Tender For Construction Of Arial Bunched Cable L.T. Network For Sector-33, Yea. Wc E M-02 - Supply & erection of Steel tubular pole with 1/6 over all length of pole grouted with cement concrete in 1:3:6 (1 cement : 3 coarse sand : 6 stone ballast) including plinthing of pole 30 cm above the ground level, plastering of plinth including excavation back filling etc. The rates includes all materials labour & T&P. etc. required for proper completion of work as per direction of E/I. YEIDA SOR-24410 SP-62, 12mtr. (Approx. wt. 264kg.) 2 S/F of cross arm made of 100X50X6 mm M.S. channel 2.5 mtr. long on poles with packing, piece, M.S. clamp, Nut bolts etc. complete in all respect, as directed by Engineer in charge. YEIDA SOR-30 3 Supply & fixing of MS rod for earthing with 2.5 m long, solid, 20 mm dia hot dipped galvanised MS rod buried till the top reaches 1.7 mts. Below the GL complete with bolts & nuts & GI earth wire 7/14. Complete in all respects as per direction of the Engineer-in-charge. YEIDA SOR-52 4 Painting of the electric pole with two coat of Al-paint over red oxide primer complete in all respect. UPPWD/2018 PS-634 5 Supply, delivery, assembly, installation, testing and commissioning of Outdoor type distribution transformer. 11/0.433 KV, 3 Phase, Double wound winding. Voltage ratio 11000/433-250 Volts, vector group Dyn 11. Air cooled with manually operated +5% and +10% off load Tap changer and complete with standard fitting & accessories as given in the specification and also confirming tolatest IS amendments : 1180 (LEVEL-1)with first filling of the oil complete as required. (This includes oil testing for dielectric strength, flash over test and filtration of transformer oil to be conducted in the event of unsatisfactory results of oil testing. (Kanohar Electrical, Vijay Electrical, Voltamp, Diamond, NGEF, Crompton, Alstom, BHEL, Raychem, make). YEIDA SOR-83 400 KVA Copper wound 6 Supply, erection, testing & commissioning of LT MSDB Panel 630A, ACB 4P, for input Supply (L&T/ABB) LED Indicators-(ESSBEE)Output: - with Alu. Bus bar 4P, 630A. Rust proof fabricated panel Base mounted, Outdoor type lockable panel Fabricated with GPSP 1.6/2.0 mm sheet & powder coated Size:- H 1300, W 800, D 900mmYEIDA SOR-97 7 Supply and burying of 600mmX600mmX6.0mm GI plate, vertically for earthing with its top atleast 3 mtr. Below ground level complete with 20mm dia GI pipe & funnel for watering and one earthing lead of one no.8 to 10 SWG GI wire in15mm dia G.I pipe and G.I wire up toswitch board ( from approm to switch board the cost of G.I pipe and G.I wire will be Extra) 30cm suuare C.l frame with hinged cover masonry housing alternate layers ofcharcoal/coke & salt atleast 150 mm thick all-around etc. as per direction of Engineer-incharge complete in all respects as per drawing (this will apply for earthing of poles also). UPPWD/2018 PS-702 8 S/L of 32mmX6mm GIstrip from earth electrode directly in the ground as required complete in all respect. UPPWD/2018 PS-717 9 Supply & laying of aluminium conductor, XLPE insulated, armoured served, sheathed cable 1100 V grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the E/I, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. [CCI (Mumbai/Nasik), Fort Gloster (Kolkata), Asian (Thane/Silvasa), Universal (Satna), Nicco (Kolkata/Baripara), ICL (Rajpura), Diamond, Havells make] & for small works upto value of cable for Rs. 25.0 Lacs Kalinga (Gold), Suraj, Delton, Grandly & Polycab make can be used) complete in all respect as per the directions of the Engineer-in-chargePWD-2018/PS No-501 3.5Cx150 sqm. 10 Supply, delivery, testing, laying of Al. conductor XLPE insulated 1100V grade Arial Bunched Cable with Messenger wire as below on pole complete in all respect. (CCI, Gloster, Asian, Universal, NICCO, ICL, Diamond, Havells, Kalinga, Suraj, Delton Grandley & Polycab, KEI make) Complete in all respect, as directed by Engineer in charge. As per the directions of the Engineer-in-charge. YEIDA SOR-963CX150 Sqmm. + 1CX120 Sqmm+16 Sq mm. Massanger 11 Supply, delivery, testing, laying of Al. conductor XLPE insulated 1100V grade Arial Bunched Cable with Messenger wire as below on pole complete in all respect. (CCI, Gloster, Asian, Universal, NICCO, ICL, Diamond, Havells, Kalinga, Suraj, Delton Grandley & Polycab, KEI make) Complete in all respect, as directed by Engineer in charge. As per the directions of the Engineer-in-charge. YEIDA SOR-763CX50 Sqmm. + 1CX25 Sqmm+35 Sq mm. Massanger 12 S/F of 150Sqmm to 16Sqmm L.T ABC Connector on Pole complete in all respect, as directed by Engineer in charge. YEIDA SOR-36 13 S/F of palm or pin type copper tin plated cable socket (Lug) to the cable leads, insulating with tape & making connections etc. complete in all respects as per the directions of the Engineer-in-charge. UPPWD/2018 PS-504 150 Sqmm. 14 S/F of palm or pin type copper tin plated cable socket (Lug) to the cable leads, insulating with tape & making connections etc. complete in all respects as per the directions of the Engineer-in-charge. UPPWD/2018 PS-504 50 Sqmm. 15 S/F of G.I Pipe 150MM dia B class Zindal/tata make including required material T&P etc. Complete in all respect, as directed by Engineer in charge. As per the directions of the Engineer-in-charge. YEIDA SOR-65 16 S/E of ‘D’ clamps 50X6mm. flat iron on steel tubular pole / steel rail pole with bolts, nuts etc complete in all respect including with aluminium paint. UPPWD/2018 PS-623 17 Supply & fixing of L.T. Junction box on pole suitable for out door type operation of size 388x304x170 mm made of 3.0mm CRCA sheet complete in all respect, as directed by Engineer in charge. YEIDA SOR-94 18 S/L of 160mm dia. DWC pipe for drawing of power cable across the road by drilling of 190mm dia. at 1mtr. Below the road level the work should be done by manual Trenchless method. Complete in all respect per direction of Engineer-in-charge. YEIDA SOR-14 19 S/F of HDPE. pipe 200mm dia PE-63/PN-4 including required material, T&P etc. complete in all respect, as directed by Engineer in chargeYEIDA SOR-19 20 S/F of PG clamp for 3 bolt size 3X5/2 bolt connected Dog to Dog ACSR conductor on pole (Jaishree, BHEL,RR, Hindustan, Yamuna, AD, make) Complete in all respect, as directed by Engineer in charge. YEIDA SOR-77 21 S/F of 11KV Polymeric Disc with Gun fittings on cross arms/clamps fixed on poles including all Nut, bolts & washer etc. (Jaishree, BHEL,RR, Hindustan, Yamuna, AD, make) Complete in all respect, as directed by Engineer in charge. YEIDA SOR-79 22 S/F of 11 KV Polymeric pin insulator with pin on poles or anywhere specified including bolts to fasten on pole cap/cross arm with the poles.(Jaishree, BHEL,RR, Hindustan, Yamuna, AD, make) Complete in all respect, as directed by Engineer in charge. YEIDA SOR-78 23 S/F of 0.3mtr. long top channel for pin made of 100X50X6 mm M.S. channel with M.S. clamp packing box nut bolt etc. complete in all respect, as directed by Engineer in charge YEIDA SOR-32 24 S/F of cross arm made of 100X50X6 mm M.S. channel 1.15 mtr. long with M.S. clamp packing piece Nut bolts etc. complete in all respect, as directed by Engineer in charge YEIDA SOR-31 25 Supply & Erection of End Clamp (J Hook) Complete in all respect, as directed by Engineer in charge. YEIDA SOR-92 26 Supply & erection of screw tightener complete in all respect, as directed by Engineer in charge. YEIDA SOR-37 27 Supply & fixing of stay insulator with stay wire complete in all respect, as directed by Engineer in charge. YEIDA SOR-38 28 Supply & fixing of Suspension clamp with insulated suitable ABC arial bunched conductor complete in all respect, as directed by Engineer in charge.YEIDA SOR-93 29 S/E of stay set at least 3.5 mtr away from the pole complete with galvanized 19mm dia x 1.800 mtr long stay rod. 30cmx30cmx6.3mm anchor plate thimble stay clamps, stay insulator 19mmx600mm double screw tightener. 7/4.00 mm G.I. stay wire etc. in1:3:6 cement concrete in all respect. UPPWD/2018 PS-630. 30 Supply andfixing dangerboardfabricated from10gaugeM.S. Sheet as per I.E. Rules.UPPWD/2018 PS-1109 31 S/F of 11 KV TPMO set of ‘Relco’ make or equivalent with insulators and other accessories required for proper completion of work.as per the directions of the Engineer-in-charge YEIDA SOR-56 32 S/F of 11 KV Drop-out type fuse set channel type of ‘Relco’ or equivalent make with insulators and other accessories required for proper completion of work.as per the directions of the Engineer-in-charge YEIDA SOR-57 33 Supply, Sagging, tensioning, jointing and bending of suitable size ACSR conductor conferming to I.S. specification including cost of aluminium wire and jointing sleeve required. The rates includes cost of material, labour, T&P etc. required for proper completion of work as per the directions of the Engineer-in-charge. PWD-2018 P.S.-627Dogconductor. 34 Supply, Installation, Testing & Commissioning of 11 KV Out door type cable termination kit of 3 core cable with cable termination at the panel & transformer complete in all respect as required for proper completion of work as per direction of Engineer-in-charge. (Make Raychem/C.C.I./Frontec). YEIDA SOR-5