Tggenco - Nshes - Supply Of Certain Measuring Instruments, 37 Kw/50 Hp Motors, Limit Switches And Cam Rotary Switches Etc At Amrplis, Nshes, Nagarjunasagar.-1. FLUKE 17B+ : DIGITAL Multimeter including Test leads with caps, Thermocouple Temperature probe (17B+) , 2 AA batteries & User Manual. Display (LCD): 4000 counts, updates 3/sec AC/DC volts (40 Hz to 500Hz) 4.000 V, 40.00 V,400.0 V,1000 VAC/DC milli volts: 400.0 mV, Diode test2 2.000 V Resistance (Ohms): 400.0 Ohm, 4.000 k Ohm, 40.00 k Ohm, 400.0 k Ohm, 4.000 M Ohm, 40.00 M Ohm Capacitance³ 40.00 nF, 400 nF, 4.000μF, 40.00μF, 400.0μF, 1000μF AC/DC current A: 4.000 A, 10.00 A Temperature: 50°C-400 °C, 0°C- 50 °C, -55 °C- 0 °C IP rating: IP 40 Safety: IEC 61010-1, IEC6 1010-2-030 CAT III 600 V, CAT II 1000 V, Pollution Degree 2 2. FLUKE 773mA Process Clamp meter: along with Soft carrying case, Test leads, Alligator clips, Hanging strap and User’s Manual and Calibration certificate Traceable to National Standards The Meter Shall be capable to Measure 4-20 m A signals without breaking the loop and to measure m A signals with in circuit measurement, operating temperature -10°C to 50°C storage temperature -25°C to 60°C source DC voltage to test input devices that accept a 1 to 5 volt or 0 to 10 volt signal, mA in/out: shall also be capable to simultaneously measure the mA signal with the clamp and source a mA signal DC voltage measurement to verify 24 V power supplies or voltage I/O signals. 3. FUSE, FAST, 11A, 1000V for Fluke multimeter 4. FUSE, FAST, 440mA, 1000V for Fluke multimeter 5. INSULATION TESTER WITH 1KV INSULATION RESISTANCE INSULATION TEST RANGE 0.1 OHMS TO 50 MOHMS Make: Fluke 6. INFRARED THERMOMETER GUN, Make: Fluke Temperature Range -500 C to + 5000C along with Calibration Certificate from NABL approved Lab 7. DIGITAL VIBRATION METER Make: IRD Meachanalysis, Model: IRD811D (811D/811 D) Meter cum Spike Energy Detector with Standard Accessories SKU : IRD811D Vibration Meter shall be able to measure Vibration Amplitude in terms of Displacement in microns peak-peak, Velocity in mm/sec RMS and Acceleration in g peak. It shall also able to help assess Anti-Friction Bearing Condition by measurement of Spike Energy in g SE 8. IRD Portable Calibrator For IRD306DP, IRD811 and IRD811D Vibration Meters, SKU: IRD CAL 9. FLUKE369 FC Leakage Current Clamp Meter along with Soft case, Manual, 2AA Batteries and Calibration certificate Traceable to National Standards AC ampere range 3 mA, 30 mA, 300 mA, 3 A, 30 A, 60 A. Range selection mA, A: manual selection 3 mA, 30 mA, 300 mA: automatic selection 3 A, 30 A, 60 A: automatic selection Range/Resolution 3 mA[l ]/0.001 mA, 30 mA/0.01 mA, 300 mA/0.1 mA, 3 A/0.00 1 A, 30 A/0.01 A, 60 A/0.1 A Accuracy - filter activated (40 to 70 Hz), filter off(40 to 1 kHz)[2]: 3 mA to 30 A Accuracy: 1.5 % + 5 digits 60 A Accuracy:2 % + 5 digits Display (LCD) Digital readout:3300 count Display refresh rate: 4 times/sec Maximum conductor diameter: 61 mm 10. POSITION LIMIT SWITCH TYPE: ANGULAR ROLLER LEVER 2NO+1NC METAL ENCLOSURE,SLOW ACTION,56MM TYPE:3SE5122-OPAOO-8K Make:Siemens 11. 37KW/50HP 3-Phase, Delta Connection, 1470 RPM, Current 83.5A, 50HZ, Frame 225 SM Foot Motor. 12. 16A/250V DC, 4 Positions, 12 Pole, Cam Rotory Switch