Tender For Provn Of Fol Storage Dump With Allied Works For Asc At Dalhousie; 1 Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in hard/dense soil, complete all as specified and directed. 2 All as per item No.31 above but depth exceeding 1.5m and not exceeding 3 m 3 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25Cm, complete all as specified and directed. 4 Removing excavated materials/ soils, not exceeding 50mtrs and depositing where directed at a level not exceeding 1.50mtrs, complete all as specified and directed. 5 Spreading and levelling in layers not exc. 25cm thick well ramming including wateringas required for earth filling under floor, complete all as specified and directed. 6 Excavation in post holes (or similar holes) each not exc. 0.50 cum, in hard and dense soil and getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exc. 25cm, watering and removal of excavated materials to a distance n. exc. 50m and making good surfaces, complete all as specified & directed. 7 Hard core of broken stone or boulders of gauge not exc 63 mm deposited ,spread and leveled in layer not exc 15 cm thick complete all as specified and directed. 8 PCC 1:4:8 (nominal mix) type D-2(using 40mm graded crushed stone aggregates) as in foundation filling and mass concretecomplete all as specified and directed. 9 PCC 1:3:6 (nominal mix) type C-2(using 40mm graded crushed stone aggregates) as in foundation filling and mass concretecomplete all as specified and directed. 10 PCC 1:2:4 (nominal mix) type B-2(using 40mm graded crushed stone aggregates) as in coping of pole, including necessary form work,complete all as specified and directed. 11 RCC M-25 (Designmix) (using 20 mm graded crushed stoneaggregates ) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basementslabs, under-reamed piles and mass concrete complete all as specified and directed. 12 RCC M-25 (Designmix) (using 20 mm graded crushed stoneaggregates ) as in Columns, pillars, piers, posts and struts complete all as specified and directed. 13 RCC M-25 (Designmix)(using 20 mm graded crushed stoneaggregates ) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. 14 Use & waste of formwork to sides of concretefoundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or tobatterfor rough finished surfaces of concrete flat, complete all as specified & directed. 15 Use & waste of form work to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc alo splays between floors and beamsfor rough finished surfaces of concrete, complete all as specified & directed. 16 Use & waste of form work to Formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces of concrete for Square, rectangular or polygonal surface, complete all as specified & directed. 17 Brick work with old size fly ash bricks, class 7.5, straight or curved on plan exc. 6 metre mean radius built in cement mortar 1:6 (01 cement : 06 coarse sand) all as specified & directed. 18 Brick work with old size fly ash bricks, class 7.5, straight or curved on plan exc. 6 metre mean radius built in cement mortar 1:4 (01 cement : 04 coarse sand) all as specified & directed. 19 Pressed steel frame using 1.25 mm thick PBI sheet (size of frame 125 x 60 mm) for doors with one or more rebates including necessary fixing lugs, hinges, lock/ strike plate etc and filling with PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregates) as in back of chowkatscomplete all as specified. 20 35mm thicksecond class hardwood (Sal/Hollock) factory made plain framed panelled shutter (two panel) with lock rails & panel of 9 mm B.W.P commercial ply wood or 12 mm thick veneered particle board with commercial veneering on both side. The size of rail and stile as per IS:1003(Part-I) kiln seasoned andchemically pressure treated complete all as specified and directed. 21 300mm longaluminium alloy, anodized, sliding door bolt with hasp, staple(bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed. 22 Extruded aluminium alloy handles, fabricated type, anodised of size 150 mm complete all as specified and directed. 23 Aluminium anodizedbarrel tower bolt of extruded section of size 200 mm and fixed complete all as specified and directed. 24 Prepainted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified, all as specified and directed. 25 Prepainted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge, hips, valley/ eaves/ rain water gutters, drip and straight flashing (length and girthas fixed), fixed with self tapping screws all as specified 26 Rolled mild steel work as in Joist, channel, angle, or tee sections, fixed independently, withoutconnecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated). conforming to grade Fe 410 -W (Gde-E- 250) quality-A, complete all as specified and as directed. 27 Rolled mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to grade Fe 410 -W (Gde-E- 250) quality-A, complete all as specified and as directed. 28 Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooksand hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete. conforming to grade Fe 410 -W (Gde-E- 250) quality-A, complete all as specified and as directed. 29 Steel rolling shutters (Thickness of laths 1.25mm), with ball bearing, as specified including top cover, anchoring rod, hasp and staple and two coats of synthetic enamel paint over one shop coat of primer; erected in position as indicated, complete: push pull or manual type, complete all as specified and directed. 30 Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,n.exc 5 cm long, dia of shank 5mm to 10 mm all as specified. 31 Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors balusters, nosing to steps including embeding in concrete and screwing etc. curing bolts; posts and struts in fencing including cutting tops to shape as directed,wire etc.: flat iron fillets (for securing wire mesh etc.) inbolting or riveting etc., andsimilar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 32 Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails, straining bolts including securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins, etc., complete all as specified. (each line wire to be measured) complete all as specified and directed. 33 Fixing only chain link fencing including linewires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed. 34 Supply only chain link mild steel galvanisd fencing, conforming to IS 2721,complete all as specified and directed. 35 Mild steel round bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending for tieing of chain link fencing,conforming to Fe.410.Gde-E-250 quality-A or Fe-290 Gde E-165 complete all as specified and as directed. 36 Mild steel TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed. 37 Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers bent to shape required, including cranking, bending spirally for hooping for columns, hooking endsand binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed. 38 100mm thick PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregates) as in sub base complete all as specified and directed. . 39 40 mm thick PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregates)as in floor finish,surface finished even and smooth without using extra cement complete all as specified and directed. 40 Plain cement concrete , 1:3:6, nominal mix, type C-1, using 20mm graded mechanically crushed stone aggregate, 75mthick as in plinth protection etc., surface finished even and smooth without using extra cement and laid to a slope of 1 in 24 in alternate panels n.exc. 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen VG-10 and two parts of heated coarse sand (by volume), all as specified. Note:- The unit rate include for use of form work (straight or curved). 41 Rendering cement plaster 15mm thick in cement mortar 1:4 (1 cement : 4 coarse sand) in two layers (10mm thick first layer and 5mm thick second layer) on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified. 42 Rendering cement plaster 10mm thick in cement mortar 1:6 (1 cement : 6 coarse sand) in two layers (5mm thick first layer and 5mm thick second layer) on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified. 43 Rendering cement plaster 15mm thick in cement mortar 1:6 (1 cement : 6 coarse sand) in two layers (5mm thick first layer and 5mm thick second layer) on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, all as specified. 44 Supply only liquid water proofing admixture, complete all as specified. 45 Preparation of new steel surfaces of any description, over 10cm in width or girth,not otherwise describedand applying two coats of synthetic enamel paintover a coat of red oxide primer complete all as specified and directed. 46 Preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer over and including2mm thick wall care putty (applied in two layers), finished smooth with sand paper complete all as specified and directed. 47 Preparation ofold surfaces of wall by Complete removal of existing treatment and applying two coats ofcement base paint over a coat of alkali resistant primer , complete all as specified and directed. 48 Point wiring with 1.5 Sqmm copper conductor FRLS (Multistrand) PVC insulated ISI Marked unsheathed cable in and including stove enamelled concealed steelconduit not less than 20mm dia,marking with all fittings/ accessories as specified in preamble 1 (a) to (q) of Section 19 of SSR Part-II, under heading point wiring and also including PVC insulated ISI marked unsheathed 1.5 Sqmm copper multistranded conductor FLRS as earth wire (green colour) connected to common earth dolly and including pressed steel fame proof terminal boxes made out of 1.20 mm thick mild steel sheet duly painted with one coat of red oxide primer for mounting of switches, sockets, fan regulators, light fittings etc. covered with 3mm thick plastic laminated sheet (Make Hylum or equivalent ISI marked) for one light point or one fan point or one fan point through regulator or one bell point, controlled by one way switch/ push button complete including making good disturbed surfaces to match with existing all as specified and directed. 49 All as per serial item No 104 above, but for one 3 pin 5 Ampssocket outlet on the same board all as specified and directed. 50 All as per serial item No 104 above, but for one 3 pin 5 Ampssocket outlet, independent all as specified and directed. 51 All as per serial item No. 104 above but for 3 pin 15 Amps socket out letindependentwith 2.5 Sqmm PVC copper conductor cable and and PVC insulated, unsheathed 2.5 Sqmm stranded copper conductor cable as continuous earth wire, all as specified. 52 Switch piano flush type, single pole, one way, 5 Amps, all as specified. 53 Switch piano flush type, single pole, one way, 15 Amps, all as specified. 54 Socket outlet two & three pin 5 Amp flush type, all as specified. 55 Socket outlet two and three pin, 5 Pin, 5/16Amp flush type controlled by one switch, all as specified. 56 Flame proof/ waether proof flexible stainless steel metallic conduit , 300 mm long, complete all as specified. 57 Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V, complete all as specified. 58 Ceiling rose, 65 mm to 50 mm, two to three terminals, PVC/ Polycarbonate, insulated body fixed on PVC block, all as specified. 59 LED type tube light, 1x20 watt 230 volts wall mounted Inverter LED batten with square profile and polycarbonate channel. Lithium Ion battery with charging time 8hours-10 hours and back up time upto 4 hours,internely pre wired and including connecting up with three core twisted flexible copper conductor cable of suitable size. Make: Havells cat part No. LHEXACP7FN1W020 or equivalent in Appx 60 Sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 4 way, double door, 240 volts with 200 Amp rated bus bar including taking down ICDP/ DBs any type, kit kat fuse, MCBs any type, all as specified. 61 Sheet metal enclosures for DBs when MCBs to be used, single pole and neutral, 4 way, double door, flame proof, 240 volts with 200 Amp rated bus bar including taking down ICDP/ DBs any type, kit kat fuse, MCBs any type, all as specified. 62 Supply and fixing LED light fitting 2x16 Watt flameproof, CMRI certified recommended for gas/ vaporgroup of IIA & IIIB, Zone 1 & 2 and IP 65 protectionwith die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size, complete all as specified. 63 Exhaust fan, 300mm sweep, steel body , Flame proof, AC single Phase. 230V complete with with, blades, and frame and louversincluding provision of cable copper flexible PVC three core 23/0.0076 from ceiling rose to fan, complete all as specified . Note : (i) Quoted rate shall include for making hole in wall for grouting, fixing the fan on outer side of wall with suitable size anchor bolt and making good disturbed surfaces without ant extra cost. 64 MCB SPN 6 to 32 Amp, 240 Volts, 10 KA all as specified. 65 MCB SP 6 to 32 Amp, 240 Volts, 10 KA all as specified. 66 Sand cushioning to under ground cables provided with a layer of sand 8 cms thick before laying the cable and 15 cms thick after laying the cable complete all as specified and directed. 67 Sub class B bricks for covering to cable laid dry flat, with width equal to length of bricks all as specified and directed. 68 GI pipe light grade of size 40 mm dia laid in trenches/ walls including clamps, screws etc, complete all as specified and directed. 69 XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 35 Sqmm, 3.5 core, laid in trenches or passing through pipes, including making necessary connections at both ends, complete all as specified and directed. 70 XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm, 4 core, laid in trenches or passing through pipes, including making necessary connections at both ends, complete all as specified and directed. 71 XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with multi-standard aluminium conductor, 1100 volts grade, cross sectional area 16 Sqmm, 2 core, laid in trenches or passing through pipes, including making necessary connections at both ends, complete all as specified and directed. 72 Steel tubular swaged poles complete with base plate 8mm thick welded with pole, finial taper plug, bolt, nut and screws as specified type 410 SP-31 (9m long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with yellow and black paint alternately on external surface above PCC benching including numbering with black paint and painting with bituminous paint internally complete and externally for portion embedded in PCC, complete all as specified and directed. Note:- Earth work & excavation and PCC shall be measured and paid under respective Items of BOQ. 73 Automatic Street Light Control Switch using Infrared Sensor based NATURE SWITCH for automatic switching of Street Lights. Nature Switch operation should be based on Natural Light Lux* level. Required Illuminance Levelfor Switching ON is ≤ 30 Lux and for Switching OFF ≥ 10 Lux. The Sensor shouldalso have part night operation facility of min. 4 hrs to max. 12 hrs. The Sensor should be capable for handling three phase load of 8 KWwith 03 NosPower Contactor(s), 3 Nos Incoming MCBsand 03 No Outgoing MCBs . Accessories be enclosed in a pole/wall mountable Rust Proof, Electric Shock Proof,Termite proof and FR grade SMC Enclosure conforming to IP54. The circuit shouldalso have provision for Manual Operation (i.e. Sensor By-Pass option). , complete all as specified. 74 SMC cable junction box of size 300x240x105mm, weather proof , IP-55 , having 4 NOs aluminium bus bar of 25x4mm size including fixing of 10Amp MCB SP and clamps , nuts , bolts , washers suitable for fixing to pole/GI pipes including suitable arrangement for cable entry and exit with 2 run of 1.5 sqmm FRLS flexible cable laying through PVC conduit from junction box to street light fitting complete all as specified and directed.Make : Sintex Cat Part No. GSJB-3020 or its equivalent approved make. 75 Rigid Non Metallic PVC Conduit 20mm dia heavey duty, fixed on steel tubular polewith 04 No MS clamps/RM, from junction box to fitting, complete all as specified. 76 High performance IP66, 70W LED Street Light fixture with housing made of die cast aluminum with street optic lens and glass diffuser for uniform light distribution and inbuilt Surge Protection Device (SPD) suitable for bracket of dia Ø 35/40 mm on existing poles with k=6500K complete all as specified and directed.Make: Havells Cat Part No : ENDURASUNDOWNSL70WLED765PASYBOTG or Bajaj Cat Part No - NEXO 84L WH PO PC SD or Orient Cat Part No : LSFT-070-C or its equivalent in Appx 77 Cutting/ grooving on road/hardstanding uopto size not exceeding 20cm in width and not exceeding 60cm in depth for laying of cable through pipe and making good the disturbed surface by using cement concrete 1:2:4 type B-0, using 12.50graded crushed stone aggregate as required complete all as directed. 78 Supply, installation , Commissiong and Testing of totally enclosed Feedar pillar box, outddor type, CPRI approved, LT 440 Volts, 50 Hz , 3 Phase4 wire supply system, double door type, having independent cabin including locking arrangement for each MCCBs, floor mounted factory fabricated weather and vermin proof protection class IP 55 made out of 3.15 mm thick MS Sheet CRCA Sheet on angle iron 50X50X6mm frame of size suitable to incorporate and including following accessories with front and rear opening doors, handle type locking arrangementpowder coated internally and externally shall have angle iron legs made out of angle iron 40x40x6mm and embeded in PCC foundation of size as required or approved by manufacturers in PCC 1:3:6 TypeC-2 , using 40 mm graded crushed stone aggregate ( 150mm below GL and 100mm above GL) as recommended by manufacturer or directed including earth work complete comprising of following:- 79 Incoming:-(a) MCCB having current rating 63 Amps with rupturing cap 25 KA (Adjustable Thermal & fixed Magneticsettings) , AC 415 Volts,three pole,complete with spreader links. (Qty -01 No) 80 Outgoing:-(a) MCCB having current rating 40 Amps with rupturing cap 25 KA (Adjustable Thermal & fixed Magneticsettings) , AC 415 Volts,three pole,complete with spreader links. (Qty -01 No)(b) (a) MCCB having current rating 25 Amps with rupturing cap 16 KA (Adjustable Thermal & fixed Magneticsettings) , AC 415 Volts,three pole,complete with spreader links. (Qty -03 Nos)(c) Digital Ammeter 0-400 AmpsCTs operated flusf Mfd -96 Sqmm digital ,with selector switch and set of three CTs of appropriate ratio- 01 set(d) Digital Voltmeter 0-500 Volts, square , flush mounted -96 Sqmm ,with selector switch - 01 No. (e) LED phase indicator lamp ( Qty- 01 set of three) (f) Digital frequency meter 0-50hz-01 No.(g) 200 Amp rated Bus bar chamber comprising 4 Nos Aluminium Strip bus bars PVC insulated made of aluminium strip of size (40 x 5) mm. PVC sheathed with colour coding. 81 Note : (i) Incoming and outgoing cables shall be fixed with appropriate size of thimble.(ii) Apron shall be provided at bottom of protection of cable to avoid entry of vermins, raptiles.(iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands.(iv) Layout diagram of panel shall be produced by contractor for approval of AGE (I) before placing order to manufacturer and panel shall be brought at site as per approved drawing 82 Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below ground level, connecting to galvanised iron strip 25x 4mm dia (as earth lead), by means of bolt, nuts, check nuts and washer of galvanised and earth wire protected by provision of galvanised iron pipe light grade, 15mm bore including provn of concrete pit in PCC M-15, type B-I using 20mm graded crushed stone aggregates with 40mm thick precast cover of size 550 mm X 550 mm X 75 mm of RCC M-15, type B-I, reinforced with XPM (weight not less than 4 kg/ Sqm) and frame of angle iron 25x25x3mm with lugs 2 Nos and with 6mm dia mild steel bar handle made to shape, galvanised iron medium grade 20mm bore pipe for watering perforated at bottom 1.75 metre long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixingarrangement, funnel, wire mesh and including earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electricalplate No. 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.