}

Tender For Proposed Eco Tourism Development Of Nature Park At District Chitrakoot (U.P) - Civilwork 3 Earthworkinexcavationbymechanicalmeans (Hydraulicexcavator)/Manualmeansoverareas (Exceeding 30 Cm In Depth, 1.5 M In Width As Wellas10sqmonplan)Includi, chitrakoot-Uttar Pradesh

Uttar Pradesh Projects Corporation Limited has published Tender For Proposed Eco Tourism Development Of Nature Park At District Chitrakoot (U.P) - Civilwork 3 Earthworkinexcavationbymechanicalmeans (Hydraulicexcavator)/Manualmeansoverareas (Exceeding 30 Cm In Depth, 1.5 M In Width As Wellas10sqmonplan)Includi. Submission Date for this Tender is 19-04-2025. Gardening Tenders in chitrakoot Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

48508373
Tender For Proposed Eco Tourism Development Of Nature Park At District Chitrakoot (U.P) - Civilwork 3 Earthworkinexcavationbymechanicalmeans (Hydraulicexcavator)/Manualmeansoverareas (Exceeding 30 Cm In Depth, 1.5 M In Width As Wellas10sqmonplan)Includi
Open Tender
NCB
Uttar Pradesh
Chitrakoot
19-04-2025

Tender Documents

Tender Details

Tender For Proposed Eco Tourism Development Of Nature Park At District Chitrakoot (U.P) - CIVILWORK 3 Earthworkinexcavationbymechanicalmeans (Hydraulicexcavator)/manualmeansoverareas (exceeding 30 cm in depth, 1.5 m in width as wellas10sqmonplan)includinggettingoutand disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in_x005fcharge 4 Providingandlayinginpositioncementconcreteof specifiedgradeexcludingthecostofcanteringand shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 5 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural so 6 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 7 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in : Cement mortar 1:4 (1 cement : 4 coarse sand) 8 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement : 4 coarse sand) 9 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 10 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints finished flush. Red sand stone 11 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 12 20 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 13 Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) 14 P/F Mildsteel orironinplain work suchas reinforced concrete or reinforced,brick work(whennotincluded in over all rates ) wrought to required shape as necessaryincludingbendingforpropercompletionof the work and including supply of steel its wastage bend hooksandauthorisedoverlappingshallbemeasured up to floor two level. 15 Stone work (machine cut edges) for all lining etc. (veneer work) up to 10 meter height, backing filled with grout of average 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately): Gang saw cut stone 30mm thick Red sand stone 16 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. 17 Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases. 18 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.20 mm M.S. laths with 1.20 mm thick top cover 19 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 20 Providing and fixing to existing door frames. 21 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 22 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 23 With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30 24 With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 25 Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge. 26 External Electrification 27 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 28 25 mm 29 32 mm 30 40 mm 31 50 mm 32 Supplying and drawing following sizes of FR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 33 2 x 1.5 sq. mm 34 4 x 1.5 sq. mm 35 4 x 2.5 sq. mm 36 4 x 4 sq. mm 37 3 x 6 sq. mm 38 4 x 6 sq. mm 39 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 40 6 way, Double door 41 8 way, Double door 42 12 way, Double door 43 16 way, Double door 44 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 45 4 way (4 + 12), Double door 46 6 way (4 + 18), Double door 47 8 way (4 + 24), Double door 48 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 49 Single pole 50 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 51 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 52 40 amps 53 63 amps 54 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-In charge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 55 10 sq. mm 4 core 56 16 sq. mm 4 core 57 25 sq. mm 3-1/2 core 58 35 sq. mm 3-1/2 core 59 Supply and fixing of brass nickel plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-In charge. 60 10 sq. mm 4 core 61 16 sq. mm 4 core 62 25 sq. mm 3-1/2 core 63 35 sq. mm 3-1/2 core 64 Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-In charge. 65 10 sq. mm 66 16 sq. mm 67 25 sq. mm 68 35 sq. mm 69 Supply & fixing of 8 mtr GI Octagonal Pole of approved make (top die 70mm, Bottom die 155 mm and base plate 12mm thick) having 3mm thickness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P complete in all respect. 70 Supply & fixing of 16 mtr High mast shaft of approved make with rising system hot dip galvanized inside & out side dip, heaving pole sheet thickness 3 mm. Top die minimum 150 mm, Bottom die 360 mm base plate 32 mm thick suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 6 to 12 luminaries & its control gear boxes 1.5 HP power tool motor, 3 point suspension system with steel wire rope 6 mm die, double drum winch, including making suitable foundation as per manufacture drawing/ site reuiment along with foundation bolts nuts, washers, anchor plates etc. complete in all respect. 71 Supply and burying earth electrode for lighting conductor of 900mm x 900mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm die G.I. pipe for watering funnel, 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick all around etc. as per directions of Engineering-charge complete in all respect. 72 Supply and burying earth electrode for lighting conductor of 600mm x 600mm x 3mm Copper plate vertically with its top at least 3 metres below ground level complete with 20mm die G.I. pipe for watering funnel, 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick all around etc. as per directions of Engineer-in-charge complete in all respect. 73 Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry housing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. 74 Supply & eraction of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entries Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnetic release)Switches Complete and instrument chamber etc. Complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc.) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic aluminium bus bars as per IS8623 or above insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with detachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounding of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.Incoming100 Amp MCCB -1 NoOutgoing32 Amp. MCCB-3 Nos.(ii) Cat. B. Panel Cubicle Type 75 Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. 40 A TPN 76 Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 30Watt. to 40 Watt. Confirming to IP 66 protection complete in all respect. CAT- AAA 77 Supply and fixingof recess/Surface/Pendent mountinground 6 Watt 8 Watt LED Down LighterhavingPowder coated die cast aluminium housingwith heat sink, diffuser/Reflector and driver set complete in all respect. CAT-AA 78 Supply and fixing of 3 Watt LED Path / Walkover luminaire having powder coated die cast aluminium body with drive set . Confirming to IP 65 Protection complete in all respect. CAT-AAA 79 Supply and fixingof decorative 40 to 45 Watt LED Post top indirect lightluminairehavingPressure die cast aluminiumbody and Clear glass with driver set confirmingto IP 65 and above protection complete in all respect. CAT-AAA 80 Supply and fixing of 3 Watt to 6 Watt LED Spot/Spike light luminaire Confirming to IP 66 Protection complete in all respect. CAT-AAA 81 Supply and fixing of decorative 8 to 16 Watt LED bollard luminaire with driver set confirming to IP 65 and above protection complete in all respect CAT-AAA 82 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 70 to 90 Watt. Confirming to IP 65 protection complete in all respect. CAT-AAA 83 Supply, Installation, Testing and Commissioning of LED RGB/RGBW Linear Wall Washer luminaire for Facade lighting with aluminium extruded housing, of following wattage. Luminaire shall be capable of producing dynamic colour changing light with 16 million colours by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100 to 270 V AC, 50 Hz, power factor > 0.9 . Fixture shall be suitable to operate at ambient temperature range of -10°C to +50°C and shall be IP 65 and IK06 rated. Lifetime should be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. 84 40 W 85 25 W 86 Supplying, Installation, testing and commissioning of 33 kv/.433 kv substation or 11kv/0.433 kv substation equipment comprising HT panel, transformers, HT cable, bus trunking from transformer to LT panel, LT panels, automatic power factor correction panel, active harmonic filters, TVSS (transient voltage suppression system), SPD (surge protection system), essential panel, earthing, required inter-connections, substation safety equipments including LT cabling from substation fed by the substation. 87 Supplying, installation, testing and commissioning of silent type DG sets, AMF panel, bus ducting/cables from DG sets to essential panel, synchronizing panel where required, DG set enclosure room sound insulation/ventilation/smoke exhaust as requird, earthing of DG set system, control cabling, fuel tank/ piping, DG set exhaust piping/exhaust chimney as per cpcb norms, civil works connected with DG sets including foundation as required 88 EXTERNAL SEWERAGE 89 Excavating trenches by mechanical / manual means of required width for pipes, cables, etc. including excavation for sockets and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm dia 90 Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, depth upto 1.5 m, including getting out the excavated soil, and then returning soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50 m. Ordinary Rock Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm dia 91 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 150mm diameter 92 Providing, laying cement concrete 1:5:10 (1 Cement : 5 Coarse sand : 10 graded stone aggregate 40mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 150 mm diameter 93 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame 300 X 300 mm size (inside) the weight of cover to be not less than 4.50Kg and frame to be not less than 2.70 Kg as per standard design 100 X 100 mm size P type With Sewer bricks Conforming to IS : 4885 94 Providing and laying non pressure NP-2 class (light duty R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 95 150 m dia R.C.C. pipe 96 250 m dia R.C.C. pipe 97 Constructing brick masonry circular type manhole 0.91m internal dia at bottom and 0.56m dia at in cement mortar 1:4 (1 cement :4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement all complete as per standard design 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182kg., fixed in cement concrete1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including centring shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately ) 98 With Sewer bricks conforming to IS : 4885 99 With Sewer bricks conforming IS : 4885 100 Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1 cement :3 coarse sand :6 graded stone aggregate 20 mm nominal size ) complete as per design. 101 WATER SUPPLY (PLUMBINGWORK) 102 Providing and laying and testing S&S centrifugally cast Ductile Iron double chamber Class K-9 pressure pipes conforming to IS : 8329:2000 with restrained joints (bolt less), all complete. 100 mm nominal dia pipe 103 Providing and laying Class K-12 Ductile Iron double chamber restrained joint (bolt less) specials such as tees, bends, collars, tapers and caps etc. conforming to IS : 9523 including testing of joints all complete. up to 600 mm dia 104 Providing and fixing C.I. double acting air valve of approved quality with bolts, nuts, rubber insertions etc. Complete (the tail pieces, tappers etc. if required will be paid separately) 100 mm dia 105 Providing and fixing C.I sluice valve (with cap) complete with bolts, nuts, rubber insertions etc. (the tail piece if require will be paid separately) 100 dia Class II 106 Constructing masonry Chamber 90x90x100 cm, inside with 75 class designation brick work in cement mortar 1:5 ( 1 cement :5 fine sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 ( 1 cement :5 fine sand:10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 ( 1 cement :3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of designation 7.5 107 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal Stability for hot & cold water supply, including all CPVC plain & brass threaded fittings this includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge. 108 25 mm nominal bore 109 32 mm nominal bore 110 40 mm nominal bore 111 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. (external work) 112 50mm dia. nominal bore 113 65mm dia. nominal bore 114 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete. 50 to 80 mm nominal bore 115 Providing and fixing gun metalnon- return valve of approvedquality (screwed end ) 116 Horizontal 117 Vertical 118 STORM WATER DRAIN 119 Excavating trenches by mechanical / manual means of required width for pipes, cables, etc. including excavation for sockets and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm dia 120 Providing and laying non pressure NP-2 class (light duty R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 250 m dia R.C.C. pipe 121 Constructing brick masonry circular type manhole 0.91m internal dia at bottom and 0.56m dia at in cement mortar 1:4 (1 cement :4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement all complete as per standard design 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182kg., fixed in cement concrete1:2:4(1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including centring shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately ) With common burnt clay F.P.S. (non modular) bricks with class designation 7.5 122 Extra depth for circular type manhole 0.91m internal dia (at bottom) with beyond 0.91m to 1.67m With common burnt clay F.P.S. (non modular) bricks with class designation 7.5 123 Constructing brick masonry circular manhole 1.22m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand) inside cement plaster 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement foundation concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement all complete as per standard design 1.68 m deep with SFRC Cover and frame (heavy duty HD-20 grade designation) 560mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including centring shuttering all complete. (Excavation, foot rests and 12 mm thick cement plaster at the external surface shall be paid for separately) With common burnt clay F.P.S. (non modular) bricks with class designation 7.5 124 Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1 cement :3 coarse sand :6 graded stone aggregate 20 mm nominal size ) complete as per design. 125 RAIN WATER HARVESTING 126 BORING 127 Boring / drilling bore well of required dia for casing / strainer pipe, by suitable method prescribed in IS : 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants, & machineries required for the job, all complete as per direction of engineer-in-charge, upto 90 meter depth below ground level. All types of soil 300 mm dia 128 Supply, assembling, lowering and fixing in vertical positionin bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS:12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia 129 Supply, assembling, lowering and fixing in vertical positionin bore well, unplasticized PVC medium well screen (RMS) pipe with rib, conforming to IS:12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.100 mm nominal size dia 130 Gravel packing in tubewell constructionin accordance with IS:4097, including providing gravel fine / medium /coarse, in required grading & sizes as per actual requirment, all complete as per direction of Engineer-in-charge 131 RWH PIT 132 Size :- Length = 10.00 M. Width = 500M Total Depth =4.00M 133 Earth work in excavation over areas including disposalofexcavatedearth,leadupto50m, disposed earth to be levelled and neatly dressed. 134 In all kind of soil upto 1.5m depth 135 In all kind of soil upto 1.5m to 3.0m. depth 136 In all kind of soil upto 3.0m to 4.5m. depth 137 Providingandlayingofcementconcretein base excluding the cost of centring and shutteringby1:2:4(1cement:2coarse sand :4 gradded stone aggregae 20mm nominal size) 138 Brick work with brick of class designation 150 in foundationand plinth in cement mortar (1 cement : 4 coarse sand) 139 Reinforcementcementconcreteworkin RCC culvert slab with 1:1.5:3 (1 cement : 1.5 coarsesandand3graddedstoneaggregate of20mmnominalsize)includingcentering and shuttering and reinforcement. 140 TMTFe-500orironinplainworksuchas reinforcedconcreteorreinforced,brickwork (when not included in over all rates ) wrought to required shape as necessary including bendingforpropercompletionofthework and including supply ofsteel itswastage bend hooks and authorised over lapping shall be measured upto floor two level. 141 12mmcementplasteronroughsideofmix 1:4 (1 cement : 4 coarse sand) 142 ProvidingM.S.footrestincludingfixingwith 20x20x10cm.cementconcreteblock1:3:6 (1cement :3coarse sand :6gradded aggregateofnominalsize20mm)asper standard design with 20x20mm sq bars. 143 Providingand fixingC.I.tee at the inlet and outlet of septic tank. 144 Providing & fixing 75mm dia vent pipes. 145 Providing&fixingof75mmdiacastiron terminal guard. 146 ProvidingandfixinginpositionprecastRCC manholecoverandframeofrequiredshape and approved quality. 147 M.D. -10- Circular shape 500mm internaldiameter 148 M.D.-2.5-Circularshape450mminternaldiameter 149 FILLING MATERIAL 150 Supplying, filling, spreading & leveling stone boulders of size range 5cm to 20 cm, in recharge pit, in the required thckness, for all leads & lifts, all complete as per direction of Engineer-in-charge 151 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in recharge pit, over the exising layer of boulders, in the required thckness, for all leads & lifts, all complete as per direction of Engineer-in-charge 152 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm, in recharge pit, over the exising layer of gravels, in the required thckness, for all leads & lifts, all complete as per direction of Engineer-in-charge 153 COST OF 30 KLD STP 154 COST OF HORTICULTURE WORK 155 Site Preparation 156 Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts. 157 Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge. 158 Supplying and stacking of good earth at site including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment) 159 Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) : 160 Screened through sieve of I.S. designation 4.75 mm 161 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge 162 Filling mixture of earth and sludge or manure in the desired proportion in trenches, flooding with water and leveling (cost of supplying earth and sludge or manure and mixing excluded). 163 Rough dressing the trenched ground including breaking clods. 164 Fine dressing of the ground as level specified. 165 GRASS 166 Supplying & Stacking of Selection No.1 Grass at site fresh & free from weeds having proper roots in green including loading, unloading, carriage and all taxes paid etc.and as per direction of officer in charge 167 TREES 168 Pit Preparation 169 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : Holes 1.2m dia and 1.2 m deep tree 170 Supply and plantation 171 Planting best quality container- grown healthy trees ofspecies and height as specified. All trees to be approved before planting. Inclusive of maintenance (as specified in section I, item 6.2) for one year after planting. 172 Plumeria Alba (Champa)-Height-3m 173 Butea Monosperma-Height-3m 174 Anthocephalus cadamba-Height-3m 175 Termenlia Arjuna-Height-3m 176 Ficus Black - Height-3m 177 Azadiractha Indica-Height-3m 178 Madhuca Longifolia-Height-3m 179 Thevetia Nerifolia-Height-3m 180 Plumeria Rubra -Height-3m 181 Bahunia purperia-Height-3m 182 Hyophorbe lagenicaulis - -Height-3m 183 Ficus Infectoria-Height-3m 184 Termenlia catapa-Height-3m 185 Budha velley bamboo-Height-3m 186 Phyllanthus emblica-Height-3m 187 Magnifera Indica-Height-3m 188 Syzygium cumini-Height-3m 189 Ficus Benjamina-Height-3m 190 Delonix regia-Height-3m 191 Peltophorum pterocarpum-Height-3m 192 Alstonia Scholoris-Height-3m 193 Ceiba pentandra-Height-3m 194 Ficus lyrata-Height-3m 195 Ficus blackina-Height-3m 196 Ficus religiosa--Height-3m 197 Palm- 198 Pheonix Sylvestris-Stem Height-3m 199 Washingtonia Felifera-Stem Height-3m 200 Raystone Regia-Stem Height-3m 201 SHRUBS 202 Pit Preparation 203 Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately) 204 Supply and plantation 205 Planting best quality bushy shrubs with healthy root ball,ofspecies and height as specified. All shrubs to Planting best quality pot-grown healthy shrubs of species and height as specified, inclusive of preparation and cultivation of shrub beds as specified in section I. All plants to be approved before planting. Inclusive of maintenance (asspecified in section I, item6.2) for one year after planting. 206 Hamelia patens -Height-30-45 Cm 207 Clerodendron Inremi-Height-20-30 Cm 208 Maurya Exotica-Height-30-45cm 209 Tecoma Capensis-Height-45-60 Cm 210 Ticoma gaudichaudi-Height-45-60 Cm 211 Cicilpenia Pulcherima-Height-45-60 Cm 212 Bougainvilea-Height-45-60 Cm 213 Ficus Panda-Height-45--60 cm 214 Rose-Height-60cm 215 Hymenocallis Littoralis-Height-20-30 Cm 216 Jasminum-Height-45cn 217 Gardenia-Height-45-60 cm 218 Nirium Olender -Height-30-45 Cm 219 Pennisetum Red-Height-45-60 Cm 220 Lavender-Height-45cm 221 GROUND COVERS 222 Verigated Dinnella-Height 15 Cm 223 Wadelia trilobata-Height 15 Cm 224 Lantana camara-Height 15 Cm 225 Lantana Salwania-Height 15 Cm 226 Duranta golden-Height 15 Cm 227 Aspergous-Height 30 Cm 228 Eranthenum Red-Height 15cm 229 Eranthenum green-Height 15cm 230 Clorophylum green-Height-15 cm 231 Seasonal Flower 232 Putenia hybrid 233 IRRIGATION WORK 234 SITC OF PIPING NETWORK IS:1984:1995 PIPE WORK 235 PVC pipe 90mm-6 kg/cm2 ( SUPREME/JAIN/FINOLEX) 236 PVC pipe 75mm-6 kg/cm2 237 PVC pipe 63mm-6 kg/cm2 238 PVC pipe 50mm-6 kg/cm2 239 PVC pipe 40mm-6 kg/cm2 240 Earthworkexcavationand refilling 300 x 450mm 241 SITC OF POP UP & SPRINKLERS & ACCESSORIES 242 Rotatory Pop up- ECO-ROTATOR - 2.5m- 10.7m with Matched Precipitation Rate. MODEL ECO-ROTATOR, 10 CM (4) POP-UP SPRINKLER WITH INTEGRAL MP ROTATOR NOZZLEAND ½ INLET .HUNTER(USA) with CV 243 POP UP SPRAY HEAD - 1.2M -5.2m at 1.0 - MODEL PS ULTRA, 10 CM (4) POP-UP SPRAYS WITH PRE-INSTALLED NOZZLE OR FLUSH PLUG AND ½ INLET 244 SWING JOINT1/2 Pop up Connecting Four Elbow Swing joint Assembly.SJ-512 ½ X 30 CM (12) STANDARD SWING JOINT, 4 SWING ELBOWS 245 PPSERVICE SADDLEofvarying size.1/2 246 SITC OFDRIP LATRAL AND ACCESSORIES 247 DRIP INLINE Black incolour 16 mm size. With all fittings and accessories.(Dripline 16 mm 50 cm 3.8 lph) 248 DRIP ONLINE Black incolour 16 mm size. With all fittings and accessories.(Dripline 16 mm) 249 DRIP EMITERS 8/4/2 LPH 250 Lateral Holding stack to Staple DistributionTubing , DripLine to FinishedGrade. 251 SITC OFVALVES & ACCESSORIES 252 PVC Ball Valve 63mm. 253 Flush VALVE50mm 254 Flush VALVE40mm 255 ISOLATION VALVEin mainlinefor bypass and flow diversion of approved quality .Buterfly valve 75mm 256 AIR RELEASE VALVE double acting 1Air release valve, The working pressure shall be 5 bar. Including service saddle and riser assembly. 257 Brass Quickcoupling valve 3/4Including service saddle and riser assembly. 258 Brass Key threads into top of QCV to provide water access And Brass Swivel Elbow 259 VALVE BOX12 Rectangular Valve Box 260 VALVE BOX 10 Round Valve Box 261 VALVE BOX6Roundbox 262 SITC OF FILTERATION UNITWITH ASSEMBLY 263 DISC FILTER- 50m3/hr 264 SITC OF PUMPING UNIT 265 PUMP SET(Monoblock/Openwell submersible) pumpset of having discharge 6-6.5 lps@58 mtrhead .suitable for pumpset having panel boxand fixed alongwith following accessories starter ,start / stop push buttons , Ammeter,Voltmeter , Indicating lamps, MCB ,with cable,etc. 266 Control panelsuitable for pumpset having panel boxand fixed alongwith following accessories starter ,start / stop push buttons , Ammeter,Voltmeter , Indicating lamps, MCB , with cable, etc. 267 Suction ,Delivery & Header Pipe 268 ControlValve /Butterfly Valvein mainlinefor bypass and flow diversion 3 269 Non Return Valveto prevent back flow 3 270 Pressure Release Valve2 hydraulic operation 271 DESIGN CHARGES 272 AUTOMATION WORKS 273 SITC OFAUTOMATION EQUIPMENTS 274 Direct burial 14 AWG x 2C cablefor TWO way communication betweenControler and Decoders 275 Conduit Pipe complete32 mm 276 I-CORE: COMMERCIAL CONTROLLERSwith 48-STATION DECODER OUTPUT MODULEFOR I-CORE CONTROLLER , plastic cabinet outdoor, wall mount, internal transformer control system , cycle +soak, Raindelay, SOLARSYNC Mini weather station,controlling upto 1mastervalve. (IC-601-PL + ICM-600) 277 DECODER ICD-100 1-STATION DECODER FOR , INCLUDES 2 WATERPROOFCONNECTORS 278 SOLENOID VALVE 1.5Solenoid globe Valvespressure rating upto 10 bar with 24AC solenoid, withprovision to attachPressure Regulator 279 SOLENOID VALVE 2Solenoid globe Valvespressure rating upto 10 bar with 24AC solenoid, withprovision to attachPressure Regulator 280 DBRY DIRECT BURIAL WATERPROOF CONNECTORS, DBRY-6 ULLISTED UP TO 600V 281 PRESSURE REGULATOR, ACCU-SYNC-ADJ ACCU-SYNC ADJUSTABLE PRESSURE MODEL 1.4–7 BAR (20–100PSI), WORKS WITH ANY HUNTER VALVE 282 Copper grounding rod, clamps, charcoal and all requisite accessories complete 283 Pump relay24 ACPLA relay 284 Voltage stabiliser (KW) 285 Poly Fibre CottageLUXARY - Inside Washroom 286 POLY FIBERGAZEBO 287 POLY FIBRE GAZEBO - RUBENS ( 14FT x 14FT ) 288 POLY FIBRE GAZEBO , Poly Fibre Fencing,Poly Fibre Lamp Post - Bolard 289 ESTIMATE FOR POLY FIBERPERGOLA 290 POLY FIBRE PERGOLA - CUSTOMIZED Beam,Purlin etc ( 10 m X 4 m ) 291 POLY FIBRE SEMI CIRCULAR PERGOLA - CUSTOMIZED incuding Beam,Purlin etc ( 10 m X 4 m ) 292 FRP GATE 293 NATURE PARK ENTRANCE GATEWAY (15ft x 18ft) 294 RUBBERISED FLOORING 295 EPDM FLOORING 296 TICKET BLOCK 297 Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) &includingfilling,wateringandrammingofexcavatedearth intothetrenchesorintothe spacebetweenthe buildingand the sides of foundation trenches or into the plinth and removal anddisposalofsurplusearthasdirectedbytheEngineer- Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. 298 Providingandlayingcementconcrete1:4:8(1cement:4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for propercompletion of the work and curing complete also including cost of formwork in foundation & floors. 299 Sand filling in plinth including supply of necessary quantity of sandfromadistancenotexceeding8kms.fromthesiteof work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. 300 Providing and injecting chemical emulsion for preconstructionalantitermitetreatmentandcreatinga chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junctionofwallandfloor,alongthe theexternalperimeterof bindingexpansionjoints,surroundingofpipesandconduits etc, complete (plinth area of the building at ground.flooronlyshallbemeasuredasperI.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved materialsuchasHeptrachlororChlordanewillbeused.The rateof applicationof chemicalemulsionshallbeasfollows: (1)Treatment formasonary & foundation5 literspersqm.(2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm(4)Treatmentofsoilalongexternalperimeterofbuilding7.5 liters/sqm. (5)Treatmentofsoilunderapronalongexternal perimter 5 liters/sqm. 301 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 302 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 303 M-150brickworkinonecement&6coarsesand2.25F.M. mortar in foundation and plinth including supply of all materials labour, tools and plants etc. required for proper completion of the work. 304 M-150Brickworkinsuper-structureaboveplinthlevelupto floor two level (up to two storeys) includingnecessary cutting and moulding of bricks as requiredand also including honey comb brick work thickness of wall not to be less than 1.5 brick thick. (1:6 cement & coarse sand) 305 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 306 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 307 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding 308 Providing & fixing glasspanes withputty andglazingclipsin steeldoors,windows,clerestorywindows,allcompletewith: (a) 4 mm thick. 309 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 310 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 311 Fixing of Door, windows/ventilators chaukhats in position. 312 (a) Door 313 (c) Ventilator chaukhats 314 12 mm cement plaster of mix : 315 1:6 (1 cement: 6 coarse sand) 316 20 mm cement plaster of mix : 317 1:6 (1 cement: 6 coarse sand) 318 40mmthick1:2:4plaincementconcretefloor(1cement:2 coarsesand:4gradedstoneaggregate12-20mmnominal size laid in one layer neat cement. 319 Distempering (Two coat) with oil bound distemper of approved brandandmanufacture&ofrequiredshadeonundecorated wall surface to give an even shade over & including a priming coatwithcementprimerofapprovedbrand&manufacture suchasBerger,J&N,Shalimar,Asianpaintsafterthoroughly brushingthe surfacefree from mortardroppings& other foreignmatters&alsoincludingpreparingthesurfaceeven withplasterofparisorapprovedsyntheticmaterial&sand papered smooth including cost ofall materials.(Ceiling) 320 Providingandapplyingwhitecementbasedputtyofaverage thickness1mm,ofapprovedbrand& anufacturer,overthe plastered wallsurface topreparethe surfaceeven & smoothcomplete. 321 Providingandfixingbrightfinishedbrasshangingtypefloor door stopper with necessary screws, etc. complete. 322 Providing andfixingaluminiumslidingdoorbolts,ISI markedanodised (anodiccoatingnotlessthangradeAC 10 as per IS : 1868), transparentor dyed to required colour or shade, with nuts and screws etc. complete ::300x16 mm 323 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodiccoating not less than grade AC 10 as perIS:1868 ) torequiredcolourorshade,with necessaryscrewsetc.complete 324 (a) 250 mm x 10mm 325 (a) 200 mm x 10mm 326 Providingandfixingaluminiumhandles,ISImarked, anodised (anodiccoating not less than grade AC 10 as perIS:1868)transparentordyed torequired colouror shade,withnecessaryscrewsetc.complete 327 Centering and shuttering including strutting, propping etc. and removal of form for 328 Suspended floors, roofs, landings, balconies and access platform 329 Lintels, beams, plinth beams, girders, bressumers and cantilevers 330 TICKET BLOCK ELECTRICAL WORKS 331 Wiring for light point/ fan point/ exhaust fan point/callbellpointwith1.5sq.mmFRLS PVCinsulatedcopperconductorsinglecore cable in surface / recessed medium class PVC conduit,withmodularswitch,modularplate, suitableGIboxandearthingthepointwith 1.5sq.mmFRLSPVCinsulatedcopper conductor single core cable etc. as required. Group C 332 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 333 Wiring for light/ power plug with 2X4 sq. mm FRLSPVCinsulatedcopperconductorsingle core cable in surface/recessed mediumclass PVCconduitalongwith1No.4sq.mmFRLS PVCinsulatedcopperconductorsinglecore cable for loop earthing as required. 334 Supplying and fixing of following sizes of medium class PVC conduit along with accessoriesinsurface/recessincluding cutting the wall and making good the same in case of recessed conduit as required.: 25 mm 335 Wiring for circuit/ submainwiring alongwith earthwirewiththefollowingsizesofFRLS PVCinsulatedcopperconductor,singlecore cable in surface/recessedmediumclassPVC conduit as required. 336 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 337 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 338 Providingandfixing6SWGdiaG.I.wireon surface or in recess for loop earthing asrequired. 339 Supplying and fixing following way, single pole and neutral, sheet, MCB distribution board, 240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painteed including earthing etc as required. (But without MCB/RCCB/Isolator) 6 Way, Double door 340 Supplying and fixing 6 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of followingpolesin theexistingMCBDB complete with connections, testing and commissioning etc. as required. Single pole 341 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the exising MCB DB complete with connections, testing and commissioning etc. as required. 32 A DP 342 Supplying and fixing single pole blanking plate in the existingMCB DB completeetc. asrequired. 343 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6&15/16Amodularsocketoutletand 15/16Amodularswitch,connectionsetc.as required. 344 Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. CAT-AA 345 Supply and fixing of water tight oblong 10 Watt LED bulkhead luminaire with driver set confirming to IP 65 and above Protection . complete in all respect. CAT-AA 346 BOUNDARY WALL 347 Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) &includingfilling,wateringandrammingofexcavatedearth intothetrenchesorintothe spacebetweenthe buildingand the sides of foundation trenches or into the plinth and removal anddisposalofsurplusearthasdirectedbytheEngineer- Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. 348 Providingandlayingcementconcrete1:4:8(1cement:4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for propercompletion of the work and curing complete also including cost of formwork in foundation & floors. 349 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 350 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 351 Providing and fixing G.I. Chain Link fabric of required width in mesh 50X50 mm including strengthening with 2mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-In-Charge Made of G.I. wir of 4mm dia, PVC coated to achieve outer dia not less than 5 mm in required colour and shape 352 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 353 TOILET BLOCK 354 Excavation in foundations in ordinary soil (Loam clay or sand) including lift upto 1.5 m (5 fts.) and lead upto 30 mt. (100 fts.) &includingfilling,wateringandrammingofexcavatedearth intothetrenchesorintothe spacebetweenthe buildingand the sides of foundation trenches or into the plinth and removal anddisposalofsurplusearthasdirectedbytheEngineer- Incharges upto a distance of 30mt. (100 fts) from the foundation trenches. 355 Filling of carted earth. 356 Providingandlayingcementconcrete1:4:8(1cement:4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P rtc required for propercompletion of the work and curing complete also including cost of formwork in foundation & floors. 357 Sand filling in plinth including supply of necessary quantity of sandfromadistancenotexceeding8kms.fromthesiteof work and including watering, dressing etc rate to include cost of all materials labour T & P etc required for proper completion of work. 358 Providing and injecting chemical emulsion for preconstructionalantitermitetreatmentandcreatinga chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth filling junctionofwallandfloor,alongthe theexternalperimeterof bindingexpansionjoints,surroundingofpipesandconduits etc, complete (plinth area of the building at ground.flooronlyshallbemeasuredasperI.S.6313(PartII 1981)Alderine emulsifiable concentrate or any other approved materialsuchasHeptrachlororChlordanewillbeused.The rateof applicationof chemicalemulsionshallbeasfollows: (1)Treatment formasonary & foundation5 literspersqm.(2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm(4)Treatmentofsoilalongexternalperimeterofbuilding7.5 liters/sqm. (5)Treatmentofsoilunderapronalongexternal perimter 5 liters/sqm. 359 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural so 360 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 361 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 362 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 363 Providingandlayingdamp-proofcourse40mmthickwith cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) 364 Providing & applying a coatof residualpetroleum bitumen of gradeofVG-10ofapprovedqualityusing1.7kgpersquare metreondampproofcourseaftercleaningthesurfacewith brushesandfinallywithapieceofclothlightlysoakedin kerosene oil. 365 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 366 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) 367 Providing & laying brickCoba 120mmthicklaidwith M-150 class brick bat coba 7.50 cm thick with gap of 15mm to each other, over 20mm thick base of cement mortar 1:4 cement and coarsesandmixedwithwaterproofingcompoundspreading cement slurry mixed with acrylic cement concrete water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compoundin1:4cementandcoarsesandmortarfinished smooth & topmashedfalse square30cmx 30 cmandside wall parapet shall be mono lythic plaster wall upto 30cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonry coba with top finished plaster mixed with acetic water proofing compound @ 2%byweight&includingS/oallmaterial,labourT&Petc complete for proper completion of work. 368 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board constructionwithframeof1stclasshardwoodandwell matchedcommercial3plyveneeringwithverticalgrainsor cross bands and face veneers on both faces of shutters: 35 mm thick (Single Leaf) 369 ExtraforProvidingandfixingflushdoorswithdecorative veneeringinsteadofnondecorativeISImarkedflushdoor shutters conforming to IS: 2202 (Part I) 370 Mildsteelorironworkofsmallsizesandsectionssuchas holdingdownbolts,holdfasttierods,gratingsetc.(whennot included in an over all rates) wrought to required from includingsupplyofsteelanditswastageincludingcostof bolts,nutsifrequiredforandwelding,grindingandmaking holesasrequiredcompletionofworkfabricationofholes doors, chaukhats nosing. 371 Hold fast for chaukhats of doors/windows. 372 Hold fast for chaukhats of doors/windows. 373 Supply, fabrication & fixing of Z-Section steel window 374 Providing and fixing M.S. Tubularframes for doors,windows, ventilatorsandcupboardwithrectangular/L-Typesections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat ofapprovedsteelprimer. Fixingwith15x3mmlugs10cm longembeddedincementconcreteblock15x10x10cmof C.C.1:3:6(1Cement:3coarsesand:6gradedstone aggregate 20 mm nominal size) 375 Providing & fixing glasspanes withputty andglazingclipsin steeldoors,windows,clerestorywindows,allcompletewith: (a) 4 mm thick. 376 TMT FE-500 or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of all steel and and over lapping & hooks. 377 Fixing of Door, windows/ventilators chaukhats in position. 378 (a) Door 379 (c) Ventilator chaukhats 380 15 mm plinth plaster (1 cement :4 coarse sand) 381 Red sand stone for wall lining etc. (veneer work) upto 10 metre height,backingfilledwithagroutofaverage12mmthick cementmortar1:3(1cement:3coarsesand)including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. 40 mm thick 382 15 mm cement plaster in single coat on rough side of single or halfbrickwallforinteriorplasteringuptofloortwolevel includinginternalroundedanglesnotexceeding80mmin girth and finshed even and smooth. (1) 1 cement : 6 fine sand. 2.25.F.M. 383 Making grooves 10 to 12mmwide x8mm deep in plaster of the walls or in ceiling vertically or horizontally as required 384 40mmthick1:2:4plaincementconcretefloor(1cement:2 coarsesand:4gradedstoneaggregate12-20mmnominal size laid in one layer neat cement. 385 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchenplatforms,vanitycounters,windowsills,faciasand similar locations of required size, approved shade, colour and texturelaidover20mmthickbasecementmortar1:4(1 cement:4coarsesand),jointstreatedwithwhitecement, mixedwithmatchingpigment,epoxytouchups,including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 386 Granite of any colour and shade (Area of slab upto 0.50 sqm) 387 Granite of any colour and shade (Area of slab over 0.50 sqm) 388 Paintingwithsyntheticenamelpaintofapprovedbrandandmanufacture of required colour to give an even shade : 389 Same as item 38 above but on new wood surface. 390 Distempering (Two coat) with oil bound distemper of approved brandandmanufacture&ofrequiredshadeonundecorated wall surface to give an even shade over & including a priming coatwithcementprimerofapprovedbrand&manufacture suchasBerger,J&N,Shalimar,Asianpaintsafterthoroughly brushingthe surfacefree from mortardroppings& other foreignmatters&alsoincludingpreparingthesurfaceeven withplasterofparisorapprovedsyntheticmaterial&sand papered smooth including cost ofall materials.(Ceiling) 391 Providingandapplyingwhitecementbasedputtyofaverage thickness1mm,ofapprovedbrand& anufacturer,overthe plastered wallsurface topreparethe surfaceeven & smoothcomplete. 392 Providingandfixingbrightfinishedbrasshangingtypefloor door stopper with necessary screws, etc. complete. 393 Providing andfixingaluminiumslidingdoorbolts,ISI markedanodised (anodiccoatingnotlessthangradeAC 10 as per IS : 1868), transparentor dyed to required colour or shade, with nuts and screws etc. complete ::300x16 mm 394 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodiccoating not less than grade AC 10 as perIS:1868 ) torequiredcolourorshade,with necessaryscrewsetc.complete 395 (a) 250 mm x 10mm 396 (a) 200 mm x 10mm 397 Providingandfixingaluminiumhandles,ISImarked, anodised (anodiccoating not less than grade AC 10 as perIS:1868)transparentordyed torequired colouror shade,withnecessaryscrewsetc.complete 398 Providing and fixing stainless steel ( Grade 304) railing made of Hollowtubes, channels, plates etc., including welding, grinding,buffing,polishingandmakingcurvature(wherever required)andfittingthesamewithnecessarystainlesssteel nutsandboltscomplete,i/cfixingtherailingwithnecessary accessories &stainless steeldashfasteners ,stainlesssteel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge,(forpaymentpurposeonlyweightof stainlesssteelmembersshallbeconsideredexcludingfixing accessories such as nuts, bolts, fasteners etc.). 399 Making of draing along with apron 150 X 150 MM 400 Centering and shuttering including strutting, propping etc. andremoval of form for : 401 (a)Foundations,footings,basesofcolumns,etc.formass concrete 402 (b)Suspendedfloors,roofs,landings,balconiesandaccessplatform 403 (c)Lintels,beams,plinthbeams,girders,bressumersandcantilevers 404 (d) Columns, Pillars, Piers, Abutments, Posts and Struts 405 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of Size of Tile 600 x 600 mm 406 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. 407 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 408 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Vitrified tiles Matt/Antiskid finish of Size of Tile 600 x 600 mm 409 PLUMBING WORKS 410 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 411 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever requiredW.C. pan with ISI marked white plastic seat and lid 412 ProvidingandfixingwashbasinwithC.I.brackets,15mmC.P.brass pillar taps,32mmC.P.brass waste ofstandard pattern, including paintingoffittingsandbrackets,cuttingandmakinggoodthewalls wherever require: WhiteVitreousChinaFlatbackwashbasinsize550x400mmwith single 15 mm C.P. brass pillar tap. 413 ProvidingandfixingflexibleP.V.C.wastepipeforsinkorwashbasin including PVC waste fittings complete. Semi rigid pipe a) 32mm dia 414 Providingandfixing600x450mmbevelededgemirrorofsuperior glass(ofapproved quality)complete with6mmthickhardboard groundfixedtowoodencleatswithC.P.brassscrewsandwashers complete. 415 Providingandfixing8mmdiaC.P./S.S.Jetwithflexibletubeupto1 meter long with S.S. triangular plate for Eureopean type W.C. of quality and make as approved by engineer-in-charge. 15mm nominal bore 416 Providing and fixing Toilet paper holder a) C.P. brass 417 Providingand fixing PTMTLiquid soapcontainer109 mm wide ,125 mmhighand112mmdistance fromwallofstanderd shapewith bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms. 418 ProvidingandfixingonwallfaceunplasticisedRigidPVCrainwater pipes conformingto IS : 13592 Type A including jointing with seal ring conformingto IS: 5382 leaving10 mm gap for thermal expansion. (i) Single socketed pipes. 110mm diameter 419 Makingkhurras45x45cmwithaverageminimumthicknessof5cm cementconcrete1:2:4(1cement:2coarsesand:4gradedstone aggregateof20mmnominalsize)overPVCsheet1mx1mx400 micron,finishedwith12mmcementplaster1:3(1cement: 3coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. 420 Providingandfixingunplasticised-PVCpipeclipsofapproveddesign to unplasticised- PVC rain water pipes by means of 50x50x50mmhard woodplugs,screwedwithM.S.screwsofrequiredlengthincluding cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm 421 Providingandfixingtotheinletmouthofrainwaterpipecastiron grating 15 cm diameter and weighing not less than 440 grams. 422 Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc.(internal work)Exposed on wall50mm dia nominal bore 423 Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality.50mm dia nominal bore. 424 ProvidingandfixingChlorinatedPolyvinylChloride(CPVC)pipes, having thermal stability for hot & cold water supply including all CPVC plain & brassthreadedfittingsincludingfixing the pipe with clampsat 1.00mspacing. Thisincludesjointingof pipes& fittingswithonestep CPVCsolvent cementand testing of jointscompleteas per directionof Engineer in Charge. 425 internal work -Exposed on wall 426 20mm dia nominal outer dia pipes 427 25mm dia nominal outer dia pipes 428 ProvidingandfixingChlorinatedPolyvinylChloride(CPVC)pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. Thisincludesjointingofpipes&fittingswithonestepCPVC solventcementandthecostofcuttingchasesandmakinggoodthe same including testiangof joints completeas per directionof Engineer in Charge.Concealedworkincludingcuttingchasesandmakinggoodthewalls etc. 429 15mm dia nominal outer dia pipes 430 20mm dia nominal outer dia pipes 431 Providingandfixing45cmlongunplasticisedPVCconnectionpipe with brass unions. 15mm nominal bore 432 Providing& fixingCPbrassbibcockofapprovedqualityconforming to IS 8931 15mm nominal bore 433 Providing& fixingC.P. brasslongbodybibcockofapprovedquality conforming to IS standards and weighing not less than 690 gms.15mm nominal bore 434 Providing&fixingC.P.brassanglevalveforbasinmixerandgyser points of approved quality conforming to IS 8931 15mm nominal bore 435 Providing & fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge. 436 Providingandfixinggunmetalgatevalvewithwheelofapproved quality. 437 25mm dia nominal bore 438 20 mm dia nominal bore 439 Providingandfixingballvalve(brass)ofapprovedquality,Highor low pressure, with plastic floats complete 25 mm nominal bore 440 Providing andplacingonterrace(atallfloorlevels)polyethylene water storage tank. IS:12701 marked, with cover and suitable locking arrangementand making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 441 Excavatingtrenches inallkindofsoilofrequiredwidthforpipes, cables etc. including excavation for sockets and dressing of sides, ramming ofbottoms, depth upto 1.5 m. including getting outthe excavated soil & then returning the soil as required,inlayersnotexceeding20cmindepthincludingconsolidatingeach deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m.Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. 442 Providing,laying and joiningglazedstoneware pipesclassSP-1 with stiffmixtureofcementmortarintheproportionof1:1(1cement:1 fine sand) including testing of joints etc. complete. 443 100mm diameter 444 150mm diameter 445 Providing&layingcementconcrete1:5:10(1cement:5coarsesand :10gradedstoneaggregate40mmnominalsize)alroundS.W.Pipes including bed concrete as per standard design. 446 100mm diameterS.W. Pipe 447 150mm diameterS.W. Pipe 448 Providing and fixing square mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frameof300x300mmsize(inside)theweightofcovertobenotless than4.50Kgandframetobenotlessthan2.70Kgasperstandard design: 150 x 100 mm. size P type With Sewer bricks conforming to IS : 4885 449 Constructingbrickmasonrymanholeincementmortar1:4(1cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size)insideplastering12mmthickwithcementmortar1:3(1cement :3coarsesand)finishedwithfloatingcoatfoneatcementandmaking channelsin cementconcrete1:2:4(1 cement:2 coarsesand:4 graded stone aggregate 20mm nminal size) finished with a floating coat of neatcement complete as per standard design Insidesize90x80cmsand45cmsdeepincludingCIcoverwithframe (lightduty)455x610mminternaldiamensionstotalweightofcover and frameto be not lessthan 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 75 (i) For Sewer Line 450 Providing and fixing soil, waste and vent pipes :75 mm Dia Hubless centrifugally cast(spun)ironpipesepoxycoatedinside& outside IS:15905 451 100 mm dia Hubless centrifugally cast(spun)ironpipesepoxycoatedinside& outside IS:15905 452 Providing and fixing trap of self cleansing design with screwed down or hingedgratingwithorwithoutventarmcomplete,includingcostof cutting and making good the walls and floors : 453 100 mm inlet and 100 mm outlet Hubless centrifugallycast (spun) iron epoxy coated inside & outside as per IS:15905 454 Providing and fixing plain bend of required degree. 75 mm dia Hubless centrifugally cast(spun)ironpipesepoxycoatedinside& outside IS:15905 455 100 mm dia Hubless centrifugally cast(spun)ironpipesepoxycoatedinside& outside IS:15905 456 Providing and fixing terminal guard : 457 75 mm Sand cast iron S&S as per IS - 3989 458 100 mm Hubless centrifugallycast (spun) iron epoxy coated inside & outside as IS : 15905 459 Providing and fixing single equal plain junction of required degree : 460 75x75x75 mm 461 100x100x100 mm 462 Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 463 Size 75 mm 464 Size 100 mm 465 ELECTRICAL WORKS 466 Wiring for light point/ fan point/ exhaust fan point/callbellpointwith1.5sq.mmFRLS PVCinsulatedcopperconductorsinglecore cable in surface / recessed medium class PVC conduit,withmodularswitch,modularplate, suitableGIboxandearthingthepointwith 1.5sq.mmFRLSPVCinsulatedcopper conductor single core cable etc. as required. Group C 467 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 468 Wiring for light/ power plug with 2X4 sq. mm FRLSPVCinsulatedcopperconductorsingle core cable in surface/recessed mediumclass PVCconduitalongwith1No.4sq.mmFRLS PVCinsulatedcopperconductorsinglecore cable for loop earthing as required. 469 Supplying and fixing of following sizes of medium class PVC conduit along with accessoriesinsurface/recessincluding cutting the wall and making good the same in case of recessed conduit as required.: 25 mm 470 Wiring for circuit/ submainwiring alongwith earthwirewiththefollowingsizesofFRLS PVCinsulatedcopperconductor,singlecore cable in surface/recessedmediumclassPVC conduit as required. 471 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 472 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 473 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 474 Supplying and laying 25 mm X 5 mm G.I strip at0.50metrebelowgroundasstripearth electrode,includingconnection/terminating with G.I. nut, bolt, spring, washer etc. As required.(Jointingshall be done by overlappingand with2 sets of G.I. nut bolt & spring washer spaced at 50mm) 475 Providingandfixing6SWGdiaG.I.wireon surface or in recess for loop earthing asrequired. 476 Supplying and fixing following way, single pole and neutral, sheet, MCB distribution board, 240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painteed including earthing etc as required. (But without MCB/RCCB/Isolator) 16 Way, Double door 477 Supplying and fixing 6 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of followingpolesin theexistingMCBDB complete with connections, testing and commissioning etc. as required. Single pole 478 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the exising MCB DB complete with connections, testing and commissioning etc. as required. 40 A DP 479 Supplying and fixing single pole blanking plate in the existingMCB DB completeetc. asrequired. 480 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6&15/16Amodularsocketoutletand 15/16Amodularswitch,connectionsetc.as required. 481 Installation of exhaust fan ( upto 450 mm dia) in the existing opening, including making commissioning etc. as required. 482 Supply and fixing of recess/ Surface/ Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT-AA 483 Supply and fixing of recess/ Surface/ Pendent mounting round 10 to 15 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. CAT-AA 484 Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect.CAT-AA 485 Supply and fixing of water tight oblong 10 Watt LED bulkhead luminaire with driver set confirming to IP 65 and above Protection . complete in all respect.CAT-AA 486 Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts, nuts and washers etc., complete in all respect. 487 Making hole in the wall for exhaust fan and finishing properly complete in all respect. 488 Supply and fixing of 16 SWG M.S. drum with luvers duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect. 489 ProvidingandfixingM.V.dangernoticeplate of 200mmX 150mm,madeofmildsteel,at least 2 mm thick, and vitreous enameled whiteonbothsides,andwithinscriptionin single red colour on front side as required. 490 Supplyof AC 230/250 Volts, 50 Hz 55w 1400 rpmexhaustfansincluding providing nuts, bolts,mountingframeandotheraccessories including connections etc. complete as required.-Make: Havells-STANDARD Refresh Air-SPS 300mm sweep. 491 GAMES KIOSK ( 20 No.) 492 Poly carbonate Sheet with M.S Pipe Fitting,All M.S Pipe Painting incuded Size - 10Feet Height ( 20x100) Sqft 493 ZIPLINE & ZIPCYCLE 100 MTR&WALL CLIMBING 494 RCC FOUNDATION RCC MATE RIAL 495 MS TOWER (IRON STRUCTURE) POLO 12/10/30FT 496 WIRW FORZIPLINE,SMALLWALL,TRYMAH ADEV ,USHA MATENNET ,COMMANDO NET,BEALANCE WHEEL12MM: 350MTR 497 TURN BUCKLE ,KIMBLE ,D-CICLE ,U-CLAMP 498 HARNESS ,HELMENT ,PULLY ,TAP INDIA IMPO RTED 499 CYCLE ,DIVICE INDIA IMPO RTED 500 ZIPLINE BREAKING SYSTEMINDIA IMPO RTED 501 CARABINER , MITTEN INDIA IMPO RTED 502 INSULATION AND DRAWING 503 TRANSPORTATION 504 HARNESS,MITTEN,CARABI NER,ROPEIMPO RTED, 100M TR 505 HOLD,CARRIAGE BOLT, FASTENER INDIA IMPO RTED 325 506 CLIMBING PANNEL LIMBING WALL IRON FRAME, PAINT WATER PROFE, IMPO RTED 507 INSULATION AND DRAWING IMPO RTED 508 ESTIMATE FOR CCTV CAMERA 509 PTZ Camera :IP 4 MP 200 Mtr IR PTZcamera:Supply, installation, testing & commissioning of Image Sensor 1/1.9‟‟ Progressive Scan CMOS, Min. Illumination Color : 0.002 lux (F1.5,AGC On) B/W : 0.002 lux (F1.5, 1/1 sec, 50 IRE, AGC On) 0 lux with IR, White Balance Auto/ Manual /ATW/Indoor/Outdoor/Daylight lamp/Sodium lamp AGC Auto / Manual, Optical Defog and inbuilt Wiper, 3D DNR; HLC; BLC, 120 dB True WDR, EIS, Shutter Time 50Hz: 1-1/30,000s , Digital Zoom 16X , 8 privacy masks programmable , Focal Length 5.7-205mm, 36x , Pan Range 360° endless , Pan Speed Pan Manual Speed: 0.1°-160°/s, Pan Preset Speed: 240°/s Tilt Range (-20°-90° Auto Flip ) , Tilt Speed Tilt Manual Speed: 0.1°-120°/s, Tilt Preset Speed: 200°/s , Number of Preset 300 , Smart tracking , Supported IR Distance 360 degree coverage ; with 200 mtr ir, Alarm Input 7 , Alarm Output 2 relay outputs, alarm response actions configurable , Alarm Trigger Face detection, Intrusion detection, Line crossing detection, Audio exception detection, Region entrance detection, Region exiting detection Audio Input 1 Mic in/Line in interface Line input: 2-2.4V[p-p]; output impedance: 1KΩ, ±10% , Audio Output 1 Audio output interface Line level, impedance: 600Ω Max. Image Resolution 1920×1080 , Image Compression H.265,H.264,MJPEG,MPEG4, H.264 encoding with Baseline/Main/High profile , Audio Compression G.711ulaw/ G.711alaw/ G.726/ MP2L2 , Three Streams , ONVIFProfile S & Profile G , Power 24VAC Max. 60W (with IR ON) ; HI-POE , Working Temperature / Humidity -30 ℃-65℃ (-22℉-149℉) (outdoor) 90% or less, Protection Level IP66 standard, Certification FCC,CE,UL,BIS 510 Supply ofIP CCTV Bullet Camera Camera 2 MP (2560x1920) , 1~25/30fps image with a 2 Megapixel progressive scan CMOS sensor.WDR, ensuring glare-freeimages.WDR range: 120dB ,True day/night functionality providing vivid color images by day and clear black-and-white images at night with ICR.Excellent low-light performance with 3D noise reduction, and together with H.265 Profile codec saving storage and bandwidth.2.8mm~12mm, MFZ, F1.4~F2.8., varifical lens.H.265, H.264 and MJPEG codec with triple streams support. 22°F to 140°F (30°Cto 60°C) working Profile S/Gsupport.Security features include self-signed signed certificates and data encryption. (For Outdoor Application) 511 Supply of 16 Channel NVR 2 SATA upto 10TB Non-POE 512 Supply of 10TB HDD Surveillance Internal Hard Drive HDD 513 Supply of 4m GI Pole for PTZ cameras 514 Supply ofControl Board - Joystick, Keypad & Jog Dial 515 6 Core Fiber Multimode Ar. 516 Supply of 12 Port Fiber LIU Loaded with SC SM Coupler, as per given Specification etc. all complete 517 Supply of 6 Port Fiber LIU Loaded with SC SM Coupler, as per given Specification etc. all complete 518 Supply ofSC-LC SM Fiber Patch Cords (3 Mtr) as per given Specification etc. all complete 519 Supply of L2 16 Port POE+ Switch- copper switch 520 Supply ofMedia convertor 1000 Mbps with Industrial grade standard with IP 6 rated with PoE injection with all accessories 521 Supply of CCTV Monitoring Workstation with Intel Xeon 8 core 3.8 GHz processor, 64 GB RAM, 500 GB SSD, Nvidia P2200 Graphics, 2x 1G Ethernet ports, Windows 11 OS, 522 Supply of Professional Grade Display Panel, 42 Screen Size, Native resolution 1920 x 1080 (16:9), 4K Mainstream Proff Display for AVSI & Digital Signage Project along with Wall mount kit etc. all complete 523 Copper Patch Cord 3 meters 524 Solar Pphotolatic Cell 525 Seating /Benchs 526 Dustbin 527 KIDS PLAY EQUIPMENTS 528 Duplex Four Unit Royal MAPS 529 Giraffe Slide 530 Tripple Wave Slide 531 Two Seater Dolphin Swing 532 Two Seater See Saw -Caterpillar 533 Camel Spring Rider 534 Deluxe Family Swing Three Seater 535 Half Arc Net Rope Climber 536 Rope Climber 537 SCULPTURES 538 Development of pond with finishes 539 Water Fall Sculpture at the center 540 Aquatic animals and Birds related sculptures life size animal and bird 541 SCULPTURES IN GREEN AREA AROUND POND 542 SCULPTURES ALONG NATURE WALK 543 SCULPTURES ALONG NATURE WALK 544 SCULPTURES ALONG NATURE WALK 545 SCULPTURES ALONG NATURE WALK 546 SCULPTURES ALONG NATURE WALK 547 SCULPTURES ALONG NATURE WALK 548 SCULPTURES IN SUNKEN LAWN MUD HOUSE 549 RAM JI HISTORY RELATED SCULPTURES WITH RESPECT TO CHITRAKOOT 550 RAM JI HISTORY RELATEDSCULPTURES WITH RESPECT TO CHITRAKOOT 551 NATURE PARK SIGNAGE ( 8X8) Feet 552 GST Extra as per applicable

Key Value

Document Fees
INR 17700 /-
EMD
INR 1800000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail