Tender For Repair/Maintenance Of Lt Network Including Lt Panel, Acsr Conductors Of Different Location At Baramulla, Pattan, Haws And Gulmarg Under Ge 969 Ews; 1 Excavation in trenches n exc 1.5 m wide & n exc 1.5 mtr deep in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holesetc not exc 10 sqm on plan and n exc 1.5 mtr in depth and getting out of soft/lose soil for taking out pipe & laying of pipe & getting outfor diverting of CI pipeline complete all as directed. 2 Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as directed. 3 Returning, filling in, including spreading, leveling, watering & well ramming in layers n. exc 25 cmcomplete all as directed. 4 M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified 5 M&L for Sub class B bricks laid dry width wise across the line of cable in treanchs as cable protection complete all as specified. 6 Supply & laying of UG cable LT 1100 volts grade XLPE insulated armouredheavy duty elect cable with stranded aluminiumconductorcross section area 95 Sqmm 3.5 core laid in trenches or passing through pipe including connecting with suitable lugs, glands, nuts and bolts and testing complete all as specified and directed. Make: Havells/CCI/Gloster/Finolex 7 All as per item No 6 here in before but of size 70 sqmm 3.5 core 8 All as per item No 6 here in before but of size 50 sqmm 3.5 core 9 All as per item No 6 here in before but of size 35 sqmm 3.5 core 10 All as per item No 6 here in before but of size 25 sqmm 3.5 core 11 All as per item No 6 here in before but of size 16 sqmm 4 core 12 All as per item No 6 here in before but of size 16 sqmm 2 core 13 All as per item No 6 here in before but of size 10 sqmm 2 core 14 S&FMCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA. Make : Indoasian /L&T/ Legrand/ABB/Havells/Standard 15 All as per item No. 14 but 125A, 16 KA 16 S & F MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA 17 S & F MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA 18 S & F MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA 19 S & F MCCB 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA 20 Scraping, cleaning and preparation of surface of steel pole for paintingwith the help of sand paper, wire bursh and cotton cloth and applying externally with two coats of syntheticenamelled paint as zebra strip type from ground level to 1.5mtr heightand aluminium paint from 1.5mtr height to top plug level over a coat of red oxide primer completeall as specified and directedby the Engr-in-Charge 21 Supply and fix house service bracket ,hook type complete with 3.0M long GI Pipe 50mm Dia medium grade two Nos 90 degree bend MS hook and stay guy complete all as specified and directed. 22 Supply and laying GI pipe 80 mm bore light grade with fitting for cable protection at road crossing/under concreteincluding taking down of old one. 23 Supply and laying GI pipe 50 mm bore light grade with fitting for cable protection at road crossing/under concreteincluding taking down of old one. 24 Supply, jointing & testing, outdoor type cable end termination joint Heat shrinkable) complete with jointing material and accessories suitable for 3 wire, 11 KV (Earthed) grade, HT underground XLPE insulated armoured aluminium conductor, 3 core 95 sqmm size cable, complete all as specified and directed. 25 Supply, jointing & testing ,straight through cable joint kit (Heat shrinkable) complete with jointing material and accessories suitable for 3 wire , 11 KV (Earthed) grade, HT, Underground XLPE insulated armoured aluminium conductor, 3 core 95 Sqmm size cable, complete all as specified and directed. 26 M&L Trimming of tree branches upto 20 cm girth from the tree near the LT/HT (33 KV/11 KV/1100V) over head line to provide horizantal clearance of 30 cms and verticle clearance of 60 cms and depositing the trimmed branches where dirrected.Note : All the eqpts required for trimming like vehicle, ladder, axe, manpower etc is deemed to be included in quoted rate 27 Dismantling /disconnecting & taking down insulaters of any size & capacity. 28 M&L for Pin type Porcelain, vitreous, white brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 50mm height, 100 mm dia for 1100 volts grade. 29 Shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, 75mm height, 90 mm dia for 1100 volts grade. 30 S & F in repair cross arms bracing supports, clamps and back plate fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat of red oxide zinc chrome, one under coat and one finishing coat of aluminum paint all as specified. 31 Earthing complete with GIearth plate electrode 600cmX600cmX3.15mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level)with top edge of the plate not less than 1.5 metres below normal groundlevel, connected to GI strip earth lead strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-3 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15 mm bore GI medium grade earth lead protection pipe, 50 mm thick RCC 1:2:4 type B-1 cover slab of earth pit reinforced with 8 mm dia TMT bars @ 10 cm C/C both ways and with handle made out of 10 mm dia bars, funnel, strainer,charcoal and testing on completion all as specified and directed. Note- Rate quoted deemed to be include excavation and earth work in any type of soil with PCC type B2 in pit PCC Cover & other arrangement complete all as directed. 32 Supply & fixing in repair of Bsubar chamber with pure copper strips of size 36 x 18 x6 of 500 Amps HSN Code: 8536 complete all as specified and as directed. 33 Supply & fixing in repair of Bsubar chamber with pure copper strips of size 36 x 18 x6 of 400 Amps HSN Code: 8536 complete all as specified and as directed. 34 M&L PVC spacer suitable for 4/3 wire LT OH lineincluding taking down of old one. 35 Dismantling and removal of ACSR conductor any size from the pole and restringing the same with insulator including replacement of binding wire chopping of trees branches (coming in the way/line) complete all as directed by Engr-in-Charge. 36 Dismantling of ACSR of any size from pole, cross arms, insulators, etc . 37 S&F in repair ACSR conductor of(weasel) 6/1 X 2.59mm, streching properly on insulators and binding with aluminium binding wires, jumpers including fixing on insulators on each poles in span and tightening with permissible sag in between span etc complete all as specified and as directed by Engineer-in-charge 38 Supply only lugs or thimbles suitable for 10 Sqmm to 70 sqmm aluminum coductor cable suitable 1100 volts LT Cable. 39 Supply only Lugs or thimbles suitable for 95 Sqmm to 240 sqmm aluminum coductor cable suitable 1100 volts LT Cable. 40 Supplying Only PVC flat twin core cable PVC insulated aluminium conductor size 4 sqmm 2 core. 41 Supplying Only PVC flat twin core cable PVC insulated aluminium conductor size 6 sqmm 2 core. 42 Supplying Only PVC flat twin core cable PVC insulated aluminium conductor size 10 sqmm 2 core. 43 Supplying Only flat twin core cable PVC insulated aluminium conductor size 16 sqmmm 2 core. 44 Supplying Only flat twin core cable PVC insulated aluminium conductor size 16 sqmmm 2 core. 45 Supplying OnlyMSCable tray of size 10 cm size . 46 Supplying OnlyMSCable tray of size 15 cm size . 47 S & F MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA 48 S & F MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA 49 S & F MCCB 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA 50 Repair /ReplacementLED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete withIP 65/66 protection complete. Make:- Havells or equivalent approved in CG/Philips 51 Repair /ReplacementLED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete withIP 65/66 protection complete. Make:- Havells or equivalent approved in CG/Philips 52 Repair /ReplacementLED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete withIP 65/66 protection complete. Make:- Havells or equivalent approved in CG/Philips 53 Note:- Schedule of credit Rs 77,510.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents.