| 1 | Provn of parking shed and pathway near orchid billet at AFS KurseongExcavation in post holes or similar holes each n.exc 0.50 cum, getting out, returning, filling in and ramming earth around in layers n.exc 25 cm, watering and removed surplus soil to a distance n.exc 50 m and making good surface in soft/loose soil complete all as specified and directed. |
| 2 | M&L for cement concrete, (1:3:6), type C-2 (using 40 mm graded stone aggregate) in foundation filling and mass concrete complete all as specified and directed. |
| 3 | M&L for MS steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS: 1161-1979 grade St.-240 complete all as specified and directed. |
| 4 | M&L for plates (plain or chequered square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed. |
| 5 | M&L for bands, straps, supports or stays for rainwater, ventilating pipes including bolts, if required hooks (stay) heavy for large gates, hook and pintle hinges large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts two way and three way straps, plate washers and similar small articles to Fe-290 Gde-E-165 complete all as specified and directed. |
| 6 | M&L for preparation of new steel surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 7 | M&L for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 8 | M&L for pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed. |
| 9 | Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in hard/dense soil etc. complete all as specified and directed. |
| 10 | M&L for hard core using broken stone or boulders n.exc 63 mm, deposited, spread and levelled in layers n.exc 15 cm thick, watered and rolled/ rammed to a true surface complete all as specified and directed. |
| 11 | M&L for 75mm thick PCC, 1:4:8, type D2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed. |
| 12 | M&L for interlocking tile, machine pressed precast paver block, any shape and size conforming to IS: 15628-2006 of 60 mm thickness M-35 grade with grey cement and pigment complete all as specified and directed. |
| 13 | M&L for sand filling under floors or in cushioning for paver block including watering and consolidation complete all as specified and directed. |
| 14 | M&L for PCC, 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in copings including weathering, slightly rounded and chamfered complete all as specified and directed. |
| 15 | Removing excavated soil to a distance exc 250 m but n.exc 500 m and depositing where directed complete all as specified and directed. |
| 16 | Provn of washroom at detention cell and associated works at AFS KurseongExcavating in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth; for foundation etc. or for shafts, wells, cess pits, manholes, pier holes etc. n.exc 10 sqm on plan and n.exc 1.5 m in depth and getting out in hard/ dense soil complete all as specified and directed. |
| 17 | M&L for cement concrete, 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete etc. complete all as specified and directed. |
| 18 | M&L for brick work old size with subclass \"B\" bricks straight or curved on plan n.exc 6 m mean radius built in CM 1:6 complete all as specified and directed. |
| 19 | M&L for 15 mm thick cement plastering on brick/ concrete surfaces in CM (1:4) finishing surfaces even and fair without using extra cement complete all as specified and directed. |
| 20 | M&L for 10 mm thick cement plastering on brick/ concrete surfaces in CM (1:6) finishing surfaces even and fair without using extra cement complete all as specified and directed. |
| 21 | M&L for RCC, 1:2:4, nominal mix, type B-1 (using 20 mm stone aggregate) as in lintel band including formwork complete all as specified and directed. |
| 22 | M&L for TMT bars 10 mm mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 23 | All as item No. 22.00 above, but of 5mm dia and over upto and including 10mm dia in strrups, spacers and binder. |
| 24 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed. |
| 25 | M&L for removing excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed. |
| 26 | M&L for 20 mm thick damp proof course to horizontal or vertical surfaces including necessary formwork in CM 1:2 complete all as specified and directed. |
| 27 | Spreading levelling in layers n.exc 25 cm thick and well ramming including watering complete all as specified and directed. |
| 28 | M&L for 75 mm thick plain cement concrete, 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub base of floor etc complete all as specified and directed. |
| 29 | M&L for 40 mm thick plain cement concrete, 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in floor finished even and fair without using extra cement complete all as specified and directed. |
| 30 | M&L for hard core of broken stone boulders gauge n.exc 63 mm deposited, spread and levelled in layers n.exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 31 | M&L for screed bed of mortar 20 mm thick for laying floor finishes in CM 1:4 complete all as specified and directed. |
| 32 | M&L for non-skid ceramic tile 7 to 8 mm thick area of each tile exc 0.17 sqm but n.exc 0.38 sqm in floors etc set and jointed in neat cement slurry and pointed in white cement to match complete all as specified and directed. |
| 33 | M&L for glazed ceramic coloured tile in vertical surfaces of size 450x350x7mm/ 350x250x7mm thick set and jointedneat cement slurry incl pointed in white or colour cement to match and including 12 mm thick backing coat in 1:4 complete all as specified and directed. |
| 34 | M&L for preparing newly plastered surface of wall and applying two coats of oil bound distemper over one coat primer on walls complete all as specified and directed. |
| 35 | M&L for preparation of newly plastered or unplastered surface on wall surface and applying two coats of cement base paint complete all as specified and directed. |
| 36 | M&L for solid PVC door frame of size 50mm x 95mm made out of 5 mm wood grain printed PVC sheet reinforced with M.S. square tube, supplying & fixing in opening as per specification & drawing complete all as specified and directed. |
| 37 | M&L for factory made solid PVC moulded door shutters 28 to 30 mm thick (stiles) with 2, 4 or 6 raised panel design with 2 mm thick 3D wood grain moulded PVC sheet polyurethane painted on the front face & 2 mm prelam PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed. |
| 38 | M&L for mild steel works as in bands straps, hold fasts etc conforming to IS: 2062-2006 (Fe-290), embedded portion duly painted with bituminious paint and sanded complete all as specified and directed. |
| 39 | S&F mild steel butt hinge medium weight, cold rolled, 100 mm, ISI marked complete all as specified and directed. |
| 40 | M&L for barrel tower bolts stove enamelled black of size 150 mm complete all as specified and directed. |
| 41 | S&F 150 mm long aluminium anodised handle or extruded section complete all as specified and directed. |
| 42 | M&L for 300 mm long aluninium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded sections or cast-aluminium alloy complete all as specified and directed. |
| 43 | M&L for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as specified and directed. |
| 44 | M&L for Fe-410W (Gde-E-250) quality B rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails fixed with angle cleats or other connecting plates complete all as specified and directed. |
| 45 | M&L for two coats of painting with synthetic enamel paint (ordinary tint), over one coat of red oxide, zinc chrome primer on steel and iron surface of any description over 10 cm in width or girth, not otherwise described including preparation of new surface complete all as specified and directed. |
| 46 | M&L for 15 mm bore unplasticised PVC pipe of pressure rating 10 kgf/Sq cm fixed to wall or ceiling or laid in floors incl fittings etc complete all as specified and directed. |
| 47 | M&L for 20 mm bore unplasticised PVC pipe of pressure rating 10 kgf/Sq cm fixed to wall or ceiling or laid in floors incl fittings etc complete all as specified and directed. |
| 48 | S&F 75 mm bore PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed. |
| 49 | M&L for 75 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed. |
| 50 | M&L for grating doom 100 mm dia of PTMT (minimum weight 25 gms) complete all as specified and directed. |
| 51 | S&F in repair, 20 mm bore gun-metal, globe or gate valve with iron wheel head, screwed both end for iron pipe and fixed complete all as specified and directed. |
| 52 | S&F 600mm x 450mm bevelled edge mirror or selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 53 | S&F in repair, brass chromium plated tubular towel rail, 20 mm dia, \"D\" type, 60 cm long between flanges complete all as specified and directed. |
| 54 | S&F in repair, vitreous china wash basin, white, flat back, size 630x450 mm excluding taps, waste chain and plug and porcelain stopper but including brackets, waste coupling, waste pipe complete all as specified and directed. |
| 55 | S&F in repair, soap dish, vitreous china white, approximate size 160x60x90 mm fixed to plug with CP brass screw complete all as specified and directed. |
| 56 | S&F in repair, 15 mm dia pillar tap, cast copper alloy, with capstan heads, chromium plated fancy type, screwed down high pressure, with or without lettered \"Hot\" or \"Cold\" with long shanks and flynuts, screwed for iron pipe complete all as specified and directed. |
| 57 | M&L for coloured EWC pedestal pattern with plastic seat cover & PVC flushing cistern including gst complete set with \"S\" or \"P\" trap complete all as specified and directed. |
| 58 | M&L for CP brass health faucet (jet spray) fixed along with PVC flexible connection and wall hook including gst complete all as specified and directed. |
| 59 | M&L for anodised aluminium snap grid size of 605 x 605 mm frame work for false ceiling all as specified and Gl frame work for seamless ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx. 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (n.exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. M&L for 12 mm thick seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finishing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish Note: Frame work for ceiling shall be measured and paid separately. |
| 60 | S&F in repair, rotational moulded polyethylene water storage tank,1000 litres capacity, ISI marked, multi layer constriction (cylindrical vertical with closed top), hoisted & fixedin position including all fittings and fixtures complete all as specified and directed. |
| 61 | Provn of office partition at 322 TRU and 799 SU AFS KurseongM&L for powder coated aluminium frame (minimum thickness of powder coated 50 micron) for doors and windows ventilators with one or more rebates including joints cleats for fixing etc complete all as specified and directed. |
| 62 | M&L for sheet glass, 5.5 mm thick, ordinary quality and glazing with rubber beading, cleats in necessary to aluminium door/ windows etc area exc 0.5 sqm in each pane complete all as specified and directed. |
| 63 | M&L in repair, 18/19 mm thick prelaminated board exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screw to timber frame including taking down existing board of any description complete all as specified and directed. |
| 64 | Provn of wall panelling at IT cell at AFS KurseongM&L for solid wall lining consisting 5 mm thick wood grain printed sheet including of solvent cement and fixing at site on PVC frame as per specification complete all as specified and directed. |
| 65 | Provn of iron gate and staircase at AFS KurseongExcavation in post hole or similar holes each n.exc 0.50 cum, getting out, returning filling in and ramming earth around in layers n.exc 25 cm, watering and removed surplus soil to a distance n.exc 50 m and making good surface in soft/loose soil complete all as specified and directed. |
| 66 | M&L for cement concrete, (1:3:6), type C-2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 67 | M&L for 1 mm thick mild steel, plain black sheet in wall cladding, steel gates and similar work, cut to size, hole punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams including bending or turning up, mitred angles etc as required complete all as specified and directed. |
| 68 | M&L for framed work such as grills, gratings etc with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290 Gde-E-165 complete all as specified and directed. |
| 69 | M&L for two coats of painting with synthetic enamel paint (ordinary tint), over one coat of red oxide, zinc chrome primer on steel and iron surface of any description, over 10cm in width or girth, not otherwise described including preparation of new surfaces complete all as specified and directed. |
| 70 | Provn of alarm bell at guard posts at AFS KurseongSupply, laying and testing of PVC armoured, electric power cables (heavy duty) 1100 Volts grade with copper conductor of size 1.5 sqmm 2 core complete all as specified and directed. |
| 71 | Excavation in trenches n.exc 1.5 m in wide and n.exc 1.5 m in depth for taking out or laying of under ground cable in soft/ loose soil complete all as specified and directed. |
| 72 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick in soil complete all as specified and directed. |
| 73 | Removing surplus soil to a distance n.exc 50 m and deposited at a level n.exc 1.5 m above the starting point complete all as specified and directed. |
| 74 | M&L for HDPE double wall corrugated duct pipe of size 40 mm OD and 32 mm ID for cable protection laid in trenches complete all as specified and directed. |
| 75 | S&F ceiling rose surface backlite 3 terminals 65x50mm 230 V including PVC box of size 3\" x 3\" round type complete all as specified and directed. |
| 76 | S&F bell push, 5 Amp, 230 Volt complete all as specified and directed. |
| 77 | S&F bell electric ding dong type, AC, 230 V complete all as specified and directed. |
| 78 | Provn of external electric supply to porta cabin at AFS KurseongExcavation in trenches n.exc 1.5 m in wide and n.exc 1.5 m in depth for taking out or laying of under ground cable/ pole in hard dense soil complete all as specified and directed. |
| 79 | Returning, filling in including spreading, levelling, watering and well ramming in layers, n.exc 25 cm thick in soil complete all as specified and directed. |
| 80 | Removing surplus soil to a distance n.exc 50 m and deposited at a level n.exc 1.5 m above the starting point complete all as specified and directed. |
| 81 | M&L for HDPE double wall corrugated duct pipe of size 40 mm OD and 32 mm ID for cable protection laid in trenches complete all as specified and directed. |
| 82 | M&L for cutting the existing road/ PCC/ drain for taking out/ laying of underground cable including necessary earthwork excavation and making good to match with the existing surface complete all as specified and with the 100mm thick PCC, 1:3:6, type C-1 (by using 20 mm graded stone aggregate) complete all as specified and directed. |
| 83 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 4 core complete all as specified and directed. |
| 84 | SR/ Rep of BER geysers at AFS KurseongS&F in replacement of AC single phase, 230 volts electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc including connection with multistranded copper conductor flexible wire of suitable size from DB, necessary fixing arrangement i.e anchor nut, bolt, washer, PVC pipe connection and grouting and making good to distrubed surface complete all as specified and directed. |
| 85 | M&L in replacment of sub main wiring with 2 runs of 4 Sqmm PVC insulated unshehathed copper cable multistrand 1100 V of FRLSH grade with drawn in and including surface PVC casing caping with not less than 25 mm and one run of PVC insulated serviceable of 4 Sqmm as earth continuity coductor drawn in casing and caping with accessories complete all as specified and directed.Note: 3 runs of 4 Sqmm and 1 run of casing caping will be measured as one unit i.e. RM. |
| 86 | S&F in replacement of factory made sheet metal enclosure with protected type 2 pin and earth plug and complete socket with one MCB SPN 240 V, 20 Amps complete all as specified and directed. |
| 87 | S&F in replacement of swich piano flush type single pole, one way, 16 Amp along with PVC box and all other accessories required for fixing complete all as specified and directed. |
| 88 | NOTES :-1.The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. |