Tender For Construction Of Additional Room And Other Misc. Works For Qtr No.R- 1/4 At Chambal Colony , Rvpn Jaipur - 1 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar. (B-14.7.3) 2 B-1/1.8Earth work in excavation by mechanical means Hydraulic excavator/manual means in found trenches or drains not exceeding 1.5 M in width or 10 Sqm on plan including dressing of sides and ramming of bottom lift upto 1.5 Mtr including taking out the excavated soil and depositing and refilling of jhiri with watering and ramming and disposal of surplus excavated soil as directed within a lead of 50 Mtr all kind of soils. 3 B-3/3.1.6P&L in position Cement Concrete incl. Curing compaction etc. of specified Grade Excl.the cost of Centering & Shuttering all works up to Plinth level1:4:8 (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm N.S) 4 4.1Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix 5 4.3Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix 6 4.13.3Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. (Original producers who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786)Thermo-mechanically Treated bars (Conforming of relevent IS code) 7 4.9 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 8 4.10.2 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 9 B-6/6.1.6Random Rubble stone masonry with hard stone in Foundation and aplinth in Cement Sand Mortar above 30 CM thick walls in Cement Mortar 1:6(1 cement:6 sand) 10 B-5/5.2.2 Brick work with F.P.S brick of class designation . 75 in Super Structure above Plinth Level up to floor V level In all shapes and size in CM 1:6 ( 1 cement : 6 coarse sand) 11 B-5/5.8.3Half brick masonry Super Structure above Plinth Level up to floor V level using bricks of designation 75 in CM 1:6( 1 cement : 6 sand ) 12 B-9/9.5 P&F T-iron frames for doors windows and ventilators of mild steel Tee section joints mitered and welded with 15x3mm long 10 CM long embedded in CC block 15x10x10 CM of 1:3:6 or with wooden plugs and screw or rawl plug and screws or with fixing clips or with bolts and nuts as reqd,. incl. Fixing of nece. Butt hinges and screw and applying priming coat of appd. Steel primer. 13 B-12/12.3.2Plaster on new surface on walls in Cement Sand Mortar 1:6 incl. Racking of joint etc. complete fine finished 20mm thick 14 B-12/12.3.3 Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc.complete fine finish12mm thick. 15 B-12/12.56 mm thick cement plaster to ceiling of mix 1:3 (1cement : 3-fine sand) 16 7.18. 3 P & F 1st qualityVitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade,laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete. 600x600 mm 17 B-7/7.13 Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 18 B-7/7.12 Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 19 B-8/8.13.2.1Providing &Fixing External Grade board solid core single leaf flush door shutters IS 2202-67 marked using Phenol formal dehydreresin in glue both sides with approved steel fittings complete as per Annexure A 30mm thick commercial veneer both side 20 B-12/12.42Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ). 21 B-12/12.46.1 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade two or more coats on new work 22 B-10/10.22Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 23 B-10/10.17.1Grading roof for water proofing treatment withwater proffing compoundCement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 24 12.22.1Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth complete .new 25 B-12.23 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete 26 providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two chromium plated brass brackets fixed with C.P. brass screws and wooden plugs, etc., wherever necessary complete:20 mm 8.25.2 27 P&F fully paneled/ partly paneled / Single leaf shutter frame for doors as per approved design and drawing with approved ordinary C.P./ Oxidised steel fitting as per Annexure A and width of styles & top rails of 100mm and lock rails width of 150mm and bottom rails of 200mm width including teak wood beading of size 19mmx12mm on both faces complete 30mm thick Sheesham wood Gr I (8.4.2.3-8.11) 28 P&F wood paneling or paneling and glazing in paneled or paneled and glazed shutters for doors, windows and clearstory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured ) paneling for paneled and glazed shutter 25mm to 40mm thick, wire gauge 24 gauge 14 mesh of IS designation 85 gauge of dia 0.56mm8.6.8 29 Carriage of Earth, sand, lime , morrum, mannure or sludge for 5 km (G-4/4.1) 30 Supplying and fixing in walls machine cut and polished stone shelves, tands andin CM 1:3 with machine cut edges :Kota stone minimum 30mm thick. 6.17.3 31 Providing and fixing IS : 3564 marked Aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc. complete. 8.26 32 Extra for providing external lipping with 2ndclass teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13.(B-34/8.14) 33 14.2.2Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge.1: 4: 8 or leaner mix. 34 9.17Providing and fixing M.S. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint 35 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall)20mm nominal outer dia pipes2.37.2 36 2.13.3 P & F 15 mm. Dia Connection Pipe of approved quality/make : (-do-) 450mm 37 1.47.8 P & F Towel Rail or Ring of approved quality/make:C.P. Brass Towel Ring revolving type 38 2.15.3 P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make : Gun-metal 25mm nominal bore. 39 2.15.1 P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make : Gun-metal 15mm nominal bore. 40 3.21.2-3.21.2.1 Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m,10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. 450x 450 depthDeduct for usingbrick work230 mm thick in place of 300 mm thick stone masonry 41 1.20.2P & F Low level Flushing Cistern of 10 litres capacity (IS:2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS:1703 mark) complete including cutting and making good the wall : PVC with PVC bend as per IS:7231. 42 1.52.2P & F Soap Dish or Tray of approved quality/makeC.P. brass heavy and superior quality. 43 2.11.2P & F Ball Cock (IS:1703 Mark) with Rod & P.V.C. Ball complete : Brass wt. Not less than 400 gm. 15mm. 44 1.59 P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. 45 P & F water closet Seat Covers with brass hinges complete : Solid PVC (IS 2548 marked) grade-I White for EWC.1.7.2 46 P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc.C.P. Inlet connection 15mm.Brass (IS : 8931 marked)2.12.1 47 P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: (-do-) Long body, 15mm nominal bore weight not less than 690 gm 2.7.4 48 P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: C.P. Brass bib cock,15mm nominal bore.2.7.3 49 P&F looking mirrors with PVC frame of appd. Quality Atul, Modi Guard or equivalent size 500x400mm 1.45.1 50 P & F Grating of approved quality/make:Stainless Steel Sheet size 125mm dia. 1.48.1 51 P & F WVC wash basin (1st quality, I.S. : 2556 Mark) of approved make with C.I. brackets duly painted, 1 No. 15 mm C.P. Pillar cock (IS : 8934 Mark) & 32 mm C.P. brass waste coupling of approved make, 25 mm G.I. waste pipe complete including cutting & making good the wall.: Size 550 mm x 400 mm. 1.36.3 52 P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor1..3 53 Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead. Depth up to 0.5 M Deductfor using brick work 230 mm thick in place of 300 mm thick stone masonry . 3.19.1-3.19.3 54 P & F Square-mouth gully trap `A` grade (IS 651-1992 :marked) of approved make complete with C.I. grating, frame & Cover masonary chamber in C.M. 1:6, 100mm thick C.C. 1:5:10 base concrete, 40mm thick C.C.M-15 grade coping, 12mm thick cement plaster in CM 1:3 complete as per approved design & type.Trap size 150 X 100mm, ferrow cement cover with frame, Internal Chamber size 300 X 300mm.3.5.1 55 3.16.3 P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 110 mm 56 3.17.9P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: bend 87.5110 mm 57 3.17.15P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: clip 110 mm 58 P & F PVC Storage Tank (IS:12701 marked indicating the BIS license No.) of approved make with cover, 25 mm dia 1 M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc. complete of approved design.(S-24 /2.26 )500 (liters capacity). 59 S-9/1.55.3 Bath shower of approved quality / make C.P. brass of heavy and superior quality 150mm revolving with adjustable key 60 S-9/1.54.1 P & F Shower arm 15mm dia of approved quality/make. C.P.brass heavy & superior quality 150mm Projection 61 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work concealed l)20mm nominal outer dia pipes 2.38.2 62 providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make 110 mm dia 3.44.2 63 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /makeDoor Bend 87.5 Dg.110mm dia 3.45.4 64 P & F Towel Rail or Ring of approved quality/make: C.P. Brass Towel Ring revolving type1.47.8 65 15.25Providing and fixing in CM 1 : 4 double paitam (rebated) stone door window and ventilator frames of approved quarry:Size 125 x 100mm 66 Providing and fixing stone slabs table rubbed, 15-18 mm thick in Walls, Steps, Pillars, Counters, Jambs, Shelves, Sills etc. laid on 12mm (Av.) thick base of CM 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.Above 3601 Cm2 Slabs green marble 67 12.43.2Painting exterior surface ofWallwith 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty,etc complete in all respect including scaffolding and safety provision oldWork 68 2.21.1 P & F Mixing Range (15mm)C.P. One hole/close hole basin mixer with casted spout. 69 2.21.5 P & F Mixing Range (15mm)C.P. valve mixer non-telephonic type. 70 5.3.2Add extra forinSquare or Rectangular pillars upto 45 cm pillar two corner areare free 71 7.5.2.iii Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. south red Above 3601 Cm2 Slabs 72 12.40.1Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: new work 73 10.29Providing & fixing 12 mm thick tegular edge Glass Fibre Reinforced Gypsum False ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm/sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-Charge. 74 16.49 Providing and fixing of UPVC casement openable windows (outward / inward): Outer Frame made from the Extruded UPVC Windows profile section of size 60w X 60h mm having outer wall thickness of 2.5mm (+/- 0.2mm) and three chamber constuction, White in finish, duly reinforced with 1.5mm thick GI section. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side. Fix Mullion made of 60w X 80h mm UPVC profile section with steel reinforcement shall be provided in windows having 2 or more openable shutters, as per the requirement. Frame shall have co-extruded with EPDM/TPE-E gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter.Shutter: The shutter of outward openable window shall be made of size 60w X 74h mm and shutter of inward openable window shall be made of size 60w x 77h mm Extruded 3 box multi-chamber UPVC Window profile section of white colour having outer wall thickness of 2.25mm (+/- 0.2mm) provided with reinforcement of 1.5mm thick GI section duly mitered cut & thermal welded at all corners and fitted with UPVC glazing bead of size 36 X 20mm with inner and outer co-extruded EPDM/TPE-E weather seal gasket alongwith 6mm thick ISI make plain float glass. All welding joints of frame and shutter shall be cleaned and milled with the CNC mechainism to provide uniform grooved finish on all visible jaints. Hardware: Window shutter are fixed with frame on 2.5mmthick SS301 Grade friction hinge system to keep the window opened at desird angle. Friction Hinge also enables easy cleaning of glass on both side from the inside of building. 75 16.5.2Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.)With float glass panes of 5.0 mm thickness ( weight not less than 13.50 kg/sqm) 76 7.15 ExtraforusingMarbleprinted/Graniteshadeordarkshadetilesinsteadofwhite,grey,ivory,fumeredbrown,lightgreen,lightblueandotherlightshadesinglazedtilesandMATfinishedtiles.(B-7.16)(A) Mat finished tiles 77 7.15ExtraforusingMarbleprinted/Graniteshadeordarkshadetilesinsteadofwhite,grey,ivory,fumeredbrown,lightgreen,lightblueandotherlightshadesinglazedtilesandMATfinishedtiles.(B-7.16) (B) Glazed tiles 78 3.8 Providing&fixingprecastcementconcretecoping1:2:4mix50mmthickcompleteas per specification : 79 9.8 Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide 80 9.8.1 Extra if square,rectangular hollow tubelarsections are used or grill made by flats only 81 7.22.1P & F 1st qualityHeavy Duty Vitrified Polished Digital tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. 298 mm x298 mm 82 14.23.2Dismantling tile work in floors and roofs laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meter lead:For thickness of tiles 25mm to 40mm.(B-14.23.2) 83 2.49P&F Divertors in water supply lines for walls, wash basin etc 84 2.43Providing and fixing premium quality Two way Bib cock 15mmwith wall flange complete as per sample approved by Engineer in charge 85 2.40Providing and fixingPremium quality Towel rack 600mm long 260mm wide with lower hangers CP Brassfittings of approved make as per direction of Engineer-in-charge 86 2.33.21 Providing and fixingSuperior quality CP Brassfittings of approved make as per direction of Engineer-in-chargeHand shower with 8 mm dia 1 mt long PVC tube & wall hook complete 87 2.33.22 Providing and fixingSuperior quality CP Brassfittings of approved make as per direction of Engineer-in-chargeHealthfocet (Premium heavy Quality) as approved by Engineer-in-Charge 88 2.33.23Providing and fixingSuperior quality CP Brassfittings of approved make as per direction of Engineer-in-charge Jet Spray(Premium heavy Quality) as approved by Engineer-in-Charge 89 2.33.2Providing and fixingSuperior quality CP Brassfittings of approved make as per direction of Engineer-in-charge Swan neck pillar cock 15 mm nominal size 90 2.33.4 Providing and fixingSuperior quality CP Brassfittings of approved make as per direction of Engineer-in-charge Long body Bib Cock 15 mm nominal size 91 2.33.5 Providing and fixingSuperior quality CP Brassfittings of approved make as per direction of Engineer-in-charge Two way Bib Cock 15 mm nominal size 92 2.33.12 Providing and fixingSuperior quality CP Brassfittings of approved make as per direction of Engineer-in-chargeCentral hole basin mixer 93 2.33.13Providing and fixingSuperior quality CP Brassfittings of approved make as per direction of Engineer-in-chargeWall mixer 3 in 1 system with provision of tetephonic bath shower with bend pipe 94 2.33.14 Providing and fixingSuperior quality CP Brassfittings of approved make as per direction of Engineer-in-charge600 mm long towel rail 95 2.33.15Providing and fixingSuperior quality CP Brassfittings of approved make as per direction of Engineer-in-chargeRevolving type towel ring 96 2.33.16Providing and fixingSuperior quality CP Brassfittings of approved make as per direction of Engineer-in-charge Soap dish 97 2.33.18Providing and fixingSuperior quality CP Brassfittings of approved make as per direction of Engineer-in-charge190 mm rain shower 98 2.33.19 Providing and fixingSuperior quality CP Brassfittings of approved make as per direction of Engineer-in-charge Shower arm 99 2.33.20Providing and fixingSuperior quality CP Brassfittings of approved make as per direction of Engineer-in-chargePaper holder 100 2.33.11 Single lever wash basin mixer with 450 mm long copperconnection pipe 101 P& F waste Pipe with all fitting P.V.C with C.Pnut 32 mm(S-1.43.1) 102 Providing & Fixing Premium Quality white glazed vitreous china Sanitary Wares (IS:2556 Mark) of approved make as per direction of Engineer-in-charge including cutting and making good the wall and floor.Double Syphonic European W.C. with mounted W.V.C. flushing cistern of 10 litre capacity complete with all necessary internal fittings with Hydraulic seat cover. 1.68.4 103 Providing & Fixing premium qulaityWVC Wash basin with C.I. brackets duly painted & 32 mm C.P. brass waste coupling of approved make with PVCwaste pipe completeSize 550 mm x 400 mm dia for counter top. 1.71.2 104 P & F PVC Storage Tank (IS:12701 marked indicating the BIS license No.) of approved make with cover, 25 mm dia 1 M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc. complete of approved design.(S-24 /2.26 )1000 (liters capacity). 105 Construction of Cement Concrete Chamber 125mm dia. Stainless Steel Sheet Grating (S-3.38.4) 106 7.15 Extraforusingsize above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finishedtiles in place of 300mm x 300mm size. 107 Supply & Fixing of superior quality wall covering decorative paper of composition of paper and synthetic blend and providing material such as fevicol, cmc powder, chemical and water for fixing the wall paper as per enclosed photograph and direction Engineer-in Charge.16.57 108 9.2Structural steel work riveted,bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete 109 12.40.2Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:old work ono or more coats ) 110 Providing & Fixing of ward robe shutters made out of 19mm thick BWP block board ISI of superior quality make with following details :-Front side finishing with 1mm thick superior quality mica approved make and 0.8mm thickapproved shade mica in the inner side. Covering with teak wood beading 25x12mm all the sides of shutter & 35x12mm on outer frame for making good the wall joint including heavy brass S.S. fittings (Handle 200mm 2 Nos., Tower Bolt 150mm 2 Nos., Brass Lock 1 Nos., Magnetic Catcher 2 Nos., Brass Hinges 75x40x2.5 mm 6 Nos., SS Hanger Rod 20mm dia)complete as per drawing and design approved by Engineer in Charge. 8.34 111 Providing and fixing of openable uPVC Doors with or without fix top: Frame Made of Extruded uPVC Window Profile Section of size 60w x 70h mm having outer wall thickness of 2.75mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2mm thick GI section. All the corners shall be mitered cut & thermal welded so as to form door frame. Fix Mullion made of 60w x 80h mm uPVC Profile Section with steel reinforcement shall be provided for the top fix portion of the doors or in case of the doors having more than two openable shutters, as per the requirement / drawing. Frame of openable door shall have „O‟ type EPDM gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. Shutter : The shutters of openable door shall be made of 60w x 95h mm Extruded 3 box multi-chamber uPVC Window Profile Section of white colour having outer wall thickness of 2.75mm (+/- 0.2mm) provided with reinforcement of 2.0 mm thick GI section duly mitered cut & thermal welded at all corners, provided with center mullion (if specified in drawing) of size 60w x 80h mm uPVC Profile Section and fitted with uPVC glazingbead of size 36 x 20mm with inner and outer co-extruded EPDM/TPE-E weather seal gaskets alongwith 6mm thick ISI make plain float glass.16.53 112 15.30 Providing & applying one coat of UV resistant polymer cement based waterproofing slurry coating of approved make and quality on concrete or plastered surface as perspecifications including preparation of surface by cleaning brushing and dust removing, filling of cracks and making the surface leak proof by mixing one part of chemicalwith 2 parts of cement and 2 parts of water (covering area 1.86 Sq.M/Kg of chemical) including cost of cement, labour, tools & plant, scaffolding if necessary etc., complete as directed by Engineer in Charge.Note: Undulations/cracks found on the surface should be rectified with Cement Motor before application and the same will be paid under relavent items. 113 1.74P&F Looking Mirror 5mm thick of approved make with ornamental frame size 50x12 with 6mm Ply Board on Back Side Complete as per approved sample 114 10.1.3 Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces)excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required.0.63 mm thick with zinc coating not less than 275 gm/m2