| 1 | Supply of Prestressed concrete pole 9.0 metres long, bottom width 263 mm, Top width 145 mm, breadth 114 mm with all accessories, as required |
| 2 | Supply and Erection of Dead end /eye hook/suspension clamp assembly for stringing of LT AB cable. Suspension Clamp assembly |
| 3 | Supplying and erection of galvanised \"D\" iron clamps complete with shackle insulator (100 mm X 110 mm),G. I. bolts, nuts and washers, coach screws etc. as required. |
| 4 | Erection of RCC/ PCC pole of following length in brick ballast and ramming thefoundation, finishing with 150mm thick cement concrete (1:3:6) layer on top withincluding excavation and refilling etc as required. Above 8.0 metre and upto 11.0 metre |
| 5 | Fabrication , Supplying,Installation,testing,Commissioning of 12 mts.high mast System with its accessories ,Mast shaft shall be in one section , hot dip galvanized 4mm thick(Single dip ) inside and out sides and suitable for wind velocity as per IS 875 part3 .There shall be in longitudinal seam weld per section and No circumfrential weld. It should also included accessories For High Mast head frame ,2 point suspension system with steel wire rope 5mm dia. (7/19construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos. flood lightluminaries symmitrically And its control gears boxes and lighting finial ,the mast shall have integral manual type mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC(1:2:4) shallow foundation of size 1m(L)x1m wide and 2 mtr deep I/C excavation of earth , providing cutting,bending and placing in position ,reinforcement of cold twisted bars of 12 mm dia -2100 mm long(approx)-16 nos and reinforcement of cold twisted bar of 8mm dia -3700 mm(approx) -13 nos (with 150mm spacing) as reqd with positioning of foundation bolts and providing DWC HDPE pipe for cable entry or exit as required for the high mast considering the safe soil bearing capaciy at site as 10T/sqm at 2 mts .Depth with all material i/c 4 Nos S.P MCB ,63 A Dp Isolator etc as reqd Logo/Name of manufacturer shall be embossed on the pole. Galvanization as per relevant IS |
| 6 | Supply and fabrication of pole protection system made up of 8SWG steel wire mesh of size25mmx75mm rectangular with 50mmx50mmx6mm MS angle iron for supporting the mesh and grounding the protection system in suitable quality of CC etc as reqd. |
| 7 | supply of XLPE Insulated PVC Sheathed Al. Conductor Armoured Cable for working voltage upto 1.1kV confirming to IS-7098 of following sizes: (a) 2x10 sqmm |
| 8 | supply of XLPE Insulated PVC Sheathed Al. Conductor Armoured Cable for working voltage upto 1.1kV confirming to IS-7098 of following sizes: (b) 4 x 25 sq.mm |
| 9 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 10 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nutbolt &spring washer spaced at 50mm) |
| 11 | Supply of 140 watt LED Street Light/Flood Light Luminaire fitted with lens made of pressure die cast aluminium housing and toughened glass cover complete with the following specifications as per relevant IS(a) Total System Wattage :140 Watt ± 5%(b) Luminaire Efficacy -130Lumens/watt minimum) (c) Power factor >0.95(d) Protection Class IP66( e ) LED Packageshall be Ceramic Base.(f) Multi Chip. Array, Multi Die, Mid Power, Integrated Arrays and COB type Chip are not permitted( g ) Operating Current of LED < 70% of rated maximum forward current, limited to a minimum of 350 mA and maximum of 1000 mA.(h) Wattage of LED Package : Onewatt to Five watt maximum (i) CRI >70(i) THD <10% for complete fixture(k) Operating Voltage - 110-320 V, 50Hz +/- 3%(l) The driver must have thermal Protection against75 deg C ambient temperature with internal SPD of minimum 6 KV. Separate Compartment for Driver(m)Life ofStreet Light: Minimum 50,000 hrs |
| 12 | Installation and Commissioning of Street Light/Flood Light etc as required |
| 13 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sqmm FRLS PVCinsulated single core cable as earth wire in existing surface/ recessed steel/PVCconduit including dismantling as required.Group C |
| 14 | SITC of surface mounting LED luminaire suitable for 1X20 watt LED rating box type complete with extruded aluminium batten prewired with high efficient LEDs with the following: a) Total System Wattage 20 ±5% Watt b) Luminaries effucacy ≥ 100 lumens/watt c) Power factor ≥ 0.95 |
| 15 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan withBrush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos.blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM,350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 16 | SITCof Pillar box size 900 mm x 450mm x 250mm suitable for mounting incomer of 250 A MCCB/Main switch 4 Pole and energy meter 3 phase complete with eleethoypic grade Aluminium bus bar of size 25mm x 19 mm mounted on galvanized M. S. body power quoted pilferage proof SMC door duly welded with S.S. withrain cover size 40mm x 40mm x 5mm x 600mm height in cutting 300 mm height below groundand covered with shode proof SMC sheet of 3 mm as required. |
| 17 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\"curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 18 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps |
| 19 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm |
| 20 | Laying and fixing of one number PVC Insulated and PVC sheathed/XLPE cable of 1.1 KV grade of following size in the existing masonary open duct as required upto 35sqmm |
| 21 | S & L of following size DWCHDPE pipe ISI marked along withall accessoried like socket ,bend,couplers etc. Confirming to Is 14930, Part II complete with fittings and cutting jointing etc. Diret in ground (75 Cm below ground level) including excavation and refilling the trench but excluding sandcushioning and protective covring etc. complete as reqd. (a) 63 mm dia (OD-63mm & ID-51 mm nominal. |
| 22 | supply and fixing of 4.5 Kg CO2 fire extinguisher (wall mounting type) as per BIS specifications (conforming to IS: 2878) |
| 23 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 5/6 amps switch |
| 24 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 3 pin 5/6 A socket outlet |
| 25 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 2.5 sq. mm |
| 26 | Supplying, lowering, testing and commissioning of vertical type, multistage, totally enclosed water filled deep well submersible pumping set complete i/c connection etc. as reqd. Single Phase 3.0 HP having discharge of 100 LPM Approx. at 52 M Head |
| 27 | Supply and fixing of 3 mm thick phenolic laminated sheet |