of columns, etc. for mass concrete |
| 434 | (b) Suspended floors, roofs, landings, balconies and access platform |
| 435 | (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 436 | (d) Columns, Pillars, Piers, Abutments, Posts and Struts |
| 437 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigmentmatching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : |
| 438 | Red sand stone - Exposed face machine cut and table rubbed with rough backing |
| 439 | ELECTRICAL WORK |
| 440 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 441 | Group C |
| 442 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 443 | Submains : |
| 444 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 445 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 446 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 447 | 20 mm |
| 448 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 449 | 5/6 A switch |
| 450 | 3 pin 5/6 A socket outlet |
| 451 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 452 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 453 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 454 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 455 | MCB\"s & DB’s : |
| 456 | Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 457 | 4 way (4 + 12), Double door |
| 458 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 459 | Single pole |
| 460 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 461 | Supply and fixing of 40 Amp. TP MCB (10 KA) C Curve. CAT A |
| 462 | Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A |
| 463 | ELCB/RCCB Switches : |
| 464 | Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 465 | 40 A |
| 466 | Earthing Work : |
| 467 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 468 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 469 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 470 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 471 | Non-Schedule Items |
| 472 | Supply and fixing of Single light Wall Bracketon matching M.D.F.E.G. Board base etc.Complete in all respect. CAT. - AAA |
| 473 | Supply & fixing of recess mounting round 10 to 15 watt LED down Lighter complete in all respect. |
| 474 | S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. |
| 475 | PLUMBING WORK |
| 476 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. |
| 477 | 110 mm |
| 478 | Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 479 | 110 mm |
| 480 | [GAZIBO ] EXTRA HEIGHT (02 Nos) |
| 481 | Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. |
| 482 | Filling of Carted earth |
| 483 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km. (5 miles) from the site of work and including watering, ramming, dressing etc rate to include cost of all materials, labour and T & P etc required for proper completion of the work. |
| 484 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. |
| 485 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground |
| 486 | floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm |
| 487 | (4) Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm. |
| 488 | R.C.C. work in slab |
| 489 | R.C.C.work in beams |
| 490 | R.C.C.work in footing foundation |
| 491 | R.C.C.work in Column |
| 492 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. |
| 493 | M-150 brick work in 1:6 (one cement and six coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 494 | Same as in item no. 12 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. |
| 495 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 496 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
| 497 | 15 mm cement plaster on rough side of single or half brick wall of mix: |
| 498 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. F.M.2.25 |
| 499 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 500 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : |
| 501 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 502 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 503 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment,V epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. |
| 504 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 505 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 506 | (a) Foundations, footings, bases of columns, etc. for mass concrete |
| 507 | (b) Suspended floors, roofs, landings, balconies and access platform |
| 508 | (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 509 | (d) Columns, Pillars, Piers, Abutments, Posts and Struts |
| 510 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) includingpointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigmentmatching the stone shade : (To be secured to the backing and the sides by means of cramps andpins which shall be paid for separately) : |
| 511 | Red sand stone - Exposed face machine cut and table rubbed with rough backing |
| 512 | ELECTRICAL WORK |
| 513 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 514 | Group C |
| 515 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 516 | Submains : |
| 517 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 518 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 519 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 520 | 20 mm |
| 521 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 522 | 5/6 A switch |
| 523 | 3 pin 5/6 A socket outlet |
| 524 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 525 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 526 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 527 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 528 | MCB\"s & DB’s : |
| 529 | Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 530 | 4 way (4 + 12), Double door |
| 531 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 532 | Single pole |
| 533 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 534 | Supply and fixing of 40 Amp. TP MCB (10 KA) C Curve. CAT A |
| 535 | Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A |
| 536 | ELCB/RCCB Switches : |
| 537 | Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 538 | 40 A |
| 539 | Earthing Work : |
| 540 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 541 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 542 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 543 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 544 | Non-Schedule Items |
| 545 | Supply and fixing of Single light Wall Bracketon matching M.D.F.E.G. Board base etc.Complete in all respect. CAT. - AAA |
| 546 | Supply & fixing of recess mounting round 10 to 15 watt LED down Lighter complete in all respect. |
| 547 | S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. |
| 548 | PLUMBING WORK |
| 549 | Providing and fixing on wall face unplasticised-Rigid PVC rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion. |
| 550 | 110 mm |
| 551 | Providing and fixing unplasticised-PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 552 | 110 mm |
| 553 | COST OF STONE BENCHE (Supply, and fixing in position 3 seater sand Stone Benches, 1800*600*450 mm at site as per approved quality and design. including all cost of accesories, transportation etc. complete in all respect.) (Detail As per TS Estimate) |
| 554 | SOLAR LIGHTall in one Philips (Detail As per TS Estimate) |
| 555 | CONTROLLING WATER LOSSES IN GORAKH TALAIYA KUND |
| 556 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.2.8.1 All kinds of soil. |
| 557 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green.Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. (d) fourth and final layer of brick tiling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured. |
| 558 | HDPE SHEET 1 Layer at pond bottom(800 MICRON) |
| 559 | 1:1.5:3 (1 Cement: 1.5 coarse sand (zone-III) including manufactured sand derived fromRecycled Concrete Aggregate (RCA) upto 25% : 3 graded stone aggregate 20 mm nominalsize including Recycled Concrete Aggregate (RCA) upto 25%). |
| 560 | Demolishing brick work manually/ by mechanical means includingstacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 561 | MINI POND & CONNECTION |
| 562 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil. |
| 563 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 564 | Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) |
| 565 | Raised and cut pointing on stone work in white cement mortar 1:3 (1 white cement : 3marble dust). |
| 566 | Dry stone pitching 22.5 cm thick laid in courses and required profile with hammer dressedstones having no side less than 15 cm, with minimum depth of 20 cm including preparing the bedding surface etc. all complete. (Payment for Stone to be made separately). |
| 567 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. |
| 568 | 400 mm dia |
| 569 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design |
| 570 | Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover108 kg and weight of frame 100 kg) : |
| 571 | With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 572 | (i) For PIPE Line |
| 573 | Extra for depth of man hole size 90x120 cm |
| 574 | Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures\"s permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design. |
| 575 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) cement plastered on both sides with cement mortar ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : |
| 576 | For pipes 350 to 450 mm diameter |
| 577 | Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete |
| 578 | 450.mm diameter |
| 579 | Boring |
| 580 | T.W. boring of 200 mm dia with 150 mm dia P.V.C. pipe assembly, 7.50 H.P. submersible pump including supply of all accessories starter, panel etc. & pipe arrangements complete. |
| 581 | 8\" PVC casing pipe of ISI mark. |
| 582 | P/ F 3\" GI pipe (B) class. |
| 583 | Nylon mesh for filter. |
| 584 | Plastic dori. |
| 585 | Solvent cement. |
| 586 | 8\" End cap. |
| 587 | 8\" Submersible cap. |
| 588 | 3\" MS clamp (Heavy). |
| 589 | 3\" GI elbow. |
| 590 | 3\" X 6\" GI nipple. |
| 591 | 7.5 HP 9 Stage submersible pump of ISI mark with automatic panel. |
| 592 | 4.00 sqm. Submersible cable. |
| 593 | Drilling charges for16\" dia tubewell. |
| 594 | Pea Gravel. |
| 595 | 2\" MS socket. |
| 596 | Rope with plastic coated |
| 597 | Cartage of material upto site. |
| 598 | water collection tank at ground lvl(haudi) |
| 599 | Shop 01 Nos |
| 600 | Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. |
| 601 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 602 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. |
| 603 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. |
| 604 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground. |
| 605 | floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm |
| 606 | (4) Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm. |
| 607 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 608 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 609 | R.C.C. (M-20) work with cement approved coarse sand and 20 mm. guage approved stone grit in the proportion of 1:1.5:3 in Lighter Beam excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. strength of the concrete shall not beless than M-20. |
| 610 | R.C.C. Work IN FOOTING |
| 611 | R.C.C. Work in column |
| 612 | M-150 brick work in one cement & 6 coarse sand 2.25 F.M. mortar in foundation and plinth including supply of all materials labour, tools and plants etc. required for proper completion of the work. |
| 613 | Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) |
| 614 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 615 | M-150 Brick work in super-structure above plinth level up to floor two level (up to two storeys) includingnecessary cutting and moulding of bricks as requiredand also including honey comb brick work thickness of wall not to be less than 1.5 brick thick. (1:6 cement & coarse sand) |
| 616 | Same as in item no. 12 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. |
| 617 | Providing & laying \"brick Coba\" 120mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15mm to each other, over 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with acrylic cement concrete water proofing compound filled gaps of |
| 618 | coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono lythic plaster wall upto 30cm higher and junction and corner shall be rounded by brick |
| 619 | ballast cement and coarse sand masonry coba with top finished plaster mixed with acetic water proofing compound @ 2% by weight & including S/o all material, labour T & P etc complete for proper completion of work. |
| 620 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. |
| 621 | 35 mm thick (Single Leaf) |
| 622 | Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) both Side |
| 623 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. |
| 624 | Hold fast for chaukhats of doors/windows. |
| 625 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). (a) Second class teak wood |
| 626 | TMT FE-500 or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. |
| 627 | Fixing of Door, windows/ventilators chaukhats in position. |
| 628 | (a) Door |
| 629 | 15 mm thick plaster with cement mortar in proportion of 1:4 (1 cement: 4 coarse sand) cement & coarse sand in plinth. |
| 630 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. F.M.-2.25 |
| 631 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 fine sand. 2.25.F.M. |
| 632 | 12 mm cement plaster in ceiling to finshed even and smooth with mix of 1 cement : 3 coarse sand. |
| 633 | Addforplasterdripcourse/grooveinplasteredsurfaceormouldingto R.C.C.projections. |
| 634 | Ground & First floor |
| 635 | 40mm thick 1:2:4 plain cement concrete floor (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement. |
| 636 | Providing and laying 8 to 10 mm thick ivory or light shade vitrified tiles of 600 x 600 mm size in flooring or skirting laid with cement mortar 1:3 (1 cement : 3 coarse sand) finished with cement slurry & with pigment grouting & polishing complete including supply of all materials, labour, T & P etc. required for proper completion the work excluding base concrete. |
| 637 | Providing and laying 8 to 10 mm thick ivory or light shade vitrified tiles of 600 x 600 mm size in flooring or skirting laid with cement mortar 1:3 (1 cement : 3 coarse sand) finished with cement slurry & with pigment grouting & polishing complete including supply of all materials, labour, T & P etc. required for proper completion the work excluding base concrete. |
| 638 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. |
| 639 | Granite of any colour and shade (Area of slab over 0.50 sqm) |
| 640 | Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3, Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt, dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work. |
| 641 | Same as item above but on new wood surface. |
| 642 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 643 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials.(Ceiling) |
| 644 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand &anufacturer, over the plastered wall surface to prepare the surface even & smooth complete. |
| 645 | Supplying and fixing rolling SHUTTERS of approved make made 80x125mm (3\"x5\") cold rolled M.S. lath inter locked throughout their entire length and joined together at the end by end locks and mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete but excluding the cost of top cover and springs. |
| 646 | Providing and fixing ball bearing for rolling shutters. |
| 647 | Red Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : 40 mm thick |
| 648 | S.S.Cramp |
| 649 | Making of draing along with apron 150 X 150 MM |
| 650 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter |
| 651 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermalexpansion. 110 mm bend |
| 652 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm |
| 653 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 654 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 655 | (a) Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 656 | (b) Suspended floors, roofs, landings, balconies and access platform |
| 657 | (c) Foundations, footings, bases of columns, etc. for mass concrete |
| 658 | (d) Columns, Pillars, Piers, Abutments, Posts and Struts |
| 659 | ELECTRICAL WORK |
| 660 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 661 | Group C |
| 662 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 663 | Submains : |
| 664 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 665 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 666 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 667 | 20 mm |
| 668 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 669 | 5/6 A switch |
| 670 | 3 pin 5/6 A socket outlet |
| 671 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 672 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 673 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 674 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 675 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 676 | Upto 450 mm sweep |
| 677 | MCB\"s & DB’s : |
| 678 | Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 679 | 4 way (4 + 12), Double door |
| 680 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 681 | Single pole |
| 682 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 683 | Supply and fixing of 40 Amp. TP MCB (10 KA) C Curve. CAT A |
| 684 | Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A |
| 685 | ELCB/RCCB Switches : |
| 686 | Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 687 | 40 A |
| 688 | Earthing Work : |
| 689 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 690 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 691 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 692 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 693 | Supply and fixing of Single light Wall Bracketon matching M.D.F.E.G. Board base etc.Complete in all respect. CAT. - AAA |
| 694 | Supply & fixing of recess mounting round 10 to 15 watt LED down Lighter complete in all respect. |
| 695 | S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. |
| 696 | Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. |
| 697 | EARTH FILLING ON SITE |
| 698 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), includingdressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 699 | High Mast Light |
| 700 | Supply & Installation of High Mast 12.0mtr. Long with 180 watt LED 6 No. fitting with IP 65 Protection complete in all respect.(Including Panel) |
| 701 | supply and fixing of 15 amp SPN automatic street light cubicle control pannel with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 seeries with contactors ,HRC fuse,isolating switch,metering instrument,and instrument box with CTs etc.complete in all respect. |
| 702 | Cables |
| 703 | Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc.Following size |
| 704 | size 6 sq mm x 2 core |
| 705 | size 10 sq mm x 4 core |
| 706 | size 25 sq mm x 3-1/2core |
| 707 | Supply and fixing of brass nickle plated compression gland for pvc insulated & armoured served sheaththed ,underground cable including rubber ring etc. complete in all respect. Thearmouring of the cable shall be properly connected with the earthas per direction of engineer -incharge.for cable |
| 708 | size 6 sq mm |
| 709 | size 10 sq mm |
| 710 | size 25 sq mm |
| 711 | Supply and fixing ofplain or pin type copper tin plated cable socket (lug) to cable leadsfor pvc insulated & armoured cable insulating with tape and making connection. complete in all respect as per direction of engineer -incharge. for cable |
| 712 | size 6 sq mm |
| 713 | size 10 sq mm |
| 714 | External Painting on Existing Building |
| 715 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 716 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on ceiling to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost of all materials. (Inner walls) |
| 717 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 718 | Scraping old whit & colour wash including disposal of refuse as directed by the Engineer-in-charge with in a distance of 60m (Inner Wall) |
| 719 | SAND STONE FLOORING ON POND STEP & CHABUTRA EXTENSION & GRANIET FLOORING |
| 720 | 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar.Red sand stone |
| 721 | S.S. RAILING |
| 722 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. |
| 723 | Providing and fixing 18 mm thick (Granite) gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanitycounters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement,mixed with matching pigment, epoxy touch ups, including rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of slab over 0.50 sqm [IN FLOORING] |
| 724 | Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. |
| 725 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 726 | M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 727 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. |
| 728 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 729 | (a) Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 730 | DRAIN 300X450 (LENTH =75+30.6 +117.7+45.7 MTR) (269 RMT) |
| 731 | Earth work in excavation |
| 732 | P.C.C. 1:4:8 |
| 733 | Brick work in 1:4in foundation. |
| 734 | 12 MM thick plaster (1:4) |
| 735 | C.C. flooring |
| 736 | DISMATELLING & RECONSTRUCTION OF BOUNDRY WALL TWO PANNEL FOR HYDROLIC MECH. ( 5.120 Rmt.) |
| 737 | As per Details TS Estimate |
| 738 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 739 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 740 | Mild steel or iron in plain work such as reinforced concrete or reinforced, brick workbending for proper shap as necessary including bending for proper completion of thework andincluding supply of steel itswastage bendhooks andauthorisedover lappingshallbe measured. |
| 741 | M-150 Brick work in Super Structure in 1:6 cement and coarse sand mortar necessary cutting & moulding of brick as required thickness of walls not to be less than 1-1/2 brick. including supply of all materiallabour, Tools & Plants etc.required for proper completion of the work |
| 742 | 12 mm cement plasterinsingle coat on fair sideofsingle orhalfbrick wall for interior plastering up to floor twolevelincludinginternalrounded angles not exceeding80mm ingirth and finshed even and smooth.(1)1 cement:6 fine sand 1.25 F.M. |
| 743 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm |
| 744 | Steel reinforcement for R.C.C. work ready to use “cut and bend” rebars of approved make fromfactory/workshop to construction site includin placing in position and binding all complete above plinth level. 5.22C.1 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 745 | As per Details TS Estimate |
| 746 | Two or more coats on new work over an under coat of suitable shade with ordinary paint ofapproved brand and manufacture |
| 747 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 748 | Lintels, beams, plinth beams, girders, bressumers andcantilevers |
| 749 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 750 | Column |
| 751 | Demolishing brick work manually/ by mechanical means includingstacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 752 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - incharge. |
| 753 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. cum 494.10 Note - item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more. |
| 754 | WALL CUTTING |
| 755 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. |
| 756 | a) 110mm diameter |
| 757 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing completeso as to make it leak proof. |
| 758 | KITCHEN |
| 759 | Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. |
| 760 | Filling of Carted earth |
| 761 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km. (5 miles) from the site of work and including watering, ramming, dressing etc rate to include cost of all materials, labour and T & P etc required for proper completion of the work. |
| 762 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. |
| 763 | Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground |
| 764 | floor only shall be measured as per I.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1)Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm |
| 765 | (4) Treatment of soil along external perimeter of building 7.5 liters/sqm.(5) Treatment of soil under apron along external perimter 5 liters/sqm. |
| 766 | R.C.C. work in slab |
| 767 | R.C.C.work in beams |
| 768 | R.C.C.work in footing foundation |
| 769 | R.C.C.work in Column |
| 770 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. |
| 771 | M-150 brick work in 1:6 (one cement and six coarse sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 772 | Same as in item no. 12 but in1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work. |
| 773 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 774 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
| 775 | 15 mm cement plaster on rough side of single or half brick wall of mix: |
| 776 | 12mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or roundedangles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 coarse sand. F.M.2.25 |
| 777 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 fine sand |
| 778 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 779 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials.(Ceiling) |
| 780 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 781 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 782 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. |
| 783 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 784 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 785 | (a) Foundations, footings, bases of columns, etc. for mass concrete |
| 786 | (b) Suspended floors, roofs, landings, balconies and access platform |
| 787 | (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 788 | (d) Columns, Pillars, Piers, Abutments, Posts and Struts |
| 789 | Providing & laying \"brick coba\" 12 mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15 mm to each other, over 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with aerelic cement concrete water water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth & top mashed false square 30cm x cm and side wall parapet shall be mono tythic plaster wall upto 30 cm higher and junction |
| 790 | and corner shall be rounded by brick ballast cement and coarse sand masonary coba with top finished plaster mixed with acelic water proofing compound @ 2% by weight & including S/o all material, labour, T & P etc complete for proper completion of work. |
| 791 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, ofapproved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut withthe zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 792 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, ofapproved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut withthe zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 793 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
| 794 | (a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 795 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. |
| 796 | Hold fast for chaukhats of doors/windows. |
| 797 | Door / windows & Staircase grill. |
| 798 | Angle iron chaukhats size 40x40x5 |
| 799 | Z Section steel window |
| 800 | Fixing of Door, windows/ventilators chaukhats in position. |
| 801 | (a) Door |
| 802 | (b) Windows |
| 803 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes (weights not less than 10 kg/ sqm). |
| 804 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. |
| 805 | Providing & fixingAluminiumsliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 300mm x 16mm. |
| 806 | Providing and fixingAluminium. anodised towerbolts (barrel type) with necessary screws etc. complete. |
| 807 | (a)250 mm x 10mm |
| 808 | (a) 200 mm x 10mm |
| 809 | Providing and fixing S.S anodised handles with screws etc. complete (a) 125 mm. |
| 810 | Wiringforlightpoint/fanpoint/exhaustfan point/callbellpointwith1.5sq.mmFRLSPVC insulatedcopperconductorsinglecorecablein surface/recessedmediumclassPVCconduit, withmodulartypeswitch,modularplate, suitable size G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 811 | Group C |
| 812 | Wiringforcircuit/sub-mainwiringalongwith earthwirewiththefollowingsizeofFRPVC insulatedcopperconductor,singlecorecablein surface/ recessedmediumclassPVC conduitasrequired. |
| 813 | 2X1.5 sqmm + 1x1.5 sqmm earth wire |
| 814 | 2X2.5 sqmm + 1x 2.5 sqmm earth wire |
| 815 | 2X4.0 sqmm + 1x 4.0 sqmm earth wire |
| 816 | 2X6.0 sqmm + 1x 6.0 sqmm earth wire |
| 817 | Supplyinganddrawingco-axialTVcableRG-6 graded,0.7mmsolidcopperconductorPE insulated,shieldedwithfinetinnedcopperbraid andprotectedwithPVCsheathintheexisting surface/ recessed steel/ PVC conduit asrequired. |
| 818 | Say Rs. |
| 819 | Supply and fixing of following size of PVC conduitalongwiththeaccessoriesinrecess includingpaintingincaseofsurfaceconduit,or cuttingthewallandmakinggoodthesameincase of recessed conduit as required: |
| 820 | 20mm |
| 821 | Supplyingandfixingfollowingmodularswitch/ socketonthe existingmodularplate&switch boxincludingconnectionsbutexcludingmodular plate etc as required. |
| 822 | TV antenna socket outlet |
| 823 | Supply and fixing of stepped type electronic fan regulatorontheexistingmodularplateswitch boxincludingconnectionsbutexcluding modular plate etc. as required. |
| 824 | Supplying and fixing modular blanking plate on the existing modular plate & switch boxexcluding modular plate as required. |
| 825 | Supplying and fixingfollowing size/modules,GIboxalongwithmodularbase &coverplate for modular switches in recess etc as required. |
| 826 | 1 or 2 module(75mm X 75 mm ) |
| 827 | SupplyingandfixingsuitablesizeGIboxwith modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modularsocketoutletand5/6Amodularswitch,connection etc. as required. |
| 828 | SupplyingandfixingsuitablesizeGIboxwith modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,connection etc. as required. |
| 829 | Supplyingandfixing3pin5Aceilingroseon the existing junction box/woodedn blockincluding connectionetc. as required. |
| 830 | Supplyingandfixingbrassbatten/angleholderincluding connectionetc. as required. |
| 831 | Instalation,testing&commissioningofwall bracket/ceilingfittingsofallsizesandshapes containing upto two GLSCFL/LED lamps per fitting, complete with all accessories includingconnection etc. as required. |
| 832 | Installation, testing and commissioning of prewired,flourescentfitting/compact fluorescent fitting of all types,completewithall accessoriesandtubesetc.directlyonceiling/ wall, including connection with 1.5 sq. mm. PVC insulated, copper conductor, single core cable etc. as required. |
| 833 | Installation, testing and commissioning of ceiling fan,includingwiring thedownrodsof standard length(upto30cm)with1.5sq.mmFRLSPVC insulated, copper conductor, single core cable etc. Includingprovidingandfixingphenolic laminated sheet cover on the fan box etc. asrequired. |
| 834 | Numbering of ceiling fan/ exhaust fan/fluorescent fittings as required. |
| 835 | Installationofexhaustfanintheexisting opening, including making good the damage, connections, testing, commissioning etc. as required. |
| 836 | upto 450 mm sweep. |
| 837 | Extraforfixingthelouvers/shutterscomplete with frame fro exhaust fans of all sizes. |
| 838 | Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB,`C`curveincludingconnections,paintingetc. as required. |
| 839 | Providing and fixing circular/Hexagonal cast ironorM.S.sheetboxforceilingfanclamp,of internal dia 140 mm,73mmheight,top lidof 1.5 mmthickM.S.sheetwithitstopsurfacehacked for proper bonding, top lid shall bescrewed into the cast iron/M.S. sheet box by means of 3.3 mm diaroundheadedscrewed,onelocatthe conrners.Clampshallbemade of12mmdiaM.S. bar bent to shape as per standard drawing. |
| 840 | Supply,Installation,TestingandCommissioning of1200mmsweep,BEE5starrated,ceilingfan with Brush Less Disect Current(BLDC) motor, classofinsulation:B,3nos.blades,30cmlong down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9,ServiceValue(CM/M/W)minimum6,Airdelivery minimum 210 Cum/Min, 350 RPM(tolerance as per IS: 374-2019), THD less than10%remoteorelectronicregulatorunitfor speedcontrolandallremainingaccessories including safety pin, nut bolts, washers, temperaturerise=75degreeC(max.),insulation resistancemorethan2megaohm,suitablefor 230V,50Hz,singlephaseACSupply,earthingetc. complete as required. |
| 841 | Supplyingandfixing following way,singlepole and neutral sheet steel, MCB distribution board, 240Vonsurface/recesscomplete with,tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthingetc. asrequired(ButwithoutMCB/ RCCB / Isolators). |
| 842 | 12 way, Double door |
| 843 | Supplying and fixing 5 amps. to 32 amps. rating,240volts `C\"series, miniaturecircuit breaker (MCB)suitableforinductiveloadof following poles in theexisting MCB DB completewith connections,testingand commissioningetc.as required. |
| 844 | Single Pole |
| 845 | Double Pole |
| 846 | Supplyingandfixingsinglepole,blankingplate intheexistingMCBDBcompleteetc.asrequired. |
| 847 | EarthingwithGIearthpipe,600mmX600 mmX 6 mm thick including accessories and providingmasonaryenclosurewith coverplate having locking arrangementandwateringpipe of 2.7 metre long etc, with charcoal/cock and salt as required. |
| 848 | Supplying and Laying of 25 mm X 3 mm G.I strip at0.50metrebelowgroundasstripearth electrode, including connection / terminating withnut,bolt,spring,washeretc.asrequired.( jointing shall be done by overlapping and with 2 setsofG.I.nutbolt&springwasherspacedat50mm) |
| 849 | Supplying and Laying of 6 SWG G.I wireat 0.50 metre belowgroundlevelforconductorearth electrode, including connection / terminating with G.I. thimble etc. as required. |
| 850 | LayingofonenumberPVCinsulatedandPVC sheathed/XLPEpowercableof1.1KVgradeof following size direct in ground including excavation,sandcushioning,protectivecoveringand refilling the trench etc. as required. |
| 851 | Upto 35 sq. mm |
| 852 | Supplying&makingendterminationwithbrass compressionglandandaluminiumlugsforthe following size of PVC sheathed / XLPE aluminiumconductorcableof1.1KVgradeasrequired. |
| 853 | 2 X 10 sqmm. (19mm) |
| 854 | Providing,layingandfixingfollowingdiaG.I. pipe(mediumclass)ingroundcompletewithG.I. fittings including trenching (75 cm deep) andrefilling etc as required. |
| 855 | 50 mm Dia(Rate taken From Civil DSR 2021-18.12) |
| 856 | Supplyoffollowingsizeof1.1KVgrade multicore aluminium conductor PVC sheathedarmoured cable as per IS 1554. |
| 857 | 10 sqmm 2 core |
| 858 | Supply & fixing of7/9 W LED BULB complete inall respect. |
| 859 | Supply and fixing of LED Tube Light with battensuitableforupto1X20wattLEDtube light complete including tube etc. on surfacecomplete in all respect. |
| 860 | Supply&fixingofrecess/Surface/Pendent mounting round 10 to 15 watt LED Down LighterhavingPowdercoateddiecast aluminium housing with heat sink, diffuser/Reflectoranddriversetcompleteinallrespects. |
| 861 | Cat. AAA |
| 862 | Supply ofAC230/250Volts,50Hz55w1400 rpm exhaust fans including providing nuts, bolts, mountingframeandotheraccessoriesincluding connections etc. complete as required.-Make:Havells-STANDARD -Refresh Air-SPS |
| 863 | 300mm sweep. |
| 864 | PLUMBING WORK (As per TS Estimate |
| 865 | DRINKING WATER BOOTH |
| 866 | Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) & including filling, watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. |
| 867 | Providing and laying in cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 stone ballast 40 mm nominal size) and curing complete,including cost of form- work, in foundation and floors. |
| 868 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 kms. from the site of work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. |
| 869 | M-150 brick work in one cement & 6 coarse sand 2.25 F.M. mortar in foundation and plinth including supply of all materials labour, tools and plants etc. required for proper completion of the work. |
| 870 | R.C.C. work in slab (Using1:1.5:3Mix concrete) |
| 871 | As in item 5 abovebut inR.C.C.beamwithapproved stone ballast.(Using1:1.5:3Mix concrete) |
| 872 | As in item 5 above but in R.C.C. columns in 1:1.5:3 having strength not less than M-20. |
| 873 | As in item 5 abovebut inR.C.C.Raft foundation and footingwithapproved stone ballast. (Using1:1.5:3Mix concrete) |
| 874 | Class M-150 Brick work in super-structure above plinth level includingnecessary cutting and moulding of bricks as requiredand also including honey comb brick work thickness of wall not to be less than one brick thick. (1:4 cement & coarse sand) |
| 875 | 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) |
| 876 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. (Fe-500) |
| 877 | Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete Granite of any colour and shade |
| 878 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) |
| 879 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials.(Ceiling) |
| 880 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand &anufacturer, over the plastered wall surface to prepare the surface even & smooth complete. |
| 881 | Providing and laying water proofing treatment in sunken portion of W.C., bathroom etc, by applying cement slurry mixed with water proofing cement compound consisting of applying :- (a) First layer of slurry of cement @ 0.488 Kg/Sqm mixed with water proofing cement compound @ 0.253 kg/Sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 Kg/Sqm mixed with water proofing cement compound @ 0.126 kg/Sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 882 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the costof nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 883 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :(15 mm dia) |
| 884 | Providing and fixing G.I. Union in G.I. pipeincluding cutting and threading the pipe and making long screws etc. complete (New work) :(15 mm dia) |
| 885 | Providing and fixing G.I. pipes complete with G.I. fittings includingtrenching and refilling etc.(25 mm dia) |
| 886 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. |
| 887 | Supply of 110 mm dia PVC casing pipe for boring 6 kg/sqm ISI approved. |
| 888 | WATER TANK |
| 889 | Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust)with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. |
| 890 | Red Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : 40 mm thick |
| 891 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 892 | (a) Foundations, footings, bases of columns, etc. for mass concrete |
| 893 | (b) Suspended floors, roofs, landings, balconies and access platform |
| 894 | (c) Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 895 | (d) Columns, Pillars, Piers, Abutments, Posts and Struts |
| 896 | GST Extra As per Applicable |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail