}

Tender For Modernization Work Of Veer Bahadur Singh Planetarium, Gorakhpur. (Part A And C) - Earth Work 2 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or , gorakhpur-Uttar Pradesh

Gorakhpur Development Authority has published Tender For Modernization Work Of Veer Bahadur Singh Planetarium, Gorakhpur. (Part A And C) - Earth Work 2 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or . Submission Date for this Tender is 03-04-2025. Earth Work Tenders in gorakhpur Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

48422886
Tender For Modernization Work Of Veer Bahadur Singh Planetarium, Gorakhpur. (Part A And C) - Earth Work 2 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or
Open Tender
Indian
Uttar Pradesh
Gorakhpur
03-04-2025

Tender Documents

Tender Details

Tender For Modernization Work Of Veer Bahadur Singh Planetarium, Gorakhpur. (Part A And C) - EARTH WORK 2 Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil (D.S.R. No-2.8.1/2023) 3 Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (D.S.R. No-2.25/2023) 4 Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement (AR) (lead upto 10km) (Morth Based) 5 CONCRETE WORK 6 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (D.S.R. No-4.1/2023) 7 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) (D.S.R. No-4.1.8/2023) 8 REINFORCED CONCRETE WORK 9 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (D.S.R. No-5.1/2023) 10 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). (D.S.R. No-5.1.2/2023) 11 Centering and shuttering including strutting, propping etc. and removal of form for all heights :(D.S.R. No-5.9/2023) 12 Foundations, footings, bases of columns, etc. for mass concrete (D.S.R. No-5.9.1/2023) 13 Lintels, beams, plinth beams, girders, bressumers and cantilevers (D.S.R. No-5.9.5/2023) 14 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. (D.S.R. No-5.22/2023) 15 Thermo-Mechanically Treated bars of grade Fe-500D or more (D.S.R. No-5.22.6/2023) 16 Brick work with common burnt Clay F.P.S (non modular ) brick of class designation 7.5 in foundation and plinth in: (D.S.R. No-6.1/2023) 17 Cement mortar 1:4 (1 cement : 4 coarse sand) (D.S.R. No-6.1.1/2023) 18 MILD STEEL AND IRON WORK 19 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.10.25.1 In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete (D.S.R. No-10.25.1/2023) 20 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works (D.S.R. No-10.25.2/2023) 21 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (D.S.R. No-10.1/2023) 22 Structural steel work riveted, bolted or welded in built up sections,trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (D.S.R. No-10.2/2023) 23 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete, (D.S.R. No-10.16/2023) 24 Hot finihed seamless type tubes(Taken 40kg per sqm weight)boundry grill (D.S.R. No-10.16.2/2023) 25 FLOORINGWORK 26 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.11.3.1 40 mm thick with 20 mm nominal size stone aggregate. (D.S.R. No-11.3/2023) 27 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thickgallaries (D.S.R. No-11.26/2023) 28 FINISHING 29 12 mm cement plaster of mix :1:4 (1 cement: 4 coarse sand) (D.S.R. No-13.4.1/2023) 30 Finshing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufactures specifications: (D.S.R. No-13.48.1/2023) 31 Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr/10 sqm 32 Painting steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. (D.S.R. No-13.4.3/2023) 33 DEMOLITION 34 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in-charge.(D.S.R. No-15.3/2023) 35 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 15.7.4 In cement mortar(D.S.R. No-15.7.4/2023) 36 Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. (D.S.R. No-15.25/2023) 37 Dismantling old plaster or skriting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meters lead. (D.S.R. No-15.56/2023) 38 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement: 2 stone dust) with an admixture of pigment matching the stone shade: (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately):(D.S.R. No-8.14/2023) 39 40 mm thick white sand stone - Exposed face machine cut and table rubbed with rough backing. (D.S.R. No-8.14.2.4/2023) 40 Providing and fixing cramps of required size & shape in RCC/CC/Brick masonry backing with cement mortar 1:2 (1 cement 2 coarse sand), including drilling necessary hole in stones and embedding the cramp in the hole (fastener to be paid separately). (D.S.R. No-8.7/2023) 41 Gunmetal cramps(2081/0.36)= 5780.55 say 5780.00 (D.S.R. No-8.7.1/2023) 42 Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete (D.S.R. No-8.8/2023) 43 Fastner with threaded dia 10mm (D.S.R. No-8.8.1.2/2023) 44 ELECTRICAL WORK 45 SUB-Head SH:- I (Wiring) Wiringforlightpoint/fanpoint/exhaust fanpoint/callbellpointwith1.5sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copperconductorsinglecorecableetcas required. (D.S.R. No-1.3) 46 (a) GroupC (D.S.R. No-1.3.3) 47 (b) GroupB (D.S.R. No-1.3.2) 48 (c) GroupA (D.S.R. No-1.3.1) 49 Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor singlecorecableinsurface/recessedsteel conduit,2waymodularswitch,modular plate ,suitable GI box and earthing the point with1.5sq.mm.FR PVCinsulatedcopper conductor single core cable etc as required. (D.S.R. No-1.4) 50 Wiringforgroupcontrolled(looped)light point/fanpoint/exhaustfanpoint/callbell point (without independent switch etc.) with 1.5sq.mmFRLSPVCinsulatedcopper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copperconductorsinglecorecableetc.as required. (D.S.R. No-1.54) 51 GroupC (D.S.R. No-1.54.3) 52 Wiring for light/ powerplug with 2X4 sq. mm FRLS PVC insulated copper conductor singlecorecableinsurface/recessedsteel conduitalongwith1No4sq.mmFRLS PVC insulated copper conductor single core cable for loop earthing as required. (D.S.R. No-1.5) 53 Wiring for light/ powerplug with 4X4 sq. mm FRLS PVC insulated copper conductor singlecorecableinsurface/recessedsteel conduitalongwith2Nos4sq.mmFRLS PVC insulated copper conductor single core cable for loop earthing as required. (D.S.R. No-1.6) 54 Wiring for circuit/ submain wiring alongwithearthwirewiththefollowing sizes of FRLS PVC insulatedcopper conductor, single core cable in surface/ recessed steel conduit as required (D.S.R. No-1.7) 55 (a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (D.S.R. No-1.7.1) 56 (b) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire (D.S.R. No-1.7.4) 57 (c) 4 X 6 sq. mm + 2 X 6 sq. mm earth wire (D.S.R. No-1.7.9) 58 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. (D.S.R. No-1.17) 59 (a) 6 x 1.5 sq. mm (D.S.R. No-1.17.6) 60 (b) 9 x 1.5 sq. mm(D.S.R. No-1.17.9) 61 Supplyinganddrawingfollowingpair0.5 sqmmFRLSPVCinsulatedcopper conductor,unarmoredtelephonecablein theexistingsurface/recessedsteel/PVC conduit as required.(D.S.R. No-1.18) 62 2 Pair (D.S.R. No-1.18.2) 63 Supplyinganddrawingco-axialTVcable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. (D.S.R. No-1.19) 64 Supplyingandfixingoffollowingsizes of steel conduit along with accessories in surface/recess including painting in case of surfaceconduit,orcuttingthewalland makinggoodthesameincaseofrecessed conduit as required. (D.S.R. No-1.20) 65 25mm (D.S.R. No-1.20.2) 66 Supplyingandfixingfollowingsize/ modules, GI box alongwith modular base & coverplateformodularswitchesinrecess etc as required. (D.S.R. No-1.27) 67 (a )2 Module (75mmX75mm) (D.S.R. No-1.27.2) 68 (b) 6 Module (200mmX75mm) (D.S.R. No-1.27.4) 69 (c )12 Module (200mm X 150mm) (D.S.R. No-1.27.6) 70 Supplying and fixing followingmodular switch/ socket on the existing modular plate &switchboxincludingconnectionsbut excluding modular plate etc. as required. (D.S.R. No-1.24) 71 5/6 amps switch (D.S.R. No-1.24.1) 72 3 pin 5/6 amp socket outlet (D.S.R. No-1.24.4) 73 Telephone socket outlet (D.S.R. No-1.24.6) 74 TV antenna socket outlet (D.S.R. No-1.24.7) 75 LAN socket outlet Cat 6-UTP- 1 Module (MR) 76 SupplyingandfixingsuitablesizeGIbox withmodularplaeandcoverinfronton surfaceorinrecess,includingproviding andfixing3pin5/6ampsmodularsocket outletand5/6amps modularswitch, connection,paintingetc.asrequired.(For light plug) (D.S.R. No-1.31) 77 SupplyingandfixingsuitablesizeGIbox withmodularplaeandcoverinfronton surfaceorinrecess,includingproviding and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required. (D.S.R. No-1.32) 78 Supplying&fixingtwoModuleGIbox wihmodularplateandcoverinfronton surface or in recess including providing and fixing 16 A modular socket outlet and 16 A modular SP MCB, C curve in one or two ModuleGIboxwihmodularplateand cover, including connections, painting etc. as required. (MR) 79 Supplyingandfixingtwomodulestepped type electronic fan regulator on the existing modular plate switch box including connectionsbutexcludingmodular plate etc. as required (D.S.R. No-1.25) 80 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. (D.S.R. No-1.53) 81 1 run of cable(D.S.R. No-1.53.1) 82 2 run of cable(D.S.R. No-1.53.2) 83 3 run of cable(D.S.R. No-1.53.3) 84 Sub-Head-II (Fitting & Accessories) 85 Supplying and fixing call bell/ buzzer suitableforD.C./A.C.singlephase,230 volts,completeasrequired.(suitablefor fixing in 2 Module box)(D.S.R. No-1.38) 86 Supply InstallatitonTesting and Commissioning of energy efficient direct fit (Retrofit)Polycarbonate/Glasshousing SMDMidPower20WattLEDtuberod (withintegraldriver& alumn. heatsink), onexisting fixture. systemlumenefficacy ≥100 lm/Watt output, internalsurge protectionof2.5KV,THD<20% ,p.f.≥0.95,CRI>80 , life time of minimum 35000BurningHourswith,70%ofintial Lumenmaintanedtilllifeends , CCT 3000°K /4000°K/ 5700°K/6000°K/6500°K (As per ANSI Bin), maximumpowerconsumptionshouldnot morethanthespecifiedratingandFixture (MR) 87 1200mm,Min.Lumensoutput2000lm LED Tube rod with Polycarbonate Housing 88 Supply InstallatitonTesting and CommissioningofIP20boxmadeout from1.2mmthickCRCAsheetsteelwith depth of minimun 30 mm and finished with powdercoating and suitable formounting LED tube including side overs, holders , internal wiring to illuminate the single sided connection LED tube. ( Without tube).(MR) 89 Suitable for 4 LED Tube shape fixturefor single rod 90 Supply,installation,testingand commissioningofheavyduty, 230Volts, single phase AC supply 300mm dia exhaust fanWITH900RPMdoubleballbearing, withenegyefficentmotor,louver/shutter, birdscreenincludingallaccessoriesand with 3 core flexible wire complete as required,intheextingopening,including making the hole to suit the size of the above fan,makinggoodthei/cfixingof louver/shutter etc.as required. (MR) 91 Supplying and fixing of 250mm sweep decorativeFreshairfanwithall accessories suitable for operation single phase 230 volt 50 cycle per second per sec. ACsupply etc.as required. inthe existing opening, includingmakingthe holetosuit the size of the above fan, making good the damage, connection, testing, commissioning earthing etc. as required. (MR) 92 Supply InstallatitonTesting and Commissioning of 1200mm sweepceiling fancapacitor type with double ball bearing complete with capacitor , suitable down rod , canopies , shackles, three number Al.blade & suitable for operation on 230 volt 50 Hz single phase AC supply i/c wiring the down rod of standard length (upto 30cm) with 1.5 sq.mm FR PVC insulated copper conductor singlecorecablei/cprovidingandfixing laminated sheet cover 3mm thick on the fan box etc as reqd. (Minimum Service Value 4.00 and above) (MR) 93 Supply InstallatitonTesting and Commissioning of IP-20 12 Watt LED Recessed / Surface Mounted, Round / Sqaure SMDMidPowerLEDDownlight withpowercoateddie-castaluminum housing with UV Stabilized non yellowish Diffuser with BIS complience 2.5KV surgeprotectedIsolateddriver,withShort & Open circuit protection, having efficiency > 85% . System Lumenefficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI>80,lifetimeofminimum50000 Burning Hours with , 70% of intial Lumen maintanedtilllifeends,CCT3000°K/ 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption shouldnotmorethanthespecifiedrating andFixtureshallbeof BISstandardand trade mark certificate ( T.C.). (MR) 94 Minimum lumen output 1300 lm (AR) 95 Supply InstallatitonTesting and CommissioningofIP-20LEDRecessed/ SurfaceMounted,Round/SqaureSMD MidPower18WattLED Downlightwith powercoateddie-castaluminumhousing withUV Stabilized nonyellowishDiffuser with BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life timeofminimum50000BurningHours with,70%ofintialLumenmaintanedtill life ends, CCT 3000°K / 4000°K/5700°K/6000°K/6500°K (As per ANSI Bin), maximumpowerconsumptionshouldnot morethanthespecifiedratingandFixture shallbeof BISstandardand trademark certificate ( T.C.). (MR) 96 Minimum lumen output 1950 lm 97 Supply InstallatitonTesting and Commissioning ofIP65IK08rated Integrated SMD Mid power LED bulk head typelightfixturemadefromPressureDie Cast AL housing suitable with integral driver, system lumen efficacy ≥100 lm/Watt output,THD<10%,p.f.≥0.95,CRI>80, life time of minimum 50000 Burning Hourswith ,70%ofintialLumen maintanedtilllifeends,CCT3000°K/ 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption shouldnotmorethanthespecifiedrating andFixtureshallbeof BISstandardand trademarkcertificate(T.C.).surge protection 4 KV.(MR) 98 Supplying installation testing and commissioning of Surface / Wall mounted LED Batten (10w LED mirror light) fitting systemlumensoutputnotlessthan 100,PowerFactor≥0.90,CRI>80,THD 10%,CCT5500-6600K(asrequired) extrudedAluminiumhousingprovidedfor efficient head dissipation with polycarbonatediffuser& integrated electronicdriverwithallaccessorieswith 1.5sqmm.,PVCinsulated,FRLScopper conductor, single core cable etc. as required & as per make & models in enclosed list of approved makes as required. (MR) 99 Supplying & fixing decorative wall bracket fitting made of poly carbonate with vitreous enamelledglass glob fixed on wall i/c1No.Retrofit10wattLEDlamp& connections,testing&commissioningetc complete as reqd. (MR) 100 Supplying installation testing and commissioningof400mmsweep,50W, 1370RPM,Wallfansuitablefor single phase 230 Volts 50 Hz AC supplyi/c testing, commissioning etc as required. (MR) 101 Sub Head-III (MCBs,MCB DBs, & Energy Meter) 102 Supplyingandfixingfollowingway, horizontal type three pole and neutral, sheet steel,MCBdistributionboard,415V,on surface/recess,completewithtinned copperbusbar,neutralbusbar,earthbar, dinbar,interconnections,powderpainted includingearthingetc.asrequired. (But without MCB/RCCB/Isolator)(D.S.R. No-2.4) 103 8way (4 +24),Double door(ForType V Qtr.) (D.S.R. No-2.4.3) 104 Supplyingandfixingoffollowingways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel,dustprotected,dulypowderpainted, inclusiveof200ampstinnedcopperbus bar, common neutral link, earth bar, din bar formountingMCBs(butwithoutMCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) (D.S.R. No-2.5) 105 12 way (4 + 36), Double door (For School) (D.S.R. No-2.5.3) 106 Supplying and fixing following way, single poleandneutral,sheetsteel,MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections,powderpaintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator) (D.S.R. No-2.3) 107 16way,Doubledoor(ForType-II&III Qtrs and light DB) (D.S.R. No-2.3.4) 108 SupplyingandfixingDPsheetsteel enclosure on surface/recess along with 25/32 A, 240 V “C” curve DP MCB complete with connections, testing and commissioningetc.asrequired.(ForStair Case Lights)(D.S.R. No-2.16) 109 Supplying and fixing following rating, four pole, 415 volts, MCB in the existing MCB DB complete withconnections, testing and commissioning etc. as required. 63 amps (MR) 110 Supplyingandfixing5ampsto32amps rating, 240 volts, C series, miniature circuit breaker suitable for inductive load of followingpolesintheexistingMCBDB complete with connections, testing and commissioning etc. as required.(D.S.R. No-2.10) 111 Single pole (D.S.R. No-2.10.1) 112 Double pole (D.S.R. No-2.10.3) 113 Supplying and fixing Cable End Box (Loosewirebox)(IP43)suitablefor following single pole andneutral, sheet steel,MCBdistributionboard,240V,on surface/recess,completewithtestingand commissioning etc. as required. (D.S.R. No-2.23) 114 For 14 way, Double door SPN MCBDB (D.S.R. No-2.23.4) 115 Supplying and fixing Cable End Box (Loosewirebox)(IP43)suitablefor following triple pole and neutral, sheet steel,MCBdistributionboard,415V,on surface/recess,completewithtestingand commissioning etc. as equired. (D.S.R. No-2.24) 116 For 8 way, Double door TPN MCBDB (D.S.R. No-2.24.3) 117 Supplying and fixing following rating, four pole, 415 volts, MCCB in the existing VerticalTPNDBcompletewith connections, testing and commissioning etc. as required. (D.S.R. No-2.2) 118 3 pole MCCB, 100A, 16KA (D.S.R. No-2.2.1) 119 Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/recess, complete with testing and commissioning etc. as required. (D.S.R. No-2.25) 120 Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc.The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. 121 Incoming 122 100 Amp MCCB-1 N0 123 Outgoning 124 63 Amp. MCCB-2 Nos. 125 Cat. A Pannel Cubicle Type 126 Cat. B Pannel Cubicle Type (S.I.No-811 (a) 127 32 Amp. MCCB-3 Nos. 128 Cat. A Pannel Cubicle Type 129 Cat. B Pannel Cubicle Type (S.I.No-811 (b) 130 SH IV( Meter Board & Panel ) 131 Distribution panel for School Building (Non-essential panel) 132 Supplying, installation, testing and commissioning of Indoor floor mounted modular,sectionalised,compartmentalized, dust&verminproof,extendabletypeMV cubiclepanelhaving 300mmdeepof suitable size notless then2.87sqmm fabricatedfrom CRCAsteelof2mm thick forframe work, enclosure and doors, 3 mm thick forgland plates withstiffeners wherever required i/c mounting base frame consistofMSchannelofsize100x50x6 mm,havingvibration freestructure chemically treated with seventankprocess beforepaintingforsurfacetreatmentand powder coated, with 4 nos. electrolytic gradehigh conductivity Aluminium busbar extensible type, DMC/SMC busbar supports, suitable for 3 phase 415 V 50 HZ ACsupplyi/callconnectionand interconnectionsinpanelboardwiththe suitablesizeFRLScopperwired/ALbus bars and 2 Nos. 25x5 mm copper earth bus bar through out the width of panel i/c earthing studs and detachable individual gland plate for each cable and having individualcompartmentforswitchgeari/c providing and fixing the following switchgearmounted thereoncomplete with connections & testing etc. as required. (Providing of connectors of required size insuitable quantity as per requirement.) 133 Note:-(i)Panelsizeindicatedisnominal.The actual sizeshall beasperthedrawing approved by the Department.(ii) All screws, nut bolts and earth stud are tobeusedofstainlesssteelonly.(iii) Panel have protection for Over Voltage and Under Voltage 134 All the MCCBs shall be Ics= 100% Icu 135 (II) INCOMING 136 a)250 Amps 36 KA FP MCCB with Ics= 100%Icu=36KA having thermal magnatic releases forO/L and S/C protection having extendablerotary handle, Spreader links, Aux. trip contact block, DigitalVAFmeterwithallrequired accesseries, LED indication lamp for R,Y & B, 2 Amp 10KA control MCB andtoggle switch with each MCCBi/c suitable size & capacity CTs as per requirement. 137 (III) OUTGOING 138 100 Amps FP MCCB with Ics= 100% Icu=30KAhavingthermalmagnaticreleases for O/L and S/Cprotection having extendable rotary handle, Spreader links for each MCCB 139 32 Amps TPN MCB (D.S.R. No-2.10.5) 140 DP MCB (32 amp) (D.S.R. No-2.10.3) 141 Danger notice plate (D.S.R. No-2.21) 142 Distribution panel for School Building(Essential panel) 143 Supplying, installation, testing and commissioning of Indoor floor mounted modular,sectionalised,compartmentalized, dust&verminproof,extendabletypeMV cubicle panel having 300 mm deep of suitable size fabricated from CRCA steel of2mmthickforframework,enclosure and doors, 3 mm thick for gland plates with stiffenerswhereverrequiredi/cmounting baseframeconsistofMSchannelofsize 100x50x6 mm, having vibration free structure chemically treated with seven tank process before paintingforsurface treatmentandpowdercoated,with4nos. electrolyticgradehighconductivity Aluminiumbusbar extensible type, DMC/SMCbusbarsupports,suitablefor3 phase415V50HZACsupplyi/call connectionandinterconnectionsinpanelboardwiththesuitablesizewiredcabble busbarsasperISand2Nos.25x5mm 144 copperearthbus bar throughout the width ofpaneli/cearthingstudsanddetachable individualglandplateforeachcableand havingindividualcompartmentforswitch gear i/c providing and fixing the following switchgearmounted thereoncomplete with connections & testing etc. as required. (Providing of connectors of required size in suitable quantity as per requirement.) 145 All the MCCBs shall be Ics= 100% Icu 146 (I) BUS BARS 147 4strip aluminium bus bars of minimum of 400 Amps, 16 KA for1 Sec. capacity with heat shrinkable coloured sleeves and includingDMC/SMCbusbarssupportsat requiredintervalscompleteforcross section, size supports at their spacing etc. for with standing fault level of 25 MVA for 1 Sec. The size of bus bar shall be provided considering the current densityof aluminium bus bar 1.0 Amp. /Sqmm. 148 Note:-(i)Panelsizeindicatedisnominal.The actual sizeshall beasperthedrawing approved by the Department.(ii) All screws, nut bolts and earth stud are tobeusedofstainlesssteelonly.(iii) Panel have protection for Over Voltage and Under Voltage 149 All the MCCBs shall be Ics= 100% Icu 150 (II) INCOMING 151 160Amps16KAFPMCCBwithIcs= 100%Icu=16KA having thermal magnatic releases forO/L and S/C protection having extendablerotary handle, Spreader links, Aux. trip contact block, DigitalVAFmeterwithallrequired accesseries, LED indication lamp for R,Y & B, 2 Amp 10KA control MCB andtoggle switch with each MCCB i/c suitable size & capacity CTs as per requirement 152 (III) OUTGOING 153 63 Amps FP MCCB withIcs= 100% Icu = 16KA having thermal magnatic releases for O/L and S/Cprotection having extendable rotary handle, Spreader links for each MCCB 154 32 Amps TPN MCB (D.S.R. No-2.10.5) 155 DP MCB (32 amp) (D.S.R. No-2.10.3) 156 Danger notice plate (D.S.R. No-2.21) 157 SH: V (Safety Equipment) 158 SITCofCarbonDioxide(CO2)gastype fireextinguisherof4.5Kg.capacitywith initialchargei/cdischargehoseandhorn, squeeze grip,release valve, locking arrangement,bracketwithtwoscrewand sleevei/cfixingonwall as required.(Fire extinguishershallbeoftype55BandISI marked confirming to IS: 15683) (MR) 159 Supplying&fixingofpowdertypefire extinguisher (stored pressur type confirmingtoIS:15683:2006)6Kg. capacitywithinitialrefillofISImarked ABCpowercompletedwithsqueezegrip, release valve, discharge pipe, pressure gauge,lockingsafetyclip,mounting bracketetc.i/cfixingonwallasrequired. (Fire extinguisher shall be ofMAP 90, type 3A, 55B) (MR) 160 Providing& fixingdangernotice plates madeofmildsteelatleast2mmthick& vitreousenameledwhiteonbothsides& withinscriptionsinsignalredcolouron front side as required. 161 Medium Voltage - Size 200mm x 150mm (D.S.R. No-2.21) 162 High Voltage- Size 250mm x 200mm (D.S.R. No-2.22) 163 Supply and fixing safety instruction chart in word duly framed with 5mm thick glass as required (Approx. Front area 1.20 Sq. Mtr.) (MR) 164 Providing of set of 4 Nos. 9.5 Litre capacity GI bucket painted in post office red colour with prior coat of red-oxide paint and writtenwithwhitepaintFIREand mounted on MSangle iron frame with bracketofappropriatesize&capacityi/c (MR) 165 filling sand etc. 166 Providing First Aid box as approved by St. John Ambulance Brigade/Indian Red Cross conforming to IS 2217-1963 (MR) 167 Supplyandfixingshocktreatmentchart dulymounted on a wooden frame with 5mm thickglass as required.(approximate front area 1.20 Sq. Mtr.) (MR) 168 Providing of rubber mat 1 mtr wide and 12 mmthicktowithstand3.3KVdielectric strength as per IS 5424 :1969 (MR) 169 Key board of size 30 cm x 30 cm made of iron dully painted and locking arrangement. (MR) 170 Rubber Gloves11KVgradeasper IS 4770-68 (MR) 171 SH:- VI (EARTHING) 172 Earthing with copper earth plate 600 mm X 600mmX3mmthickincluding accessories,andprovidingmasonry enclosurewithcoverplatehavinglocking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) asrequired. (D.S.R. No-5.5) 173 Providing and fixing 25 mm X 5mm copperstripin40mmdiaG.Ipipefrom earthelectrodeincludingconnectionwith brassnutbolt,spring,washerexcavation and re-filling etc. as required. (D.S.R. No-5.10) 174 Providing and fixing 25 mm X 5mm copperstriponsurfaceorinrecessfor connections etc. as required. (D.S.R. No-5.14) 175 Providingandfixing25 mmX 5mmG.I. stripin40mmdiaG.I.pipefromearth electrode including connection with G.I. nut, bolt, spring, washer excavation and re- filling etc. as required. (D.S.R. No-5.11) 176 Providingandfixing25 mmX 5mmG.I. strip on surface or in recess for connections etc. as required. (D.S.R. No-5.15) 177 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required (D.S.R. No-5.2) 178 Providing and fixing 6 SWG dia G.I. wire on surface or in recessnfor loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. (D.S.R. No-5.18) 179 SH:- VII ( Lightening arrestor ) 180 Providing and fixing of lightning conductor finial,madeof25mmdia300mmlong, G.I.tube,havingsingleprongat top,with 85mmdia6mmthickG.I.baseplate including holes etc. complete as required. (D.S.R. No-6.2) 181 Jointingcopper/G.I.tape(withanother copper/GItape,baseofthefinialorany other metallic object) byriveting / nut bolting/ sweating and soldering etc as required. (D.S.R. No-6.4) 182 Providing and fixing G.I. tape 20 mmX 3 mm thick on parapet orsurface of wall for lightningconductorcompleteas required.(For horizontal run) (D.S.R. No-6.7) 183 Providing and fixing G.I. tape 20 mmX 3 mm thick on parapet orsurface of wall for lightningconductorcompleteas required.(For vertical run) (D.S.R. No-6.7) 184 a)63Amp.25KA4PoleMCCBwith thermal magnetic release and Extended Rotatory handle- 1 No.(Incomer) 185 b)DigitalMultifunctionLEDmeterclass 1.0, 96 Sqmm - 1 No. 186 c) Set of 3 Phase LED indicating Lamp - 1 Set 187 d) 63 Amp. TPN MCB=3 Nos. 188 e) 32 Amp. DP MCB=2 Nos. 189 f)DOLstartersuitableforupto10.0HP pump(ratingupto40A)completewith Motorprotectionrelayhavinginbuiltover load,earthfault,lockedrotorandsingle phasing protection feature complete with all accessoriesandinternalwiringwith minimum 2.5 Sqmm PVC insulated copper conductorwire required foroperation, selectorswtichforlocal/remote, auto/manual/OFF operation Attempt startingdevice,timersandrelaysas required, pushbuttons for start/stop in manual mode, 3 phase LED indication lamps with individual Toggle switch, Pump ON/OFFLEDindication,ControlMCB etc. = 2 Nos. (MR) 190 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittingslikeelbows,tees,flanges,tapers, nutsbolts,gaskets etc.andfixingthe pipe onthewall/ceilingwithsuitable clamp/support frame and painting with two ormore coats of synthetic enamelpaintof required shade complete as required (D.S.R. No-18.7) 191 32 mm (D.S.R. No-18.7.2) 192 65 mm (D.S.R. No-18.7.5) 193 80 mm (D.S.R. No-18.7.6) 194 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 ratingwithbronze/gunmetalseatdulyISI marked complete with nuts, bolts, washers, gasketsconformingtoIS13095of following sizes as required 195 65 mm dia (D.S.R. No-18.11.3) 196 80 mm dia (D.S.R. No-18.11.4) 197 Providing,installation,testingand commissioning of stainless steelY-strainer fabricatedoutof1.6mmthickstainless steel, Grade304, sheet with3mm dia holes with stainless steel flange. 80 mm dia (D.S.R. No-18.15.1) 198 Providing,installation,testingand commissioningofnon-returnvalveof following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required 80mm dia (D.S.R. No-18.14.4) 199 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mmdiawithcastironwheelISImarked conforming toIS 5290 (Type -A) with blank Gunmetal/StainlessSteelcapandchainas required : (D.S.R. No-18.9) 200 Single headed Stainless steel (D.S.R. No-18.9.2) 201 Supplying and fixing 63 mm dia, 15 m long RRLhosepipewith63mmdiamaleand female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : (D.S.R. No-18.16) 202 Stainless Steel (Grade 304) (D.S.R. No-18.16.2) 203 Supplying&fixing63mmdiagunmetal short branch pipewith 20mmnominal internal diameter size nozzle conforming to IS903suitableforinstantaneous connectiontointerconnecthosepipe coupling asrequired : (D.S.R. No-18.18) 204 Stainless Steel (Grade 304) (D.S.R. No-18.18.2) 205 Supplyingandfixingfirst-aidHoseReel with MS construction spray painted in post officered,conformingtoIS884complete with the followingasrequired. 20mm nominalinternaldiawaterhose thermoplastic (Textile reinforced) type -2 as perIS:1258520 mm nominalinternaldia gun metal globe valve & nozzle. Drum and bracketsforfixingtheequipmetsonwall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket 30m (D.S.R. No-18.17.1) 206 Supplyingandfixingoffirebrigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MSpipeconnectionconformingtoIS 904 as required 207 2 way-100 mm dia M.S. Pipe (D.S.R. No-18.19.1) 208 Supplying and fixing air vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in heightwithairreleasevalveontopand flanged connectionto riser,drain arrangementwith25mmdiagunmetal wheel valve with required accessories, pressuregaugeandpaintingwithsynthetic enamel paint of approved shade as required. (D.S.R. No-18.20) 209 Providing&fixingofpressureswitchin M.S. pipe line including connectionetc. as required. (D.S.R. No-18.22) 210 Providingandfixinginpositionthe industrialtypepressuregaugeswithgun metal / brass valves complete as required. (D.S.R. No-16.8) 211 ELECTRICAL WORK - SUB- STATION 212 H. T. SYSTEM630KVA 11/0.433KV CSS 213 Supply, receiving, storing, inspection, handling, assembling, installation in correct aligned position,effecting proper connections, testing and commissioning of Outdoor type package type substation with continuous rating DYn11 Copper Wounded VCC-Cast Resin Dry Type Transformer with Off load tap links of +5% to - 5% @2.5% with WTI scanner. Class of Insulation: H, Temperature rise limits of 115 deg.C. Impedance of 5%(Subject to IS Tol.) with WTI scanner. MAKES- ABB/SIEMENS/GE (AR) 214 D.G. SET-1 320KVA-D.G. SET, Supply, installation, testing & commissioning of 3- phase, 415 volt, 1500 RPM, 50 HZ, Diesel generator set with prime rating capacity of 320KVA at 0.8 pf lagging diesel engine alternator set mounted on common base frame in outdoor type acoustic enclosure,battery, batter charger, return fuel cooler, anti vibration mounting pads including residential silencer, engine alternator,safeties with accessories as per specification complete as required. Diesel engine shall conform to IS:10000 and alternator shall be self excited complete with AVR to IS:4722. (AR) 215 D.G. SET-1 200KVA-D.G. SET, Supply, installation, testing & commissioning of 3- phase, 415 volt, 1500 RPM, 50 HZ, Diesel generator set with prime rating capacity of 200KVA at 0.8 pf lagging diesel engine alternator set mounted on common base frame in outdoor type acoustic enclosure,battery, batter charger, return fuel cooler, anti vibration mounting pads including residential silencer, engine alternator,safeties with accessories as per specification complete as required. Diesel engine shall conform to IS:10000 and alternator shall be self excited complete with AVR to (AR) 216 MAIN SUBSTATION-1 L.T PANEL : Design, Manufacturing, Supply, Commissioning & Testing of Main L.T. Panel Cum DG Synchronizing Panel -D.G. Set shall have AMF,LoadManagement,Synchronization facility through PCC Controller / Synchronizing Relay/PLCandalltheD.G.setchangeover facilitywithgridpower. Thepanel willbe totallyenclosedtypewith,freestanding,floor mounted,indoorduty,dust&verminproof,, front operated, electrical panel fabricated from 2 mmthickM.S.Sheet asperspecifications& drawing laid in this document and will be complete with the main and auxiliary bus bars, multimeter,indicationlamps,CTs,protection MCB, interconnection wiring, earth bus and will bepowder coated finish with 50 micron thickness.The panel shall be as per IEC439 (TTA).System Integrator of ABB(ArTu), Schneider(Prisma), Siemens(Sivako n).Authorizedcertificateandagreementcopy withOEMtobesubmitwhiledrawing approvals through contractor. (AR) 217 500KVAR CAPACITOR PANEL 218 INCOMING 219 1 Nos. 800 Amp TP MDO ACB 50KA (The release should be compatible with Bluetooth) Make : ABB(Emax)/Siemens(3WL)/Schneider(Masterp act NW 6E) (AR) 220 BUSBARS 221 1 Nos. 1000 Amp TPN busbars of aluminiumalloy as per SLD. 222 OUTGOING 223 12 stepped Automatic Power Factor Correctionrelay (APFC relay). 224 MAKES- ABB, EPCOS,SCHNIDER 225 HT CABLE-11KV(E)Supply of 3core standered aluminium conductor XLPE insulated PVC bedded, galvanised flat steel strip armoured cable CONFORMING TO IS 7098 (PART- 2) 2011 11KV grade at a depth of 900mm below ground level over a cushion of 100mm thick fine river sand all around and protected with well burnt bricks on sides and on top put across. The armoring of cable shall be properly connected with earth conductor by clamps etc. 120 sq.mm 3 core (PWD- 506a (F)) 226 supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 1 kV grade as required. 120 sq. mm (AR) 227 supplying and making Outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required. 120 sq. mm (AR) 228 Supply and burring of safe earthing electrode T-39Zn-zinccoated,length3000mm,outerdia 76.3mm x 3.2mm inner pipe 42.4mm x 2.6mm, terminal dia 12mm, coating 80-100 micron filledwithcrystallineconductivemixture (CCM)havinganticorrosiveandconductive property with 50 KGs activated soil (BFC) capable of reducing the soil resistivity with good mixtureofretainingcapacityalongwith30sq.cm C.I. frame with hinged curved and (S.I.No-726D) 229 Supply and laying of 25mmX3mm GI strip from earth electrode directly in the ground as required complete in all respect. (S.I.No-716) 230 Supplyandlayingof1800mmx 900mmx 12mm thick chequered rubber matting of testedquality. (S.I.No-1136) 231 Supply of3.5core and 4 core 1.1 KV LT power cable with solid/stranded compacted aluminium conductor, XLPE insulated colour coaded, Laid up, PVC inner shethed armoured with single layer of galvenized round wire or flat strip and over all ST-2 Grade PVC shethed conforming to IS 7098 (part-1) and ISI marked. 3.5 X 400 sq. mm (PWD 2018 (501T)) 232 As above but for 3.5 X 240 sq. mm (PWD 2018 (501R)) 233 As above but for 3.5 X 120 sq. mm (PWD 2018 (501O)) 234 As above but for 3.5 X 70 sq. mm (PWD 2018 (501M) 235 Supply and fixing of brass nickle plated compression gland for PVC insulated and armoured served shethed, underground cable including rubber ring etc. complete in all respect.The armouring of the cable shall be properly connected with the earth as per 236 As above but for 3.5 X 240 sq. mm (PWD 2018 (503R)) 237 As above but for 3.5 X 120 sq. mm (PWD 2018 (503O)) 238 As above but for 3.5 X 70 sq. mm (PWD 2018 (503M) 239 Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-incharge. 240 As above but for 3.5 X 240 sq. mm (PWD 2018 (504M)) 241 As above but for 3.5 X 120 sq. mm (PWD 2018 (504J)) 242 As above but for 3.5 X 70 sq. mm (PWD 2018 (504H)) 243 Bus-Bar Box Stand Alone Outdoor Type 630A (AR) 244 Bus-Bar Box Stand Alone Outdoor Type 400A (AR) 245 Supplying&fixingstandardshocktreatment chartsinEnglish&Hindidulyframedandcovered with glass. (S.I.No-1134) 246 Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least2mmthick,andvitreousenameledwhiteon bothsides,andwithinscriptioninsinglered colour on front side as required. (DSRNO-2.22) 247 Supplyand erection of ISI marked portable fire extinguishers, wall mounted type, wall brackets completeinallrespects,includingfixingon walls as per the direction of engineer-in-charge (Make:Minimax/RealValue/Firex/Safex).CO2 gas type 6.5 kg cap (S.I.No-1132A) 248 S/F of 410 S.P-.55 ISI & ISO certified S.T. pole 11 meter long grouted with 1:3:6 C.C. in brick ballast includingexcavationbackfillingetc. complete with all labour material T&P including plinth30cmaboveG.L.etc.completeinall respect. (S.I.No-613) 249 S/Concreting of Support (0.268cu.m/pole) (PO 2017 PA) 250 S/Paintingofpolewith2coatofAsianAl paint over one coat of red oxide including cleaning of dust vermin & making good complete in all respect. As per direction of E/I(S.I.No-634) 251 Making suitable earthing ofpole with 2.5mlong 20mmdia G.I. rod with 7/16 SWG G.I. wire as perUPPCLcompleteinallmaterial,labour T&P required for proper completion of work 252 Building Distribution Panel I/C-400 Amp. TPN-1 No 200 Amp.TPN-1Nos, 100 Amp.TPN-2Nos. & 63 mp.TPN-1Nos. (SPO 2017 PA) 253 SERVOKON make 630 KVA, 360 - 460 /400 Volts, 3 Phase, Balanced Type, Oil Immersed, Indoor, Rolling contact type (Linear Technology) Servo Stabilizer including First Filling of Fresh Oil and Standard Fittings & Accessories With Bypass Switch. 254 HIGH MAST & LUMINARIES WORK 255 16M HIGH MAST 256 16 Mtr High Mast totally Hot Dip Galvanized and suitable for wind velocity as per IS:875 Part 3,1987. latest version high mast lighting system along with headVframe, steel wire rope, 4 mm dia, single drum winch, galvanized lantern carriage suitable for 8 luminaire & its CGVboxes & lighting finial, integral type high powered reversible power tool for raising and lowering of latern carriage, gear box coupled with winch & torque limiter, foundation bolt of special steel with nuts, washer, anchor platesVtemplate LED beam flood light luminaire 200 watt, shallow foundation considering of safe soil bearing capacity at site as 10 T/sq mtr, at 2 mtr Depth twin dome aviation obstruction light, heavy gauge hot dipped galvanized lighting finals, feeder panel comprising main incoming switch MCBS, Time switch, contactor, reversing starter and protective system etc. as required and (A.R.) 257 Supply & Erection of 7 mtr Long Octagonal pole with Standard double arm bracket (1 mtr long) made up of 48.3mm dia G.I.pipe bracket suitable for road way LED Luminiares fitting as per attached specification with suitable foundation of cement,concrete 1:3:6 (1 cement:3 coarse sand:6 graded stone aggregate 40mm nominal size) foundation including excavation & refilling. dressing up of the plinth etc including 2 nos 60 watt LED fitting, MCB, Flexible pipe, flexible copper wire, socket etc as required (A.R.) 258 Supply and laying of Double walled Corrugated(DWC) pipes for underground power cable protection with IS:14930 Part-II mark on duly printed at every one meter interval along with the socket/coupler andT joint with IP 67 protection for coupling where ever required.The DWC pipe shall be rodent proof and fire resistant and size of Outer dia 90 mm and Inner dia 76 mm and Excavation of cable trench of 110 cm depth and 30 cm wide, in all kinds of soil and its refilling with the same excavated soft soi (A.R.) 259 Supply and burring of safe earthing electrode T-39Zn-zinccoated,length3000mm,outerdia 76.3mm x 3.2mm inner pipe 42.4mm x 2.6mm, terminal dia 12mm, coating 80-100 micron filledwithcrystallineconductivemixture (CCM)havinganticorrosiveandconductive property with 50 KGs activated soil (BFC) capable of reducing the soil resistivity with good mixtureofretainingcapacityalongwith 30sq.cmC.I.framewithhingedcurvedand masonryhousing. (For electrode terminal to switch board, cost of 25X3 GI strip will be extra Make: As proved in UPPWD and CPRI (S.I.No-726 D) 260 Supply and laying of 25mmX3mm GI strip from earth electrode directly in the ground as required complete in all respect. (S.I.No-716) 261 Automatic Light Panel 40A With Astronomical Switch(PWD SOR ELECT.807H/2018) 262 Supply of3.5core and 4 core 1.1 KV LT power cable with solid/stranded compacted aluminium conductor, XLPE insulated colour coaded, Laid up, PVC inner shethed armoured with single layer of galvenized round wire or flat strip and over all ST-2 Grade PVC shethed conforming to IS 7098 (part-1) and ISI marked. 4 X 16Sqmm (S.I.No-501(i) 263 Supply and fixing of brass nickle plated compression gland for PVC insulated and armoured served shethed, underground cable including rubber ring etc. complete in all respect.The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. (S.I.No-503A(i) 264 Supply and fixing of plain or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-incharge. 16Sqmm (S.I.No-504(D) 265 Planetarium, Auditorium, 3D Cinema & confrence Room 266 Supply, Providing, Fixing of Theatre seating Pop-up Theatre Chair made of Steel structure with pop-up mechanism to be auto fold if not needed, Providing P.P seat & back outer using seat and back P.U mould of high density covered with approved shade fabric cushioning foam should be of 30-32 density, HWD-16inchx16inchx16inch, , chair leg made of 2 mm thick M.S seat. All metal component powder coated with 40-50 microns. Embossed leg is providing for stability & strength of mounting pedestal of leg made of 14-gauge M.S sheet & embossed for heaving strength. The pedestal is to be fixed on floor with 100 mm length split hollow anchor/ fastener by inserting 4 mm dia M.S rod to split out the tails of anchor & griping hardly on the floor. armrest should be made of PVC/Plastic to carry Glass/bottle. Chair shall be for extra ergonomically comfort. Support spring and torsion spring shall be of grade 4454 1981 grade 2. Seat & back cushioned with molded no sagging polyurethane molded foam of special grade: - thickness (1) cushion-130 to 150 mm (2) backrest-80 to 100 mm. Fabric made of heavy duty & best quality cotton -jute mix with minimum synthetic material to give the desired finish. Color should be pre-approved by Engineer-in-charge 267 Supplying, Fitting and Fixing of wall paneling (one side) with 10 mm thick beveled edge polyester fiber board panel over supporting wood framing consisting 2” x 1.5” C.P Teak wood as horizontal members at 600 mm C/C (Max) Gap between wall and 10mm thick polyester wool insulation (25mm thick) whose specification is given below. Shade and texture of Polyester fiber board wall paneling should be got approved by the competent authority. Polyester wool insulation(a)Thickness 25mm,(b)Density 20kg/m3(c)Thermal Conductivity 0.034 w/m.k(d)Acoustic insulation with NRC 0.80(e)Fire retardant(f)Non-toxic and itching free(g)Temperature range 15 to 120 Degree CPolyester Fiber Board Panel(a)Size of each panel- 600 mm x 600 mm(b)Surface finish- Matt (c)Density- 200kg/m3(d)Thickness- 10mm(e)NRC 0.80(f)Fire Rating Euro Class B and ASTM E-84-08Thermal Condectivity-0.030 w/m.k 268 Suppling, laying and fixing of graphic loop pile carpet over an underlay of 6mm foam with adhesive over floor area as detail given bellow:Construction-Graphic loop pile Fibre 100% BCF Olefin Pile weight-550g/m2 ±5%Pile height -4-5 mmBacking-Action BackMake- 269 (PART - B) AUDITORIUM 270 Providing & fixing in position, heavy duty fully upholstered Auditorium chairs 520 mm c to c classroom type. Height of back should be less than 1030 mm with plastic protective cover on back and bottom having teak wood handles. Back to back distance is 1000mm. The auditorium chairs should be of following specifications 1. Powder Coated Heavy duty MS Stand. 2. Individually moulded , ergonomically designed seat and back cushions. 3.Moulded Polyurethane Foam cushion. PU foam density 48 – 52 kgs/cu.mtr 4. Moulded Polyurethane Foam manufactured in certified ISO 9001 facility to ensure consistency in density for longevity .5.Upholstered in Foam laminated stretch sandwich Fabric for clean finish and soft comfortable feel as per the colour & pattern selected by the client.6.Seat and Back should have moulded synthetic protective cover. 7. Wooden or PU armrest 65mm x 20mm - 330mm long . 8.Mounted using Anchor fasteners. 271 Supplying, Fitting and Fixing of wall paneling (one side) with 10 mm thick beveled edge polyester fiber board panel over supporting wood framing consisting 2” x 1.5” C.P Teak wood as horizontal members at 600 mm C/C (Max) Gap between wall and 10mm thick polyester wool insulation (25mm thick) whose specification is given below. Shade and texture of Polyester fiber board wall paneling should be got approved by the competent authority. Polyester wool insulation(a)Thickness 25mm,(b)Density 20kg/m3(c)Thermal Conductivity 0.034 w/m.k(d)Acoustic insulation with NRC 0.80(e)Fire retardant(f)Non-toxic and itching free(g)Temperature range 15 to 120 Degree CPolyester Fiber Board Panel(a)Size of each panel- 600 mm x 600 mm(b)Surface finish- Matt (c)Density- 200kg/m3(d)Thickness- 10mm(e)NRC 0.80(f)Fire Rating Euro Class B and ASTM E-84-08Thermal Condectivity-0.030 w/m.k 272 Suppling, laying and fixing of graphic loop pile carpet over an underlay of 6mm foam with adhesive over floor area as detail given bellow: Construction-Graphic loop pile Fibre 100% BCF Olefin Pile weight-550g/m2 ±5% Pile height -4-5 mm Backing-Action Bac kMake- 273 LCD Projector with screen 274 Sound System 275 Computer 276 Furniture (Other then theatre chair) Podium table (4), Podium(2), stage chair (10) 277 (PART - C) CONFERENCE ROOM 278 Supplying, Fitting and Fixing of wall paneling (one side) with 10 mm thick beveled edge polyester fiber board panel over supporting wood framing consisting 2” x 1.5” C.P Teak wood as horizontal members at 600 mm C/C (Max) Gap between wall and 10mm thick polyester wool insulation (25mm thick) whose specification is given below. Shade and texture of Polyester fiber board wall paneling should be got approved by the competent authority. Polyester wool insulation(a)Thickness 25mm,(b)Density 20kg/m3(c)Thermal Conductivity 0.034 w/m.k(d)Acoustic insulation with NRC 0.80(e)Fire retardant(f)Non-toxic and itching free(g)Temperature range 15 to 120 Degree CPolyester Fiber Board Panel(a)Size of each panel- 600 mm x 600 mm(b)Surface finish- Matt (c)Density- 200kg/m3(d)Thickness- 10mm(e)NRC 0.80(f)Fire Rating Euro Class B and ASTM E-84-08Thermal Condectivity-0.030 w/m.k 279 Suppling, laying and fixing of graphic loop pile carpet over an underlay of 6mm foam with adhesive over floor area as detail given bellow:Construction-Graphic loop pile Fibre 100% BCF OlefinPile weight-550g/m2 ±5%Pile height -4-5 mmBacking-Action BackMake- 280 LCD Projector with screen 281 Conference Sound system (26 Seats) 282 Computer 283 A/V Console 284 Furniture (Other then theatre chair) Conference table (1),chairs(50) 285 (PART - D) 3D CINEMA 286 3D Projector with screen 287 Sound System /3D i-Glass Set/ System 288 Computer 289 HVAC Work 290 Hi-side Equipment 291 VRV/VRF units : 292 Supply, Installation, testing & Commissioningof modular type Variable Refrigerant Flow/ Variable Refrigerant Volume aircooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 16HP ODU, microprocessor based Controller, top discharge type condensing unit(s), with R407c/R410a/EQUIVALENT Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at 40°C Celcius Ambient Conditions and work even at 56°C ambient temperature without tripping. The unit shall be suitable to work on 380V - 460V , 3Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required.- The Outdoors shall be be having 34 Liters suction accumlators. The COP at AHRI conditions shall not be less than 3.9- IEER not less than 6.8 .Unit shall include support stand with two coat of enmel panint as per specification. Offered ODU model shall be with highest possible COP by OEM IncludeLifting, shifting, assemblling &positioning of the equipment comprising of the following and complete as per specification/drawingsand as directed by Engineer In Charge 293 Outdoor Units 294 112 HP (28X4) 295 36 HP (24+12) 296 42 HP (28+14) 297 42 HP (28+14) 298 36 HP (24+12) 299 VRF/VRV INDOOR AC UNIT 300 DUCTABLE UNITS 301 Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRF/VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 302 22 TR 8800 cfm, Floor mounted ducted unit with Pre filter 303 8 TR 3200 cfm, Ceiling supended mounted ducted unit Pre filter 304 6 TR 2400 cfm, Ceiling supended mounted ducted unit Pre filter 305 VRF/VRV INDOOR AC UNIT (CASSETTES UNITS): 306 Supply,installation,testing and commissioning of following minimum capacity 4-way flowCassette Type Indoor ceiling mounted unit equipped with synthetic washable media prefilter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil,electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remote control etc., suitable for operation on single phase 230V±10%, 50 Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will beat air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 307 Capacity:- 4.0 Tr 308 Capacity:- 3.2 Tr 309 Capacity:- 2.8 Tr 310 Capacity:- 2.3 Tr 311 Capacity:- 1.5 Tr (Compact type) 312 Centralised Remote Controller 313 Supply, Installation, testing & Commissioning PC compatible Centralised Remote Controller (CRC) for the Entire Indoor and Outdoor Equipment Configuration for Above systems. CRC shall be compatible on BACnet over IP / Modbus BMS protocol. As per specification/drawingsand as directed by Engineer In Charge. The Controller shall be capable of setting timers for units to turn on/off every defined duration for Working Stand-by systems. 314 Cordless remote 315 Corded Remote 316 Y Joints 317 Supply, installation, testing & commissioning pair of Ref Nut/Y-joints brass for indoor and outdoor units of suitable size as per requirement. As per specification/drawingsand as directed by Engineer In Charge. 318 Installation, Testing and Commissioning of VRV indoor and outdoor unit including Supporting 319 A-Outdoor Units 320 B-Lifting, Shifting and positioning of ODU and ducted units 321 C-Supply and Installation of Iron stand for ODU 322 Supply,installation,testing and commissioning including vaccumization and nitrogen testing of following nominal sizes of soft /hard drawn copper refrigerant piping for VRF /VRV system , complete with fittings , with suitable adjustable ring type hanger supports,jointing/brazingincludingaccessories,insulated withXLPE/class-O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as a given below for suction and liquid lines , all accessories as per specifications etc as required . 323 6.4mmdia(OD)(Softdrawn) with19mmthick insulation 324 9.5mmdia(OD)(Softdrawn)with19mmthick insulation 325 12.7mmdia(OD)(Softdrawn)with 19mm thick insulation 326 15.86mmdia(OD)(Softdrawn)with 19mm thick insulation 327 19mmdia(OD)(Harddrawn)with 19mmthick insulation 328 22.2mmdia(OD)(Harddrawn)with 19mm thick insulation 329 28.5mmdia(OD)(Harddrawn)with 19mmthick insulation 330 31.8mmdia(OD)(Harddrawn)with 19mmthick insulation 331 34.9mmdia(OD)(Harddrawn)with 19mmthick insulation 332 38.1mmdia(OD)(Harddrawn)with 19mmthick insulation 333 41.27mmdia(OD)(Harddrawn)with19mmthick insulation 334 44.45mmdia(OD)(Harddrawn) with19mmthick insulation 335 53.97mmdia(OD)(Harddrawn)with19mmthick insulation 336 SupplyfixingWiringforcircuit/submainwiringalongwithearthwirewiththe followingsizesof FRLS PVC insulatedcopperconductor, single core cable in surface/ recessed medium class 20 mm dia FRLS PVC conduit complete with all accessories, supports as required. 337 2 X 1.0 sqmm with 20 mm dia pvc conduit 338 Supply,installation,testingandcommissioningofG.I rectangular ductwork complete with supports, elbows ampers/splitters/vanes/ hangers/supports /rubbe gaskets and ancialliary items as per approved drawings and specifications of thefollowing sheet thickness.: 339 18 Guage (G.I Duct) 340 20 Guage (G.I Duct) 341 22 Guage (G.I Duct) 342 24 Guage (G.I Duct) 343 Duct Insulation 344 Supplying and fixing of following thickness duly laminated aluminumfoilof matfinishclosedcellNitrilerubber(ClassO) insulation on existing duct after applying suitable adhesive for Nitrilerubber.Thejointsshallbesealedwith50mm wideand3 mmthickselfadhesivenitrilerubbertapeinsulationcompleteas per specifications and as required. 19 mm thickness 345 Duct Accoustic Lining : 346 Supplyandfixingofacousticliningofsupplyairductandplenum with25mm thickresinbondedglasswoolhavingdensityof32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mmcentretocentrecoveredwithReinforcedPlastic tissuepaper and 0.5 mm thick perforated aluminum sheet fixed to inside surface ofductswithcadmiumplatednuts,bolts,stickpins,CPRX compound etc. complete as required and as per specifications. 347 Grilles/Diffusers/Louvers/VCDs/FDs : 348 Supplying & fixing of powder coated extruded aluminiumReturnAirGrills withlouversbutwithoutvolumecontrol dampers complete as required. 349 Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core. 350 Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core. 351 Supply,installation,testingandcommissioningofVolumecontrol ductdamper completewithneoprenerubbergaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. 352 Supplying,Fixing,testingandcommissioningoffiredampersin supplyair duct/mainbranchandreturn airpathasandwhere requiredofrequiredsizesi/c controlwiring,thedampershallbe motorizedandspringreturnsoastoclosethe damperinthe eventofpowerfailureautomaticallyandopenthesameincase of power being restored. The spring return action shall be inbuiltmechanismand notexternallymounted.Thedamper shall also be closed in the event of fire signal complete as required and as per specifications. 353 Fire Damper 354 Actuator 355 Drain Piping : 356 Supply,installation,testingandcommissioningofofCPVCpipeshavingthermal stability for condesate water including wrapping of 9mm thick class 0 nitrile rubber insulationwithsuitableadhesivewith all CPVCplainandbrassthreadedfittings including the pipes with clamps 1metre spacing.This including jointing of pipes with onestepCPVCsolventcementandtestingofjointscompleteasperdrgand specifications 357 50 mm dia 358 40 mm dia 359 32 mm dia 360 Supplying and installing following size of perforated Hot DippedGalvanised Ironcabletray(Galvanisationthicknessnot lessthan50microns)withperforation notmorethan17.5%,in convenientsections,joinedwithbends,reducerandallaccessories connectors, suspended from theceilingwithG.I.suspendersincludingG.I.bolts&nuts etc. as required. 361 100 mm width X50 mm depth X1.6 mm Thickness 362 150 mm width X50 mm depth X1.6 mm Thickness 363 300 mm width X50 mm depth X1.6 mm Thickness 364 Control Panelfor VRV/VRF Units : 365 Supply, installation, testing and commissioning of alised floor/wall mounted type made of 2 mm thick steel sheet duly painted for outdoor uses IP65 Protection complete as per thespecifications and drawing and as detailed below : 366 1 no. 630 Amps TPN MCCB incomer with KWH 367 meter, phase indicating lamps with control fuse & toggle switch, voltmeter and selector switch, 368 ammeter with CTs and selector switch 369 1 set 630 Amps triple pole with neutral Al. Bus Bars duly sleeved 370 8 no of 63 Amps MCCB outgoing for VRV OD units 371 4 no of 40 Amps MCCB outgoing for VRV OD units 372 Cable 373 Supply, laying, testing and commissioning of following sizes of XLPE insulated PVC sheathed aluminium/ copper conductor armoured / unarmoured cable of 1.1 KV grade on existing cable tray / surface including saddles, clamps etc. complete as required & approved by the Engineer In Charge. (Tagging to be provided with aluminium strips on both the ends as approved). 374 4 Core 16 Sqmm. Copper . Armd 375 4 Core 10 Sqmm. Copper. Armd 376 4 Core 4 Sqmm. Copper. Armd 377 3 Core 2.5 Sqmm. Copper unarmd 378 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required 379 SOLAR GRID SYSTEM (25 KW) 380 Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthingmounted on Aluminium/GI structure of suitable strength with followincomponents complete as required:a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. SolaPhotovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watcapacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugand other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPinsulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along witsupplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. 381 Site Campus (PA System) 382 Public announcement system (outdoor & Indoor) 383 JBL AWC82 (All -Weather 8 Compact 2-way Coaxial Loudspeaker)(117199.00 -25% = 87899.25) 384 Crown Xli 3500 (Two- channel Power Amplifier) (165182.00 -25% = 123886.50) 385 Harman DBX DriveRack VENU360 (Loudspeaker Management System) (151388.00 -25% = 113541.00) 386 Audio Technica 49QL (Gooseneck Microphone) + AT86685 (Microphone Base Stand)(27494.00 -25% = 20620.50) 387 1.5 mm Amoured Speaker Cable 388 CCTV & surveillance 389 64 Channel Nvr CPPLUS/Dahuaa 390 C.C.T.V 2 MP IP Camera out Door 391 CCTV 2 MP IP Camera Indoor 392 16 Channel Port POE D. Link/Giga 393 4 U Rack with PDU 394 15 U Rack with PDU 395 Dlink Gigabyte switch 16 channel 396 HDD 8 TB 397 PVC Box 398 Wireless Mouse 399 Cat 6 Cable 305 m length 400 Rj 45 connector 401 LED TV 32 inch 402 Cable AC electric 403 HDMI cable 404 Instalation charge 405 Fire Fighting systems 406 Supply &erection of ISImarked portable fire extinguishers, wall mounted type, wall brackets complete in all respect as per standard item with al accessories,delivery hose&nozzle whereever required, includingfixingonwallsasper the directions of E/I. (MAKE:-CEASE FIRE) 407 CO2 gas type 4.5 kg Capacity (IS:2878) 408 D.C.P. type 5 KG. capacity (ABC) 409 ABC Trolley 25 kg Capacity. 410 ABC Type ceilling Mounted 5 KG. capacity. 411 Supply, erection and testing of ISI markedM.S. pipes (Class C - heavy duty) and specials etc, (as per 1S:1239) for above ground laying for hydrants and sprinkler system including transportation of materials upto the worksite, cutting the pipes to required length, edge preperation, welding, fixing / erection of pipes including specials i.e. bends, tees, reducers, flanges, expansion joints wherever required, washers, nuts, bolts etc. in proper position including all supports at maximum 3 meter spacing by 3 mm thick G.I. hangers / clamps / Tie rod supports with G.I. nuts, bolts, anchor fastner and washer for hydrant / sprinkler piping, jointing by welding, aligning the pipe line, painting with two primer coat by zinc chromate primer and two coats of syntheticenamelfireredcolour, providing tapping for pressure gauges and forother instruments etc. Hydrostatic testing of system as specified, flushing & cleaning bywater etc. complete as perdrawings &direction ofthe Engineer-in-charge.The quotedrates shall also include for making holes in masonry / RCC slab, wail, chases in wall, providing sleeves in RCC wall & slabs with puddle flanges whereever required & making good the same by sealing the opening to original conditions. 412 upto 40mm dia. pipe threaded forged fittings and threaded joints shall be provided and for 50mm dia & above pipes welded joints with MS / malleable iron fittings shall be used.(MAKE : Jindal (Hissar) / Bharat / Indian Tube / Prakash) 413 80 NB 414 100 NB 415 Supply, laying & jointing of IS! marked Mild Steel pipes (class C - heavy duty) (as per IS: 1239) including all fittings i.e. reducer, elbows, tees, flanges, washers, nuts, boltsetc. below ground including transportation of all materials to work site, earth work in excavation in all kinds of soil upto 1.50 meter depth, edge preparation, Jointing by welding, laying the pipes in trenches in proper alignment, providing 150 mm thick fine sand layer above pipe, back filling the trenches in layers of 20 cms, consolidation of each deposited layer, watering, ramming, disposal of surplus earth within a lead of 200 m and as directed, hydrostatic testing of the complete pipe work, providing 1:2:4 concrete thrust blocks of suitable size at all bends, tees and junctions with form works, completing the work in all respect as per drawings & direction of the E/I. 416 The rates will include providing and laying 4 mm thick Pypkote tar based polymeric corrosion arotection tape over two coat of zinc chromate orimer as per manufacturers specs, as directed andasper!S:10221.(MAKE : Jindal (Hissar) / Bharat / Indian Tube Co / Prakash) 150 NB 417 Supply & installation of ISI marked single headed 63 mm dia. gunmetal / Stainless steel Hydrant Valve, 80 mm dia flanged inlet with 63 mm female instantaneous outlet confirming to IS : 5290 on the fire wet riser/down comer, including making 80 NB pipe connection with riser along with 100 mm dia dial pressure gauge of calibration 0-15 kg/sq cm, fixing the landing valves in proper positions, including supply of nuts, bolts, gaskets, caps, chains etc. testing the hydrant and completing the work in all respect as per directions of the Engineer in-charge. (MAKE : Firex / Safex / Minimax / Newage) 418 Supply, fixing in position, testing ISI marked cast iron double flanged sluice valves as per IS: 14846-2000, (PN 1.6 mPa) with SS stem, bolts, nuts, 3 mm thick rubber gaskets including transporting to worksite, Complete as per drawings & directions o! the Engineer-in-charge.(MAKE : Kirloskar /Venus / IVC / Zaloto / Audco). 150MMNB 419 Supply & fixing in position iSl marked cast iron double flanged butterfly valves (PN 1.6 MPa) as per IS:130g5, with disc, shaft, seating rings, internal fastening, nuts, bolts including transporting to worksite, 3 mm thick rubber gaskets etc. including testing, Complete as per drawings & directions of the Engineer-in-charge.(MAKE : Kirloskar /Venus / IVC / SKS / Zaloto / Audco). 100MMNB 420 Supply & fixing in position ISl marked cast iron double flanged dual plate type Non Return Valves (PN 1.6 Mpa) as per IS : 5312, part - I, including transportation to worksite, supply & fixing SS nuts, SS bolts, 3 mm thick rubber gaskets, complete with testing as per direction of the Engineer - in -charge.(MAKE : Kirloskar /Venus / IVC / Zaloto/ Audco). 100 NB 421 Supply, fixing, testing & commissioning of 20 mm bore and 30 meter long hose (high pressure rubber braided hose pipe as per IS:444) and hose reel suitable for 10 kg/sqcm operating pressure for first aid fire fighting conforming to IS : 884, with 180° full swing drum, fixing brackets, shut off gun metal / Stainless steel nozzle, 40 mm dia. hand fever operated isolating ball valve, connecting directly from the riser through 40 mm dia. G.l.pipe with sockets, elbows, nipples etc. including - providing operating instructions on a metal plate and fixing it near hose reel. The system shall be complete in all respects as per drawings and directions of Engineer-in-charge. (MAKE : Dunlop / Goodyear / Newage) 422 Providing gun metal/Stainless steel ISl marked 63 mm. dia. male Instantaneous pattern short branch pipes & 20 mm dia. Nozzle as per IS : 903, suitable for 10 kg/sqcm operating pressure and suitable for interconnections to hose pipe coupling as required. (MAKE : Minimax/Firex/Safex/Newaae) 423 Providing ISI marked RRL (IS : 636, type-A) fire hose pipe 15 meter long and 63 mm dia with ISI marked (IS : 903) gun metal / Stainless steel mate and female coupling bound and rivetted to hose pipes with copper rivets and copper wire complete as required. (MAKE:Jayshree / Newage) 424 Providing & fixing 100 mm dia dial pressure gauge complete in all respects. 425 Supply & installation of cast iron body 2 way 63 mm dia male instantaneous inlet coupling complete with cap and chain for fire brigade connection conforming to IS : 904 and making connection with fire fighting pipe or under ground water tank, completing the work in all respect as per the directions of the Engineer-in-charge. (MAKE: Firex / Safex / Minimax / Newage) 426 Providing and fixing weather proof standard fire hose cabinet (900 mm x 600 mm x 450 mm) outdoor type made of not less than 14 SWG MS sheet having glassed hinged door (5 mm thick clear glass) including necessary locking arrangement with handle for housing hydrant valve, two nos.15 meter long fire hose pipes, branch pipe as required as per drawings, including brackets for mounting accessories, painting (one coat primer and two coat of fire red colour). The cabinet shall be mounted on self standing mounted type MS Angle iron frame as required. The words FIRE HOSE to be painted on the box. 427 Constructing brick masonary chamber 90 x 90 x 120 cm inside with FPS brick work in cement mortar 1:5(1 cement: 5 fine sand) for sluice valve with S.F.R.C. cover and frame (heavy duty HD-20 grade designation), 560 mm internal diameter confirming to IS:12592, total weight of cover and frame to be not less than 182 Kg in cement concrete 1:2:4 and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) necessary excavation, foundation concrete 1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size) & inside plastering with cement mortar 1:4 (1 cement: 4 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design . 428 Supply & Fixing automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump). (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS: 1520. (b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.(d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 900 lpm at 35 m Head 429 Providing and fixing danger notice plate of 200 mm X 150 mm made of mild steei at least 2 mm thick vitreous enamelled, white on both sides and with inscription in signal red colour on front side as required. PWD Miscellaneous Item. 430 providing and fixing of shock treatment chart written in English and Hindi both properly framed and glass covered as required. 431 Providingand layingof ISImarked Aluminium conductor, XLPE insulated, armoured, served, sheathed Cable 1100 V grade with terminal joints by palm or pin type cable sockets (lugs), insulating with tapes, double compression type brass and nickle plated compression glands. On surface, the cable run shall be on MS cable trey or fixed on M.S. clampsetc. of suitablesizeor asdirectedby engineer-in- charge, complete in all respects, in ground the cable shall be laid at a depth of 750 mm from ground Level including a cushion of 75 mm thick. Fine river sand alround, duly protected by bricks on sides and top including excavation and back filling of soil or laid in RCC hume pipe as calledfor. The armouring shall be property connected with the earth conductor by clamps etc. PWD Shedule. 16 sqmm 4 core. 432 Providing, fixing, testing and commissioning of manual call points break glass type housed in 16 SWG sheet steel housing in surface/ recess including making connections with wires complete in all respects and as per specifications. The manual call point should have an indicator, which should blink in stand by condition. 433 Providing, fixing, testing and commissioning of electronic hooters (hooters shall also be able to work as public address system sounders) housed in 16 SWG sheet steel housing suitable for wall / ceiling and surface / recess mounting including making connections with wires complete in all respects and as per specifications. 434 Providing, fixing, testing and commissioning of fire alarm main control and indicating panel, solid state modular card type to monitor all local/zonal control panels on each floor or directly detectors as per the case, puiser, timer for dual stage alarm facility complete with indicators, floor selector switches, stand by SMF battery, battery charger, battery box, connections to building automation system / Fire fighting pump panel etc. including Public Address System complete in all respect and as per specifications and requirements. The panel shall have facility of automatic dialling to 5 telephone numbers in case of alarm. The main control panel should give a distinct visual signal of the isolation of zone from the local indication panel. If all the zones at the local panel are isolated or if the fuse of the LCP gets blown, it should result in an open circuit fault indication at the Main Panel. 12 Zone main control panel. 435 Supply and laying of ISI marked Copper conductor PVCinsulated cable as per IS 1554 PVC sheathed 1100 volts grade.On surface the cable run shall be fixed by Gl clamps etc. of suitable size or on existing cable tray complete in all respect.The armouring of the cable shall be properly connectedwiththe earth conductor including fixing of palm or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and makingconnections complete in all respect including supply of clamps, lugs, tape etc. complete upto the satisfaction of E/I. 2x1.5 sq mm armoured 436 Providing, fixing, testing and commissioning of wall / ceiling mounted 240 Volts AC 5 W CFL type illuminated EXIT signs,150 x 400 mm having self glowing letters on its front white sheet with embossed asFIRE EXIT including the cost of builtin rechargeable batteries and battery charger suitable for 30 minute operation complete as required. 437 Providing and fixing SS strainer fabricated out of 1.6 mm thick stainless sheet with 3 mm dia holes with SS flange at the suction pipes of fire pumps. 100 mm dia 438 (a) Optical/Photoelectric type Heat detectors as per IS : 11360 -1985 of photo-optic sensing chamber, 12/24 volt D.C., twin visual alarm indicator Blink in stand by and Steady in alarm (LEDs) complete in all respectswith baseas required. 439 Supply, installation and testing of cylindrical type flanged air vessel tank, 450 mm dia, 2 m long and of 10 mm thick M.S., common for a set of fire pumps including flanged connection, suitable supporting legs etc. The air vessel tank shall be provided with 25 mm dia air release valve, stop cock, safety valve, pressure gauge, 25 mm dia drain valve, suitable pressure switches to operate main and jockey pumps, tested to min 20 KG/cm2 complete including painting with synthetic enamel paint of approved shade with all accessories as per direction of the E/I. 440 Wi-Fi & Communication 441 Wi-fi & Communication System 442 Architectural lights 443 Supply and fixing of 20 Watt LED COB Down light Round cast aluminum body. 444 Supply and fixing of 6 watt landscape/spot light. 445 Supply and fixing 5 watt of profile lights 446 Supply and fixing of 18 watt urban decorative garden LED Bollards light 447 Supply and fixing of 36 watt LED surface mounting panel 600x600mm False ceiling Light. 448 Astronomy & Indian Space Programme Gallery 449 Wall Panelling structure- 600 mm x 600mm horizontal and vertical grid frame made of 50mm x 50mm pine wood battons, upto height 2500mm.6MM water proof ply/acp sheet fixed and nailed with appropriate glue or adhesive. 450 Astronomy & Indian Space Programme themed panels made of laminated, digitally printed, 3D effects and pasted on structure 451 Astronomy & Indian Space Programme themed flooring made of linoleum, aluminium grid automobiles flooring, acrylic flooring as required with theme 452 Illuminated signage, illustrations, and information panels made of led, 3D graphics,and traslite 453 LCD/LED screens monitor 42 and 55 total 454 3D LCD laser projector for projection Mapping aligned and intigration with software and central server 455 Server

Key Value

Document Fees
INR 5900 /-
EMD
INR 4671500.0 /-
Tender Value
INR 9.34 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail