Tender For Construction Of Toilet Block At Jepla Chhabra. - Earth work in surface excavation not exceeding 30cm. in depth but exceeding 1.5 meter in width as well as10 Sqm on plan including disposal of excavated earth up to 50 Mtr. and lift up to 1.5 Mtr. disposed soil to be levelled and neatly dressed: All kinds of soil Herbarium Toilet 3 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sum on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter.All kinds of soils 4 Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. 5 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size). 6 Supplying chemical emulsionin sealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable concentrate of 20% Herbarium Toilet 7 Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion) 8 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 9 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix 10 Random rubble dry stone Kharanja under floor. 11 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). 12 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand). 13 Brick work with common burnt clay F.P.S.(Non Modular) bricks of class designation 7.5 in superstructure above plinth level upto floor five level in all shapes and sizes in : Cement mortar 1 : 6 (1 cement : 6 coarse sand) 14 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for : Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 15 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix 16 Half brick masonry with common burnt clay F.P.S.(Non Modular) bricks of class designation 7.5 in Superstructure , above plinth level upto floor fivelevel. Cement mortar 1 : 4 (1 cement : 4 coarse sand) 17 Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish : 20mm thick . 18 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) 19 Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth completeNew Plastered Surface (three or more coats) 20 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: New work(Two or more coats)including prepartion of base with primer, putty, lippy etc complete in all respect. 21 Finishing walls with textured exterior paint of required shade as per approved colour complete as per manufacturers specificationsincluding primer coat and protecting coat 22 Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 23 Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 24 Providing and fixing factory made of uPVC Extruded section having an overall dimension as below (tolerance+/-1mm) with wall thickness 2.0mm+/-0.2mm,corners of the door frame to be mitred and welded of plastic ,galvanized brackets and stain less steel screws.The hinge side vertical of the frames reinforced by galvanized M.S.tube of size 19x19mm and 1mm+/-0.1mm wall thickness and 3 nos.stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-in-charge. 25 Providing and fixing to existing door frames 30mm thick factory made polyvinyl chloride (PVC) door shutter made of stiles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2mm +/- 0.2mm with inbuiltdecorative moulding edging on one side. The stiles and rails mitred and joined and the corners by means of M.S.galvanized/plastic brackets of size 75x220 mm having wall thickness 1.0mmand stainless steel screws. The stiles of the shutter reinforced by inserting galvanized M.S.tube of size 25x20 mm and 1mm +/- 0.1mm wall thickness. The lock rail made up of ‘H’ section, a uPVC hollow section of size 100x30 mm and 2mm +/- 0.2mm wall thickness fixed to the shutter stiles by means of plastic/galvanized M.S.tube ‘U’ cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 610mm,having overall thickness of 20mm and 1mm+/- 0.1mm wall thickness.The panels filled vertically and tie bar at two places by inserting horizontally 6mm galvanized M.S.rod and fastened with nuts and washers.complete as per manufacturer’s specification and direction of Engineer-in-charge.(For W.C.and bathroom door shutter) 26 Providing and fixing of UPVC casement openable windows (outward / inward): Outer Frame made from the Extruded UPVC Windows profile section of size 60w X 60h mm having outer wall thickness of 2.5mm (+/- 0.2mm) and three chamber constuction, White in finish, duly reinforced with 1.5mm thick GI section. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side. Fix Mullion made of 60w X 80h mm UPVC profile section with steel reinforcement shall be provided in windows having 2 or more openable shutters, as per the requirement. Frame shall have co-extruded with EPDM/TPE-E gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. Shutter:The shutter of outward openable window shall be made of size 60w X 74h mm and shutter of inward openable window shall be made of size 60w x 77h mm Extruded 3 box multi-chamber UPVC Window profile section of white colour having outer wall thickness of 2.25mm (+/- 0.2mm) provided with reinforcement of 1.5mm thick GI section duly mitered cut & thermal welded at all corners and fitted with UPVC glazing bead of size 36 X 20mm with inner and outer co-extruded EPDM/TPE-E weather seal gasket alongwith 6mm thick ISI make plain float glass. All welding joints of frame and shutter shall be cleaned and milled with the CNC mechainism to provide uniform grooved finish on all visible jaints. Hardware: Window shutter are fixed with frame on 2.5mm thick SS301 Grade friction hinge system to keep the window opened at desired angle. Friction Hinge also enables easy cleaning of glass on both side from the inside of building. 27 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. Thermo-mechanically Treated bars (Conforming of relevent IS code) 28 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting offollowing operations. (a) Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with proprietary water proofing compound conforming to IS. 2645 over the RCC slab including cleaning the surface before treatment. (b) Laying cement concrete using broken bricks/brick bats 25 mm to 100mm size with 50% of cement mortar 1:4 (1 cement : 4 coarse sand) admixed with proprietary water proofing compound conforming to IS : 2645 over 20 mm thick layer of cement mortar of mix 1:4(1 cement :4 coarse sand )admixed with proprietary water proofing compound conforming to IS : 2645 to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry admixed with proprietary water proofing compound conforming to IS : 2645. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix1:4 (1 cement :4 coarse sand) admixed with proprietary water proofing compound conforming to IS : 2645and finally finishing the surface with trowel with neat cement slurry and making of 300x300xmm square (e)The whole terrace so finished shall be flooded with water fora minimum period of two weeks for curing and for final test.All above operations to be done in order and as directed and specified by the Engineer-in-Charge.With average thickness of 120mm and minimumthickness at khurra as65 mm. 29 Providing & laying broken glazed titles on roof ( broken glazed tilesnot less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg ofVG-40 (30/40 )grade and 0.30 Kg/Sqm. OfVG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. 30 Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. 31 Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete 32 Short point (up to 3 mtr.) 33 Medium point (up to 6 mtr.) 34 Long point(up to 10 mtr.) 35 On board 36 20 mm 37 25 mm 38 40 mm 39 3x 1.5 sq.mm 40 2 x 2.5 sq. mm. + 1x1.5sqmm 41 2 pair 42 10 pair 43 6 A to 32 A rating 44 30 A / 40 A rating 45 16 A 3 pin(2P+E) 46 6/16 Ashuttered socket 47 1-2 Module 48 1/2 Module 49 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 50 Up to 457 mm size 51 300 mm sweep(900/1400 RPM) 52 Minimum lumen output 1950 lm 53 1170mm(+/-10%) LED batten with min. lumen output 2200 lm 54 9 Watt 55 Providing & Fixing of ISI marked (IS:1258) batten/angle lampholder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 56 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR 57 P & F water closet Seat Covers with brass hinges complete :Solid PVC (ISI marked) grade-I White for EWC. 58 P & F European type white glazed vitreous china 1st quality W.C pan (IS : 2556 Mark) with P or S trap including cutting and making good the wall and floor 59 P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make 32 mmwaste pipe complete including cutting & making good the wall :460 dia for counter top 60 P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make (Atul, Modi Guard, Saint Gobin or equivalent) complete with 6mm thick commercial ply base fixed to wooden screws & washers.Size 600 x 450mm x 4 mm thick 61 P & F Towel Rail or Ring of approved quality/make: C.P. brass towel rail withbrackets 600 x 20mm. 62 P & F Grating of approved quality/make: Stainless Steel Grating125 mm Nominal dia 63 Providing and fixingliquid soap container 109 mm wide, 125 mmhigh and 112 mm distance from wall of standard shape withracket of the same materials with snap fittings of approved quality and colour,weighing not less than 105 gms.PTMTliquid soap Container of 400ml capacity 64 P & F Soap Dish or Tray of approved quality/make C.P. brass 65 P & F Jet spray for water closet with C.P. Copper Tube flange of approved make. 66 20mm nominal outer dia pipes (Internal work Exposed on wall) 67 32mm nominal outer dia pipes (Internal work Exposed on wall) 68 20mm nominal outer dia pipes (External work). 69 32mm nominal outer dia pipes (External work). 70 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.(Concealed work including cutting chases and making good the walls etc.,)20mm nominal outer dia pipes 71 P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: C. P. Brassbib cock, 15mm nominal bore 72 P & F Stop Cock(IS :8931 Mark),superior quality & ofapproved make:Brass 400 gm. 15mm nominal bore. 73 P & F Ball Cock (IS :1703 Mark) with Rod& P.V.C. Ball complete :Brass wt. Not less than 300 gm,15mm. 74 P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc.C.P. Inlet connection 15mm.Brass (IS : 8931 marked) 75 Gun-metal 15mm nominal bore. 76 Gun-metal 25mm nominal bore. 77 P & F Gun-metal Non-return Valve or Check Valve (IS :Make) of approved make, superior quality:50mm nominal bore. Horizontal 78 P & F PVC Storage Tank (IS:12701 marked indicating the BIS license No.) of approved make with cover, 25 mm dia 1 M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including placing on terrace( at all floors),making connection etc. complete of approved design. 1000 litres capacity 79 Construction of chamber in all type of soil with 230/300 mm thick masonry in CM 1:6 m 10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr. Inside size 450 x 450mm depth upto0.5 M Cement cover with frame 80 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes.Type A 75 mm dia 81 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes.Type A 110 mm dia 82 75mm dia Coupler 83 110mm dia Coupler 84 Single Bend w/o Door 87.5° 75mm dia 85 Single Bend w/o Door 87.5° 110mm dia 86 Single Bend with Door 87.5° 110mm dia 87 Single Y without Door 110mm dia 88 Single Pushfit Coupler 75mm dia 89 Single Pushfit Coupler 110mm dia 90 Pipe Clip75mm dia 91 Pipe Clip110mm dia 92 Nahni Trap100 x 75 mm with CP Jali 110mm dia 93 Vent Cowel 110mm dia 94 P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete.WVC Flat Back half stall Urinal size 580x380x350 mm/ Angle back 450x375x350 type liped front.. 95 Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.: Size 240 Cm. dia outside & 240 Cm. depth. 96 Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M- 15 grade C.C floor & RCC slab covering with M15 grade c.c. floor, 50 mm thick stone slab partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos stone foot rests of approved design ,two No. 450 mm dia each Ferro cement cover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:-Size 200x100x130 cm.(for 10 users) with 115 mm thick RCC(M-20) slab with Tor steel reinforcement 8mm ϕ @15 cm c/c bothways including shuttering complete in all respect.