Supply, Installation, Test Run And Commissioning Of Electrical Substation Including Allied Electrical Works At Kalyani Duck Breeding Farm, Slf Campus, Kalyani, Nadia-41235 Under West Bengal Livestock Development Corpn.Ltd., Lb-2, Sector-Iii, Kolkata. , Electrical Work / Installation , Transportation, Carriage, Loading & Unloading Of The Vcb& Apfc Panel To The Site. , Transportation, Carriage, Loading & Unloading Of Thetransformer To The Site. , Installation, Testing, Commissioning Of 500 Kva, 11/0 415 V Dry Type Indoor Distribution Transformer, Including Carriage With Within A Lead Of 30 M By Placing In Position ,Assembling Living Up Leveling And Fixing On The Floor, And Checking All Component ,Correctly Set According To Requirement And Including S And F Base Frame As Requirement , Totally Repairing Of Enclosed Single Panel Metal Clad 630 Ampere Indoor Type Ht Vacuum Circuit Breakersuitable For 11 Kv,Three Phase 50 Hz Ac Main Power Supply Including Carriage, Positioning, Assembling, Repairing And Supply Of Power Bank, Internal Wirrings, Spouts-3 Nos, Ct Coil- 3 Nos,Relay Correct Set According To Requirement. , Installation Of 630 A Vcb Complete With All Necessary Connections Including Carriage Within A Lead Of 30 Mtrs By Placing In Position, Assembling Living Up, Leveling And Fixing On The Floor, Fitting And Checking All Component, Correctly Set According To Requirement And Including S And F Base Frame As Requirement , Supply And Delivery Of Cubical Type Lt Distribution Panel Board Of Appropriate Size Base Mounted Compartmentalized With Maple Arrangement Having Rigid And Self Supporting Structure Fabricated From 3 Mm Thick Crca Sheet Steel With M/S Angle Frame The Panel Board Consisting Of The Following Switches A) Incoming Arrangement Supply And Fixing In A Separate Chamber Microprocessor Based 50Hz 415V 800 Ampere Breaking Capacity 65 Ka Electrical Drawout Type Acb With Ipr To 4 Pole -1 Nos B) Bus Section 500 Volt 1000 Ampere Aluminium Bus Barwith Vertical Section Of Appropriate Size For Neutral And Phases. , A Bus Bar Shall Be Fixed With Frp Chair And The Entire Bars Are Insulated With Pvc Heat Sinkable Cable Sleeve Of Suitable Size And Colour As Par Direction Of E.I.C. B)Switch This Connector Fuse (Panel Mounting Cubical Type) Confirm To Is: 13947 In Pen Execution 3 Pole And Neutral Ac 23 Ampere 50 Hertz 415 V 200 A - 3 Nos 400 Ampere Din Type Hbc Fuse Link And Spreader Links -2 Nos C) Switch Disconnect Or Fuse (Panel Mounting Cubical Type) Confrom To Is:13947 In Pen Execution Three Pole And Neutral Ac 23 Ampere 50 Hertz 415 Volt 160 Ampere- 3 Nos 160 Ampere Din Type Hbcfuse Link-2 Nos , D) Switch Disconnect Of Use (Panel Mounting Cubical Type) Confrom To Is: 13947 In Pen Execution 3 Pole And Neutral Ac 23 Ampere 50 Hertz 416 Volt 63 Ampere With 3 Numbers 63 Amperedin Type Hbc Fuse Link- 2 Nosmetering Panela)S And Fixing 0-500 Volt Voltmeter Of Size 96 Metres Millimetre Square (Square Type) Ae Make -1 No B) S And Fixing 0-500 Ammeter Of Size 96 Mm Square Type Ar Make -1 No C) S And F Rotary Type Voltmeter Selector Switch Off 10 Ampere Kaycee Make -1 No D) S&F Rotary Type Ampere Metre Selectorswitch Of 10 Ampere Kaycee Make -1 No E) S And F Current Transformer Of Size 500 / 5A Kappa Make -3 No F) S And F 20 Ampere Bakelite Fuses Base And Bridge With 4 Ampere Hrc Fuse Link Ge Make -3 Nosg) S&F Danger Board -1 No Inter Connection: All Interconnection Of Switches And Bus Bar Shall Be Made With Suitable Size Copper Bar To Be Kept For Cable Connection For Main Switchesand Change Over And The End Of All Connections Ofmetering. , Outgoing 400A 4 Pole Mccb-1 No.250A 4 Pole Mccb- 2 Nos.160A 4 Pole Mccb- 2 Nos.100A 4 Pole Mccb- 1 No. 63A 4 Pole Mcb - 2 Nos. , Supply Of 11 Kv Grade 3.5 Core 240 Sqmm Pvc Insulated Armoured Xlpe (E) Htcable With Aluminium Conductor. (Mescab/Gloster Make) , Laying Of 11 Kv Grade 3.5 Core 240 Sqmm Pvc Insulated Armoured Xlpe (E) Htcable As Required. , Finishing The End Of Following Xlpe/Pvc Armoured Cables By Crimping Method Incl. Supplying And Fixing Solderless Socket (Dowels Make), Tapes, Anticorrosive Paste & Jointing Materials : , 3.5 Core 185 Sq.Mm. Page-F5, Item-8(B)(Xxi) , Supplying And Fixing Compression Type Gland Complete With Brass Gland, Brass Ring & Rubber Ring For Dust & Moisture-Proof Entry Of Xlpe/Pvc Armoured Cables As Below : , 3.5 Core 185 Sq.Mm. , Installation Of Apfc Panel Complete With All Necessary Connections Including Carriage Within A Lead Of 30 Mtrs By Placing In Position, Assembling Living Up, Leveling And Fixing On The Floor, Fitting And Checking All Component, Correctly Set According To Requirement And Including S And F Base Frame As Requirement , Supply And Fitting And Fixing Of 12 Kv (5 Ka) Lighting Arrester , Making , Testing , Arrangement And Submitting The Test Report For High Voltage Testing Of Specified Voltage Including Checking And Testing Of All Hd / Lt Equipment By Authorised Firm Of Directorate Of Electricity , S&F 9 Litre Capacity Round Fire Bucket Including S&F Ms Hook And Duly Filled Up By Sand As Directed By Eic , 02 Kg Capacity With Isi Marked Co2 Type Fire Extinguisher Squeeze Grip Type Conforming To Is:15683:2006 Made From Seamless Cylinder Conforming To Is:7285 Duly Approved By Chief Controller Of Explosive,Nagpur, Fitted With Isi Marked Controller Of Explosive,Nagpur, Fittet With Isi Marked Controlled Valve Conforming To Is:3224, Discharge Adopter And Horn Complete With Initial Gas Charged With Carrying Handle And Wall Mounting Bracket Suitable For Operating Between (-)30ºc To (+)55ºc. Fire Rating -8B , S&F Best Quality First Aid Box (Aluminium Body) As Per Pwd Specification Completed With All The Item As Required By Rules Of Substation On Ms Bracket On Wall Including Mending Good The Damage To Original Finish , S&F Shock Treatment Chart Pasted On Hard Board On Wall With Screw As Required , S&F 11 Kv Rubber Hand Gloves , Supply And Delivery 6 X3 X0.5 Rubber Mat For 11 Kv Substation .Best Quality And Isi Approved , S& F E.I. Danger Board Of Size 20Cm X 30Cm On Wall , Arrangement Of Different Types Of Routine Test And Commissioning Of 1 Transformer , 1 Lt Vcb And 1 Lt Panel As Per Is2026 And Commissioning The Installation After Obtaining The Approval From The Director Of Electricity As Direction Ofeic , Excavation Of Soil For Installation Of Earth Electrode And Filling & Ramming. (A) For Soft Soil. , Earthing With 80 Mm Dia Gi Pipe (Tata-Medium)X 3.0 Mts. Long And 1 No. 65 Mm X 8 Mm Galvanized (Hot Dip) Steel Strip (4 Mts. Long), 20 Mm Dia X 125 Mm Long Galvanized Bolt, Double Nuts, Double Washers Including Finishing Both Ends By Making Holes Etc. And S & F 80 Mm Dia Gi Pipe (Isi-Medium) Protection (3 Mts. Long) To Be Filled With Bitumen Partly Under The Ground Level And Partly Above Ground Level To An Average Depth Of 3.65 Mts. , Earthing With 50 Mm Dia Gi Pipe 3.64 Mm Thick X 3.04 Mts. Long And 1 X 4 Swg Gi (Hot Dip) Wire (4 Mts. Long), 13 Mm Dia X 80 Mm Long Gi Bolts, Double Nuts, Double Washers Incl. S & F 15 Mm Dia Gi Pipe Protection (1 Mts. Long) To Be Filled With Bitumen Partly Under The Ground Level And Partly Above Ground Level Driven To An Average Depth Of 3.65 Mts. Below The Ground Level As Below: Tata Medium , Extra For Providing Masonery Enclosure On The Top Of The Earth Electrode Of Overall Size 86.36 Cm X 86.36 Cm X 46 Cm Deep (Below Ground Level) Complete With Cemented Brick Work(1:6) Of 25 Cm Width Duly Plastered With Cement Morter (Inside) Ci Hinged Inspection Cover Of Size 36.56 Cm X 35.56 Cm With Locking Arrangement, Gi Reducer Including Drilling Of 46 Nos. 12 Mm Dia Holes On The Gi Pipe. , Extra For Treatment Of Soil By Using Salt & Charcoal Or Coke For Plate Electrode. , Supplying & Fixing Earth Busbar Of Galvanized (Hot Dip) Ms Flat 65 Mm X 8 Mm On Wall Having Clearance Of 6 Mm From Wall Including Providing Drilled Holes On The Busbar Complete With Gi Bolts, Nuts, Washers, Spacing Insulators Etc. As Required. , Supplying & Fixing Earth Busbar Of Galvanized (Hot Dip) Ms Flat 50 Mm X 6 Mm On Wall Having Clearance Of 6 Mm From Wall Including Providing Drilled Holes On The Busbar Complete With Gi Bolts, Nuts, Washers, Spacing Insulators Etc. As Required. Page-G-2, Item-4 (C) , Supplying & Fixing Of High Density H.T. Earth Bar Insulator Sleeves For Line Protection. , L.T. Portion Electrical Work / Installation , Supply Of 2 Core 10 Sqmm Pvc Insulated 1100 Volt Al. Armoured Xlpe Cable. Reputed Make. , Laying Of Cable Upto 2 Core 25 Sqmm On Wall/Surface Incl. S & F Ms Saddles With Earthing Attachment In 10 Swg Gi (Hot Dip) Wire, Making Holes Etc. As Necy. Mending Good Damages And Painting. , Supplying And Fixing Compression Type Gland Complete With Brass Gland, Brass Ring & Rubber Ring For Dust & Moisture-Proof Entry Of Xlpe/Pvc Armoured Cables As Below : , For 2 Core X 10 Sq. Mm. , Finishing The End Of Following Xlpe/Pvc Armoured Cables By Crimping Method Incl. Supplying And Fixing Solderless Socket (Dowels Make), Tapes, Anticorrosive Paste & Jointing Materials : , For 2 Core X 10 Sq. Mm. , Supplying And Fixing Double-Door Spn Mcb Distribution Board With Ip-42/43 Protection, Concealed In Wall After Cutting The Wall & Mending Good The Damages To Original Finish Incl. Inter Connection With Suitable Size Of Copper Wire And Neutral Link & Provision For Earthing Attachment. L&T Make. 2+10 Way. , Supplying And Fixing 240/415 V Mcb Of Breaking Capacity 10Ka & C Characteristics On Din Rail Of Existing Dbs And Necessary Connection. Dp 40A. L&T. Make. , Supplying And Fixing 240/415 V Mcb Of Breaking Capacity 10Ka & C Characteristics On Din Rail Of Existing Dbs And Necessary Connection. Sp 6-32A. , Distribution Wiring In 1.1 Kv Grade 2X22/0.3 (1.5 Sqmm) Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire With 1X22/0.3 (1.5 Sqmm) Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire (Brand Approved By Eic) For Ecc In 19 Mm Bore, 3 Mm Thick Polythene Pipe Complete With All Accessories Embedded In Wall For Horizontal & Vertical Runs And In Suitable Size Pvc Casing-Capping (Precision Make) For Ceiling Portion Only, Incl. Necy. Fittings Etc. To Light/Fan/Call Bell Point With Modular Type Switch (Brand Approved By Eic) Fixed On Modular Gi Switch Board With Top Cover Plate And 2 No. Suitable Size “Ph & N” Copper Bar & Earthing Attachment Flushed In Wall Incl. Mending Good Damages To Original Finish [Only Pvc Casing-Capping On Ceiling And Remaining Portion Concealed]. Average Run 9 Mtr. , Distribution Wiring In 1.1 Kv Grade 2X22/0.3 (1.5 Sqmm) Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire (Brand Approved By Eic) In Suitable Size Pvc Casing-Capping (Precision Make) With 1X22/0.3 (1.5 Sqmm) Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire For Ecc, Incl. Necy. Fittings Etc. With S & F 6A 5 Pin Modular Type Plug Socket And Switch (Brand Approved By Eic) Fixed On 4 Module Gi / Pvc Switch Board With 3/4 Module Top Cover Plate On Wall Incl. Necy. Connection Making Earthing Attachment, Painting And Mending Good Damages To Building Works [Pvc Casing-Capping And Plug Box Both On Surface]. , On Board , Average Run 1.5 Mtr , Supply & Fixing 240V, Modular Socket (2 Module) Type Fan Regulator (Step Type) (Brand Approved By Eic) On Existing Modular Gi Switch Board With Top Cover Plate Incl. Making Necy. Connections Etc. , Fixing Only Modular Type Fan Regulator On Existing Modular Gi Switch Board With Top Cover Plate Incl. Making Necy. Connections Etc. , Distribution Wiring In 1.1 Kv Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire (Brand Approved By Eic) In 20Mm Size Pvc Rigid Conduit Fr (Precision Make) Incl. Necy. Fittings As Required. Page- , 2X 36/0.3 (2.5 Sqmm) + 1 X 22/0.3 (1.5 Sqmm) Ecc , Supply, Fitting & Fixing Of 400 Mm Dia High Speed Revoling Wall Mounted Fan. Hi-Flow. Crompton Make) , Led Flood Light 50 Watt. Jfl 50W-G. Lheecnp7pb6j050 Centura Neo Led Flood Light 50 W 6500 K Ip-66 , Supply, Fitting & Fixing Of Led Lamp 9W (Havells / Syska Make) , Supply Of 1200Mm Long Led Fl Light Set. (Havells/Wipro Make) , Supply Of 450Mm Dia Exhaust Fan Metal Body.Heavy Duty. (Havells / Epc / Crompton Greeves Make) , Supply Of 1200 Long A.C. Ceilingfan Complete With All Accessories. (Crompton Greeves/Usha Make) , Fitting & Fixing Of A.C Ceiling Fan . , S.I.T.C. Of 600 Mm Hi Speed Metal Body Stand Fan With Its Stand And All Accessories Complete. (Crompton Greeves Make). , Distribution Wiring In 1.1 Kv Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire (Brand Approved By Eic) In 20Mm Size Pvc Rigid Conduit Fr (Precision Make) Incl. Necy. Fittings As Required. , 2X 56/0.3 (2.5 Sqmm) + 1 X 36/0.3 (1.5 Sqmm) Ecc , Supply & Fixing 240 V, 2 Nos. 6A, & 2 Nos. 20A Plug Socket With Separate 2 Nos. 6 A & 2 Nos. 20A Modular Switch, (Brand Approved By Eic) On Modular Board In Wall Incl. S & F 240X200x65 Mm Modular Switch Boardand Making Necessary Connections As Required , Supply, Fitting & Fixing Of 12Mm Long Led Fl Set Complete Withh All Accessories On Wall. , Supply, Fitting & Fixing Of Led Ceiling Mounted Fittings.(Wipro / Bajaj / Syska Or Similarmake) 110Mm Dia. , Supply, Fitting & Fixing Of Led Ceiling Mounted Fittings.(Wipro / Bajaj / Syska Or Similarmake) 80 Mm Dia. , Supply, Fitting & Fixing Of Call Bell (Buzzer). , Supply & Fixing Of 225Mm Dia Exhaust Fan. (Crompton Greeves Make) , Distribution Wiring In 2 X 22/0.3 (1.5 Sqmm) Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire (Brand Approved By Eic) In 20Mm Size Pvc Rigid Conduit Fr (Precision Make), With 1X22/0.3 (1.5 Sqmm) Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire For Ecc, To Light/Fan/Call Bell Points With Modular Type Switch (Brand Approved By Eic) Fixed On Modular Gi Switch Board With Top Cover Plate And 2 No. Suitable Size “Ph & N” Copper Bar & Earthing Attachment Fixed On Wall Incl. Mending Good Damages To Original Finish. , 2X22/0.3 (Ph. & N) And 1X22/0.3 As Ecc , Average Run 10Mtrs. , Finishing The End Of Following Xlpe/Pvc Armoured Cable , 4 Core X 6 Sq.Mm. , 4 Core X 10 Sq.Mm. , Supply & Fixing Of Compressive Type Gland Complete With Brass Gland. , 4 Core X 6 Sq.Mm. , 4 Core X 10 Sq.Mm. , Supplying And Fixing Double-Door Spn Mcb Distribution Board With Ip-42/43 Protection, Concealed In Wall After Cutting The Wall & Mending Good The Damages To Original Finish Incl. Inter Connection With Suitable Size Of Copper Wire And Neutral Link & Provision For Earthing Attachment. (L&T2+2 Way). Enclosure (Ltsd04n) With 40 A 4 Pole Mcb. , Supply And Fixing Of Industrial Plug Socket 3 Phase 5 Pin (3 Phase, 1 Neutral And 1 Earting) With Metal Enclosure 3/4 Pole Mcbs All Accessories Complete. 32 Amp. , Supply And Fixing Of Industrial Plug Socket 3 Phase 5 Pin (3 Phase, 1 Neutral And 1 Earting) With Metal Enclosure 3/4 Pole Mcbs All Accessories Complete. 16 Amp. , Supply Of 4C X 25 Sqmm Aluminium Armoured Cable Of 1.1 Kv Grade. Make - Mescab/Polycab/Gloster , Supply Of 4C X 10 Sqmm Aluminium Armoured Cable Of 1.1 Kv Grade. Make - Mescab/Polycab/Gloster , Laying On Pole With Clamps:- Fixing Of Cable Along The Lenth Of O.H. Pole Incl. S & F Ms Pole Clamps Fabricated From 25 Mm X 6 Mm Ms Flat Incl. Painting , Finishing The End Of Following Xlpe/Pvc Armoured Cables By Crimping Method Incl. Supplying And Fixing Solderless Socket (Dowels Make), Tapes, Anticorrosive Paste & Jointing Materials : 4 Core 25 Sqmm Cable , Finishing The End Of Following Xlpe/Pvc Armoured Cables By Crimping Method Incl. Supplying And Fixing Solderless Socket (Dowels Make), Tapes, Anticorrosive Paste & Jointing Materials : 4 Core 10 Sqmm Cable , Supplying And Fixing 415 V Four Pole Mccb Of Breaking Capacity 25Ka/35Ka With Fixed Thermal And Fixed Magnetic / Adjustable Thermal And Fixed Magnetic Setting In Existing Dbs / Enclosure And Necessary Connection. 100 A Fp Legrand , Supplying And Fixing 240/415 V Mcb Of Breaking Capacity 10Ka & C Characteristics On Din Rail Of Existing Dbs And Necessary Connection. 63A Fp Legrand , Supplying And Fixing Mccb Ss Enclosure With Ip- 20/30 Protection, Pwder Coated Provision For Housing Four Pole (4P) Mccb, Concealed In Wall After Cutting The Wall & Mending Good The Damages To Original Finish / On Flat Iron Frame Incl. Painting, Connection & Provision For Earthing Attachment. Legrand , Supplying And Fixing Mcb Ss Enclosure With Ip-20/30 Protection, Powder Coated Provision For Two/Four Pole Mcb, Concealed In Wall After Cutting The Wall & Mending Good The Damages To Original Finish Incl. Painting, Connection & Provision For Earthing Attachment. 2 Way. , Supplying And Fixing 240/415 V Mcb Isolator On Din Rail Of Existing Dbs And Necessary Connection. 63 A Legrand Fp , Supplying And Fixing 240/415 V Mcb Of Breaking Capacity 10Ka & C Characteristics On Din Rail Of Existing Dbs And Necessary Connection. 6-32A Sp Legrand , Supplying And Fixing Double Door Horizontal Tpn Mcb Distribution Board With Ip-42/43 Protection, Concealed In Wall After Cutting The Wall & Mending Good The Damages To Original Finish Incl. Inter Connection With Suitable Size Of Copper Wire And Neutral Link & Provision For Earthing Attachment. 4 Way Enclosure (607715) Legrand , Supplying & Fixing Sheet Metal (16 Swg) Iron Clad Busbar Chambers On Angle Iron Frame On Wall, Incl. Earthing Attachment And Painting As Required – (As Per Drawing No. 470 Of Pwd Specification Book – May 1991). 4 Bars 415 V, 100/125 A Dimension Of Al. Bars [85Mm Long] 4 X 25X5mm Dimension Of Sheet Metal Box 500X150mm , Distribution Wiring In 1.1 Kv Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire (Brand Approved By Eic) In 20Mm Size Pvc Rigid Conduit Fr (Precision Make) Incl. Necy. Fittings As Required. 2 X 56/0.3 (4 Sqmm) + 1 X 36/0.3 (2.5 Sqmm) Ecc , Distribution Wiring In 1.1 Kv Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire (Brand Approved By Eic) In 20Mm Size Pvc Rigid Conduit Fr (Precision Make) Incl. Necy. Fittings As Required. 2 X 36/0.3 (2.5 Sqmm) + 1 X 22/0.3 (1.5 Sqmm) Ecc , Supply & Testing Of Industrial Type Led ( Box ) Double Fl Fittings 1200 Mm Long With Detachable Double Led Tube Set, Front Detachable Acrylic Cover. , Fixing Only Single/Twin Fluorescent Light Fitting Suspended 60 Cm Bellow The Ceiling With 2 No. 20 Mm Dia Ei Conduit (14 Swg) Supports Fixed With “L” Type Ms Clamp Whose One Side Fixed On Ceiling With Sutable Size 4 Nos. Fastener And Other Side Connected With The Conduit With Suitable Size Of Bolts And Nuts Incl. S&F Ei Conduit, “L” Type (125Mmx125mm) 6Mm Thick And 25Mm With Ms Clamps And Connecting The Length Of Pvc Insulated Wire And Mending Good Damages To Original Finish And Painting Etc. By 2X24/0.20 Mm (1.5Sqmm.) Flexible Copper Wire Of 1.50 Mt. Length. , Break Down Repairing Work Of Over Head Line With All The Arrangments And Tools , Wiring In 1.1 Kv Grade Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire (Brand Approved By Eic) Of Following Sizes In 25Mm Pvc Casing-Capping (Precision Make) Incl. Necy. Pvc Clips, Fittings Etc. , 2X 22/0.3 (1.5 Sqmm) + 1 X 22/0.3 (1.5 Sqmm) , 2X 36/0.3 (2.5 Sqmm) + 1 X 22/0.3 (1.5 Sqmm) Ecc , Supply Ofled Street Light Fittings Ip-65 Standard (Model:-Hpflp90w, Item Code- Lheparu7pn7j90)Make:- Havells , Fixing Only Outdoor / Street Light Type Fluorescent Light Fitting Or Mv Light Fitting Complete With All Accessories To Be Fixed /Projected From The Wall Of The Building Incl. Making Holes/Providing Clamping Arrangement & Necy. Gi Reducer As Required. S&F 40 Mm Gi Pipe (Isi-Medium) Quality 1.5 Mts. Average Length Having Suitable Bend S&F Necy. Length Of 1.5 Sqmm Pvc Insulated Single Core Stranded Annealed Copper Wire And Making Connections As Required And Mending Good Damages To Wall Incl. Painting Etc (Page-C3, Item No:-18). , Supply, Installation, Testing & Commissioning Of Lubricant Oil Filter (Fp A00300) For Ashok Leyland Make 30 Kva D.G. Set. , Supply, Installation, Testing & Commissioning Of Fuel Filter (Diesel Filter) For Ashok Leyland Make 30 Kva D.G. Set. , Supply, Installation, Testing & Commissioning Of Air Filterfor Ashok Leyland Make 30 Kva D.G. Set. , Replacement Of Battery With New One For 30 Kva D.G Set. , Supply & Insert Of Coolent For Ashok Leylandmake 30 Kva D.G. Set. , Supply & Insert Of Distilled Water For Ashok Leylandmake 30 Kva D.G. Set. , Supply Of Diesel Oil For The D.G. Set. , Supply & Replacement Of Pump Kit For Ashok Leyland Make 30 Kva D.G. Set. , Supply & Replacement Of Oil Pipes For Ashhok Leyland Make 30 Kva D.G. Set. , Supply, Changing & Filling Of Mobil Oil To The Engine, 30Kvaashok Leyland Make D.G. Set. , Repairing Of The Defective Wirings (Cause Due To Rodant Action) Ffor 30 Kvaashok Leyland Maked.G. Set. , Servicing Charges For The Entire 30 Kva Ashok Leyland Make D.G. Set With Its Engine With Other Parts. (Full Servicing). , Supply, Fitting & Fixing Of Led Ceiling Mounted Fittings.(Wipro / Bajaj / Syska Or Similarmake) , Supply, Installation, Testing & Commissioning Of Lubricant Oil Filter (Fp A00620) For Ashok Leyland Make 62.5 Kva D.G. Set. , Supply, Installation, Testing & Commissioning Of Fuel Filter (Diesel Filter) For Ashok Leyland Make 62.5 Kva D.G. Set. , Supply, Installation, Testing & Commissioning Of Air Filterfor Ashok Leyland Make 62.5 Kva D.G. Set. , Supply & Insert Of Coolent For Ashok Leylandmake 62.5 Kva D.G. Set. , Supply & Insert Of Distilled Water For Ashok Leylandmake 62.5 Kva D.G. Set. , Supply Of Diesel Oil For Thhe D.G. Set. , Supply, Changing & Filling Of Mobil Oil To The Engine, 62.5 Kva Ashok Leyland Make D.G. Set. , Repairing Of The Defective Wirings (Cause Due To Rodant Action) Ffor 62.5 Kva Ashok Leyland Maked.G. Set. , Servicing Charges For The Entire 62.5 Kva Ashok Leyland Make D.G. Set With Its Engine With Other Parts. (Full Servicing). , Supply, Testing, Fitting & Fixing Of Out Door Type Ip-65 Led Flood Light Fittings Isi Make (Model:-200W-G) Centura Neo Telescopic Flood Light Complete Withfastener Nuts And Bolts, Connection Wire Etc. Make:- Havells / Philips/Crompton Greeves. , Supply And Manufacturing Of Industrial Extension Cord Comprising Of5core 6 Sq.Mm. Copper Cable Multistrand 1100 Volt Grade With One End 5 Pin Metal Socket And One End 5 Pin Metal Top To Match With The Industrial Plug Socket. , Supply And Manufacturing Of Industrial Extension Cord Comprising Of3 Core 4 Sq.Mm. Copper Cable Multistrand 1100 Volt Grade With One End 3 Pin Metal Socket And One End 3 Pin Metal Top To Match With The Industrial Plug Socket. , Supply Of Xlpe Insulated 5 Core Multistrand 10 Sq. Mm 1100 Volt Grade Copper Cable. (Reputed Make) Isi Approved. , Supply Of Xlpe Insulated 5 Core Multistrand 6 Sq. Mm 1100 Volt Grade Copper Cable. (Reputed Make) Isi Approved. , Laying Of Cable As Below, After Cutting Floor/Pavement/Wall/ And Making Holes Incl., Embedding The Cable At An Average Depth As Below And Mending Good The Damages To Original Finish Incl. Removing The Rubbish , From 2.5 Sqmm To 35 Sqmm At An Average Depth Of 75 Mm In Floor/Pavement/Wall Etc. , Dismentalling Of 630A Vcb With Dismentlling All Its Ht Connections. , Dismentalling Of Apfc Panel With Dismentlling All Itsconnections And Dismentalling Of Ct Coil. , Shifting Of The Vcb To The Place As Directed By The Officer -In- Charge. , Shifting Of The Apfc Panel To The Place As Directed By The Officer -In- Charge. , Unearth Of Ht Cable Without Damaging It And Stagging It To Proper Position. , Laying Of One No. H.T. Cable185 Sqmm In Underground Trench 460Mm Wide X 760 Mm Average Depth, With Brick Protection On The Top Of The Cable With 8 (Eight) Nos. Bricks Per Mtr. Including Filling The Space Between The Bricks And Cable And Also The Trench With Shifted Soil, Levelling Up And Restoring Surface Duly Rammed. Page- F 2, Item No.:- 1 ((B). , Supply And Arrangement Of 1 No Straight Through Heat Sink Joint Of240 Sqmmhtcable .( Kalyani Feed Milling Plant ) Model No -3Mho_X_Aa_011E_3C0095_U40 Make- M-Seal. , Supply & Commissioning Of H.T. Terminal Jointint At Vcb Side. , Supply & Fixing 240V, Modular Socket (2 Module) Type Fan Regulator (Step Type) (Brand Approved By Eic) On Existing Modular Gi Switch Board With Top Cover Plate Incl. Making Necy. Connections Etc , Supply Of 1200 Long A.C. Ceilingfan Complete With All Accessories. (Crompton Greeves/Usha Make) , Supply Of 1Single Core X 70 Sq. Mm. Al. Conductor Cable.Xlpe Insulated, Overall Pvc Sheathed 1100 Volt Grade. , Laying Of Cable As Below, After Cutting Floor/Pavement/Wall/ And Making Holes Incl., Embedding The Cable At An Average Depth As Below And Mending Good The Damages To Original Finish Incl. Removing The Rubbish From 35 Sqmm To 95 Sqmm At An Average Depth Of 75 Mm In Floor/Pavement/Wall Etc. , Supplying & Fixing Medium Gauge Gi Pipe ( Isi-Medium) Protection With Necessary Fittings And Jointing Metarials As Required , Finishing The End Of Following Xlpe/Pvc Armoured Cable 4 Core X 70 Sq.Mm. , Supply & Fixing Of Compressive Type Gland Complete With Brass Gland.2 Core X 70 Sq.Mm , Supply Fitting & Fixing Of 250 Watt Copper Sodium Vapour Street Light Fittings Choke. , Supply Fitting & Fixing Of 250 Watt Copper Sodium Vapour Street Light Fittings Lamp. Son-T. , Distribution Wiring In 2 X 22/0.3 (1.5 Sqmm) Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire (Brand Approved By Eic) In 20Mm Size Pvc Rigid Conduit Fr (Precision Make), With 1X22/0.3 (1.5 Sqmm) Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire For Ecc, To Light/Fan/Call Bell Points With Modular Type Switch (Brand Approved By Eic) Fixed On Modular Gi Switch Board With Top Cover Plate And 2 No. Suitable Size “Ph & N” Copper Bar & Earthing Attachment Fixed On Wall Incl. Mending Good Damages To Original Finish. 2X22/0.3 (Ph. & N) And 1X22/0.3 As Ecc Average Run 10Mtrs. , Wiring In 1.1 Kv Grade Single Core Stranded Fr Pvc Insulated & Unsheathed Copper Wire (Brand Approved By Eic) Of Following Sizes In 25Mm Pvc Casing-Capping (Precision Make) Incl. Necy. Pvc Clips, Fittings Etc. 2X 22/0.3 (1.5 Sqmm) + 1 X 22/0.3 (1.5 Sqmm) , Supply Of 1200 Long A.C. Ceilingfan Complete With All Accessories. (Crompton Greeves/Usha Make) , Supply & Fixing Socket Type Fan Regulator (Step Type) (Brand Approved By Eic) On Existing Sheet Metal Switch Board With Bakelite/Perspex Top Cover By Screw After Making Housing For Regulator Knob By Cutting Bakelite/Perspex Top Cover Incl. Making Necy. Connections Etc. , Supplying & Fixing Iron Beam Fan Clamp Of Two Piece Type, As Per Approved Specification, Fabricated From 40 Mm X 9 Mm Ms Sheet Flat Suitable For Beam Having Flange Upto 150 Mm Wide – (As Per Drawing No. 476 Of Pwd Specification Book – May 1991) , Supply, Fitting & Fixing Of Led Lamp 9W (Havells / Syska Make) , Supply Of 1200Mm Long Led Fl Light Set. (Havells/Wipro Make) , Supply, Fitting & Fixing Of Ceiling Fan Down Rod As Per Site Requirement. 1500 Mm Long. , Supply Of 225Mm Dia Exhaust Fan Metal Body.Heavy Duty. (Havells / Epc / Crompton Greeves Make) , Fitting & Fixing Of A.C Ceiling Fan . , Supply, Fitting & Fixing Of Ceiling Fan Catcher As Per Site Requirement. , Supply & Fixing Of Fan Fixing Down Cord Copper Flexible Wire 2500 Mm Long. , Taxes & Duties , Add : G.S.T. @ 18% Of Rs. 33,52,409=70 I.E. Rs. 6,03,433=75 , Add : Cess @ 1% Of Rs. 39,55,843=45 I.E. Rs. 39,558=43