| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 08-09-2025 | Date corrig 08 Sep | Date | 20-09-2025 |
| 2 | 08-09-2025 | Other Corrigendum and Drawing corrigendum | Other | 20-09-2025 |
| 3 | 01-09-2025 | Other corrigendum | Other | 16-09-2025 |
| 4 | 29-08-2025 | Date corrigendum 29 Aug | Date | 16-09-2025 |
| 5 | 29-08-2025 | Other Corrigendum for Drawings and other | Other | 16-09-2025 |
| 6 | 29-08-2025 | BOQ Corrigendum and other changes | BOQ | 16-09-2025 |
| 7 | 21-08-2025 | Date corrigendum 9 | Date | 11-09-2025 |
| 8 | 13-08-2025 | Date Corrigendum 8 | Date | 02-09-2025 |
| 9 | 04-08-2025 | Date corrigendum 8 | Date | 21-08-2025 |
| 10 | 28-07-2025 | Date corrigendum7 | Date | 12-08-2025 |
| 11 | 21-07-2025 | Date Corrigendum 7 | Date | 05-08-2025 |
| 12 | 08-07-2025 | Date Corrigendum 6 | Date | 29-07-2025 |
| 13 | 30-06-2025 | Date corrigendum 5 | Date | 17-07-2025 |
| 14 | 20-06-2025 | Date corrigendum 4 | Date | 07-07-2025 |
| 15 | 10-06-2025 | Date corrigendum 3 | Date | 27-06-2025 |
| 16 | 22-05-2025 | Date corrigendum2 | Date | 17-06-2025 |
| 17 | 09-05-2025 | Date corrig | Date | 30-05-2025 |
| 18 | 25-04-2025 | Date corrigendum | Date | 20-05-2025 |
| Sl. No. | Item Description |
| 1 | SCHEDULE A PART I (BUILDING WORKS) |
| 2 | Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ Part-I (Sec-I). |
| 3 | Sch ‘A’ Part-I (Sec-II) : Construction of MSE Wall (traverse with toe wall ) complete all as per drawings, specified and as directed. |
| 4 | Sch A Part II (INTERNAL ELECTRIFICATIONS) |
| 5 | Lump sum price worked out by the contractor for Internal Electrification work as listed in Sch ‘A’ Part II. |
| 6 | Sch A Part III(LIGHTENING PROTECTION WORK) |
| 7 | Lump sum price worked out by the contractor for Lightening Protaction work as listed in Sch ‘A’ Part III . |
| 8 | Sch A Part IV (ROAD/PATH AND CULVERT) |
| 9 | Lump sum price worked out by the contractor for Road/ Path/ Culverts work as listed in Sch ‘A’ Part IV . |
| 10 | Sch A Part V (TAXI TRACK LOAD AND NON LOAD BEARING) |
| 11 | Lump sum price worked out by the contractor for Taxi Track Load and Non Load bearing work as listed in Sch ‘A’ Part V. |
| 12 | Sch A Part VI(EXTERNAL WATER SUPPLY WORK) |
| 13 | Lump sum price worked out by the contractor for External Water supply Work as listed in Sch ‘A’ Part VI. |
| 14 | Sch A Part VII (EXTERNAL ELECTRIC SUPPLY WORK) |
| 15 | Lump sum price worked out by the contractor for External Elcetric supply work as listed in Sch ‘A’ Part VII |
| 16 | Sch A Part VIII(AREA DRAINAGE WORK) |
| 17 | Lump sum price worked out by the contractor for Area Drainage work as listed in Sch ‘A’ Part VIII |
| 18 | Sch A Part IX (EARTH WORK AND SITE CLEARANCE WORKS) |
| 19 | Lump sum price worked out by the contractor for Earth work and site clearancework as listed in Sch ‘A’ Part IX |
| 20 | Sch A PartX (Miscellaneous Items of B/R and E/M including DG Set and site clearance and development and MAFI etc) |
| 21 | M & L approved earth/soil obtained from outside MOD land including transportation exc. 1.5 km to n.exc. 5 km, forming embankment including raising or lowering earth, spreading in layers not exceeding 30 cm thick ramming / rolling and finishing to required size shape etc not exceeding 1.5 m high from base soil complete all as specified & directed. Note: The unit rate quoted is deemed toinclusive ofcost of soil including transportation. |
| 22 | Supply and fixing LED based flame proof flood light fixture 250 watt 230 V AC outdoor type new generation energy saving & enviornment friendly long life , pressure die-cast aluminium housing flood light with PC diffused lens enclosure over LED for glare free light with individual LED lenses, 4kV internal and 10kV external surge protection, min 100 lm/watt, colour Temperatur 6000 to 6500 K, PF>0.95, CRI>75, and THD<10, 230 volts AC 50Hzcomplete with internal wiring, accessories and with bracket suitable for mounting on floor complete all as specified and and as directed. |
| 23 | Supply & Fixing flame proof Heavy duty (Fully Metal construction) air circulated wall mounted fan 24\",1800mm sweep, 1440 RPM, 4 speed control with regulator, single phase, 230 volts, AC 50HZ, consisting of power full circulator motor with spiral guard design ensure high air thrust, high torque gear box with safety clutch, broad blade profile for low noise, reseetable thermal overload protecter, oscillating mechanism including making electric connection using flexible twisted copper conductor of suitable size complete all as specified and as directed. |
| 24 | Supply and fixing Flame proof switch socket & plug combined 32 A, 415 V (4P+Earth) complete all as specified and as directed . |
| 25 | Supply and fixing factory made Flame Proof Enclosure size 480x480x250mm FLPLighting distribution Panel, Including :- Incomming MCCB 100Amps-01 Nosand outgoingMCB\"s SP 6 to 32 Amps -21 Nos, MCB TP 32 Amps-01 Nos, 415 Volts, AAC 50Hz,8 way VTPN with complete internal busbar and wiring of copper conductor complete all as specified and as directed. |
| 26 | Supply and fixing factory made Flame ProofEnclosure size 330x350x190mmFLPLighting distribution Panel, Including :- Incomming MCB SPN 32 Amps -01 Nosand outgoingMCB\"s SP 6 to 32 Amps -06 Nos,8 way SPN with complete internal busbar and wiring of copper conductor complete all as specified and as directed. |
| 27 | Supply & Fixing 4 Way Junction Box 100 mm dia complete all as specified and as directed. |
| 28 | Supply & fixing LED security light 100 watt IP - 65 having pressure dia cast aluminum housing with heat resistant toughened glass, individual LED lenses, 4kV internal and 10kV external surge protection, min 100 lm/watt,colour Temperatur 6000 to 6500 K, PF>0.95, CRI>75, and THD<10, 230 volts AC 50Hz with internal wiring with bracket mounting on floor complete all as specified and as directed. |
| 29 | M&L for construction of new valve pit chamber of size 900mm X 900mm X 600mm including necessary earth work in any type of soil , PCC foundation (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in base concrete, brick work in CM 1:6 with 10 mm thick platser internally and 15mm thick externally in CM 1:4 upto 15 mm below NGL , 4 mm thick MS cover with hinges and locking arrangements fixed to angle iron frame made out of 40X40X6 mm MS angles, D type handle complete with 2 coat of synthetic enamel paint over one coat of red oxide primer on all metal works and three coat of white wash on all plastetred surfaces of valve chamberscompleteall as specified and directed by engineer in charge . |
| 30 | M&L for boring of holes under road pavement hardstanding by trenchless techonology using ultra sounding technique and necessary machine including supplying and fixing HDPE pipe of 50mm dia suitable for 0.4 mpa working pressure complete all as specified and directed. |
| 31 | Horizontal Boring under hard standinf/pavement or roads manually usinf suitable auger for insertion of GI pipes up to 100 mm bore and making good the disturbed surface complete all as specified and directed. Note :- GI pipe will be measured and paid separately. |
| 32 | M&L for cutting of the existing GI pipe line 50mm dia and supplying and inserting \"T\"of size 50x50x25mm including necessary fittings, excavation/earth work complete all as specified and directed. |
| 33 | S&F of monobclok pump of capacity 1 HP having power rating of 0.75KW, automatic air release during priming, with IP - 44 protection complete all as specifed and as directed |
| 34 | M & L for laying in trenches brunt brick sub class B for cable protection laid adjacent to each other length wise perpendicular to the central axis of cable complete all as specified and as directed. |
| 35 | Supply and laying un-reinforced precast concerete cable caver, class HVP, type 2 flat size 300mm xm 180mm x 40 mm for covering to under ground cable laid flat transversally width equal to the lenth of the cable complete all as specified and directed. |
| 36 | Supply, installing, testing and commissioning, factory assembled diesel Engine driven generating set, fully wired alternator AC to given an output of 200 KVA continuously rating at a PF of 0.8 lagging, 415 Volts AC 3 phase 4 wire 50 Hz +/-1% supply, 1500 RPM, directly coupled with diesel engine. DG Set will be as per latest CPCB Norms. DG Set shall be water cooled mounted on common base frame complete with fuel tank provided with in canopy on base frame (Service tank) of adequate capacity with fuel line and accssories, PCC foundation work as per manufacturer instructions, vibration and damper pads, control panel and other accessories etc and comprising of the following:-(a) Radiator with blower fan or heat exchanger with guard(b)Pipe coupling for engine cooling system piping(c) Corrosion inhbitor coolant(d)Paper element filters :- (i) Fuel filter (ii) Lubricant oil filter(e)Fly wheel housing and fly wheel to suit alternator(f) Engine bearing machanism in fly wheel housing(g) Shunt off coil with safeties for LLOP/HWT/over speed(h)Dry type air cleaners and vaccum indicators(j) Residential silencers(k) Stainless steel exhaust flexible bellows(l)Battery charging Alternator |
| 37 | (m)Exhaust priming made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary support scaffolding as per manufacturer\"s recommendations to sustain back pressure with rain cap(n)Miniral wool insulation 2\" thick suitable for 400 temperature claded with aluminum sheet of 30 guage for the entire length of the exhaust pipe(o) First fill of oil, coolent and diesel during testing (p) Inter connecting copper cabling of adequate capacity between batteries control(q) Fuel pipe C class STIC 1\"/1.5\"/2\" dia - 01 lot(r)Self starter of suitable capacity(s) Electronicgovernor(t) Fuel injection pump(u) Electronic instrument panel complete with all accessories as per manufacturer specifications displaying the following :- (i)Battery voltage & battery charging indicator. (ii) Water temperature (iii) Lubricating oil pressure (iv)Engine speed (v)Engine hours (vi) Freqency (vii)Voltage(w) Emergency stop butten (x)Safety control (Trip and indication) (i)High water temperature(ii)Low lube oil pressure(y)Base Frame:- Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturer design alongwith AVM pads. |
| 38 | (z) Battery :-01 Nos, 12 Volts, 150AH, maintenance free with leads and terminals (Make :- Exide/Amron) Starting switch on/off(aa)Fuel tank :- Not less then08 Hrs full load diesel storage capacity fuel tanks with mounting brackets factory made of 5 mm thick HR/MS sheet with level indicator fuel outlet, fuel inlet, air vent, drain plug, inlet arrangement for diesel filling from exterior of canopy (without opening its panel etc, complete all as specified.(ab)Alternator :-Suitable rated at 200 KVA at 0.8 PF, 415 Volts, 3 Phase, 4 wire 50 Hz, at 1500 RPM, self excited and self regulated with AVR brushless excitation, screen protected, drip proof, Insulation Class H,IP-23, self ventilated and conforming to BS:5000/IS : 4722 suitable for engine as mentioned here in before. Make : kirloskar/Crompton Greaves(ac) Acoustic Enclosure : Acoustic enclosure of suitable size as per manufacturer design for the above 200 KVA DG Set to reduce noise level to 75dbmeasured at 1.0 m distance for auidable frequencies as per guidelines of central pollution control boardand manufacturer specification and comprising of following from authorized GOEMs of Gen set Manufacturers specified : (i) Sound insulation 100 mm thick rock wool (density 64 kg/cum) (ii) Outer body:1.6 mm thick CRCA(iii)Door : 1.6 mm thick CRCA (iv)Inner surface :1.0 mm thick CRCA/GI sheet (v) Base frame:\"ISMC 300 (vi)Inside illumination:01 No - 1x15 watts LED fitting of make Philips/Bajaj/Crompton (ad)Control Panel:Lt Panel cubical type CPRI approved floor mounted AMF type, madeCRCA Sheet in suitable compartments and thickness, front openable powder coated including the following :- (i)Set of electric bus bar copper 400 A for phase and neutral |
| 39 | (ii)02 Nos contactorswith interlocking of capacity 315 Amp as per existing load of transformer including necessary AMF functions, with suitable accessories like fuses, relays, contactors, copper busbar, etc. (Make Schenieder, Simens, L&T, CG)(iii)set of phase indicating lamps - 01 set(iv) Volt meter digital type 0 to 500 volts range with selector switch - 01 No(v) Ammmeter digital type 0 to 100 Amps range complete with suitable CTsand selector switch - 01 No (vi)KWH meter digital type with suitable CTs - 01 No set (vii)Digital PF meter - 01 No (viii)Indicating lamp for supply on and load on (ix)Instruments fuses (HRC type)(x) Bottom gland plate for incoming and outgoing cable (xi)Circuit diagram plate |
| 40 | Supply, installation , testing and commissiong factory made LT feeder pillar box outdoor type platform mounted of size 1800 mm x1200 mm x 450 mm suitable for 415 Volts 3 phase 4 wire system 50Hz supply having aluminum bus bar 600 Amps for phases and neutral, installed on porcelain / epoxy insulator. the panel shall be dust proof, vermin proof (IP54) and applying spray paintig with two coats of synthetic enameled paint over a coat of red oxide primer on sheet and made of out of 3.15 mm thick CRCA sheet self moulded type and 50x50x6 mm angle iron frame front and rear opening with double shutter and locking arranement with 50mm lock and including grouting of panel with necessary PCC 1:2:4 type B-1 work complete all as specified.The scope of work includes provision of housing the following acceessories:-Incoming :- (i) MCCB having current rating 630 Amp. 4 pole of breaking capacity 36 KA -01 No.(ii) Volt meter 0-500 Volts,Square flush pattern,digital type -01 No.(iii) Amp meter square flush pattern 0-600 Amps digital type-01 No.(iv) Indicating lamp LED type one set in incoming phases.(v) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 volts grade IS 694 marked .(vi) Alarm System for indicate the commercial power failure.Outgoing :- (i) MCCB having current rating 200 Amp, 4 pole of breaking capacity 25 KA,415 volts -02 Nos.(ii) MCCBhaving current rating 160 Amp, 4 pole, of breaking capacity 25 KA, 415 volts -01 No. |
| 41 | Supply, installation , testing and commissiong factory made LT feeder pillar box outdoor type platform mounted of size 1800 mm x1200 mm x 450 mm suitable for 415 Volts 3 phase 4 wire system 50Hz supply having aluminum bus bar 600 Amps for phases and neutral, installed on porcelain / epoxy insulator. the panel shall be dust proof, vermin proof (IP54) and applying spray paintig with two coats of synthetic enameled paint over a coat of red oxide primer on sheet and made of out of 3.15 mm thick CRCA sheet self moulded type and 50x50x6 mm angle iron frame front and rear opening with double shutter and locking arranement with 50mm lock and including grouting of panel with necessary PCC 1:2:4 type B-1 work complete all as specified.The scope of work includes provision of housing the following acceessories:-Incoming :- (i) MCCB having current rating 200 Amp. 4 pole of breaking capacity 36 KA -01 No.(ii) Volt meter 0-500 Volts,Square flush pattern,digital type -01 No.(iii) Amp meter square flush pattern 0-600 Amps digital type-01 No.(iv) Indicating lamp LED type one set in incoming phases.(v) Internal wiring with PVC insulated copper conductor multi stranded cable 1100 volts grade IS 694 marked .(vi) Alarm System for indicate the commercial power failure.Outgoing :--(i) MCCB having current rating 100 Amp, 4 pole of breaking capacity 25 KA,415 volts -02 Nos.(ii) MCCBhaving current rating 63 Amp, 4 pole, of breaking capacity 16 KA, 415 volts -02 No. |
| 42 | M&L for brick masonary plateform of size 2.00m x 2.00m x 1.10m (above GL), for installation of transformer brick masonary built in CM (1:6) above ground level 150mm thick PCC( 1:5:10) type E2 in foundation having projection of 150mm on both side of wall 300mm Brick masonary brought to course in CM (1:6) , 1.10m depth below ground level plateform shall be 1m above GL in typical drawing No CE(ALD/TD-188). Brick masonary shall be pointed with fluse pointing in CM (1:3) floor shall be 50mm thick PCC (1:2:4) type B-1 laid over 100mm thick hard core approved earth and including chain link fencing and steel gate as per relevent typical drawing complete all as specified and directed. |
| 43 | Dismentling, shifting, re-installing of existing elevated HIRL/MIRL runway/ Taxiway/ Turning pad fitting including installation of isolating transformer, crimping/ jointing of plug & receptacles, laying of secondary leads including supply of materials complete all as specified and as directed. |
| 44 | Supply and laying of DWC HDPE pipe 32mm dia ISI marked alongwith all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. directed in ground (50 cm below ground level) complete all as specified and directed. |
| 45 | Removal of primary cables with HDPE conduit and GI wire from existing location and servicable materail handed to AF authority complete all as specified. |
| 46 | Construction of Transformer housing (TH) box using cement concerete in foundations, filling and mass conceet (1:2:4) type B2 25mm graded aggregate of size 1m x1m x 025m complete all as specified and as directed. |
| 47 | M&L for Chemical Earthing by drilling a hole of 100 mm dia and 4 Mtr in depth in any kind of soil and providing a 3.0 mtr long pure copper strip of size 32mm x 6mm duly encapsuled in a medium grade Galvinized Steel pipe of size 88mm (OD) and filling the hole with advance non toxic earth enhancing backfill compound (qty not less than 30 Kgs) and water till complete soaking of Chemical- watermixture and providing a cylindrical type FRP earth pit chamber of size254mm dia at top, 330mm dia at bottom and 260mm height and 7.50 Mtr long copper strip of size 32mm x 6mm as earth lead conductor duly protected with a 65mm bore medium grade GI pipe (from terminal point to earth test point)and duly connected with the terminal point through brazing and to connect with earth test point with brass bolts, nuts and washers of suitable size and fixed on the walls by mounting the strip on FRP / DMC Bridge insulators and providing a test point terminal block made of Gun Metal or Phosphorus Bronze of size 75mm x 75mm x 25mm, duly drilled and screwed and fixed on wall on insulators including 3 Nos 8mm dia 25mm long hex head brass screw complete with removing of excavated soil to a distance not exceeding 50 Mtr and at a height not exceeding 1.5 Mtr from the starting point and testing on completionall as specified and as directed.Note : (i) The additional length of earth lead conductor beyond 7.5 Mtr (if required at site) shall be measured and paid separately under the respective item mentioned here-in-under. (ii) Earth resistance should be maximum 1 ohm. In case the same is not likely to be achieved. The contractor will go for additional depth & soil treatment so as to achieve maximum 1 ohm resistance.Without any extra cost |
| 48 | M&L for earthing comprising of copper earth plate electrode 600 mm X 600 mm X 3 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.50 m below normal ground level, connected to copper earth strip of size 20 X 3 mm by means of nut-bolts, check nuts and washers of copper all as shown on electrical plate No. 3 of MES schedule 2009, Part–I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust and common salt all around the earth plate in alternate layers minimum 150 mm (compacted thickness) in all directions with and including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover of size 450 mm X 450 mm in cement concrete 1:2:4, type B-1, duly reinforced with 8 mm dia mild steel TMT bars @ 100 mm both ways center to center with suitable lifting handle made of 10 mm dia mild steel round bar to lift the cover, earth pit of PCC 1:3:6 type C-1, GI protection pipe light grade 40 mm bore including testing on completion of job complete all as specified and directed. |
| 49 | M&L for Earthing comprising of galvanised steel earth plate electrode 600 mm X 600 mm X 3 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.50 m below normal ground level, connected to GI earth strip of size 20x3 mm by means of nut-bolts, check nuts and washers of copper all as shown on electrical plate No. 3 of MES schedule 2009, Part–I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust and common salt all around the earth plate in alternate layers minimum 150 mm (compacted thickness) in all directions with and including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover of size 450 mm X 450 mm in cement concrete 1:2:4, type B-1, duly reinforced with 8 mm dia mild steel TMT bars @ 100 mm both ways center to center with suitable lifting handle made of 10 mm dia mild steel round bar to lift the cover, earth pit of PCC 1:3:6 type C-1, GI protection pipe light grade 40 mm bore including testing on completion of job complete all as specified and directed. |