}

Tender For Interception & Diversion And 5.0 M.L.D. Sewage Treatment Plant Works At Kalpi Nagar Palika Parishad Orai - Design, Construction, Supply Of All Materials, Erection And Commissioning Of 5.0 Mld Stp With Co Treatment Facilities Of 10.0 Kld With Ce, kalpi-Uttar Pradesh

Uttar Pradesh Jal Nigam has published Tender For Interception & Diversion And 5.0 M.L.D. Sewage Treatment Plant Works At Kalpi Nagar Palika Parishad Orai - Design, Construction, Supply Of All Materials, Erection And Commissioning Of 5.0 Mld Stp With Co Treatment Facilities Of 10.0 Kld With Ce. Submission Date for this Tender is 07-05-2025. Wall Construction Tenders in kalpi Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

48620718
Tender For Interception & Diversion And 5.0 M.L.D. Sewage Treatment Plant Works At Kalpi Nagar Palika Parishad Orai - Design, Construction, Supply Of All Materials, Erection And Commissioning Of 5.0 Mld Stp With Co Treatment Facilities Of 10.0 Kld With Ce
Open Tender
NCB
Uttar Pradesh
Kalpi
07-05-2025

Tender Documents

Tender Details

Tender For Interception & Diversion And 5.0 M.L.D. Sewage Treatment Plant Works At Kalpi Nagar Palika Parishad Orai - Design, Construction, Supply of all materials, Erection and Commissioning of 5.0 MLD STP with co treatment facilities of 10.0 KLD with cesspool vehicle 1no.-1000 ltr & 1 no. 2000 ltr with all the civil, electrical, mechanical, instrumentation and scada system, LT/HT panel, Transformer (1w+1s), sub station building, DG set with foundation foundation, required pumping plant, Sludge dewatering unit, admin buidling, laboratories, meter room and campus development [Clearance and levelling of site, it also includes Construction of Internal Road (CC Road), staff quarters as per requirement and specification, external water supply with tube well and pumping arrangement, electrification & street llighting and sanitation work) etc. all complete for STP with co-treatment etc. The cost is inclusive of, co-treatment, boundary wall (1.8m ht. above plinth level with RCC Column @3m c/c with plinth beam and foundation avg. 1.2m depth including reinforcement and RCC coping on top of wall with plaster (1:4) and painting (apex painting 3 coat) as per type design and drawing at the STP site. ,fully furnished administrative building having fully functional testing laboratory, PLC/SCADA Rooms, Power Generation building, Blower building, sludge handling system & other building required for technology proposed. OCEMS system at inlet & outlet of STP and master control station (MCS) at STP. Conference room suitable for 15 people, 4 rooms with a attached toilet for supervisory staff and a toilet block, drinking water cooler, all office rooms and conference room (Air Conditioned). 2 The scope also including ancillary works like R.C.C. approch road approximate 3.75 m width with 1.5 m wide inter locking shoulder each side from NH to proposed STP entry gate, boundary wall of campus with gate, staff quarter, office cum resident building for jal nigam officers internal C.C. roads 3.75 m wide and 2.0 m wide C.C. path ways, fire fighting arrangement, land scaping, site development & require furniture etc. and other works as defined in bid documents.etc. all complete). Prevailing norms for effluent discharge shall be adhered to achieve BOD < 10 ppm, COD < 50 ppm, TSS < 20 ppm, Fecal coliform (MPN/100ml) <230, pH= 6.5 to 8.5to get reusable quality of water for agricultural purposes. Outlet parameters shall also include TN < 10 ppm, Nh3N < 2 ppm and TP < 1 ppm) with full automation including PLC-SCADA and Instrumentation and treated effluent disposal line for treated water as per specifications on modular basis such as on given site area of about 0.50 Hactare. 3 SPS 4 Design, Construction, Supply of all materials, Erection and Commissioning of Sewage Pumping Station (6.0M Inner Dia)including Excavation, dewtering for sinking water, sump well, screen chamber, screens, sluice gates , Pump house and other works as defined in bid documents.etc. all complete)with full automation including PLC-SCADA etc complete the work. 5 RISING MAINS 6 Supply of following sizes /Class of D.I. Pipesas per IS-8329 /2000 or its latest amendments including F.O.R. destination and all taxes and insurance etc. complete. 7 D.I. Pipe Class K-7 8 From SPS to STP 9 400 mm dia 10 Excavation for pipe line with lift upto 1.5 m and lead upto 50 m including refilling , watering and ramming of excavated earth into trenches after laying pipe line, removal and disposal of surplus material upto a distance of 50 m. 11 In kankar mixed soil 12 Cartage from store to site of work following NP3 with specials from store to site of work, lowering the same into trenchs and laying true to alignment and gradient, including jointingproperly, testing of pipe line etc. complete. 13 400 mm dia 14 Construction of RCC thrust block at the bend including supply of all material, labour, T&P, etc. complete. 15 For 400 mm dia rising main. 16 Crossing of Culvert for laying Rising Main including supply and materials, labour, T&P, etc. complete. 17 Dismantling & Reinstatement of following type of surface including sorting out and staking of serviceable materials of disposal of unserviceable materials up to a distance of 50 M. 18 Bituminous Road 19 Interlocking Road 20 C.C. Road 21 Providing and laying of 700mm dia MS casing pipe 12mm thick by trenchless technology under railway track with outside PU coating of 1000 micron and inside PU coating of 500 micron along with providing & laying of carrier pipe of dia 400mm 5.00mm thick with outside PU coating of 1000micron and 500 micron including inside, providing and fixing of speed restriction caution board as per railway norms and 80mm dia GI drain and vent pipe, providing and fixing end seal on both ends to plug the annular space between casing and carrier pipe & underground probe radar survey to check any underground abstruction before finalising the alignment and to take precautionary measures from power supply distribution. 22 I&D Structure 23 Design and construction work of Interception and diversionStructure work including Excavation of earth base concrete R.C.C. structure at following situation with inlet Chamber ,Weir Wall ,S.S. screens ,Collection Chamber,outlet chamber wit all fittings and sluice Gates etc complete . 24 Rayyad Drain 25 GRAVITY MAIN 26 Providing all material labour T & P etc. for caution boards, night lamps.and watch & ward including barricading of roads on both side of tranch during construction(per meter of trench) for purpose of measurement and payment, length of trench will be considered. 27 Excavation for following depth below ground level for laying of sewers manholes, gully pits, chambers, sumps etc. in ordinary soil (earth, sand, loam, clay) including cutting of joint pits, ramming, dressing, leveling & refilling of trenches in 20 cm layers including watering and ramming the same with Disposal of surplus earth & other dismantled material from the sides of trenches 28 0 to 1.5 M B.G.L. 29 1.5 to 3.0 m B.G.L. 30 3.0 to 4.5 m B.G.L. 31 Provide and fix open(0-3.0m) and close(3.0m -10.50m) timbering in trenches for the different depth below G.L. consisting of 40 mm thick approvedapproved country wood plank for polling board, 125x125 mm form Indian Sal Woodand 100 mm dia ballies for struts @ 1.5 m c/c including removal after laying of sewer, both side of trenches will be taken as one side for the purpose of payment, area equal to length x depth of trenches. 32 0 to 3.00 M B.G.L. 33 3.0 to 4.5 m B.G.L. 34 Supply of NP3 / NP4 RCC pipe at site including loading unloading and including cost of rubber ring 35 600 mm dia(NP3) 36 Carting lying and jointing of following pipes and specials from store to the site of work, lowering the same into trenches in following depth below ground level true to alignment, caulking the joint with necessary spun yarnsbitumen soaked and jointing with 1 : 2 cement mortar in coarse sand including excavations of earth below invert level of pipe, including cost of jointing materials, hydraulic testing etc. but excluding refilling of trenches from ground level to the invert level of pipe. 37 600 mm dia 38 3.0 to 4.5 m B.G.L. 39 Concrete cradles with 20 mm gauge stone ballast with coarse sand and cement in proportion of 4:2:1 in foundation including supply of all materials, labour T&P etc. required for proper completion of work for laying of sewer 200 mm dia to 700 mm dia following depths in trench. 40 For class Ab Bedding 41 3.0 to 4.5 m B.G.L. 42 Treated Effluent 43 Supply of following sizes /Class of NP3 Pipesas per IS-8329 /2000 or its latest amendments including F.O.R. destination and all taxes and insurance etc. complete. 44 NP3 45 Treated effluent main upto Drain 46 600 mm dia 47 Excavation for pipe line in medium rock with lift upto 1.5 m and lead upto 50 m including refilling , watering and ramming of excavated earth into trenches after laying pipe line, removal and disposal of surplus material upto a distance of 50 m. 48 600 mm dia 49 In Kankar mixed soil 50 Cartage from store to site of work following NP3 with specials from store to site of work, lowering the same into trenchs and laying true to alignment and gradient, including jointing properly, testing of pipe line etc. complete. 51 600 mm dia 52 Supply of following sizes C.I.D.F/sluice gate including F.O.R. destination and taxes, insurance etc. complete as per IS-780 (1976) with working pressure 10 Kg./Sqcm 53 600 mm dia 54 Carting of following C.I.D/F sluice gate from store to site of work, lowering them intoi trenches, fixing, layinng and jointing in position with pipe line and testing etc. complete. 55 600 mm dia 56 Supply of all material and construct masnory type sluice gate chamber complete as per type design. 57 Dismantling of following type of surface including sorting out and staking of serviceablematerials of disposal of unserviceable materials up to a distance of 50 m. 58 Bituminous Road(P.W.D road) 59 Reinstatement of following type of surface including sorting out and staking of serviceablematerials of disposal of unserviceable materials up to a distance of 50 m. 60 Bituminous Road(P.W.D road) 61 Building works at SPS 62 LT & HT Room at SPS 63 Design & construction of LT & HT panel building of RCC framed structure on raft/pile foundation floor height 3.60m with provision of electrification, painting, flooring, door, windows, ventilators, drainage, waterproofing of roof including supply of all materials, labour, T&P all complete in accordance to UPPWD/UPJN specification as per direction of Engineer In-Charge. 64 Meter Room at SPS 65 Design & construction of Meter Room building of RCC framed structure of suitable dimension on raft/pile foundation floor height 3.60 m with provision of electrification, painting, flooring, door, windows, ventilators, drainage, waterproofing of roof including supply of all materials, labour, T&P all complete in accordance to UPPWD/UPJN specifications as per direction of Engineer-In-charge. 66 Staff Quarter at SPS 67 Design & construction of Staff Quarter building of RCC framed structure of suitable dimension on raft/pile foundation floor height 3.00 m with provision of balcony, utility space, internal water supply sanitary and electric installation, painting, flooring, door, windows, vantilators, wardrobe, drainage, staircase, mumty, parapet wall, chhajja, waterproofing of roof, construction of spectic tank including supply of all materials, labour, T&P all complete in accordance to UPPWD specifications as per direction of Engineer-In-charge. 68 Type-1 (G+1) - 2 Nos 69 Road and Gate at SPS campus 70 Construction of boundary wall around STP and Sump/Pump house as per type design including supply of all Materials, Labour, Tools and Plants etc. all complete. 71 Supply & fixing of 3.60 M wide MS Gate including fabrication and supply of steel and construction of boundary pillars all complete. 72 Supply & fixing of 1.20 M wide MS Wicket Gate including fabrication and supply of steel and construction of boundary pillars all complete. 73 Construction of CC 1:1.5:3 approach road 150 mm thick of proper specification including supply of all material, labour and T&P of required width from main road to SPS campus for provision of proper connectivity as per direction of Engineer-in-charge. 74 E&M Works 75 Supply of submersible centrifugal sewage non-clog pumps, vertical spindle type pump, wear resistance with submersible motor for the various duty conditions. Pump shall be capable of handling min 100 mm solid size with sewage specific gravity of up to 1.05. Pump shall be of robust construction,. Pump Impeller should be of CF8M Nonclog semi open type, single vane / two vane vane preferably contra bloc or vortex impeller design. Double mechanical seal with silicon carbide faces should be provided, Pumps should have double bearings between the pump & motor. The bearings life shall be minimum 100,000 hrs of operation with greased for life. Pump should be provided with automatic coupling device including pedestal, stainless steel guide pipe or related accessories of suitable size to facilitate lifting and lowering into guide rails for easy maintenance. Pump shall be provided with a stainless steel lifting chain conforming to BS 970 Gr 304. Pump speed shall be of 1450 rpm, Casing should be of CI Gr. FG 260 :IS210 with 2% NICI, Shaft should be of stainless steel AISI 410. All the fasteners and bolts shall be of AISI 410. 76 The submersible motor shall be operated with 3ph, 415 V(+/-10%), 50Hz(+/-5 %) dry induction type.The rotating assembly shall be dynamically balanced as per standards. Motor should be of IE2, explosion proof compatible for operation together with VFD/ Soft starter, protection against increase in stator winding temperature (15 deg Celsius), bearing temperature, leakage in the stator housing and terminal box shall be provided and to be suitably interlocked with the control panel for tripping the pump in case of increase in temperature beyond set limit. Insulation class shall be of Class H and degree of protection shall be of IP 68 as per IS 4691. Motor shall be suitable for continuous operation in fully submerged or partially submerged condition.The pumpset shall be supplied with power cable of PVC/XLPE insulated, copper, flexible, round type with required conductor size and number of cores as per starting method and of specified length for continuous use under water and air, shall be provided of suitable size of following capacity. 77 CAPACITY:- 5625 LPM/27 Mtr. HEAD/60 HP (2w+1s) 78 CAPACITY:- 2400 LPM/27 Mtr. HEAD/30 HP (1w+1s) 79 MAIN PIPING AND VALVES :- 80 Supply of DIDF Single Door/ Multi Door Non return/reflux valve conforming to relevent IS, PN-1.0 to be fixed after pumps for 90% fast closing & 10% slow closing suitable for sewage applications of following size 81 250 mm dia size 82 200 mm dia size 83 Supply of DIDF Electrically integrated actuater (Totally enclosed, weather-proof and dust proof construction with IP-67, protection class suitable for installation in any position without lubrication, leakage or other operational difficulty with special grease filled gear box and suitable for manual operation for emergency which will automatically dis-engage on restoration of power to motor and with 10 watt single phase space heater and continuous local mechanical position indicator and individually replaceable counter gear assembly and with two torque and four limit switches with S.S. flap and operated with gear driven cams and of rating 250 Volt, 5 Amp, AC/DC, torque switch dial and with TEFC squirrel cage induction) operated sluice valve suitable to SCADA operation Valves are suitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0) of following sizes suitable for sewage applications. 84 Sluice valve size - 250mm dia at pump delivery 85 Sluice valve size - 200mm dia at pump delivery 86 Supply of DIDF manually operated sluice valve Valves are suitable for hydrostatic test pressure of 10Kg./Cm2 for seat and 15Kg./Cm2 for body(PN-1.0 Rating) Sluice Valve of 350 mm dia size at Common Header 87 Supply of DIDF main piping of following sizes.350 x250 x350 mm DI D/F Tee -3 No350 x200 x350 mm DI D/F Tee -2 No250 mm DI D/F Pipe 1.50 mt. - 3 No250 mm DI D/F Pipe 5 mt. - 6 No200 mm DI D/F Pipe 1.50 mt. - 2 No200 mm DI D/F Pipe 5 mt. - 4 No350 mm DI D/F Pipe 0.50 mt. - 4 No250 mm DI D/F Bend 90° - 3 No200 mm DI D/F Bend 90° - 2 No250 mm DI D/F Duck foot Bend - 3 No200 mm DI D/F Duck foot Bend -2 No350 mm DI D/F Bend 90° - 1 No350 mm Blind Flange - 1 NoAir Valve for common Header, Necessary Nut Bolts & Rubber Packing - 1 Lot (SS-304), Tools- 1 Set MS Chequred plate, MS Chanels and Angles- 1 Lot 88 Supply of D.I./ D.F. Dismantling Joints is a variable length Double Flanged Short Piece constituted by a flange / Spigot Tailpiece inserted into the other Tailpiece which allows the distance between the two flanges to be varied within certain limits thus providing a variable distance piece between two fixed flange end devices like Pumps and Valves. The Dismantling Joint to be supplied complete with Sealing Rubber Gaskets of EPDM quality (IS:5382/1985 Type4), Cast Iron Follower Glands and Mild Steel (Zinc Coated) Nut Bolts of Following size 89 Dismantling joint 200 mm dia size 90 Dismantling joint 250 mm dia size 91 Dismantling joint 350 mm dia size 92 3Ton capacity Electrically operated over head Travelling (EOT) crane suitable for a span upto 6 Mtrs, and travel length upto 10 Mtrs. with clear lift upto 6 M including gear type chain pulley block and geared Travelling trolley complete with all accessories including girder. 93 MOTOR CONTROL CENTER (MCC) PANEL:-Single front, Indoor & floor mounted,cubical type Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly powder coated dust and vermin proof IP-54 /1S:2147, considered Earth Bus-Bar-Gl Strip compitable to SCADA operation with RS485 Port consisting of INCOMMING SECTION 250A, 50KA, TPN, MCCB microprocessor baseed (O/C,S/C) release1 No, Spreader Links & Extended ROH for - 1 No, 3 Phase Digital Multifunction Meter - 1 No, Digital Voltmeter 0-500V 1 No, Digital Ammeter 0-400A - 1 Nos, CT For meter Resin Cast CL1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC- 1 Set, Control MCB SP 6A,10KA ABB - 3 Nos, CT Shorting Terminal - 4 Nos, Neutral Link - 1 No.OUTGOING SECTION160A, 50KA, TPN, MCCB microprocessor based (O/C,S/C) RELEASE - 3 No, 100A, 50KA, TPN, MCCB motorisesd & microprocessor based (O/C,S/C) RELEASE - 2 No Spreader Links & Extended ROH for MCCВ - 5 Nos.. 63A TPN MCCB 35KA - 2 Nos. Terminal 63A 94 Supply of Air Cooled The Variable frequency drive (VFD) shall be of a modern proven design, shall be fully digital, PLC/Microprocessor based, energy efficient, and shall provide very high reliability, high power factor, low harmonic distortion and low vibration and wear and noise, VFDs shall comply with the latest edition of IEEE 519 & IEC 61000 for both individual as well as total harmonic voltage and current distortion limits, VFD shall be capable of withstanding the thermal and dynamic stresses and the transient mechanical torque, resulting from short circuit. Any damage resulting from such a short circuit or internal fault shall be limited to the component concerned, VFD System shall maintain a power factor of 0.95 (minimum), Overall efficiency shall be minimum 96.5% for LV VFD, suitable for the LT motor offered for operation in AC three Phase 50Hz (+/-5%), 415V(+/-10%) suitable to SCADA operation with RS485 port offollowing rating. 95 Rating capacity 60 HP /45 KW 96 Rating capacity 30 HP / 22 KW 97 Supply of microprocessor based three phase sensing power factor correction relay panel, IEC / EN 61000-6- (2&4) communication interface with RS 485, indication of switching on units, auto/manual status, and shall have over load protection, no volt release, having multi parameter like KW, KVA, KVAR rating capacity of 40 KVAR. 98 Supply & Fixing of Powder coated GI Cable Tray 150mmx50mmx1.6mm 99 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 3 metre long etc. with charcoal/ coke and salt as required according to latest IS:3043 100 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 101 Supply of ABC Dry Powder type Fire Extinguisher 4.5 kg conforming to IS: 15683:2006 102 Supply of CE/UL Full bore Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media Water (Raw/ Chlorinated), Pressure: up to 1.0 MPa, Process temp: 50 deg C, Flow/Meter Tube: SS 304, Electrode: SS AISI 316L/ Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU), Flange: SS / CS, Flange Standard & Rating: ANSI 150, Coil housing: SS AISI 304/ Carbon Steel/ Die Càst Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy: + 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure: Die Cast Aluminium, Power Supply: 80 -240 V AC 50Hz, Output 1: 4-20 mA, Output 2: Pulse, Communication Output: RS 485/ Heart, Display Type: LCD/ LED Display, Cable Entry: M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parameters and totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, cable (size -350 mm dia at common header) 103 S& F of all in one solar LED street light fixture with Integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro Phosphate battery with BIS approved make luminaire should be secondary optic lenses for better distribution with delivered efficienacy of >100 Lumen per watt. Luminaire can be supplied with Hybrid switch along with indicator to understand the source of power( either from solar or AC supply).shall have certificate tested fromMNRE approved Lab. Guarantee for total system is two years Note: All the above should be integrated and should be 1 system.make: Bajaj/ Philips / Crompton. Compact Solar LED Street Light -40W/12V/27Ah with GI pole- 7 mtr 104 Internal & External electrification of Pump house 105 Twin tube light covered LED 20 Watt 106 450 mm dia exhaust fan 107 Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADG12 material 50 Watt Flood light 108 Complete wiring of Pump house with 1.5 Sqmm & 2.5 Sqmm multistarnd copper conductor wire 1.1 KV with required 5A & 15A switches, ceiling rose 109 Supply of CE/UL Certified Surge protector for control panel 110 Supply of Auto Phase reversal unit / Automatic switch with inbuilt the delay & enclosure (Confirms to IEC: 60947-1 & lEC: 60947-6-1) of 250Amp 111 Supply of CE/UL Certified pressure transmitter CE markd with following technical parameters at Sewage Pump delivery & common header line and Interfacing with PLC panel including mounting arrangement.Output 4-20 mA / HARTPower supply - 24V DC ext.Display - 4 LEDAccuracy -+/- 0.1 % of full scale or betterEnclosure- IP 68 112 Supply of CE/UL cirtified of Ultrasonic Radar type Ultrasonic leveltransmitter CE marked with following technical parameters at sewage Pump House and Interfacing with PLC panel includingmounting arrangement.Output-4-20 mA/ HARTPower supply - 24V DC ext.Display - 4 LEDRange- 0 to ...30.,. mtrsAccuracy - +/- 0.25% of Full Scale or betterEnclosure- IP 68 113 Rubber mats for electrical purpose as per IS:5425-1969, plain/chequered (1mX2m) - 19mm thickness 114 Supply of stainless steel (SS-316) Manual Coarse Bar screen with flat bar 50mm X 10mm, Spacing of bars 40mm suitable for mounting in channel of specified size with inclination not more than 45 degree and a movable covered containers of 1 cum capacity complete in all respect as per technical specification and the direction of the Engineer. Manually Raked Coarse Bar Screen with 50 mm clear opening for PEAK FLOW of 16 MLD 115 Supply of stainless steel (SS-316) Coarse Bar Multi Rake(mechanically raked) with flat bar 50mm X 10mm Spacing of bars 20 mm suitable for mounting in channel of specified size with inclination not more than 75 degree complete in all respect as per technical specification and the direction of the Engineer for PEAK FLOW of 16 MLD including belt conveyer 116 Installation, testing and comissioning of pumping plant & associated all equipments as per approved drawing shall be done by bidder including chequerred plate and painting of pumping plant & main piping-valves. 117 Testing of Pumping Plant & Control Panel & valves etc at Manufacturer Works 118 Supply of star rated Copper wound distribution Transformer (All the distribution transformer must be star rated as per notification of (BEE) ministry of power, Goverenment of India) of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11, ONAN Cooled & as per BEE star level- 2 & BIS approved as per IS 2026-1977 & losses as defined as per IS 1180 part (1) 2014 including standard accessories like conservator, silica gel breather,Bucholz relay, radiator, fins, HT cable box & LT cable boxes, Off -LTC (+7.5% to-15% @ 2.5%) temperature rise of 40 degree C in oil / 45 degree C in winding, ISI marked drain valve, Dial type Temperature gauge OTI & WTI, marshalling box, first filling of transformer oil as per IS :335-1953, Epoxy based paint.Rating capacity - 160 KVA (1w+1s) 119 Supply of 11KV, 630 A, 25kA / 1 Sec, VCB Indoor type panel HT board, free standing motor operated & withdrawal type fabricated from 2 mm thick CRCA sheet steel, With Ammeter, Voltmeter, PF Meter, KWH Meter, MDI Meter, Selector Switches as required, CRTCT of required ratio (15VA; Cl-1.0/0.5) PT (11 KV /110V/√3) Fuses, IP42 Protection,4 / 8/10/ 12-window Annunciation Panel, AC/ DC Control voltage 24/48/110/230V, LED Indication lamps, S/C, O/C & E/F Protection (IDMT) Relays Alarm & trip contacts for Transformer protection(High oil temperature, Buchholz protection, high winding temperature, power pack 2 x 12 V,etc complete in all respect ready to use(RTU),OEM Must have BIS certificate incuding 1no incoming & 2 no outgoing VСВ. 120 Supply and laying of 11/12KV grade XLPE H.T. cable as per IS:7098/I1/85, H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-I/ IS :7098 P - (I)from UPPCL metering panel to H.T. Switch gear panel and panel to transformers 120 Sq.mm. size 121 Supply of H.T. Cable end termination heat shrinkable type indoor joint kit 120 sq.mm. 122 Supply of H.T. Cable end termination heat shrinkable type outdoor joint kit 120 sq.mm. 123 Supply & laying of L.T.XLPE insulated armoured aluminium conductor cable of 1.1 KV grade Material :- H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-1 / IS :7098 P- (1),conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999.From transformer to Main LT panel of 3.5C x 150 Sq.mm. 124 Supply and Fixing of fire extinguisher of 5 Kg. capacity conforming to IS: 15683:2006 125 Rubber mats for electrical purpose as per IS:5425-1969, plain/chequered (1mX2m) - 19mm thickness 126 Single front, Indoor & floor mounted,cubical type LT Panel factory fabricated (2 mm thick for sructure, 1.6mm thick for door,covers shrouds and Gland Plate-3 mm thick) CRCA sheet duly powder coated dust and vermin proof IP-54 /IS:2147, considered Earth Bus-Bar-GI Strip compitable to SCADA operation with RS485 Port consisting ofINCOMMING SECTION250A, 50KA, TPN, MCCB microprocessor baseed (0/C,S/C) release3 No, Spreader Links & Extended ROH for - 3 No, 3 Phase Digital Multifunction Meter - 1 No, Digital Voltmeter 0-500V - 1 No, Digital Ammeter 0-400A 1 Nos, CT For meter Resin Cast CL1400A/5A,15VA - 3 Nos, Phase indication light LED type 220V AC-1 Set, Control MCB SP 6A,10KА ABB - 3 Nos, CT Shorting Terminal -4 Nos, Neutral Link 1 No.OUTGOING SECTION250A, 50KA, TPN, MCCB microprocessor based (O/C,S/C) RELEASE 2No, spreader Links & Extended ROH for MCCB 2No., 63A TPN MCCB 32KA - 2 Nos, Terminal 63A 127 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 3 metre long etc. with charcoal/ coke and salt as required according to latest IS:3043 128 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection terminating with nut, bolt, spring, washer etc, as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 129 NOC from electrical safety Govt. of UP 130 Fancing of substation in 2mtr height made from MS iron Jali & MS flat, angle iron and grouting in proper manner including supply and laying of stone grit. 131 Internal & External electrification of Meter/HT/LT room 132 Twin tube light covered LED 20 Watt 133 450 mm dia exhaust fan 134 Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material 50 Watt Flood light 135 Complete wiring of HT and LT room with 1.5 Sqmm & 2.5 Sqmm multistarnd copper conductor wire 1.1 KV with required 5A & 15A switches, ceiling rose 136 Installation, testing and commissioning of 11 KV /.44 KV substations including H.T. panel and L.T. panel including chequered plates, all labour T&P complete in all respect. 137 Supply of Silent DG Set (As per latest / CPCB IV emission norms) having specifications as per A, B, C, D, E,(A) 1500 RPM Diesel Engine conform to BS:649/5514 of suitable BHP Engine shall have residential silencer (isolated from main DG chamber), up to 3 M exhaust piping (with insulation & cladding) as required.(B )AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS 4722.-2001 Alternator shall be self regulated with standard AlternatorProtection( Over voltage, over speed & under voltage, under speed warning & shutdown). Engine & Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled.(C) Standard canopy with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet & filled with glass wool (96Kg/m3)/ Foam. as per IS 8183 the doors of 28/40/50/85 mm thick as per rating and fabricated from 1.6mm CRCA sheet packed with accoustic material,All doors/ opening are sealed with neoprene/EPDN gaskets. The enclosure has built in fueltank, with protection and tripping of DG set against temperature of more than 50ºC. 138 (D)Electronic / Mechanical governor, Manual & electric Start, Batteries with battry charger, Engine instruments panel,AVM pads All controls for operation of DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring & control system, MCCB/ACB of suitable rating,Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc, mounted inside enclosure, visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level shall be less than 75 dB at a distance of 1 Mtrs, duly certified by authorised agency etc. complete in all respect of following capacity:(E) - (A) Accoustic glass wool wall thickness should not be less then 40mm and not less then 20mm PU foam upto rating 100 KVA. (B).Accoustic glass wool wallthickness should not be less then 65mm and not less then 50mm PU foam upto rating 250 KVA. (C)Accoustic glass wool wall thickness should not be less then100mm for rating above 250 KVA.Rating capacity 160 KVA 139 Supply of Auto main failure (AMF) Panel fabricated from CRCA sheet steel 2 mmThick, Powder coated finish, Engine Start & Stop commands, control Relays,Ammeter & Voltmeter with selector switches, Control & 2 nos 4 pole Power Contactors with 2 no. of required size 4 pole MCCB, Timers, Electronic Hooter,Visual & Alarm indication for faults, UPS, operator interface panel complete in all respect suitable to DG sets. 140 Supply & laying of L.T.XLPE insulated & P.V.C. sheathed armoured aluminium cable of 1.1 KV grade Material :- H4- Grade aluminium conductor of purity >99.6 % & as per IS:1554 P-1 / IS :7098 P-(1),conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999. from DG set alternator to DG incomer panel of 3,5C x 150 Sq.mm. 141 Testing of HT / LT Panel /DG set at manufacturer works. 142 Installation commisioning and testing of DG set including panel,cabling and earthing complete in all respect with required all material and labour. 143 Construction of lock & key arrangement inclding shed and RCC foundation for above DG Set as per manufacturer drawing & design 144 CE & UL Certified PLC/ RTUwith redundant CPU & Power supply in IP 54 enclosure suitable to communicate with intelligent GSM Based modem unit with redundant CPU and Power Supply with analog and Digital Parameter and features as specified for each for each SPS/MPS to store and transmit data on GSM backbone, RTU designed with logic to tansfer data at multiple stations and also compatible for satellite communication alongwith control panel with IP 54 Protection, Industrial grade for all equipment and 24V and power supply. 145 GSM/GPRS based wireless communication with 4G modem for RTU/PLC Capable to transſer and gather data from remote sites to control stations all accessories included with signal enhancer, antenna made for pumping plant with SIM and recharge till Handed over 146 CE & UL Certified 10 HMI touch screen suitable to communication with PLC/RTU for local display & control of process parameters 147 CE/UL Certified Intelligent energy meters 148 Complete cabling of SCADA system. 149 Security Survelliance IP Camera 4 MP HD , NVR 2 SATA, 2 TB HDD with all required accessories for pump house, substation and campus . 150 Installation, Commissioning and testing of all above equipments 151 Trail and Run of 3 Month (except electricity charges)

Key Value

Document Fees
INR 23600 /-
EMD
INR 1276000.0 /-
Tender Value
INR 12.75 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail