}

Tender For Execution Of Works Related To Supply And Installation Of Submersible Pump Sets, Panels, Cables And Other Allied Works Including Commissioning Of Tube Well Under District Division I Jodhpur - 1 Supply & Installation Of 3 Phase Isi Marked Subme, jodhpur-Rajasthan

Public Health Engineering Department has published Tender For Execution Of Works Related To Supply And Installation Of Submersible Pump Sets, Panels, Cables And Other Allied Works Including Commissioning Of Tube Well Under District Division I Jodhpur - 1 Supply & Installation Of 3 Phase Isi Marked Subme. Submission Date for this Tender is 04-04-2025. Submersible Pump Tenders in jodhpur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

48415652
Tender For Execution Of Works Related To Supply And Installation Of Submersible Pump Sets, Panels, Cables And Other Allied Works Including Commissioning Of Tube Well Under District Division I Jodhpur - 1 Supply & Installation Of 3 Phase Isi Marked Subme
Open Tender
NCB
Rajasthan
Jodhpur
04-04-2025

Tender Documents

Tender Details

Tender For Execution Of Works Related To Supply And Installation Of Submersible Pump Sets, Panels, Cables And Other Allied Works Including Commissioning Of Tube Well Under District Division I Jodhpur - 1 Supply & Installation of 3 phase ISI marked submersible motor pump set of three star or better ratingof BEE and asper IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make offollowing dutyconditionwithrequiredaccessoriesincluding making connectionsuitablefortubewell/DCB.Thejob includesloweringof motorpump,installationof completefitting&accessories,jointingof electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. 2 Up to 5.5 KW (7.5 HP) & head up to 120 mtr. 3 Up to 5.5 KW (7.5 HP) & head above 120 mtr. 4 7.5 KW (10 HP) & head up to 120 mtr. 5 7.5 KW (10 HP) & head above 120 mtr. 6 9.3 KW (12.5 HP) & head up to 120 mtr. 7 9.3KW (12.5 HP) & head above 120 mtr. 8 11 KW (15 HP) & head up to 120 mtr. 9 11 KW (15 HP) & head above 120 mtr. 10 13 KW (17.5 HP) & head up to 120 mtr. 11 13 KW (17.5 HP) & head above 120 mtr. 12 15 KW (20 HP) and above, head up to 120 mtr. 13 15 KW (20 HP) and above, head above 120 mtr. 14 Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star- delta starter, over load relay,ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators,lightingarrangementetc.completesuitable forthree phasepumpset.Thepanelshouldhave spaceforenergymeter( suppliedby DISCOM). All theseequipmentsshallbehousedby panel boxmade outfrom18gaugeM.S.Sheetwithpowdercoating.Panel should be ofminimum size 900 x 600 x 450 mm withStand ( made of angleironofsize35x35x5mm) duly bolted/screwedwithenclosurebox having4legs, eachleg’slength18anddoubledoorincludingin built locking system.The legs should be embedded in M- 15 cement concrete platform.ThesizeofCCplatform shouldbeequalorbiggerthanthe base size of panel having height of at least 200 mm from ground level. The panelshouldhaveopeningofsuitablesizeinfrontof spacefor energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt ACSupply. 15 Above 5 HP and up to 10 HP 16 Above 10 HP and up to 15 HP 17 Above 15 HP and up to 20 HP 18 Above 20 HP and up to 30 HP 19 Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc. 20 3 core 4.0 Sq.mm 21 3 core 6.0 Sq.mm 22 3 core 10.0 Sq.mm 23 3 core 16.0 Sq.mm 24 Supply & Fixing XLPE insulated / P.V.C. sheathed cable of1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make ingroundasper IS:1255includingexcavationof30cmx75cmsize trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testingetc. as required of size. 25 10.0 Sq.mm, 4 core 26 16.0 Sq.mm, 4 core 27 25.0 Sq.mm, 3.5 core 28 35.0 Sq.mm, 3.5 core 29 PlateEarthingasperIS:3043withG.I.Earthplateof size600mmx 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20 mm dia. G.I. B class watering Pipe including all accessories like nut, bolts, reducer,nipple,wiremeshedfunnel,andC.C.finishedchamber coveredwithhingedtypewithlocking arrangementC.I.Cover, C.I. Frameofsize300mmx 300mmcompletewithalternatelayersofsalt and coke/charcoal, testing of earth resistance as required. 30 Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc. for holding the riser pipe assemblyof submersible pump set. 31 Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and twonumber 25x3mmMSflatweldedonbothends betweenpipe& flange, rubber washer & nut bolts etc.complete in all respect. 32 32 mm dia 33 50 mm dia 34 65 mm dia 35 80mm dia 36 Providing&Fixingofdoubleflanged,CIbody,ISI markedNRVofapproved make of following sizes 37 65 mm dia 38 80 mm dia 39 Providing,installation,testingandcommissioning ofCentrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at synchronised speedof 3000 RPM withrequisiteMOCimpeller, priming funnel, cock,suitableflangesatsuctionanddeliveryside. Pumpshall havecommonshaftforpumpandmotor. Motorshallbesuitablefor working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected onC.C. foundation/crosschannels/RSJ frameblockwithsuitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification,scopeofworkanddirectionofEngineer inChargeof following power rating, suitable for prescribed duty conditions mentioned in TD. 40 Centrifugal Monoblock Pump set (Single Stage) 41 2.2 KW (3.0 HP) 42 3.7 KW (5.0 HP) 43 5.5 KW (7.5 HP) 44 7.5 KW (10 HP) 45 9.3 KW (12.5 HP) 46 11.0 KW (15 HP) 47 15.0 KW (20.0 HP) 48 18.5 KW (25.0 HP) 49 Centrifugal Monoblock Pump set (Double Stage) 50 3.7 KW (5.0 HP) 51 5.5 KW (7.5 HP) 52 7.5 KW (10.0 HP) 53 9.3 KW (12.5 HP) 54 11.0 KW (15.0 HP) 55 15.0 KW (20.0 HP) 56 Providing and fixingat site with necessary packing,Horizontal Centrifugal Split Casting pumps with 4 poleinduction motor operating at synchronisedspeed ofspeed1500RPMasperIS12615:2011or amendeduptodate,CIcasingandcasingring,SS316impeller,SS410 Shaft and shaft sleeve, coupling guard, common base plate, foundationbolts,Cement concretefoundationetc.completewithall respectas perthespecificationandscopeofworkanddirection of Engineer in Charge of following range of duty conditions. Note: Duty condition of required pump shall also be mentioned in BoQ. 57 Discharge 20 to 30 LPS and head 20 to 30 M 58 Discharge 20 to 30 LPS and head 31 to 40 M 59 Discharge 20 to 30 LPS and head 41 to 50 M 60 Discharge 20 to 30 LPS and head 51 to 60 M 61 Discharge 20 to 30 LPS and head 61 to 70 M 62 Discharge 20 to 30 LPS and head 71 to 80 M 63 Discharge 20 to 30 LPS and head 81 to 90 M 64 Discharge 31 t0 40 LPS and head 20 to 30 M 65 Discharge 31 t0 40 LPS and head 31 to 40 M 66 Discharge 31 t0 40 LPS and head 41 to 50 M 67 Discharge 31 t0 40 LPS and head 51 to 60 M 68 Discharge 31 t0 40 LPS and head 61 to 70 M 69 Discharge 31 to 40 LPS and head 71 to 80 M 70 Discharge 31 to 40 LPS and head 81 to 90 M 71 DOL STARTER 3.7KW (5 HP )- : For 2motors (1 W+ 1S)I/C -MCB 32A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0- 500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1),Amp.SelectorSwitch (1),C.T.30/5ACL1.05VA(3),Indicating Lights( Red-1, Yellow -1)(2), IndicatingLights(Blue-1 )(1), Control MCB 6A SP 10 KA C Curve (3)andO/G- MCB25A,TP,10KA,CCurve(2),Power Cont12ATPAC3Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (7-10A )(2), ControlMCB6ASP10KACCurve (2),SinglePhasePreventer(2), IndicatingLights(Red- 1,Green-1,Amber-1)(6),PushButton22.5( Red- 1,Green-1)(4),SelectorSwitch1Pole,2Way(2), Capacitor 440VAC Heavy Duty MPP Type 2 Kvar (2) 72 DOL STARTER 5.5 KW (7.5HP)- : For 2motors (1 W+ 1S)I/C -MCB 40A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0- 500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1),Amp.SelectorSwitch (1),C.T.30/5ACL1.05VA(3),Indicating Lights( Red-1, Yellow -1)(2), IndicatingLights(Blue-1 )(1), Control MCB 6A SP 10 KA C Curve (3) andO/G- MCB25A,TP,10KA,CCurve(2),Power Cont12ATPAC3Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (7-10A )(2), ControlMCB6ASP10KACCurve (2),SinglePhasePreventer(2), IndicatingLights(Red- 1,Green-1,Amber-1)(6),PushButton22.5( Red- 1,Green-1)(4),SelectorSwitch1Pole,2Way(2), Capacitor 440VAC Heavy Duty MPP Type 2 Kvar (2) 73 STAR DELTA STARTER 7.5 KW (10.0 HP)- : For 2motors (1 W+ 1S)I/C -MCB 63A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0- 500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1),Amp.SelectorSwitch (1),C.T.60/5ACL1.05VA(3),Indicating Lights( Red-1, Yellow -1)(2), IndicatingLights(Blue-1 )(1), Control MCB 6A SP 10 KA C Curve (3) andO/G- MCB32A,TP,10KA,CCurve(2),Power Cont18ATPAC3Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (7-10A )(2), ControlMCB6ASP10KACCurve (2),SinglePhasePreventer(2), IndicatingLights(Red- 1,Green-1,Amber-1)(6),PushButton22.5( Red- 1,Green-1)(4),SelectorSwitch1Pole,2Way(2), Capacitor 440VAC Heavy Duty MPP Type 5Kvar (2), S/D Timer(2) 74 STAR DELTA STARTER 9.3 KW (12.5 HP)- :For 2 motors (1 W+ 1S)I/C -MCB 63A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0- 500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1),Amp.SelectorSwitch (1),C.T.60/5ACL1.05VA(3),Indicating Lights( Red-1, Yellow -1)(2), IndicatingLights(Blue-1 )(1), Control MCB 6A SP 10 KA C Curve (3) andO/G- MCB40A,TP,10KA,CCurve(2),Power Cont18ATPAC3Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (7-10A )(2), ControlMCB6ASP10KACCurve (2),SinglePhasePreventer(2), IndicatingLights(Red- 1,Green-1,Amber-1)(6),PushButton22.5( Red- 1,Green-1)(4),SelectorSwitch1Pole,2Way(2), Capacitor 440VAC Heavy Duty MPP Type 5Kvar (2), S/D Timer(2) 75 STAR DELTA STARTER 11.0 KW (15.0 HP)- :For 2 motors (1 W+ 1S)I/C -MCB 63A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0- 500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1),Amp.SelectorSwitch (1),C.T.60/5ACL1.05VA(3),Indicating Lights( Red-1, Yellow -1)(2), IndicatingLights(Blue-1 )(1), Control MCB 6A SP 10 KA C Curve (3) andO/G- MCB40A,TP,10KA,CCurve(2),Power Cont25ATPAC3Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (9-13A )(2), ControlMCB6ASP10KACCurve (2),SinglePhasePreventer(2), IndicatingLights(Red- 1,Green-1,Amber-1)(6),PushButton22.5( Red- 1,Green-1)(4),SelectorSwitch1Pole,2Way(2), Capacitor 440VAC Heavy Duty MPP Type 7.5Kvar (2), S/D Timer(2) 76 STAR DELTA STARTER 15.0 KW (20.0 HP) :For 2 motors (1 W+ 1S)I/C-MCCB100ATPN25KAWithT/MBasedOver Current&Short Circuit Protection (1),Spreaders (2),Extended Rotary Handle (1) , Analog Voltmeter 96*96mm(0-500V)(1),VoltSelectorSwitch(1), Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 100/5A CL1.05VA(3),Indicating Lights(Red-1,Yellow-1)(2),Indicating Lights(Blue-1)(1),Control MCB6ASP10KACCurve(3)andO/G- MCCB63ATPN25KAWithT/MBasedOver Current&Short Circuit Protection (2), Power Cont 32ATP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (12-18A )(2), Control MCB 6A SP 10 KAC Curve(2),SinglePhasePreventer(2),IndicatingLights(Red- 1, Green-1,Amber-1)(6),PushButton22.5(Red-1,Green-1)(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPPType 7.5Kvar (2), S/D Timer(2) 77 STAR DELTA STARTER 18.5 KW (25.0 HP)- :For 2 motors (1 W+ 1S)I/C-MCCB125ATPN25KAWithT/MBasedOver Current&Short Circuit Protection (1),Spreaders (2),Extended Rotary Handle (1) , Analog Voltmeter 96*96mm(0-500V)(1),VoltSelectorSwitch(1), Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 125/5A CL1.05VA(3),Indicating Lights(Red-1,Yellow-1)(2),Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) andO/G- MCCB100ATPN25KAWithT/MBasedOver Current&Short Circuit Protection (2), Power Cont 32ATP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (16-24A )(2), Control MCB 6A SP 10 KAC Curve(2),SinglePhasePreventer(2),IndicatingLights(Red- 1, Green-1,Amber-1)(6),PushButton22.5(Red-1,Green-1)(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 10 Kvar (2), S/D Timer(2) 78 STAR DELTA STARTER 22.0 KW (30.0 HP)- :For 2 motors (1 W+ 1S)I/C-MCCB125ATPN25KAWithT/MBasedOver Current&Short Circuit Protection (1),Spreaders (2),Extended Rotary Handle (1) , Analog Voltmeter 96*96mm(0-500V)(1),VoltSelectorSwitch(1), Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 125/5A CL1.05VA(3),Indicating Lights(Red-1,Yellow-1)(2),Indicating Lights(Blue-1)(1),Control MCB6ASP10KACCurve(3)andO/G- MCCB100ATPN25KAWithT/MBasedOver Current&Short Circuit Protection (2), Power Cont 40ATP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (23-32A )(2), Control MCB 6A SP 10 KAC Curve(2),SinglePhasePreventer(2),IndicatingLights(Red- 1, Green-1,Amber-1)(6),PushButton22.5(Red-1,Green-1)(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPPType 12.5 Kvar (2), S/D Timer(2) 79 Providing and fixingat site with necessary packing,Horizontal Centrifugal Split Casting pumps with 4 poleinduction motor operating at syncronised speed of speed 1500 RPM as per IS 12615: 2011 or amended up to date , CI casing and casing ring, SS 316 impeller, SS 410 Shaft and shaft sleeve, coupling guard, common base plate, foundation bolts, Cement concrete foundation etc. complete with all respect as per the specification and scope of work and direction of Engineer in Charge of following range of duty conditions.Note: Duty condition of required pump shall also be mentioned in BoQ. 80 Discharge 20 to 30 LPS and head 51 to 60 M 81 Discharge 20 to 30 LPS and head 61 to 70 M 82 Discharge 20 to 30 LPS and head 71 to 80 M 83 Discharge 41 to 50 LPS and head 41 to 50 M 84 Discharge 71 to 80 LPS and head 61 to 70 M 85 Discharge 141 to 160 LPS and head 61 to 70 M

Key Value

Document Fees
INR 5000 /-
EMD
INR 240000.0 /-
Tender Value
INR 1.20 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail