Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 29-04-2025 | CORRIGENDUM TO DATE | Date | 06-05-2025 |
| 2 | 26-04-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 29-04-2025 |
| 3 | 21-04-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 26-04-2025 |
| 4 | 14-04-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 21-04-2025 |
| 5 | 12-04-2025 | CORIGENDUM TO TENDER | Other | 14-04-2025 |
| Sl. No. | Item Description |
| 1 | Taking out sludge including blockage and cleaning of the manhole of any size, any depth description, depth n. exc 1.50m each and removing and depositing sludge at a distance not less than 20m in a ditch including necessary excavation of pits and covering with earth & spraying unslaked lime on the covered ditch as well as around the manhole to make hygienic including necessary flushing of manhole with water after desludging, complete all as specified and directed.Note: The cost of excavation and earth work for pit, covering of ditch and providing sufficient bleaching powder shall deemed to be included in the unit quoted rate. |
| 2 | Dewatering/desludging & cleaning of septic tank of any depth, any size, taking out water minced with sludge and solid including any foreign materials such as stones, tree hedges etc, removing and depositing sludge at a distance not less than 20m in a ditch including necessary excavation of pits and covering with earth & spraying unslaked lime on the covered ditch as well as around the septic tank to make hygienic, complete all as specified and directedNote: The cost of excavation and earth work for pit, covering of ditch and providing sufficient bleaching powder shall deemed to be included in the unit quoted rate. |
| 3 | Cleaning of blockage in sewage lines/drain pipes of internal dia 100mm/150mm/200mm by rodding or by any other suitable means and cleaning the entire line and well flushing between the manholes, complete all as specified and directed. |
| 4 | Cleaning of blocked WC\"s and soil pipes of any dia up to first manhole by rodding or by any other means and well flushing with water the entire line after cleaning, complete all as directed. |
| 5 | Cleaning of blocked Floor/gully/nahani trap in bathroom/kitchen/wash basin etc and soil waste pipe of any dia upto gully traps by using rubber hand pump or rodding and opening the eye and making the line clear for smooth function, complete all as specified and directed. |
| 6 | Demolition of reinforced cement concrete of any description and in any position, disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100m, complete all as specified and directed.(Note:- Reinforcement shall be cut as required to facilitate demolition.) |
| 7 | M & L for precast RCC (1:2:4), type B-1 (using 20mm graded crushed stone aggregate) as in cover slabs (for manholes etc) and similar articles with plain faces and set in cement mortar (1:4), complete all as specified and directed. |
| 8 | S & F mild steel TMT bars 6mm to 8mm dia (Grade Fe-500D), cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia., or securing with clips, complete all as specified and directed. |
| 9 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars, manholes etc. and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100m, complete all as specified and directed. |
| 10 | M&L for brick work with sub class \"B\" bricks, old size, burnt clay bricks, straight or curved on plan exc 6 mtr mean radius built in CM (1:4), complete all as specified and directed. |
| 11 | All as per item No. 10.00 here-in-before but except bricks, complete all as specified and directed.Note - Bricks obtained from demolition shall be re-used. |
| 12 | M & L for PCC (1:2:4) type B0 (using 12.5mm graded crushed stone aggregate), cast in situ, in copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work, complete all as specified and directed. |
| 13 | Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and directed. |
| 14 | M & L for rendering 15mm thick in two coats (10mm under layer + 5mm top layer) on fair faces of brick work or concrete surfaces of wall in CM (1:4),mixed with integral water proofing compound top layer as per manufacturer\"s instructions and finished the surface even and smooth without using extra cement, complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item as supply only.) |
| 15 | M & L for rendering 15mm thick in two coats (10mm under layer + 5mm top layer) on other than fair faces of brick work or concrete surfaces of wall in CM (1:4),mixed with integral water proofing compound top layer as per manufacturer\"s instructions and finished the surface even and smooth without using extra cement, complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item as supply only.) |
| 16 | M & L for preparing newly plastered surfaces of walls and applying three coats of white wash, complete all as specified and directed. |
| 17 | Supply only liquid water proofing compound of approved quality, complete all as directed. |
| 18 | Excavation in trenches not exceeding 1.5 metre wide and not exc 1.5 metre in depth for foundation, or cable trenches etc. n. exc. 10 Sqm on plan and getting out in soft/loose soil, complete all as specified and directed. |
| 19 | Removing of excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point in any type of soil, complete all as specified and directed. |
| 20 | Returning filling in incl spreading, leveling watering and well ramming in layers not exceeding 25cm in soft/loose soil, complete all as specified and directed. |
| 21 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in PCC (1:2:4) type B1, smooth finished and reforming benching as required for 100mm bore pipe, complete all as specified and directed. |
| 22 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in PCC (1:2:4) type B1, smooth finished and reforming benching as required for 150mm bore pipe, complete all as specified and directed. |
| 23 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in PCC (1:2:4) type B1, smooth finished and reforming benching as required for 200mm bore pipe, complete all as specified and directed. |
| 24 | Demolition and breaking up 100mm bore drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar, separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100m and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100m, complete all as specified and directed. |
| 25 | All as per item No.24.00 here-in before but for 150mm bore pipe, complete all as specified and directed. |
| 26 | All as per item No.24.00 here-in before but for 200mm bore pipe, complete all as specified and directed. |
| 27 | M & L for PCC (1:3:6), type C 2, (using 40mm graded crushed stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 100mm bore pipe, complete all as specified and directed. |
| 28 | All as per item No.27.00 here-in before but for 150mm bore pipe, complete all as specified and directed. |
| 29 | All as per item No.27.00 here-in before but for 200mm bore pipe, complete all as specified and directed. |
| 30 | M & L for 100mm bore salt glazed stone ware drain pipes, grade \"A\", laid in trenches and jointed in cement mortar and tested, complete all as specified and directed. |
| 31 | M & L for 150mm bore salt glazed stone ware drain pipes, grade \"A\", laid in trenches and jointed in cement mortar and tested, complete all as specified and directed. |
| 32 | M & L for 200mm bore salt glazed stone ware drain pipes, grade \"A\", laid in trenches and jointed in cement mortar and tested, complete all as specified and directed. |
| 33 | Taking downsoil/waste vent and rain water pipes including all fittings of any size and pattern and in any position,complete all as specified and directed. |
| 34 | S & F 110mm bore PVC SWR pipe, single socketed, in any length with rubber ring joint, fixed to wall with and including clamps, complete all as specified and directed. |
| 35 | All as per item No.34.00 here-in-before but except pipes, complete all as specified and directed.(Note : Serviceable pipes obtain from taking down shall be re-used). |
| 36 | S & F 110mm bore PVC SWR pipe, single socketed, in any length with rubber ring joint, laid in trenches or floor, complete all as specified and directed. |
| 37 | S & F 75mm bore PVC SWR pipe, single socketed, in any length with rubber ring joint, fixed to wall with and including clamps, complete all as specified and directed. |
| 38 | All as per item No.37.00 here-in-before but except pipes, complete all as specified and directed.(Note : Serviceable pipes obtain from taking down shall be re-used). |
| 39 | S & F 75mm bore PVC SWR pipe, single socketed, in any length with rubber ring joint, laid in trenches or floor, complete all as specified and directed. |
| 40 | S&F 110mm bore, PVC (SWR) bends of any radius with access door, complete all as specified and directed. |
| 41 | S&F 75mm bore, PVC (SWR) bends of any radius with access door, complete all as specified and directed. |
| 42 | S & F 110mm borePVC (SWR) junction single, (single T) equal or unequal, complete all as specified and directed. |
| 43 | S & F 110mm borePVC (SWR) branch piece, single (single Y) equal or unequal, complete all as specified and directed. |
| 44 | S &F in repair 75mm bore PVC (SWR) floor trap, plain with grating including jointing to waste pipe with solvent cement, complete all as specified and as directed. |
| 45 | M&L for PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete, complete all as specified and directed. |
| 46 | M&L for PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate) as in surfaces channels and drains, complete all as specified and directed. |
| 47 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and as directed. |
| 48 | S&F framed work such as grills,gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290, Gde-E-165, complete all as specified and directed. |
| 49 | S&F framed brackets of agles or tees web and flangs cut to shape, drilled and countersunk for screw including bending and welding angles as necessary gusset plates, riveting etc. n. exc. 10 kg each brackets conforming to Fe.290, Gde-E-165, complete all as specified and directed. |
| 50 | S&F in repair galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured), complete all as specified and directed. |
| 51 | Dismantling fencing wire mesh, any type, complete all as specified and directed. |
| 52 | Supply only chain link MS galvanisd fencing, any size or type, complete all as specified and directed. |
| 53 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire, complete all as specified and directed. |
| 54 | M&L for preparation of new steel or iron surfaces of any description n. exc. 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide primer, complete all as specified and as directed. |
| 55 | Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in soft/loose soil, removing shrubs, small trees height up to 1.0 mtrs, removing the grass from route, complete all as specified and directed.Note :- Rate included removing all waste material and grass n.exc. 50 mtrs distance from installation, depositing where directed at a level n.exc. 1.5 mtrs above the starting point and cleaning of yard. |
| 56 | S & F in repair LED aviation obstraction light fixed on overhead tank heavy duty with light dependent senser, IP65/IP66 (single light) protected with all electric connection, complete all as specified and directed. |
| 57 | S & F 3 corePVC insulated unsheathed multistranded copper conductor cable (FRLSH) of size 1.5 Sqmm for connection etc, complete all as specified and directed. |
| 58 | Supply, installation, testing and commissioning factory fabricated feeder pillar (outdoor type) weather dust and vermin proof fabricated out of 3.15mm thick CRCA steel sheet outer portion AC 415 volts, 50 HZ of size 1200mm x 600mm x 300mm mounted on PCC foundation and inner portion of size 2.0mm thick suitable size of MS channel supports and and with suitable size of angle iron legs for grouting steel sheet powder coated paint internally and externally and locking arrangementincluding all incoming and outgoing connection with suitable size of lugs and glands dismantling existing unserviceable panel and including the following:-Incoming :- MCCB 200 Amp, 4 pole 36 KA, Ics = 100% Icu with thermal magnetic protection unit - 01No. Outgoing:- (i) MCCB 160 Amp, 4 pole 25 KA, Ics = 100% Icu with thermal magnetic protection unit -01 No.(ii) MCCB 63 Amp, 4 pole 25 KA, Ics = 100% Icu with thermal magnetic protection unit -02 Nos.(iii) Indication lamp for each incoming and outgoing.(iv) Digital Voltmeter -01 No.(v)Digital Ammeter -01 No.(vi) Aluminium busbar 3 phase 4 wire for rating 250 Amps for phase and neutral - 04 Nos. |
| 59 | Supply, fabricating, installation, testing and commissioning of back-lit signage boardincluding embedding the board firmly with the wall/MS angle frame/as per approved Art work and nomenclature as under :- Box with frame :- 25 x 25mm square pipe (18 gauge) frame with cross supports @ spacing not exceeding 1.0m on the box length including 20mm x 20mm MS Square pipe (18 gauge) stiffeners duly painted with two coats of white synthetic enamel paint (1st grade quality) over a coat of zinc oxide primer, depth of box should not be less than 165mm. Side, Top, Back and bottom Panels :- Made out of 24 gauge chemically treated GI Sheets duly powder coated with white matt finish coating on both inner and outer surfaces. Top panel made out of 24 gauge chemically treated GI sheet, duly powder coated, drip cap (fixed with pop rivet or machine moulded to shape) of 25mm on front and side to prevent damages due to rain etc.The bottom panel should be provided with access door fixed with stainless steel screws and suitable housing for LED drivers.LED Module :-LED 12V module beam angle >=150 degrees with IP rating >= 64, 0.72 W/70 lumens per module of 3 LEDs with 7000 to 8000 K colour temperature.LED configuration :- 29 LED modules per Sqm (equal division on spacing based on height of box) and one module every 0.20 m on running length of box.LED power supply :-Input 230 V AC, power supply should be CPCC (constant power constant current) of 30W/60W/120 W.Graphics :-Graphics shall be computer plotter cut with translucent cast vinyl matching the colour specification of the installation. |
| 60 | M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under aluminium coat and one aluminium finishing coat of paint, complete all as specified and directed. |
| 61 | S & F in repair fully automatic star delta starter,in steel sheet enclosure type with single phase preventer suitable for submersible pump motor capacity 20 HP, 415 V, 50 Hz, 3 phase, relay range 20-32 Amps, complete all as specified and directed. |
| 62 | S & F for making connection of PP-R distribution branch with PP-R main of sizes 50 to 110m by providing and fixing tee including cutting and making fusion joint etc, complete all as specified and directed. |
| 63 | Taking out from trench existing old rusted/corroded CI/DI pipe of size 100mm bore, spigot and socketed ends, including all fittings and lead joints including burning out joints and recovering lead, bailing out dirty/muddy water, if necessary, complete all as specified and directed. |
| 64 | Re-laying in trenches, jointing, commissioning & testing old serviceable CI/DI pipe of size 100mm bore with new fittings, complete all as specified and directed.(Note : Serviceable pipes obtained from taking out shall be re-used) |
| 65 | S&F stainless steel spindle of 100mm bore sluice valve including nuts, bolts, washer and rubbersheet including taking out unseviceable spindle by opening the top of sluice valve , complete all as specified and directed. |
| 66 | S&F stainless steel spindle of 80mm bore sluice valve including nuts, bolts, washer and rubbersheet including taking out unseviceable spindle by opening the top of sluice valve , complete all as specified and directed. |
| 67 | M & L for construction of valves pit chamber of size (1200mm x 1200mm x 1200mm, internal), 15cm thick PCC foundation using PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate), 25cm thick brick wall, using old size burnt clay brick in CM (1:4), 10mm thick rendering on internal and extranal surfaces both in CM (1:4), PCC (1:2:4) type B1 coping (using 20mm graded crushed stone aggregate) for grouting MS frame including foundation 3mm thick MS top sheet cover with locking arrangement including 50mm pad lock with double key arrangement, MS frame work made out of 40 x 40 x 5mm thick angle iron including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primer incuding necessary excavation in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 mtrs including demolition of existing cracked valve chamber, complete all as specified and directed. |
| 68 | All as per item No 67.00 here-in before but size (900mm x 900mm x 900mm, internal), complete all as specified and directed. |
| 69 | M & L for run lead joints in position for cast iron spigot and socket ends for pipes of size 100mm bore including spun yarn, complete all as specified and directed. |
| 70 | M & L for run lead joints in position for cast iron spigot and socket ends for pipes of size 80mm bore including spun yarn, complete all as specified and directed. |
| 71 | Detecting and repairing the water leakage in existing CI/DI pipe line laid in trenches not more than 100mm bore including necessary excavation and earth work, bailing out stagnated/muddy water, complete all as specified and directed. |
| 72 | M & L for joint with rubber or fibre board gasket of 3mm thick for flanged pipes and fittings complete with and including required no/size of nuts, bolts and washers for 80mm bore flanged pipes & fittings, complete all as specified and directed. |
| 73 | M & L for joint with rubber or fibre board gasket of 3mm thick for flanged pipes and fittings complete with and including required nos/size of nuts, bolts and washers for 100mm bore flanged pipes & fitting, complete all as specified and directed. |
| 74 | M & L for seven stage cleaning and sterlization of inside OHT reservoir capacity 25000 Gallons through bacterioligical treatment by using TERBAC G5, TERBAC-G-65 and ULTRA VOILET Ray, complete all as specified and directed. Make: Rays cleantech or equivalent as approved by GE.Process of seven stager are as under :-1. First stage is to draining out the water by using exist valve or high capacity dewatering system.2.Second stage is cleaning all the algae formation inside the tank by using TERBAC G10 a laboratory tested branded chemical of the company and scrubbing the walls of the tanks.3. Third stage is fresh water cleaning by high speed jet pump with pressure 5 PSI. 4. Fourth stage and first bacteria screening is decertification by using TERBAC-G5 a GovtLaboratory certified brannded halogen compound. 5. Fifth stage is cleaning the floor of water tank by heavy duty industrial vaccum cleaner.6. Sixth stage is the secord bacteria screening and sterilizing method by using ultra voiletray ejector covering 360 degree within the tank and kills all suspended bacteria.7. Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified, branded strong oxidizing agent TERBAC-G65Note: (i) Company will submit Govt. laboratory test certificate of TERBAC-G5, TERBAC-G65.(ii) Fixing of sticker mentioning the date of cleaning, name of site and also providing certificate confirming the completion of steriliztion of water tanks mentioning the name of station and date of cleaning. |
| 75 | S&F 8mm dia graphite gland packing including taking out unseviceable quantity, complete all as specified and directed. |
| 76 | S&F 80mm bore cast iron sluice valve in any position, double flanged complete with brass spindle, iron wheel handle clock wise closing with drilled hole, flanged, heavy duty, PN 1.6, including rubber gasket, nuts, bolts, washers including taking down old unserviceable sluice valve, complete all as specified and directed. |
| 77 | All as per item No 76.00 here-in-before but of 100mm bore, complete all as specified and directed. |
| 78 | M &L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6.3cm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized wire of size 4mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part -1, including necessary excavation and earth work, P.C.C (1:3:6) type C-1 with 50mm thick Pre-cast R.C.C. (1:2:4) type B1 cover slab (reinforced with 8mm dia deformed bar 15cm C/C both ways and suitable handle of 10mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15cm compacted thickness all around the earth electrode, with funnel and 20mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, Gl earth wire protected by 15mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion including dismantling of old unserviceable earthing of any descriprtion, complete all as specified and as directed.Note : Proper earthing pit shall be provided with pit cover. |
| 79 | All as per item No 78.00 here-in-before but using galvanised iron strip 32 x 6mm as earth lead, complete all as specified and directed. |
| 80 | S&F in repair PVC insulated FR, PVC sheathed, stranded, flat submersible copper conductor cable, of size 10 Sqmm 3 core, 1100 volts grade, complete all as specified and directed. |
| 81 | M&L for flushing bore well at the site with air compressor of capacity 250PSI/1000 Cum and related accessories at least 60 hours till water discharge is free from sand and potable water and to achieve maximum discharge capacity, complete all as specified and directed.Note: Unit rate quoted shall deemed to be inclusive of necessary tools and equipments, as required at site of work, and removing the same after completion of work. |
| 82 | S&F power pack, industrial type, 180 AH, 12 volt, 25 plate alongwith copper lead and clamp, complete all as specified and as directed. |
| 83 | S&F in repair CPVC ball valve of size 50mm dia, suitable for CPVC pipe including necessary fittings, complete all as specified and as directed. |
| 84 | S&F in repair CPVC pipe of size 50mm dia, in trenches, high pressure CPVC pipes SDR-11 & plain CPVC SDR 11 fittings includingall necessay fittings, solvents cement, complete all as specified and as directed. |
| 85 | S&F mild steel column pipe 80mm bore heavy duty having wall thickness 5.4mm (3.0m/1.524m long) both end threaded with one socket conforming to IS-1239 (part-I), 1979 including painting with two coats of black bitumenous paint over a coat of red oxide zinc chrome primer internally and externaly (suitable for drinking purpose) including taking out old unserviceabe column pipe and deposited to AGE E/M store yard, complete all as specified and directed. |
| 86 | S&F post top lantern LED type 40 watt, outdoor type with decorative post top for 360 degree indirect light, IP 65/IP 66 protection with impact and corrosion resistant complete withdriver and lamp, complete all as specified and directed. |
| 87 | S&F MCB distribution board (DB), SPN with sheet metal encloser, double door, IP 43 protection, 240 volts, 08 way, with 200 Amps rated busbar (as per OEM), neutral link for fixing MCBs/Isolators including taking down old unserviceable MCB DB of any description, completes all as specified and directed. |
| 88 | S&F MCB Single Pole (SP) of capacity 6 to 32 Amps, 240 Volts, breaking capacity 10 KA, ‘B’ series, fixedin proper position, complete all as specified and directed. |
| 89 | S&F in repair MCB Single Pole Neutral (SPN) of capacity 6 to 32 Amps, 240 Volts, breaking capacity 10 KA, ‘B’ series, fixedin proper position, complete all as specified and directed. |
| 90 | S&F in replacement offirst aid kit box/emergency medical boxwall mouted type made out of powder coated GI sheet of 18 gauge and the size of the box will be 36cm(H) x 26cm(W) x 13 cm(D) with front transparent acrylic glass and multi compartment 4 shelf for better organize of medicines with security lock on door, openable window at front side with help of hinge at one side and locking arrangement at another side, openable window must painted with \"FIRST AID\" with red paint and whole box will fixed on wall at height not less than 2mtr including medicene and other items as under :- Sterilized dressings(04), Cotton Wool 10 gm (02), Antiseptic Solution 100 ml (01), Burn Ointment (01), Scissor (01), Digital Thermometer (01), Disposal Gloves(02), Disposal Mask (20), Adhesive / Microporous Tape 1/2\" (01), Band- Aid (10), safety pins(05), Sofraxime Cream (01), Cold Rub(01), Roller Bandage 5 cm (02), Roller Bandage 10 cm (02), cotton Buds (10), First-Aid Guide booklet, Hand Sanitizer (02), Handiplast (12), Antiseptic cream (01), Antiallergic medicene, Cough medicene, Pain killer, Fever and cold medicene and any other essential medicene, complete all as specified and directed. |
| 91 | Supply and laying double walled corrugated (DWC) HDPE duct pipe of 20mminner dia, conformingto IS, approved colour complete with fittings for cable protection, complete all as specified and directed. |
| 92 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size16 sqmm 4 core including taking down old unserviceable UG cable, complete all as specified and directed. |
| 93 | Note: An amount of Rs.44,770.00 on account of Credit Schedule for schedule \"A\" part - II shall be deducted from the total amount of BOQ to arrive at the contract sum. |
| 94 | Supply and fixing energy efficient ‘LED Flood Light120 W LED luminairewith Aluminium dia cast housing, toughened glass cover with IP 66 protection, CCT 5700 K including fixing arrangment on wall/pole / surface and connecting cable up to nearest ceilign rose into flexible PVC conduit. Make : Crompton/Havells/ Surya/Philips |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail