| 1 | LIFT (6 PASSENGER CAPACITY) |
| 2 | Lifts (408 Kg Capacity for 6 Passenger, 01 Metre per second speed, Microprocessor Control) with power operated centre opening doors and AC variablevoltage & variable frequency controls variable voltage, variable frequency drive-V3F car size relevent to latest IS.Car enclosers : Stainless steel 304 Car with full width and full height Mirror, Diffused flourescent lighting, Presure fan with grill, PVC flooring cabin size wide 1000, deep 1100mm (high), Car door : Glass door centre opening 700mm (wide) x 2000mm (high), Landing door : Glass door centre opening 700mm (wide) x 2000mm (High) with special features : Landing push button digital position indicator in stainless steel plates.Car operating panel in stainless steel, battery operated alarm bell floor annunciate firemen switch emergency light with battery backup, with Automatic Rescue Device (ARD) system operates on dry maintenance freee batteries with 10 seconds actuation time and automatic switch over facility including all accessories, etc, complete. |
| 3 | (I) 1 Metre/Second speed, G+3 Travel height |
| 4 | (ii)Sheet Metal Structure (Thickness – 3mm, with ACP Sheet, Gearless, 6 Passenger |
| 5 | CIVIL WORKS |
| 6 | Centring and shuttering including strutting,propping,etc. and removal of form for: |
| 7 | (a)Foundations , footings , bases of columns etc. for mass concrete |
| 8 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete ABOVE plinth level. |
| 9 | (a)Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 10 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : |
| 11 | (a)1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal sizederived from natural sources) |
| 12 | 1:4:8 (1 Cement : 4 Coarse sand (Zone-III): 8 Graded stone aggregate mm 40 mm nominal size derived from natural sources. |
| 13 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and for all lift , as directed by Engineer-in-charge |
| 14 | (a)All kind of soil |
| 15 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, hold fasts etc.including stacking the material within 50 meterslead. |
| 16 | (a)Of area 3 sq. metres and below |
| 17 | Demolishing brick work and plaster , tiles etc. manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge . |
| 18 | (i)In cement mortar |
| 19 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 20 | Cement Mortar 1:6 (1 cement : 6 Coarse sand) |
| 21 | 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plater 1:3 (1 cement : 3 coarse sand) finished rough with sponge. |
| 22 | Finishing walls with textured exterior paint of reuired shade |
| 23 | New work (Two or more coat applied @ 3.28 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 24 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/liter of approved brand and anufacture, including applying additional coats wharever required to archieve enen shade and colour. |
| 25 | (a)Two coats |
| 26 | Providing and laying Double Chargedvitrified floortiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarsesand), including grouting the joints with white cement and matching pigments etc., complete. |
| 27 | (a)600mm x 600mm |
| 28 | E/M SERVICES |
| 29 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 30 | (a)Triplepole and neutral |
| 31 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 32 | 4 way (4 + 12), Double door |
| 33 | Supply and fixing of PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size 6 Sqmm, 4 Core on walls fixed with saddles/Clamps etc. |