| 1 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, excluding fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed by Engr in Charge. |
| 2 | M & L for point wiring using approved colour coding as per IS by using FRLS PVC insulated 1.5 Sqmm multistranded,1100 volt grade copper conductor cable unsheathed type, alongwith 1.5 Sqmm FRLS PVC insulatedstranded copper conductor cable for continous earthing in & incl PVC casing & caping with accessories having ISI mark fixed on wall surfaces / ceilingincluding provision of suitable gang box for fixing switches, sockets, regularors, etc. for one light/fan/bell point controlled by one switch complete all as specified and directed by Engr in Charge |
| 3 | All as per item No 2 here-in-before but for one multipin socket outlet 5 Amp onthe independent board complete all as specified and directed by Engr in Charge. |
| 4 | All as per item No 2 here-in-before but for one multipin socket outlet 5 Amp on the same board with other switches complete all as specified and directed by Engr in Charge |
| 5 | All as per item No 2 here-in-before but for one multipin socket outlet 15 Amp, independent board complete all as specified and directed by Engr in Charge |
| 6 | S & Fin Repair ofsocket6 A 250V AC universal polycarbonate complete all as specified and directed by Engr in Charge. |
| 7 | S & Fin Repair ofswitch piano flush button type 5 amps single pole one way complete all as specified and directed. |
| 8 | S & Fin Repair ofBell push single pole one way complete all as specified and directed. |
| 9 | S & Fin Repair ofswitch piano flush button type 15 amps single pole one way complete all as specified and directed. |
| 10 | S & Fin Repair ofSocket outlet multipurpose 2 in 1, 5 and 15 Amps complete all as specified and directed. |
| 11 | S & Fin Repair ofceiling fan regulator step type for 1200/1400 mm sweep ceiling fan complete all as specified and directed. |
| 12 | M&L in repair louver shutter of exhaust fan suitable for 300 mm size at the height from 3mtr to 30 mtr heightmaking good surface of distubed area complete all as specified & directed.(Note: Contractor shall arrange suitable T&P including necessary form work, scoffolding and safety measures to make it functional complete all as specified and directed) |
| 13 | S&F in replacement MCB SP 6-32 Amps,10KA,\"C\" series complete all as specified and as directed. |
| 14 | S&F in replacement MCB DP 32 /40 Amps, 10KA, 240V, \"C\" series complete all as specified and as directed. |
| 15 | S&F in replacement MCB DP 63 Amps, 10KA, 240V, \"C\" series complete all as specified and as directed. |
| 16 | S&Fof factory made epoxy polyester powder coated distribution board SP & N 8 way fabricated from minimum 1.6 mm thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, eath bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and6 SP MCBs as outgoings complete all as specified and conforming to IS: 8623 alongwith cable end box for aboveDB all as specified and directed.NOTE:- (a) MCBs shall be measured and paid separately.(b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch. |
| 17 | All as per item No 16 here-in-before but 4 way complete all as specified and directed by Engr in Charge |
| 18 | M & L for Earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, burieddirectly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR Part-1 2009, connected to earthing test point, earth lead protected by medium grade 15 mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1:2:4 B-1 ( including excavation and earth work, disposal of surplus soil to a distance not exc. 50 Mtrs) all as specified and shown on plate No 5 of SSR – Part I 1991.Note:-(a). PCC pit shall be provided at list 500 mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipe and fittings, junction, elbow etc shall be deemed to be included in the unit rate.(b). RCC pit cover shall be of pre-castRCC 1:2:4, type B-1, 80 mm thick reinforced with XPM weighing not less than 4 Kg/ Sq m in lieu of cast iron cover all as specified or indicated including testing on completion all as specified and directed. |
| 19 | Supply, laying and drawing submain wiring inCasing capingon walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6.0 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including taking out old wiring connection height from 3mtr to 30 mtr heightmaking good surface of distubed area complete all as specifiedand directed.Note: Contractor shall arrange suitable T&P including necessary form work, scoffolding and safety measures to make it functional complete all as specified and directed. |
| 20 | S&F in repaircall bell electric 240 volts, AC supply, Ding Dong type complete all as specified and as directed. |
| 21 | S&F in repaircall bell electric 240 volts, AC supply & codeless Ding Dong type complete all as specified and as directed. |
| 22 | S&F replacement of lamp holder pvc/polycarbonate type with back plate complete all as specified and directed. |
| 23 | S&F replacement of ceiling rose3 phsae pvc/polycarbonate isolated body complete all as specified and directed. |
| 24 | Supply & Fixing in replacement of MS down rod 300/450 mm for fixing of ceiling fan complete all as specified and directed |
| 25 | Supply & Fixing in replacement MS clamp with rubber reel, nuts, bolts, split pin etc suitable for 1200/1400 mm swwep ceiling fan complete all as specified and as directed. |
| 26 | Supply & Fixing in replacementPVC connection with brass nippleof size 15 mm x 600 mm long with ISI marked suitable for hot and cold water of 25 lit capacity geyser as hot and cold connection complete all as specified and directed. |
| 27 | Supply & Fixing in replacement of inner shellStainless steel bodysuitable for Bajaj or as per site requirement as directed by JE/Engr-in-chargeGeyser of 25 Ltr capacity complete all as specified and directed. |
| 28 | Supply & Fixing in replacementof Copper Heating Element 1500 /2000watt including assenbly suitablefor Bajaj or as per site requirement as directed by Engr-in-chargeGeyser of 25 Ltr capacity complete all as specified and directed. |
| 29 | Supply & Fixing in replacementof thermostat suitable to work at water temperature 30° to 75° C electric cut upfor Bajaj or as per site requirement as directed by Engr-in-chargeGeyser of 25 Ltr capacity complete all as specified and directed. |
| 30 | Supply & Fixing in replacementof Indicating lamp (red/green/yellow) complete suitablefor Bajaj or as per site requirement as directed by Engr-in-chargeGeyser of 25 Ltr capacity complete all as specified and directed. |
| 31 | Supply & Fixing in replacement15A plug top and connection complete all as specified and as directed |
| 32 | Supply & Fixing in replacementSS combined 15 ampwith Box complete all as specified and directed by Engr-in-charge |
| 33 | Supply & Fixing in replacement SS combined 5 ampwith Box complete all as specified and directed by Engr-in-charge |
| 34 | Supply & Fixing in replacementPVC flexible two core multistranded FRLS copper 1.5 sqmmsize complete all as specified and directed |
| 35 | Supply & Fixing in replacementthree core multistranded FRLS copper conductor 2.5 sqmmsize complete all as specified and directed. |
| 36 | Supply & Fixing in replacementSinglecore multistranded FRLS copper conductor 2.5 sqmmsize complete all as specified and directed. |
| 37 | Supply & Fixing in replacementSinglecore multistranded FRLS copper conductor 1.5 sqmmsize complete all as specified and directed. |
| 38 | Supply only Singlecore copper conductor multistranded FRLS 4.0 sqmmsize complete all as specified and directed. |
| 39 | Supply & Fixing in replacementSinglecore multistranded FRLScopper conductor 6.0 sqmmsize complete all as specified and directed. |
| 40 | Supply & Fixing in replacement LED LAMP 9 Wattspin type including taking any type of lamp complete all as specfied and directed |
| 41 | Supply & Fixing in replacement LED LAMP 9 Wattspin type minimum 4 hrs battery backup rechargeable led bulb including taking any type of lamp complete all as specified and directed by Engr in Charge |
| 42 | Supply & Fixing in replacementtube light fittings 20 watt 4 ft 6500k including taking any type of lamp complete all as specified and directed by Engr in Charge |
| 43 | Supply & Fixing in replacementtube light fittings 10 watt 2 ftincluding taking any type of lamp complete all as specified and directed by Engr in Charge |
| 44 | Supply & Fixing in replacementBulk head 10 watt 6500kincluding taking any type of lamp complete all as specified and directed by Engr in Charge |
| 45 | Supply & Fixing in replacement ceiling fan capacitor for 1200/1400 mm sweep 2.5 mfd complete all as specified and directed by Engr in Charge |
| 46 | Taking down ceiling/exhaust fan, ceiling cable end, dismantling blades and removing fan and blades & deposited to MESstore and refixing the same complete all as specified and directed by Engr in Charge |
| 47 | M&L for rewinding of ceiling fans of any type and make complete with super enamelled copper wire (HTP) in the workshop wire with appropriate gauge suiatble for existing make including necessary lathingmon shaft, capacitor,Bearing,both sides of rewinding covered with high quality varnish, replacement of ball bearing of SKF/NBC make and provisions of new nuts and pins for 1200/1400 mm sweep including taking out old burnt wind of copper/aluminium complete all as specified and directed. |
| 48 | Supply & Fixing in replacementcanopy for ceiling fans (Set of two) complete all as specified and as directed. |
| 49 | M&L for rewinding exhaust fan of 450 mmsweep of any type & make complete with super enamelled copper wire (HTP) in the workshop including taking out old burnt wind copper/aluminium wire with appropriate gauge for suitable existing make, both sides of rewinding locked with high quantity varnish complete including replacement ofball bearing of SKF/NBC make and provisions of new nuts pin complete all as specified & directed. |
| 50 | M&L for rewinding exhaust fan of 300 mmsweep of any type & make complete with super enamelled copper wire (HTP) in the workshop including taking out old burnt wind copper/aluminium wire with appropriate gauge for suitable existing make, both sides of rewinding locked with high quantity varnish complete including replacement ofball bearing of SKF/NBC make and provisions of new nuts pin complete all as specified & directed. |
| 51 | S&Fcopper winding motor of Fresh air fan for sweep 250mm/300mm as per site requirement complete all as specified & directed. |
| 52 | S&F copper winding motor of exhaust fan sweep 250mm/300mm as per site requirement complete all as specified & directed. |
| 53 | S&F copper winding motor of exhaust fan sweep 450 mm as per site requirement complete all as specified & directed. |
| 54 | Supply & Fixing in replacement3 mm thick hylum sheet 9x11 including cutting of suitable for switch/socket/regulator complete all as specified and directed. |
| 55 | Supply & Fixing in replacement 3 mm thick hylum sheet 8x5including cutting of suitable for switch/socket complete all as specified and directed. |
| 56 | Supply & Fixing in replacement3 mm thick hylum sheet 5x5 completeincluding cutting of suitable for switch/socket complete all as specified and directed by Engr in Charge |
| 57 | Supply & Fixing in replacementmetal thick sunken box 4x4 including brass scews and cup complete all as specified and directed. |
| 58 | Supply only metal thick sunken box 8x10 including brass scews and cup complete all as specified and directed. |
| 59 | Supply only metal thick sunken box 7x4 including brass scews and cup complete all as specified and directed. |
| 60 | M& L for openingof BLDC ceiling fanBajaj make or as site requirement 1200 mm sweep including replacement of PCB card and repair the BLDC ceiling fan and deposit to the MES yard with complete running position all as specified and directed. |
| 61 | S & F in replacement of Modular switch 1 way 6 Amp, 1 module complete as per site requirement all as specified and directed. |
| 62 | S & F in replacement of Modular socket 6 Amp, 2 & 3 pin combined, 2 module complete as per site reuirementall as specified and directed. |
| 63 | S & F in replacement of Modular switch 1 way 16 Amp, 1 module complete as per site requirementall as specified and directed. |
| 64 | S & F in replacement of Modular socket 16Amp, 2&3 pin combined, 2 module complete as per site requirementall as specified and directed. |
| 65 | S & F in replacement of Modular fan regulator, 120W-2 module, complete as per site requirementall as specified and directed. |
| 66 | S & F in replacement of Modular cover plate with frame 3 module, complete as per site requirement all as specified and directed. |
| 67 | S & F in replacement of Modular cover plate with frame 6 module, complete as per site requirement complete all as specified and directed by Engr in Charge |
| 68 | S& F in replacement of 3 way modular PVC box complete as per site requirementcomplete all as specified and directed by Engr in Charge |
| 69 | Schedule of Credit |