Tender For Roof And Electric Repair Work At Ece Department Ctae, Udaipur Roof And Electric Repair Work At Ece Department Ctae, Udaipur. - 1 Dismantling Old Plaster Or Skirting, Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of, udaipur-Rajasthan

Maharana Pratap University Of Agriculture And Technology has published Tender For Roof And Electric Repair Work At Ece Department Ctae, Udaipur Roof And Electric Repair Work At Ece Department Ctae, Udaipur. - 1 Dismantling Old Plaster Or Skirting, Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of. Submission Date for this Tender is 04-04-2025. Septic Tank Tenders in udaipur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

48426652
Tender For Roof And Electric Repair Work At Ece Department Ctae, Udaipur Roof And Electric Repair Work At Ece Department Ctae, Udaipur. - 1 Dismantling Old Plaster Or Skirting, Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of
Open Tender
NCB
Rajasthan
Udaipur
04-04-2025

Tender Details

Tender For Roof And Electric Repair Work At Ece Department Ctae, Udaipur Roof And Electric Repair Work At Ece Department Ctae, Udaipur. - 1 Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. 2 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer-in-charge.1: 3: 6 or richer mix. 3 Plaster on new surface on walls in cement sand mortar 1:6 including rackingofjointsetc. complete fine finish :25 mm thick. 4 Grading roof for water proofing treatment withwater proffing compound : Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 5 Providing & laying broken glazed titles on roof ( broken glazed tilesnot less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg ofVG-40 (30/40 )grade and 0.30 Kg/Sqm. OfVG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. 6 Finishing with neat cement (punning). 7 Repair to damaged RCC slabs, beams and columns etc for strengthening with cement mortar 1 : 2 in following steps :-Choping losse and cracked concrete to required depth, cleaning the exposed surface of steel and concrete with wire brush and sand papering , cleaning of concrete surface with water as necessary and getting dried. (ii)Applying Epoxy primer on the exposed steel bars.(iii)Applying Epoxy hardener and resin mix (as per manufectureds specification) on concrete and steel bars with brush.(iv)Speading dry cement mortar 1 : 2 mix over epoxy treated wet surface and allow it to dry for one day.(v)Plastering the surface with cement sand mortar 1 : 3 upto depth of 30mm complete. (vi) Cure the plastered surface for 15 days, All work including scaffolding etc. complete in all respect. 8 Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1 cement : 4 coarse sand) 9 Labour charges for repair to door / window without using any material such as applying randha (finishing) tightening of bolts & screw etc. 10 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 11 Stone slab roofing on ground floor with fine grained stone slab from approved quarry including filling of joints of parapet and slab on both sides in cement sand mortar 1:4,with ceiling pointing in cement sand mortar 1 : 3 complete as per specification and instruction of Engineer In Charge 12 P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant.: 110 mm dia 13 P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant:110mm dia 14 (a) Bend 87.5 dg 15 (b) Pipe Clip 16 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make: 110 mm dia 17 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make: 110mm dia 18 (a) Bend 87.5 Dg., 19 Bend 45 Dg. 110mm dia 20 Door Bend 87.5 Dg. 110mm dia 21 Coupler 110mm dia 22 Single Tee 110mm dia 23 Nahni Trap without Jali 4” 24 P & F Grating of approved quality/make: Stainless Steel Sheet size 125mm dia. 25 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall) 26 20mm nominal size 27 25 mm nominal size 28 Making connection of G.I. distribution branch with G.I. main including all fitting.Upto 25mm dia 29 P & F 15 mm. Dia Connection Pipe of approved quality/make :PVC pipe withC.P. Brass nuts upto length, 600mm 30 Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth completeOld Plastered Surface (two or more coats) 31 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. 32 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: Old work (One or more coats ) 33 Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm ). 34 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : One or more coats on old work. 35 P & F PVC Storage Tank ISI Marked (IS : 12701) indicating theBIS license No),of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design: 1000 litres capacity. 36 P & F Ball Cock (IS :1703 Mark) with Rod& P.V.C. Ball complete :Brass wt.Not less than 400 gm, 20mm. 37 P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :Gun-metal 25mm nominal bore. 38 Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m,10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr.Inside size 450 X 450 mm depth upto 0.5 MCement cover with frame. 39 Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 gradeC.C floor &RCC slab covering with M15 grade c.c. floor,50 mm thick stone slab partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos stone foot rests of approved design ,two No. 450 mm dia each Ferro cementcover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:-Size 400 x140x150 cm.(for 50 users)with 115 mm thick RCC (M-20) slab with Tor steel reinforcement 10mm ϕ @15 cm c/c bothways including shuttering complete in all respect. 40 Emptying of Septic tank ,Soakage well etc. by disposing or sludge upto 5 Km. lead & taking out sewage including cleaning of site. 41 Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.:Size 300 Cm. dia outside & 300 Cm. depth . 42 Wiring of light point/ fan point/ exhaust fan point/ call bell point with1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathedflexiblecopperearthconductor1.1kVgrade(IS:694)on surface ISI marked ( IS:14927 P - II ) virgin materialUPVC trunking & its accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal/ Surface Moulded virgin materialUPVCModular Box,10AModularswitch,Modularface platewithgridplate,3pin ceilingrose/holder/3wayConnector, screws, makingconnections, testing etc. as required. For specification of copper conductor, Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 43 (a) Short point (up to 3 mtr.) 44 (b) Medium point (up to 6 mtr.) 45 (c) Long point(up to 10 mtr.) 46 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FRPVCinsulatedunsheathedflexiblecopperconductor1.1kVgrade and1.5sq.mmnominalsizeFRPVCinsulatedunsheathedflexible copper earth conductor 1.1 kV grade(IS:694) on surfaceISI marked ( IS:14927 P - II ) virgin materialUPVC Trunking & its accessories, Hot Dipped GalvanizedModular box of 1.2 mm thickwith earth terminal/ SurfaceMouldedvirginmaterial UPVCModularBox, modular10A switch, 3/5 pin6 Amodular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR.(a)On board 47 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductorasperPWDspecificationforelectricalWorkswithISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should bemadefrom 99.90%puritycopper,class5strandinginacc.to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization,insulationPVCtypeA/C/D,flameretardantasperIS 10810-53,betteramperageratingasperIS:3961part5, inexisting surfaceorrecessedPVC/MS conduit/casingcapping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required.OEMMusthaveitsowninhouseNABLlabsetupforall testingfacilitiesforwires.Foradditionaltechnicalparametersof product / work refer Annexure A attached with this BSR. 48 (a)2 x 1.5 sq.mm 49 (b) 2 x 2.5 sq. mm. + 1x1.5sqmm 50 (c) 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 51 (d) 4 x 6.0 sq.mm 52 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of loadand siterequirement)4KVimpulsewithstandvoltage,ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947- 2, low watt losses, trip free mechanisum , energy limiting ofclass 3 asperIEC, minimumphaseterminationcapacityof35sq.mm., conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000upto20Aratingand10,000upto63A,5000for80A& above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR. 53 (a) Single pole MCB (With B/C curve tripping Characteristics) 100 A rating 54 Providing&Fixingof240/415Visolator ISImarked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KVimpulse withstandvoltage,truecontact indication, Redcolourdolly/levershallhavesinglemouldcoveringoverall polesforoperation,twopositiondinrailmounting, minimum phase termination capacity of 35sq.mm.IP 20contact protection andfittedinexistingdistributionboard/sheet includingmaking connections, testing etc. as required. OEM shall have submitNABL/ CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR. 55 (a)Four pole Isolator 80 A/ 100 A rating 56 Providing & Fixing of Recessed/surface mounting heavy duty horizontaltypeDoubleDoor(Metal/Glazed)Distributionboard with Metal end box made out from Galvanized steel / CRCA sheet notlessthen1.2mmthick conformingtoIS-8623-1&3/ IEC 61439- 1 & 3, powder painted completewith reversibledoor (for double door DB only )100 amp.insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnectingwireset ofsuitableratinganddinbar,masking sheet,making internal DBterminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated labtypetestreports &AllasperpreapprovedbyEngineerin charge. For additional technical parameters of product / work refer Annexure A attached with this BSR. 57 (a) Metal door (Three phase) IK-09 and IP-43with Metal end box 6 Way 58 Providing&Fixingofmodulartype120WStepFanregulatordulyISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. Foradditionaltechnicalparametersofproduct/workrefer Annexure A attached with this BSR. 5 step fan regulator 2 Module 360 dgree rotating 59 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular boxof1.2mmthickwithearthingterminal/connectoronsurfaceorin recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16amp.socketoutlet(IS:1293)makingconnection,testing,etc.as required.Forspecificationof WiringaccessoriesreferChapter E-07 related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 60 Providing&LayingP.V.C./XLPEinsulated&P.V.C.sheathedUn-Arrmoured Aluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) includingtesting etc.asrequiredoffollowingsize.OEMmusthaveitsowninhouseNABL accrediatedLaboratoryfortestingprocedureasperIS:10810.Foradditional technical parameters of product / work refer Annexure A attached with this BSR. (a) 50.0 Sq. mm ,3.5 core 61 AddExtrainitemno.11.1to11.4forLayingandfixingofonenumberPVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.. Above 35 sq. mm and upto 95 sq. mm fixed with 40 mm x 3 mm thick suitable lengthredoxideandenamelpaintedMSclampandbase,pvcrawlplugand screws of sufficient size with spacing 0.6 Mtr. Between Clamps. 62 PlateEarthing asperIS:3043withHotdippedG.I.Earthplateofsize 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. G.I. B class watering Pipe ,including all accessories likenut,bolts,reducer,nipple,wiremeshedfunnel,andHeavyduty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodyingthepipe completewithalternatelayerssaltandcoke/ charcoal,testingofearthresistanceforvalueof5ohmsorless as required & must record by engineer in charge during site visit and ensure toenterinmeasurmentbook.AllasperpreapprovedbyEngineerin charge. Foradditionaltechnicalparametersofproducts/work ,refer Annexure A attached with this BSR . 63 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .8 SWG G.I. ( Hot Dipped) Wire 64 Providing&Fixingof BEE Starratedcopperwoundeddoubleball bearingcapacitorstart,aluminiumbody&Metallic bladeceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e.ISImarking)withdownrodupto80cmwithsecondarysupport safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All asperpreapprovedbyEngineerincharge. Foradditionaltechnical parameters of products/ work, refer Annexure A attached with this BSR . 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) 65 P & F in position frame made out of M.S. angle (riveted or welded) finishedwithtwocoatsofredoxideandtwocoatsenamelpaint including cutting, welding, holes etc.of following sizes as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 25mm x 25mm x 3mm 66 Providing & Fixing of Recessed/surface mounting heavy duty EnclosuremadeoutfromGalvanizedsteel/CRCAsheetnotless then 1.2 mm thickconforming to IS-8623-1 & 3 /IEC 61439- 1 & 3. powder painted complete with din railmaking internal DB terminationswithcopperlugs, detachableglandplate,including makingconnections,testingetc.asrequired.Foradditional technical parameters of product / work refer Annexure A attached with this BSR Suitable for Two / Three / Four module for MCB 67 Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made fromPowdercoatedExtrudedaluminium housingwithinbuiltdriver ,Systemlumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with,70%ofintialLumenmaintanedtilllifeends ,CCT3000°K/4000°K /5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate/ReportfromOEMshallbesubmitted. Allasperpreapprovedby Engineerincharge. Foradditionaltechnicalparametersofproducts/work ,refer Annexure A attached with this BSR1170mm(+/-10%) LED batten with min. lumen output 2200 lm 68 Labour charges for dismantling of surface PVC/ Steel conduit including wiring in conduit,conduit fittings and depositing the same with listing of material in store. 69 Labour charges for dismantling of surface/ recessed switch board of any size and depositing the same with listing of material in store.

Key Value

Document Fees
INR 590 /-
EMD
INR 27600.0 /-
Tender Value
INR 13.80 Lakhs /-