| 1 | Dismantling of existing light/fan/ bell/socket out let point on separate board/wiring and circuit with insulated wire in casing/conduit/batten complete with fitting and accessories. |
| 2 | Making the site clear of the dismantled installation by refilling the hole with cement mortar & finished with paint gitties and replacing to match the colour& wall ceiling. |
| 3 | Dismantling of existing socket outlet point on same board in any system of wiring. |
| 4 | Dismantling the existing armoured/unarmouredcable or 2/3/4 wires of submain, main, in any system of wiring including recoiling. |
| 5 | Dismantling of D.F. board, D.P. switch, T.P. & T.P.N. switch or D.B. of any size complete with board or angle/flat iron frame and making site clear including the refilling hole & repainting to match colour of wall. |
| 6 | Dismantling of D.F. board, D.P. switch, T.P. & T.P.N. switch or D.B. of any size only |
| 7 | Dismantling the existingceiling/exhaust/cabin fan with complete accessories and making the site clear. |
| 8 | Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- UsingModular accessories- Light point/Fan points. Primary short point. |
| 9 | Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- UsingModular accessories- Light point/Fan points. Primary medium point. |
| 10 | Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for :- UsingModular accessories- Light point/Fan points. Primary long point. |
| 11 | 3 Pin 6 Amp socket outlet on separate board. Short point. |
| 12 | 3 Pin 6 Amp socket outlet on separate board. Medium point. |
| 13 | 3 Pin 6 Amp socket outlet on separate board. Long point. |
| 14 | Call bell/buzzer points. Short point. |
| 15 | Call bell/buzzer points. Medium point |
| 16 | Call bell/buzzer points. Long point. |
| 17 | Point wiring (excluding metallic switch box & sheet but including switches, sockets) for 3 pin 6 Amp. socket outlet point with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated copper earth continuity conductor of green colour inside casing & capping with required materials as per specification on same board. |
| 18 | Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. casing and caping ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside capping, screwless connector for joints as per specification for :-On separate board. UsingModular accessories On separate boardShort point |
| 19 | Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. casing and caping ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside capping, screwless connector for joints as per specification for :-On separate board. UsingModular accessories On separate board. Medium point |
| 20 | Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. casing and caping ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside capping, screwless connector for joints as per specification for :-On separate board. UsingModular accessories On separate board. Long point |
| 21 | Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. casing and caping ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside capping, screwless connector for joints as per specification for :-On separate board. UsingModular accessories On separate board. Extra long-I |
| 22 | Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. casing and caping ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside capping, screwless connector for joints as per specification for :-On separate board. UsingModular accessories On separate board. Extra long-II |
| 23 | Point wiring (excluding metallic switch box & sheet) for 3 Pin 16 Amp. socket outlet point with 4sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in surface rigid P.V.C. casing and caping ISI marked of suitable size etc. with 20/16 Amp. F.T. switch & socket/S.S. combined 20/16/6 Amp. of ISI marked and 4sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside capping, screwless connector for joints as per specification for :-On separate board. UsingModular accessories On separate board. Extra long-III |
| 24 | Same board switch & socket 16 Amp./S.S. combined 20/16/6 Amp. Using Modularaccessories |
| 25 | Supplying and fixing PVC casing and capping (double fold) ISImarked along with accessories on surface etc. as required -PVC casing and capping (double fold) 32 mm x 12mm |
| 26 | Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping of ISI marked suitable size etc. as required as per specification Using modular accessories. 2x2.5 Sq.mm. |
| 27 | Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping of ISI marked suitable size etc. as required as per specification Using modular accessories. 4x2.5 Sq.mm. |
| 28 | Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping of ISI marked suitable size etc. as required as per specification Using modular accessories. 6x2.5 Sq.mm. |
| 29 | Wiring for circuit wiring with PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping of ISI marked suitable size etc. as required as per specification Using modular accessories. 8x2.5 Sq.mm. |
| 30 | Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:- 1 Or 2 Module PVC box |
| 31 | Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:- 3 Module PVC box |
| 32 | Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:- 4 Module PVC box |
| 33 | Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:- 6 Module PVC box |
| 34 | Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:- 8/9 Module PVC box |
| 35 | Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:- 12Module PVC box |
| 36 | Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:- 16Module PVC box |
| 37 | Supplying and drawing single core PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing rigid PVC casing and capping/conduit in surface or concealed as per specification. 1 X 1.5 sq. mm. |
| 38 | Supplying and drawing single core PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing rigid PVC casing and capping/conduit in surface or concealed as per specification. 2 X 1.5 sq. mm. |
| 39 | Supplying and drawing single core PVC insulated cable FRLS with copper multi strand conductor ISI marked in existing rigid PVC casing and capping/conduit in surface or concealed as per specification. 2 X 4 sq. mm. |
| 40 | Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of \"C\" series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002&60947-2 but without enclosures :- MCB SP 6Amp to 32Amp 10kA rating (Single pole) |
| 41 | Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of \"C\" series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002&60947-2 but without enclosures :- MCB DP For 40Amp 10kA rating (Double pole) |
| 42 | Supply of ISI marked and accepted standard of miniature circuit breaker (MCB) of \"C\" series with short circuit indication, suitable for 240/415 Volts,50 Cycle, 10kA/15 kA Value AC supply conforming to IS : 8828 : 1996, IEC : 60898 :2002&60947-2 but without enclosures :- MCB TP For 40Amp 10kA rating (Triple pole) |
| 43 | Supply of approved make powder coated sheet steel encloser SPN MCB DB inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator)-12 Way double door IP 43 protection |
| 44 | Supplying of approved make TPN MCB DB metal double door IP 43 protection with provision for FP MCB/ Isolator/ RCCB/ RCBO as incomer and SP MCBs as outgoing inclusive of busbar, neutral bar, earth bar, connection copper wire not less than 16 sq.mm & two earth terminals etc. complete as per IS:13032 (exclusive of MCB & isolator):4 Way (4+12) |
| 45 | Supplying of approved make vertical TPN MCB DB metal double door IP 43 protection with provision for FP MCB/Isolator /RCCB/RCBO as incomer and SP/TP MCBs as outgoing inclusive of busbar, neutral bar, earth bar, & two earth terminals etc. complete as per IS:13032(exclusive of MCB & isolator). 4 Way (8+12) |
| 46 | Fixing of MCB/MCCB/Isolator in sheet steel enclosure as required as per accepted practice, including mounting on busbar and cable connection etc. complete (labour only). MCB/Isolator SP/DP |
| 47 | Fixing of MCB/MCCB/Isolator in sheet steel enclosure as required as per accepted practice, including mounting on busbar and cable connection etc. complete (labour only). MCB/MCCB Isolator TP/TPN/FP |
| 48 | Labour charges for fixing sheet steel enclosures, MCB DB surface mounting type, as per accepted practice on 25x25x 5 mm angle iron clamp, including supplying and fixing of clamp duly embedded in wall, cable connection etc. complete. For Item SOR no. 27.11.6 & 27.11.7; 27.12.5 ; 27.13.2 to 27.13.4 & 27.14.1 to 27.14.4 ; 27.15.1 to 27.15.4 |
| 49 | Labour charges for fixing sheet steel enclosure, MCB DB surface mounting type, as per accepted practice on 25x5mm flat iron clamp duly embedded in wall, cable connection etc. complete. For Item SOR no. 27.11.5 & 27.12.1 to 27.12.2 |
| 50 | Labour charges for fixing sheet steel enclosure, MCB DB surface mounting type, as per accepted practice on 25x5mm flat iron clamp duly embedded in wall, cable connection etc. complete. For Item SOR no. 27.12.3 to 27.12.4 & 27.13.1 |
| 51 | Supply and fixing as per specification call bell/buzzer ofapproved make with necessary materials complete. Ding dong bell |
| 52 | Supply and fixing as per specification call bell/buzzer ofapproved make with necessary materials complete. Remote/cordless bell |
| 53 | Supply and fixing as per specification Switch of approved make ISI marked with necessary material complete. Blank plate 1 module |
| 54 | Supply and fixing of approved make step type modularelectronic fan regulator including connection etc. as requiredon existing board 100 Watt(2 module) |
| 55 | Supplying, erection and testing of approved make electric Ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts including connections with all necessary material complete of approved as required confirming to IS :374/2019 with upto date amendments. Ceiling Fan (ISI marked)-1200 mm Sweep, with minimum air delivery 210 m³/min and service value ≥ 4.00 as per BEE.. |
| 56 | Supplying, erection and testing of approved make wall mounting fan oscillating type with base, blades, guard, speed regulator etc. AC 230-250 volts with connections and including raw bolt/anchor hole fastener etc. complete finished and as required.400 mm sweep |
| 57 | Supplying, erection and testing of approved make cabin fanoscillating type with base, blades, guard, speed regulator etc.AC 230-250 volts with connections and including raw bolt / anchor hole fastener etc. complete finished and as required. 300 mm sweep |
| 58 | Supplying, erection and testing of approved make \"Fresh air fan\" AC 230-250 volts with connection and including frame bolt/anchor hole fasteners etc. complete finished and as required. 300 mm sweep bush type |
| 59 | Supply and fixing Led tube rod comprising of LED tube with nonintegral/ integral driver, upto 6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with system efficacy> 100 lm/Watt. LED driver PF> 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. Tube light LED 1 X 20/22Watt, Integral i/c batten aluminium body,PC diffuser. |
| 60 | Supply and fixing of surface mounting type LED light fixture, LED of 1 to 3 Watt each assembled on single MCPCB, having color temp upto 6500K & having 50000 burning hrs. life with minimum @ L 70, system lumen output should be minimum with efficacy>100 lm/Watt. LED driver, PF> 0.95, THD < 20% & surge protection 4KV. The colour rendering index of LED light should be more than 70. Housing made of CRCA powder coated frame with glare free diffused polycarbonate cover. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. LED luminiare 2\" X 2\", 36Watt, color temp 3000-6500k as required. |
| 61 | Supply & Fixing of Decorative LED Street Light of 1 to 3 watt with each , system lumens output with Efficacy> =135lm/ W(@6500k), It\"s body made of Die cast aluminium using pressure die-casting process. Hole for coupling on pipes Ø 60 mm, for lateral installation. Silicon gasket enusures the IP protection. IP Rating - IP66. Power LED Module with high efficacy LED\"s on single Printed Circuit Board with metal core plate. Colour Rendering Index: Ra > 70. Electronic Power Supply for LED Module, which offers Protection against Short Circuit, Over- Voltage & Over- Current, with in-built surge protection upto 4kv (an additional surge protection device of 10kV also provided in-built the fixture). PF >0.95 and THD<10%. Lenscover in PC (IK09). Estimated LED Lifetime is L70 @ 1,00,000hours minimum. LM79-80 report from LED manufaturer should be submitted. Safety test report as per IEC 60598-2-3; IEC 60598-1 / IS 10322 IEC 61347 i/c connection wire , testing etc-Supporting Test Report from NABL approved lab, with 5 year on site warranty. 40Watt, Color Temp 3000-6500k as required |
| 62 | Supply & Fixing of Decorative LED Street Light of 1 to 3 watt with each , system lumens output with Efficacy> =135lm/ W(@6500k), It\"s body made of Die cast aluminium using pressure die-casting process. Hole for coupling on pipes Ø 60 mm, for lateral installation. Silicon gasket enusures the IP protection. IP Rating - IP66. Power LED Module with high efficacy LED\"s on single Printed Circuit Board with metal core plate. Colour Rendering Index: Ra > 70. Electronic Power Supply for LED Module, which offers Protection against Short Circuit, Over- Voltage & Over- Current, with in-built surge protection upto 4kv (an additional surge protection device of 10kV also provided in-built the fixture). PF >0.95 and THD<10%. Lenscover in PC (IK09). Estimated LED Lifetime is L70 @ 1,00,000hours minimum. LM79-80 report from LED manufaturer should be submitted. Safety test report as per IEC 60598-2-3; IEC 60598-1 / IS 10322 IEC 61347 i/c connection wire , testing etc-Supporting Test Report from NABL approved lab, with 5 year on site warranty. 60Watt, Color Temp 3000-6500k as required |
| 63 | Dismantling &shifting, installation, testing & commissioning of split air conditioning unit 1.0TR/1.5TR/2TRcapacity including indoor / outdoor unit complete as required within town. |
| 64 | Gas charging (R410A/Eco Friendly Green Gas) of window/split air conditioning unit including flushing of cooling & condensing units with nitrogen gas & rectification of leakage, replacement of filter, flair nut etc. if any. 1.5 TR |
| 65 | Earthing with G.I. earth pipe 4.5 metre long and 40 mm dia with masonry encloser in cement mortar, cover plate having locking arrangement on the top etc. (but without charcoal or coke and salt) complete as required |
| 66 | Add extra for using salt and charcoal/coke for pipe earth electrode as required including excavation & refilling. Excavation by making hole with auger |
| 67 | Earthing with G.I. earth plate 600mm X 600mm X 6mm thick including accessories and providing masonry encloser in cement mortar, cover plate having locking arrangement on the top and G.I. watering pipe 20mm dia 2.7 metre long etc. (but without charcoal or coke and salt) complete as required. |
| 68 | Add extra for using salt and charcoal/coke for G.I. plate or copper plate earth electrode as required including excavation in hard rock and refilling the pit with black soil. |
| 69 | Supply and laying 4.87mm 6 SWG G.I. wire at 0.5 metre below ground level as conductor earth electrode including jointing etc. as required. |
| 70 | Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor 3½ core armoured 25 sq. mm. 3½ core armoured 25 sq. mm |
| 71 | Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor 3½ core armoured 25 sq. mm. 4 core armoured 10 sq. mm. |
| 72 | Laying of one number armoured / unarmoured power cable 1.1KV grade of size not exceeding 25 sq. mm direct in ground including excavation in all soil/murrum /soft rock, sand ushioning, protective covering and refilling the pit etc. as required. |
| 73 | Supplying & fixing of fire extinguisher/refills as per IS specification. ABC type duly refilled 6 Kg & ready to use |
| 74 | Old Parts Aluminum |
| 75 | Old Parts Iron |
| 76 | Old Other Material |