Repairs & Maintenance Contract for Preventive & Routine maintenance of HT and LT Lines ,Substations, Transformers, Distribution Panels and feeder pillers etc. at Savitribai Phule Pune university.- 1 DismentlingDismantling the existing cables of all types & size up to 10 sq mm. 2 Dismantling the existing cables of all types & size above 10 sq mm up to 50 sq.mm. 3 Dismantling the existing cables of all types & size above 50 sq mm. 4 Refilling the holes for dismantled cables with cement mortar & finishing etc. complete 5 Dismantling the existing underground cable without damaging it with glands, cable end box including refilling the trench up to ground level and making coils complete. 6 Dismantling the existing pole up to 6 m height with brackets, clamps, insulators, stay from the c.c. foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level. 7 Dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the c.c. foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level. 8 Dismantling the existing overhead line including G.I. wires of all sizes without damaging & making the coils in suitable sizes. 9 Dismantling the existing lightning arrestor set, insulator from DP structure complete. 10 Dismantling the existing switchgears, DB, and bus bar of any size complete with/ without board or angle iron frame 11 Making the site clear of dismantled DB and switchgears by refilling the holes with cement mortar & finishing in an approved manner. 12 Dismantling existing OCB, ACB, LBS, VCB complete from existing panel board in an approved manner. 13 Dismantling any type of unserviceable feeder pillar, switch gear panel, capacitor panel, metering panel, bus-bar panel, electronic equipment panel, etc. and making the site as required, Approx. size (up to 150 cm x 70 cm x 45 cm ) - Small Cupboard 14 Dismantling any type of unserviceable feeder pillar, switch gear panel, capacitor panel, metering panel, bus-bar panel, electronic equipment panel, etc. and making the site as required, Approx. size (up to 200cm. x 90 cm x 45 cm and above) - Big Cupboard 15 Dismantling the existing distribution transformer of any capacity from the plinth / foundation safely without any damages. 16 Dismantling existing pole mounted distribution transformer safely without any damages. 17 Dismantling existing DO / AB switch set complete from D.P. structure in an approved manner. 18 Cable fault detection for all types of LT underground cable from 16sq. mm. to400 sq. mm. by acoustic method by using surge wave tester & surge wave receiver (Duo phone) up to 250 meter length cable with recording results & submission of test reports. 19 11kV/22kV/33kV Cable fault detection for HT power underground cable from 35 sq. mm. to 400 sq. mm. by acoustic method by using surge wave tester & surge wave receiver (Duo phone) up to 250 meter length cable with recording results & submission of test reports. 20 11kV/22kV/33kV Cable fault detection for HT power underground cable from 35 sq. mm. to 400 sq. mm. by acoustic method by using surge wave tester & surge wave receiver (Duo phone) 251 meter to 500 meter length cable with recording results & submission of test reports 21 Supplying and erecting 11 kV outdoor type gang operated air break, triple pole switch 200 A capacity with 3 post pin type insulator per phase, mounted in horizontal or vertical position with necessary channels on providedcross arm with adequate length of C class G.l. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground level with necessary clamp. 22 Supplying and erecting 11 kV outdoor type gang operated air break, triple pole switch 400 A capacity with 3 post pin type insulator per phase, mounted in horizontal or vertical position with necessary channels on providedcross arm with adequate length of C class G.l. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground level with necessary clamp. 23 HIRED BASIS:Providing and maintaining distribution transformer 11kV / 22 kV on HV side & 415 V on LV side from 250 to 500 kVA Capacity Indoor/outdoor type as per IS 1180 for ten days on hired basis. 24 Providing and maintaining distribution transformer 11/ 22 kV on HV side 415V on LV side having 630 kVA capacity Indoor/outdoor type as per IS 1180 onhired basis subsequent to first ten days after commissioning. 25 Erecting 11kV / 22 kV on HV side & 415 V on LV side up to 630 kVA capacityhired/ provided transformer on existing plinth / DP structure, making connections on HV & LV side, carrying out necessary tests before and after charging up to full load to satisfaction. 26 Inspection of faulty distribution transformer 11kV / 22kV on HV side, 415 V on LV side up to 500 kVA capacity in workshop in presence of authority by opening top cover, disconnecting HV & LV studs, tap changer connections; taking out core along with winding for inspection and carrying out necessary tests on HV, LV side, oil, tap-changer etc. checking breather, body condition etc. and submitting inspection report, test reports (oil, insulation, resistance, ratio, etc.) and quotation for repairs complete. 27 Rewainding the 315 to 630 kVA ,3 phase,50 c/s oil immersed and naturally cooled indoor /outdoor type copper wound transformer all makes including minor repairs,replacing, Loading & unloading,Transportation of To & Fro,Dimantling of all winding & core ,Replacement of New winding of H.V. primary coil with DPC wire ,Re winding of L.V. Secondary coil ,Rewinding of H.V. coil with Insulation paper,Assembly of transformer ,Insulations of transformer. ,Oven & heating of transformer ,Tanking of transformer,Replacement of studs & busing of H.V. & L.V ,topping up filtrated transformer oil of approved make with test certificate,Painting oftransformer,Testing of transformer A) open shortB) Magnetic balanceC) Ratio testD) High Voltage testE) No load testF) Oil testwith Scrap credit part with warranty certificate includingall other works and repairs of transformer.(As per IS 2026) 28 Filtration of Transformer oil on site till satisfactory test results. 29 Supplying and topping up new transformer oil of approved make with test certificate. 30 Transportation of 11/22 kV transformer up to 315 kVA without loading & unloading (for handing over to section store/ repair works only) 31 Transportation of 11/22 kV transformer above 315 kVA to 1000 kVA withoutloading & unloading (for handing over to section store/ repair works only) 32 HT CABLES :Supplying , erecting & terminating 11 kV(E), 3 x 70 sq. mm., aluminium conductor XLPE insulated, galvanised steel formed wire armoured (strip) cable laid in provided trench / pipe as per specification no. CB-HT 33 Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT 34 Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 120 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT 35 Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 150 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT 36 Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 185 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT 37 Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 240 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT 38 Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 300 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT 39 Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 400 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT 40 TERMINATION KIT HT Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x up to 95 sq. mm. with necessary material as per specification no. CB-JT/HT 41 Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT 42 Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x240 to 300 sq. mm. with necessary material as per specification no. CB-JT/HT 43 Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x400 sq. mm. with necessary material as per specification no. CB-JT/HT 44 Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE HT cable 3 x up to 95 sq. mm. with necessary material as per specification No. CB-JT/HT 45 Providing and erecting Heat shrinkable outdoor termination kit for 11 kV ( E )XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT 46 Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE HT cable 3x240 to 300 sq. mm. with necessary material as per specification no. CB-JT/HT 47 Providing and erecting Heat shrinkable outdoor termination kit for 11 kV ( E )XLPE HT cable 3x400 sq. mm. with necessary material as per specification no.CB-JT/HT 48 JOINT KIT HT Providing and erecting Heat shrinkable straight through joint kit for 11 kV ( E) XLPE HT cable 3x up to 95 sq. mm. with necessary material as per specification no. CB-JT/HT 49 Providing and erecting Heat shrinkable straight through joint kit for 11 kV ( E) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT 50 Providing and erecting Heat shrinkable straight through joint kit for 11 kV ( E) XLPE HT cable 3x240 to 400 sq. mm. with necessary material as per specification no. CB-JT/HT 51 Supplying and erecting porcelain pin type insulator with GI pin suitable for 11kV line, complete as per specification no. OH-INS/PN 52 LT CABLES : Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 53 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 54 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as perpecification no. CB-LT/AL 55 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 56 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 57 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 58 Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable 1100 V, 4 core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 59 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 150 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 60 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 61 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 240 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 62 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 63 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 35 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 64 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 50 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 65 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 66 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 67 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 68 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 150 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 69 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 70 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½core 240 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 71 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 72 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½core 400 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 73 Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x up to 95 sq. mm. with necessary material as per specification no. CB-JT/HT 74 Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT 75 Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x240 to 300 sq. mm. with necessary material as per specification no. CB-JT/HT 76 Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x400 sq. mm. with necessary material as per specification no. CB-JT/HT 77 Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E ) XLPE HT cable 3 x up to 95 sq. mm. with necessary material as per specification No. CB-JT/HT 78 Providing and erecting Heat shrinkable outdoor termination kit for 11 kV ( E )XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT 79 Providing and erecting Heat shrinkable out door termination kit for 11 kV ( E) XLPE HT cable 3x240 to 300 sq. mm. with necessary material as per specification no. CB-JT/HT 80 Providing and erecting Heat shrinkable outdoor termination kit for 11 kV ( E )XLPE HT cable 3x400 sq. mm. with necessary material as per specification no.CB-JT/HT 81 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 82 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid inprovided trench/ pipe as per specification no. CB-LT/CU 83 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 84 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 85 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 86 TERMINATION KIT LTProvidingHeat shrinkable straight through joint kit for LT XLPE / PVC Armourd cable3½ x 25 to 50 Sq.mm with necessary material 87 ProvidingHeat shrinkable straight through joint kit for LT XLPE / PVC Armourd cable 3½ x 70 to 95 Sq.mm with necessary material 88 ProvidingHeat shrinkable straight through joint kit for LT XLPE / PVC Armourd cable 3½ x 120 to 185 Sq.mm with necessary material 89 ProvidingHeat shrinkable straight through joint kit for LT XLPE / PVC Armourd cable 3½ x 240 Sq.mm with necessary material 90 ProvidingHeat shrinkable straight through joint kit for LT XLPE / PVC Armourd cable 3½ x 300 Sq.mm with necessary material 91 Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 25 to 50 sq mm., with necessary material as per specification No. CB-JT/LT 92 Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 70 to 95 sq mm., with necessary material as per specification No. CB-JT/LT 93 Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 120 to 185 sq. mm., with necessary material as per specification No. CB-JT/LT 94 Providing & erecting epoxy straight through joint outdoor/indoor for LT XLPE armoured cable 240 sq.mm., with necessary material as per specificationNo. CB-JT/LT 95 CBSupplying, installing, testing and commissioning air circuit breaker manual fixed type, non-drawout type, 650V, 800A, rated at 50º C without deration, 12kVImpulse, 4 pole (100% Neutral Protection), 50 kA (Ics=Icu=Icw for 1s), with standard accessories with ready to close, individual fault trip, alarm and trip indications, mechanical and electrical anti pumping, soft/ hard rating plug (including hard rating plug CT) with Micro-processer based LCD display release with LSIG and temperature rise protection & with 4 C/O contacts for On-Off-Trip indication, min. 5 event and trip history on breaker display on provided iron frame as per specification no. SW-SWR/ACB 96 Providing maintenance of ACB of all range with ACB maintenance kit by ACB manufacturer consisting of all the essential consumables like greases, cleaning spray, dusters, scrubbers and hardware required and carrying out necessary corrective maintenance of ACB complete. (excluding required spare prices) 97 Providing maintenance of RMU,LBS of all range consisting of all the essential consumables like greases, cleaning spray, dusters, scrubbers and hardware required and carrying out necessary corrective maintenance of RMU/LBS complete. 98 Supplying, installation, testing and commissioning extendable/non-extendableindoor type 11 kV, 630A, load break switch, compliant to IEC 62271 -100, 200 and 102, on provided MS channels/trench /foundations per specification no SWHTS/ LBS 99 Supplying, installation, testing and commissioning extendable/non-extendableoutdoor type 11 kV 630A, load break isolator switch, compliant to IEC 62271 - 100, 200 and 102,on provided MS channels/ trench/ foundation as per specification no SW-HTS / LBS 100 Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 101 Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 102 Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 103 Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 104 Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB 105 Supplying, erecting & commissioning 4 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as perspecification no. SW-RCCB/RCCB 106 Providing & erecting 3 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand site capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 107 Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW SWR/MCCB 108 Providing & erecting 3 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in providedenclosure / panel as per specification no. SW-SWR/MCCB 109 Providing & erecting 3 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW SWR/MCCB 110 Providing & erecting 4 Pole MCCB upto 100A, 415V, with short circuit rating 25 kA (Ics=100% of Icu ),adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB 111 Providing & erecting 4 Pole MCCB of 200A,415V capacity with short circuit rating 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ tripalarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB 112 Providing & erecting 4 Pole MCCB of 250A,415V capacity with short circuit rating 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB 113 Providing & erecting 4 Pole MCCB of 315/400A, 415V capacity with short circuit rating 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW SWR/MCCB 114 Providing & erecting 4 Pole MCCB of 600/630 A, 415V capacity with short circuit rating 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB 115 Supplying and erecting ON LOAD four pole automatic transfer switch, 415V, 100-125A, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 . 116 Supplying and erecting ON LOAD four pole automatic transfer switch, 415V, 200A, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 117 Supplying and erecting ON LOAD four pole automatic transfer switch, 415V, 315A, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging, connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 . 118 Supplying & erecting four pole ON LOAD change over switch, 415V, 160A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3. 119 Supplying & erecting four pole ON LOAD change over switch, 415V, 400A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3. 120 Supplying PVC one way Enclosers Suitablel for DPMCB/TPMCB/FPMCB complet erected on Wooden/ Sumica Board. 121 Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thicknesssuitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erectedon angle iron/GI frame. 122 Supplying and erecting triple pole mini feeder pillar with 500V, 200A FPMCCB as incomer and 2 outgoing circuits with HRC fuse base and cartridge of 100A with aluminium bus bar erected in 14 SWG CRCA sheet box with supporting angles, self locks, gasket having IP54,IK10 protection and slanting top to be erected on provided foundation complete as per specification no. SWSWR/ MFP 123 Supplying and erecting triple pole mini feeder pillar with 500V, 300A FPMCCB as incomer and 3 outgoing circuits with HRC fuse base and cartridge of 100A with aluminium bus bar erected in 14 SWG CRCA sheet box with supporting angles, self locks, gasket having IP54,IK10 protection and slanting top to be erected on provided foundation as per specification no. SW-SWR/MFP 124 Supplying & erecting three phase, 415V, street light control panel up to the max load of 6kW, TPN MCB 40A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation. 125 Supplying & erecting three phase, 415V, street light control panel up to the max load of 12kW, TPN MCB 63A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up,auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation. 126 Supplying4 WAY 440V, 3 phase outdoor type Mini Feeder piller.with busbar,With reqiured fuses, M.S.frame and required acessories. 127 Supplying4 WAY 440V, 3 phase outdoor type Feeder piller.with busbar,With reqiured fuses, with M.S.frame (Stand) and required acessories. 128 SupplyingFloor mounting, 4 pole MCCB LT Feeder Piller suitable for Four Pole one wayIncomingsuitable for FP 800/1000 amp.current carring capacity with aluminium basbar & 4 ways Four pole outgoing with required HRC fuses & locking arrengment on iron frame & including M.S.Stand withincluding cutting,bending, drilling, welding, rivetting etc. treated with anti-rust treament and duly podwer coated or painted with one coat of red lead paint and 2 coats of enamel paint as directed.(Excluding MCCB) 129 Feeder Pillar maintence with proper arrangement of Fuse base,busbars with welding,drilling,Bending,cutting with Hinge fixing, greesing,cleaning & two coats of enamel paint 130 Supplying and erecting static energy meter with 240V 50 Hz. AC supply 5 to 30 A, ISI mark, accuracy class 1.0 with backlit LCD display, (measuring and display kWh, kVAh, V,I,PF, frequency, kW, kVA, six months history of site Energy & MD in kW & kVA) with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proofPVC wires duly tested by electric supply company. 131 Supplying and erecting static energy meter with 240V 50 Hz. AC supply 10 to 60 A, ISI mark, accuracy class 1.0 with backlit LCD display, (measuring and display kWh, kVAh, V,I,PF, frequency, kW, kVA, six months history of Energy & MD in kW & kVA ) with transparent hinge type box completeerected on polished teak wood board duly wired with required size of weather proof PVC wires duly tested by electric supply company. 132 Supplying and erecting static energy meter with 3 x 240V 50 Hz. AC supply 10 to 60 A, ISI mark, accuracy class 1.0 with backlit LCD display, (Measuring and display Trivector, V, I, kW, PF, Hz, Last month history of kWh and MD in kW) with special features like TOD, Tamper logging, OpticalCommunication Port & Display in absence of Power & with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof PVC wires duly tested by electric supply company. 133 Supplying and erecting LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 , 3x240V,50 Hz with optical & RS 232 port, backlit LCD, measure & display trivector energy, load survey, TOD, tamper detection & logging, power ON /OFF events, instantaneous parameters of rating 1/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box and connected to CTs. 134 FUSESSupplying and erecting bakelite fuse fitting suitable for HRC bolted type fuse upto 32A without fuse. 135 Supplying and erecting bakelite fuse fitting suitable for HRC bolted type fuse upto 63A without fuse. 136 Supplying and erecting bakelite fuse fitting suitable for HRC bolted type fuse upto 100A without fuse. 137 Supplying & erecting HRC fuse cartridge 415V 32A complete. 138 Supplying & erecting HRC fuse cartridge 415V 63A complete. 139 Supplying & erecting HRC fuse cartridge 415V 100A complete. 140 Supplying & erecting HRC fuse cartridge 415V 200A complete. 141 Supplying & erecting HRC fuse cartridge 415V 300A complete. 142 Supplying, installing, testing and commissioning 11kV HRC Fuse 10A to 40A for load break switch with necessary nut bolts complete. 143 Supplying and erecting 11 kV HRC fuse 63A for load break switch to be fitted with necessary nut bolts and commissioning complete. 144 Supplying11 kV HRC fuse 125 amp for load break switch to be fitted with necessary nut bolts and commissioning complete. 145 Supplying and erecting, 11 kV outdoor type drop out fuse with insulator complete with fuse holders, fuse barrel with metal fitting, fuse element mounted on M.S. channel with working current of 15A capacity completeerected on provided cross arm. 146 ALUMINIUM LUGS Supplying & erecting crimping type aluminium lugs for cable up to 16 sq. mm. complete as per specification no. CBCL/AL 147 Supplying & erecting crimping type aluminium lugs for cable 25 sq. mm. complete as per specification no. CB-CL/AL 148 Supplying & erecting crimping type aluminium lugs for cable 35 sq. mm. complete as per specification no. CB-CL/AL 149 Supplying & erecting crimping type aluminium lugs for cable 50 sq. mm. complete as per specification no. CB-CL/AL 150 Supplying & erecting crimping type aluminium lugs for cable 70 sq. mm. complete as per specification no. CB-CL/AL 151 Supplying & erecting crimping type aluminium lugs for cable 95 sq. mm. complete as per specification no. CB-CL/AL 152 Supplying & erecting crimping type aluminium lugs for cable 120 sq. mm. complete as per specification no. CB-CL/AL 153 Supplying & erecting crimping type aluminium lugs for cable 150 sq. mm. complete as per specification no. CB-CL/AL 154 Supplying & erecting crimping type aluminium lugs for cable 185 sq. mm. complete as per specification no. CB-CL/AL 155 Supplying & erecting crimping type aluminium lugs for cable 240 sq. mm. complete as per specification no. CB-CL/AL 156 Supplying & erecting crimping type aluminium lugs for cable 300 sq. mm. complete as per specification no. CB-CL/AL 157 Supplying & erecting crimping type aluminium lugs for cable 400 sq. mm. complete as per specification no. CB-CL/AL 158 COPPER LUGS Supplying & erecting crimping type copper lugs for cable up to 16 sq. mm. complete as per specification no. CB-CL/CU 159 Supplying & erecting crimping type copper lugs for cable 25 sq. mm. complete as per specification no. CB-CL/CU 160 Supplying & erecting crimping type copper lugs for cable 35 sq. mm. complete as per specification no. CB-CL/CU 161 Supplying & erecting crimping type copper lugs for cable 50 sq. mm. complete as per specification no. CB-CL/CU 162 EXCAVATIONMaking trench in soft soil having 0.75 m depth and minimum 0.3 m width for laying provided cables up to voltage level of 1.1kV complete As per specification No. CW-EXN-CTR 163 Making trench in Hard murum/Tar road having 0.75 m depth and minimum 0.3mtr width as per IS for laying provided cables up to voltage level 1.1Kv cable complete as per specification No. CW-EXN-CTR 164 Making trench in soft soil having 0.9m depth and minimum 0.3 m width as per IS for laying provided cables of voltage range 3.3 kV to 11 kV complete as per specification No. CW-EXN-CTR 165 Making trench in hard murum/Tar road having 0.9 m depth and minimum 0.3mtr width for laying provided cables of voltage range 3.3 kV to 11 kV complete as per specification No. CW-EXN-CTR 166 Making trench of suitable width and depth in soft soil for laying provided HT/LT cable of 16 sq. mm & above and covered with half round hume pipe complete as per specification no. CW-EXNCTR 167 Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete. 168 Supplying & laying (including excavation) half round reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. 169 Supplying & laying (including excavation) reinforced cement concrete pipe of IS458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slopeincluding providing and fixing collars in cement mortar 1:2 and curing etc. complete. 170 Supplying & laying (including excavation) half round reinforced cement concrete pipe of IS 458:2003 NP-2 class of 250 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. 171 Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. 172 Supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete 173 Supplying and laying (including excavation of suitable width & depth up to 90 cm) 90 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. 174 Supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. 175 Supplying and laying (including excavation of suitable width & depth up to 90 cm) 175 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. 176 EARTHINGProviding earthing with copper earth plate size 30 x 30 x 0.315 cm complete withall materials, testing & recording the results as per specification no. EA-EP 177 Providing earthing with galvanized iron earth plate size 60 x60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials,testing & recording the results as per specification no. EA-EP 178 Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials as per specification no. EA-EP 179 Supply, Installation, Testing and Commissioning of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. Specification no. EA-MOBI 180 Providing earthing with copper earth plate size 60 x 60 x0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials, testing & recording the results as per specification no ESE -LA 181 Supplying and erecting aluminium strip of required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP 182 Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no. EA-EP. 183 Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP. 184 Supplying and erecting Annealed bare copper wire of high purity of different sizes used for earthing on wall with necessary copper clamps fixed on wall/cable/conduit withscrews in an approved manner. 185 Supplying and erecting GI earth wire of high purity of different sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws in an approved manner. 186 Supplying and erecting metal work in CRCA sheet with fabrication of boxes, panel boards, etc. including cutting, bending, drilling,welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete. 187 Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. 188 Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V, 100A having 15mm (Width) X 3 mm (Thickness), with 99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A persq. mm. compliance to IS 5082 and Enclosure fabricated with 16 SWG CRCA sheet and epoxy paint, with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CPBB 189 Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V 200A having 25mm (Width) X 5 mm (Thickness) , with 99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A persq. mm. compliance to IS 5082 and Enclosure fabricated with 16 SWG CRCA sheet and epoxy paint, with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CPBB 190 Supplying and erecting bus bar chamber triple pole with neutral with four copper bars, 500V, 100A having 10mm (Width) X 1.6 mm (Thickness), with 99.9 % Copper purity as per E91E Grade & Current Density 1.6 A per sq. mm. compliance to IS 5082 and Enclosure fabricated with 16 SWG CRCA sheet and epoxy paint, with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CP-BB 191 Supplying and erecting bus bar chamber triple pole with neutral with four copper bars, 500V 200A having 20mm (Width) X 2 mm (Thickness), with 99.9 % Copper purity as per E91E Grade & Current Density 1.6 A per sq. mm. compliance to IS 5082 and Enclosure fabricated with 16 SWG CRCA sheet and epoxy paint, with suitable number of ways and with SMC/DMC Insulators andaccessories of suitable rating complete as per specification no. CP-BB 192 Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware. 193 Supplying & erecting cast iron cable indicator plate buried along with route of cable for PVC / XLPE armoured cable as per specification no. CB-CIP 194 Painting fencing of transformer substation including all supports, iron work and doors from both sides by scrapping existing paint, with one coat of red oxide & two coats of aluminium paint complete. 195 Painting of feeder pillar / switchgears and frame of panel board with single coat of red oxide & two coats of approved quality enamel paint by scrapping existing paint painting the same complete. (while calculating square meter area, area of angle iron frame on which the switchgears are erected shall be considered if required) 196 Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 62.5 kVA up to 82.5 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF. 197 Surveying, Designing, Supplying , erecting, testing & commissioning of 11kV, 630A, 21kA/3sec, 3 Way, Outdoor Extensible SF6 Insulated motorized SCADA compatible RMU as per MSEDCL R-APDRP Specification with 2 No. feeder with Load Break Switch, FPI and 1 No. feeder with VCB, 500VA Aux PT, Battery and battery charger and Right angle boots. | 2LBS+1VCB +1 Metering Module as Bus PT(Set of 03nos. Single Phase Potential Transformers having ratio 11kV/rt3:110V/rt3, 50VA,Class 0.5; Provision for installation of Multifunction Meters for energy reading in breaker functions) 198 Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FS 199 Providing and filling gravel in planting bed as per drawing and technical specifications etc. complete. (Gravel ) 200 Rewinding of electric motor above 25 H.P. upto 30 H.P. three phase up to 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year 201 Kirloskar KS9A-5004 50HP 37kW 125mm Borewell Water Filled Submersible Pump(The Kirloskar KS9A-5004 is a powerful and reliable 50HP (37kW) submersible pump designed for use in borewells. With a solid 125mm borewell capacity, it ensures efficient water flow and a head range of 91-40 meters. The motor cooling type is water filled, ensuring optimal performance and durability. The pumps impeller is made of stainless steel, guaranteeing long-lasting operation even in harsh conditions. With its suction size of 125mm, it can effectively draw water from deep sources. Please note that the image provided is for reference only. Choose Kirloskar for reliable and efficient submersible pumps.) Including Installation and transportation charges 202 Dismantling theMonoblock / open well submersible water pump set centrifugal type without pipeline complete and making the site clear. (Including transportation from site to rewinding shop) 203 Reinstalling theMonoblock / open well submersible water pump set centrifugal type without pipeline complete and making the site clear.(Including transportation from rewinding shop to site) 204 Supplying and erecting SS enclosure for MCCB suitable for above 250 A up to800A MCCB. 205 Providing & erecting 3 Pole MCCB, 415V, 800A, rated short-circuit breaking capacity 50 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in providedenclosure/panel as per specification no. SW-SWR/MCCB 206 Supplying & erecting four pole ON LOAD change over switch, 415V, 315- 320A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3. ( 207 Supplying, erecting & terminating XLPE insulated unarmoured cable 1100 V. 1 core 70 sq. mm. copper conductor complete erected with provided lugs, laid in provided control panel/distribution boards / pipe as per specification no 208 Supplying and erecting terminal spreaders suitable for 4 pole, above 100A up to250A MCCB (Set of 8) 209 Supplying and erecting terminal spreaders suitable for 4 pole, above 630A up to800A MCCB (Set of 8) 210 Rewinding of electric motor above 25 H.P. upto 30 H.P. three phase up to 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year