| 1 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/ loose soil complete all as specified and directed |
| 2 | Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface as in any type of soil. |
| 3 | Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, man holes, laying of cable and pipe line etc and getting out in soft/loose soil complete all as specified and as directed by Engr-in-Charge. |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5m in any kind of soil, as directed by Engineer-in charge |
| 5 | Returning filling in soft/loose soil including spreading levelling watering and wall ramming in layers n/exc 25 cm thick all as spd and directed |
| 6 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 7 | Removing excavated material beyond 50m andup to a total distance of 250m complete all as specified and directed. |
| 8 | Removing excavated material exc. 250m but n exc. 500m and depositing where directed |
| 9 | M & L Cement concrete Type B-2 1:2:4(40 mmgraded aggregate) in posts (including caps and bases)/mass concrete, surface channels and drains, complete all as specified and directed. |
| 10 | M&L for Type D-2 PCC 1:4:8 ( 40mm graded aggregate) in foundations, sub base, filling and mass concrete, complete all as specified. |
| 11 | S & F Compound girders andstanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. conforming to Fe-290 Gde-E-165 complete all as specified and directed |
| 12 | M&L for preparation ofnew steel Surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of anti corrosive Epoxy paint overtwo coats of Epoxy primer on steel surfaces complete all as specified and directed. |
| 13 | M&L cement concrete in foundation type C-2, 1:3:6 (using 40 mm graded stone aggregate) as in filling and mass concrete complete all as specified and directed. |
| 14 | M&L for formwork flat to chullah hood , chajjas, troughs and similar items including edges etc. rough finished surface complete all as specified and directed. |
| 15 | M & L RCC Type B-1 1:2:4 (20 mm graded aggregate) nominal mix as in landings, cover slabs (for man holes etc.) challah hoods,; stairways (except spiral staircases) including steps (square or spandril), string pieces, troughs, troughs for wash basins, carriages, etc., complete, any section straight or winding, but excluding landings; RCC water tanks up to 1500 litres etc complete all as specified & directed. |
| 16 | M & L TMT (CRS/CRM/HCRM) bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 17 | M & L TMT (CRS/CRM/HCRM) bars 5mm dia and over up to and including 10mm dia in stirrups, spacers and binderscomplete all as specified and directed. |
| 18 | M&L for precast cement concrete block masonry in type C1, 1:3:6 (20 mm graded aggregate) with solid blocks exc 10 cm in width and setting in cement mortar 1:6 in foundation load bearing wall and wall complete all as specified and directed. |
| 19 | M & L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified & as directed. |
| 20 | M & L for Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface all as specified and directed |
| 21 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, all as specified and directed |
| 22 | Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pilasters, buttresses, etc.; vertical or to batter, all as specified and directed |
| 23 | M & L RCC M-30 (Design mix) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete |
| 24 | M & L RCC M-30 (Design mix) as in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses |
| 25 | M&L 75mm thick PCC Type C-1, 1:3:6 (20mm graded agg) as in plinth protection finished even and smooth without using extra cement |
| 26 | M&L for 75mm thick cement concrete type D2, 1:4:8 (40 mm graded stone aggregate) as in sub base complete all as specified and directed |
| 27 | M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 28 | M&L for cement plaster 8 mm thick in cement mortar 1:4 with approved water proofing compound over backing coat of 12 mm thick in cement mortar 1:6for external faces of walls complete all as specified and directed. |
| 29 | M & L for rendering 15mm thick in two layers in CM 1:4 with approved water proofing compound on brick/block masonry or concrete surfaces finished even and smooth without using extra cement.(Note : WPC shall be measured separately under relevant items of BoQ) |
| 30 | Supply only Liquid water proofing compound complete all as specified. |
| 31 | M& L for fixing swimming pool tiles of area not exc 0.11 sqm fixedwith tile adhesive average bed thickness by giving space between two tiles with 4mm spacers all complete as per the manufacturer instructions.Note :- (i) Spacer including Epoxy joint filling shall be provided between tiles and quoted rate is inclusive of the same. |
| 32 | M & L for heavy duty outdoor vitrified tiles of size 300x300x10mm laid over and including 15mm thk screed bed in CM 1:4 set and jointed in neat cement slurry and pointed with white or coloured cement to match with tile complete all as specified and directed. |
| 33 | S&F PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to wall of size 75mm bore, including necessary clampscomplete all as specified and directed. |
| 34 | S&F 75 mm dia PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches/floorincluding necessary clamps complete all as specified and directed. |
| 35 | S&F PVC (SWR) bend with access door any radius 75mm bore complete all as specified and directed by . |
| 36 | M & L PVC (SWR) gully traps 125/100mm setting and jointed in cement solventcomplete all as specified & directed. |
| 37 | S & F pre painted cast iron 03 seater garden benches complete all as specified & directed. (Weight X Size of benches shall be as appd by GE/Engr-in-Charge). Note : Contractor should have enquired this aspect (Weight X Size) before quoting the rates and no claim whatsoever may be admissible on this account. |
| 38 | M&L for Glazed ceramic tiles in vertical surface, 7 to 8mm thick, area of each tile exe 0.10 Sqm but n exc 0.20Sqm set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering in CM 1:4 complete all as specified and directed. |
| 39 | M&L Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed 15mm thick in CM 1:6 complete all as specified |
| 40 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed |
| 41 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete. |
| 42 | M&L for PCC (1:3:6) type C-1 (Using 20mm graded stone aggregate) as in cills, copings, bed blocks for hold fasts and the like incl necessary form work, complete all as specified and directed. |
| 43 | M&L for Providing cement concrete Type B1 1:2:4 (using 20mm aggregates) inin lintels up to 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, all as specified and directed.(Rate incl of use of formwork (straight or curved).) |
| 44 | M&L Rendering 10mm thick in CM 1:6 on brick or concrete surfaces of wall complete all as specified. |
| 45 | S&F Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) , bars including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165 |
| 46 | M&L for mild steel screw bolts 5 to 10 dia of neck in mm(machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long. |
| 47 | S & F PVC coated chain link fencing of any size andGauge as approved by GE confirming to IS 2721 including line wires fitted to to any type of standards, rails, straining bolts, fencing posts etc. including provision of binding wire or using suits bol |
| 48 | S & F round bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with andincluding mild steel wire (annealed) not less than 0.9mm dia all as specified. |
| 49 | M&L Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work for portions framed and hung as gates for ornamental and intricate design, including pintle hinges, stops, hand-made sliding bolts, etc. conforming to Fe 290 Gde E-165 complete all as specified and directed. |
| 50 | M&L for preparation of new plastered External surfaces for preparation of surface and applying two coats of weather proof antifungal paint (Asian- apex Ultima Protek or equivalent) over a coat of suitable primer incl1.5mm thick wall care putty, complete all as specified and as directed by the Engineer-In-Charge.Note:- Application of paint, primer and wall care putty shall be as per manufacturer\"s instruction. |
| 51 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etccomplete all as specified and as directed. |
| 52 | Dismantling aluminium works of any description as directed |
| 53 | Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed by Engr-in-Charge. |
| 54 | Taking down chowkatsor framesnot exceeding1.5 Sqmeachbut with shutters (without taking off shutters from the frames) all as specified. |
| 55 | Demolition of Brickwork or stone/boulder masonry, built in cement mortar. |
| 56 | Taking down cementplaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water any description, etc. |
| 57 | M & L for preparation new wall surfaces of wall and applying 1.5mm- 3 mm thick wall care putty on new wall surfaces, Priming plastered and other surfaces with alkali resistant priming paint and applying two coats of oil bound distemper on walls, including applying additional coats wherever required to achieve even shade and colourall as specified and directed. |
| 58 | M & L for complete removal of existing treatment, preparatory to distempering& applying two coats of distemper oil emulsion white or tinted over a coat of alkali resistant primer on ceiling all as specified and directed. |
| 59 | M & L for preparation old wall surfaces incl Washing, rubbing down and stopping of distempered and painted surfaces and Priming plastered and applying one coats of distemper oil emulsion white or tinted washable incl filling of nail holes/disturbed surfaces n.exc 0.15sqm by cementitious wall care putty all as specified and directed by Engineer in charge |
| 60 | M&L Forming jambs, etc. to openings (to foregoing item) in cement mortar 1:4 , including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete as specified and directed by Engineer in charge |
| 61 | Making good under cills or over arches, lintels and bressummers including all pinning when necessary in cement mortar 1:4, as specified and directed by Engineer in charge |
| 62 | S&F powder coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified. |
| 63 | S&F powder coated aluminium door , partitioning shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc. complete all as specified. |
| 64 | S&F Aluminium powder coated three track sliding windows with three sliding shutters with glass panes and stainless steel jalli) including suitable beading channel gasket, rollers Maruthi lock with handles etc complete with following specification:-Frame :- 92.36mmx29.70mmx1.50mmShutter stiles, top & bottom :- 39mmx20mmx1.5mmPanel :- 5.00mm thicktinted sheet glass of selected quality exc 0.50Sqm each pane fixed to aluminium frame with beading, rubber gasket. Mosquito proof jali:- Stainless steel jali 0.45mm nominal dia of wire and average width of aperture 1.40mm fixed type with appropriate sizepowder coated aluminium section on external faces of window.Note: The quoted rate shall be inclusive of the rates of glass and SS Jalli |
| 65 | S&F Aluminium powder coated three track sliding windows with three sliding shutters with glass panes and stainless steel jalli) including suitable beading channel gasket, rollers Maruthi lock with handles etc complete with following specification:-Frame :- 92.36mmx29.70mmx1.50mmShutter stiles, top & bottom :- 39mmx20mmx1.5mmPanel :- 5.00mm thickfrosted sheet glass of selected quality exc 0.50Sqm each pane fixed to aluminium frame with beading, rubber gasket. Mosquito proof jali:- Stainless steel jali 0.45mm nominal dia of wire and average width of aperture 1.40mm fixed type with appropriate sizepowder coated aluminium section on external faces of window.Note: Rate quoted is inclusive of glass and SS Jali |
| 66 | S&F Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified. complete all as specified. |
| 67 | S & F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in- charge. |
| 68 | M&L 4mm thick sheet glass plain frosted type ordinary quality and glazing with aluminium beading nexc 0.5 sqm etc complete all as specified and directed |
| 69 | M&L 4mm thick frosted sheet glass type ordinary quality and glazing with aluminium beading nexc 0.5 sqm etc complete all as specified and directed |
| 70 | S&F 4.0mm thick Aluminium composite panel of matching shade/colour to framework ,complete all as specified and as directed by the Engineer in Charge |
| 71 | S&F 6.0mm thick Aluminium composite panel of matching shade/colour to framework ,complete all as specified and as directed by the Engineer in Charge |
| 72 | M & L for Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), in all kinds of soils including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated earth as directed, within a lead of 50 m. |
| 73 | S&F 150mm long aluminium anodized barrel tower bolt of extruded sectioncomplete all as specified. |
| 74 | S & F Floor door stopper(140mm overall length of cover plate) of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, complete all as specified and as directed. |
| 75 | S & F aluminium (extruded section) body Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60 kg and fixed, complete all as specified and as directed. |
| 76 | S & F aluminium Mortice lock 2-lever, vertical type, size 75mm, complete all as specified and as directed. |
| 77 | Dismantling of floor hearth or wall tiles including cement mortar bedding (but not backing) and disposing the rubbish off the premises outside MD land complete all as specified and directed |
| 78 | M&L for 25mm thick PCC (1:2:4) type B-0 (using 12.50mm graded crushed stone aggregate) as in sub base of floor complete all as specified and directed. |
| 79 | M&L Vitrified coloured tiles 8-10mm thick any light Shade (square/rectangular) area of each tiles exc 0.42 Sqm but not exc1Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed of cement mortar 1:6 laying floor finishes, complete all as specified and directed. |
| 80 | S&F 18-20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) over & incl 15mm thick screed in CM 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. |
| 81 | Rounding to edges of stone slabs one edge, such as in window cills, platforms and other similar situations. |
| 82 | Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 16 Sqmm 4 core in trenches/ under road/ onwalls all as per site requirement as directed. |
| 83 | S&F 7M GI Octagonal pole single section withy bottom dia 135mm, top dia 70 mm having sheet thickness 3mm. The door height cut out should not be more than 500 mm with door elevation 500 mm. The size of the reinforced rod should be 30x4mm. Size of the base plate should be 220SQ with thickness of base plate 16mm. PCD for the holes should be 225 with foundation bolt dia M20, length of the foundation bolt 700mm with four foundation bolts. The arm should be 1 M length single arm with 15-degree arm bracket. The pole should have in build door mounting 500mm above from ground level including PCC foundation, J Bolt, nuts and washers as per the drawing of manufacturer complete all as specified and directed. |
| 84 | S&F New generation energy saving and environmental friendly long life LED street light 100 Watt made up of, pressure die cast aluminium housing, with high efficiency LEDs as lighting source and street optics lens and glass diffuser for uniform light distribution with IP-66 protection all as specified and as directed by Eng-in-Charge. |
| 85 | S&F Street light control panel wall/ pole/ PCC platform mounted single phase 6 KW load with 24 hour digital timer, contactor rating 32A, TP, MCB rating 40 Amps SPN including sheet metal enclosure with class H insulation & water resistant, incl internal wiring complete with bypass arrangements and necessary PCC foundation (as manufacturers recommendation and design). Make : Havells Cat Part No. IHXSS01060/ Indoasian/ L&T |
| 86 | M&L for 3X single core copper cable of size 1.5 Sqmm (Red, Black and Green) from junction box of the pole to light fitting and connecting to the electrical system all as specified and directed. |
| 87 | Supply and laying in trenches/ under road/ onwallsor passing through cable duct, 25Sqmm 3.5 Core XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy duty) 1100V grade with aluminium conductor including necessary lugs and gland complete all as specified and as directed |
| 88 | M & Lfor dry river sand as sand cushioning for protection of UG cable including punning of sand in layers complete all as specified and directed. |
| 89 | Supplying and laying Brick well burnt class \"B\" as in cover (cable protection) to UG cable, laid dry, flat over the cable laid across the length of the cable and abutting each other with gap between adjacent brick not exc 10mm complete all as specified and directed. |
| 90 | Supply and fixing GI pipe light grade of size 40mm diafor encasingGI strip for protection in trench or in wall complete all as specified and directed. |
| 91 | Cutting of existing hardstanding/concrete/metal/bituminous road/walk way or any other description of any type by using crow bar chisel/any other possible means ofn exc 45CM in width and n exc 20CM in depth including making good the surface by matching with PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate incl disposal of surplus material to a distance n exc 50M, complete all as specified and directed by Engineer-in-Charge. |
| 92 | Supply and fixing of on wall/ concealed on wall, 25mm dia High pressure CPVC pipes SDR-13.5 & Plain CPVC SDR 11 fittings including all necessary fittings, solvents, complete all as specified and directed. |
| 93 | Supply and fixing on wall/ concealed on wall, 20mm dia. High pressure CPVC pipes SDR-13.5 & Plain CPVC SDR 11 fittings including all necessary fittings, solvents, complete all as specified and directed. |
| 94 | Supply and fixing of Chromium Plated cast copper alloy Kitchen Sink Cock, quarter turn, wall mounted with swivel spout not less than 150 mm and wall flange complete all as specified and as directed. |
| 95 | Supply and fixing 15mm size Chromium Plated fancy type Bib Taps, quarter turn with flange and aerator, short body, cast copper alloy with crutch or butterfly handle, screwed for GI/ CPVC pipe, complete all as specified and as directed by the Engineer in Charge. |
| 96 | S&F Rotational moulded polyethylene water storage tanks 3 layered white (cylindrical vertical with closed top) hoisted & fixed in position of capacity 1000 litres, complete all as specified and directed. |
| 97 | S&F 20mm dia CPVC Ball Valve suitable for CPVC pipe including necessary fittings, complete all as specified and directed. |
| 98 | S&F 25mm dia CPVC Ball Valve suitable for CPVC pipe including necessary fittings, complete all as specified and directed. |
| 99 | Cutting / inserting on exiting any type of pipe and size with insert new Tee for new branch connection of requisite size as directed, complete all as specified and directed |
| 100 | Material and labour for point wiring for one light/fan point with 1.5 sqmm PVC insulated (FRLSH) unsheathed copper conductor multistranded 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FRLSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity conductor including connected to common earth dolly drawn through and including rigid PVC conduit medium grade ISI marked concealed of suitable size with all accessories and sunken box of 1.6 mm thick and 60 mm depth pressed steel box factory made for mounting of switch, socket and fan regulator with modular frames covers including chase cutting and making good to the disturbed surface and matching to the existing finishes specifications complete all as specified and as directed by the Engr-in-Charge. |
| 101 | All as per item No. 97 here in before but for one 5 pin 5 Amp socket outlet point on independent board complete all as specified and as directed by the Engr-in-Charge. |
| 102 | All as per item No. 97 here in before but for one 5 pin 5 Amp socket outlet point on same board complete all as specified and as directed by the Engr-in-Charge. |
| 103 | All as per item No. 97 here in before but using with 2.5 sqmm copper conductor cables multistranded (FRLSH) PVC insulated, unsheathed cable and including 2.5 Sqmm copper conductor cable multistranded (FRLSH) PVC insulated and unsheathed cable as earth continuity wire and connecting to common earth dolly for one 6 pin 15 Amp socket outlet point on independent board complete all as specified and as directed by the Engr-in-Charge. |
| 104 | All as per item No. 97 here-in-before but one 3 pin socket outlet for 15Amps socket point controlled by one single pole switch one way and wiring with 4.0 Sqmm PVC insulated, stranded, unsheathed copper conductor on independent board with continuous earth wire of size 4.0 Sqmm green colours PVC insulated, unsheathed, stranded copper conductor cable. |
| 105 | Supply and fix ceiling rose surface Bakelite 65 x 50 mm 3 terminals 240 volt 50 Hz complete all as specified and as directed by the Engr-in-Charge. |
| 106 | S&F modular type sockets 6 Amp-2/3 pin combined 2 module complete all as specified and as directed by the Engr-in-Charge. |
| 107 | S&F switch modular type single pole, 6 Amps, one module complete all as specified and as directed by the Engr-in-Charge. |
| 108 | S&F modular sockets 6 Amp/16 Amps, 2/3 pin combined 2 module complete all as specified and as directed by the Engr-in-Charge. |
| 109 | S&F switch modular type 1 module, 16 Amps, one way complete all as specified and as directed by the Engr-in-Charge. |
| 110 | Supply and fixing inLED lights fitting 1x 20 W, 220V, AC decorative box type,125 lumen/wattwith driver, holderand high quality materials and design extruded aluminium housing enhances safety, high quality PC diffuser reliable and robust housing structure including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed by the Engr-in-Charge. |
| 111 | M/L sub main wiring with 2 single core 4 Sqmm PVC insulated unsheathed multistranded copper conductor cable 1100 volt grade drawn through and including PVC rigid conduit concealed wiring including necessary PVC conduit specials including chases cutting complete except beam and RCC roof and one run of 4 Sqmm PVC insulated unsheathed single core 1100 volts grade multistranded copper conductor cable as earth continuity conductor and connecting with suitable size thimble complete all as specified and as directed by Engineer-in-Charge. Note: two run of 4 sqmm size PVC cable , one run of 4 Sqmm size PVC cableas earth wire and one run of PVC conduit shall be measured as one unit length |
| 112 | Supply and fix in Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20Amp,240 volts ,50 Hzincluding taking down old one complete all as specified and as directed by the Engr-in-Charge. Make -Legrand ,L&T,Schneider . |
| 113 | S&F Sheet metal enclosure for MCB DB, SPN, 8 ways, double door, with 200 amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified and as directed by the Engr-in-Charge. |
| 114 | Supply and fixing amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB)40- 63 ampsof twopoles and current carrying capacity in the MCB SPN complete with connection testing and commissioning complete all as specified and as directed by the Engr-in-Charge. |
| 115 | Supply and fixing 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and as directed by the Engr-in-Charge. |
| 116 | Amount of Schedule of credit of for Rs 5,900.00 shall be deducted from quoted amount. |