Tender For Annual Maintenance Contract Of Mini Mast High Mast - OD227896/2023-2024:Labour charges for dismantling the existing100w/120w/150/200w LED floodlight fitting from the Minimast,opening,cleaning,checking the connections, repairing and refitting the same on existing Minimast and giving connection including all charges. 3 90.15.4.7:Supply Conveyance, installation, testing and commissioningof100WLEDFloodlightoutputgreaterthan 105lumen/W4000-6000Kwith IP66protectionLEDChip makeCree/Lumilled/Nicheawithpowerfactorgreaterthan 0.95at full load, internal surgeprotectionupto8KV,and Aluminiumpressuredie-castPowdercoatedhousing,acrylic cover completewith THD less than 10%, power factor greaterthan0.98,RoHScompliant,dulywiredupforuseon 230VACsupply.Drivercompartmentshouldbeseperatly accessible for maintenance (LM79&80 certificates fromNABL accredited Third party lab to be produced mentioning chip manufacturer) 4 90.15.4.11:Supply Conveyance, installation, testing and commissioningof200WLEDFloodlightoutputgreaterthan 105lumen/W4000-6000Kwith IP66protectionLEDChip makeCree/Lumilled/Nicheawithpowerfactorgreaterthan 0.95at full load, internal surgeprotectionupto8KV,and Aluminiumpressuredie-castPowdercoatedhousing,acrylic cover completewith THD less than 10%, power factor greaterthan0.98,RoHScompliant,dulywiredupforuseon 230VACsupply.Drivercompartmentshouldbeseperatly accessible for maintenance (LM79&80 certificates fromNABL accredited Third party lab to be produced mentioning chip manufacturer) 5 OD232095/2023-2024:Supplyingandrenewingthedefective LEDdrivewithnewLEDdrivesuitablefor100wLEDFlood light fittingetc. completeandgivingnecessaryconnection including all charges. 6 OD232097/2023-2024:Supplyingandrenewingthedefective LEDPCBwithnewLEDPCBsuitablefor100wLEDFloodlight fitting etc. complete and giving necessary connection including all charges. 7 2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415volts,Ccurve,miniaturecircuitbreakersuitablefor inductive loadof followingpoles in theexistingMCBDB completewithconnections, testingandcommissioningetc. as required. Single pole 8 2.12.1:Supplyingand fixing following rating, doublepole, 240volts, isolator in theexistingMCBDBcompletewith connections, testingandcommissioningetc.asrequired.40 amps 9 2.14.1:Supplyingand fixing following rating, doublepole, (singlephaseandneutral),240volts,residualcurrentcircuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testingandcommissioningetc.asrequired.25 amps 10 OD227898/2023-2024:Supplyingand fixing32A2PoleAC1 Power contractor in the existing MCB DB/enclosure complete with connections, testing and commissioning etc.as required. 11 OD227899/2023-2024:SupplyingandFixing24Hour timer for operating ON-OFF function in the existing MCB DB/enclosurewithconnectiontestingcommissioningetcas required. 12 OD227900/2023-2024:SupplyandFixing32AFusebaseand fuselink intheexistingpanelboardandgivingconnection including all labour charges. 13 OD227901/2023-2024:Supplying and fixing 32 A, 2Way neutral linksmountedonDMC/SMCbasewithconnections, in existing meter board. 14 OD227891/2023-2024:Carryingoutcontrolwiringforpanel withnormalmetersandindication lampsalonewith650/ 1100VgradePVC insulatedstrandedsingle corecopper conductor cables conforming to IS 694 part I 1990 for interconnecting the control devices/equipments including providingsuitablesizeinsulatedsocketsatthetermination pointsor solderedproperly,providingnumbering ferrules for the proper identification of thewiring, keeping the wiring firmby suitable tie/tiemounts/PVC duct etc as required.1.50 sq mm single run with required sockets. 15 90.12.7.2:Supply,layingandclampingof1no.PVCinsulated andPVCsheathedarmouredaluminiumpowercable,1.1KV gradeof thefollowingsizesusingclampsnotedalongwith thecables,spacingofclampsnotexceeding60cms,making goodthedamages,colourwashingetc.asrequired.2core6 sq mm with factory made clamp 16 90.12.7.39:Supply, laying and clamping of 1 no. PVC insulatedandPVC sheathedarmouredaluminiumpower cable,1.1KVgradeofthefollowingsizesusingclampsnoted alongwith the cables, spacing of clamps not exceeding 60cms,makinggoodthedamages , colourwashingetc.as required.4 core 6 sq mm with factory made clamp 17 90.12.5.2:Supply&layingofonenumberPVCinsulated andPVC sheathed armoured aluminiumpower cableof 1.1KV grade of the following sizes in the existing RCC/ HUME/STONEWARE/GI/DWCpipeasrequired.2core6sq 18 90.12.5.39:Supply & laying of one number PVC insulatedandPVC sheathedarmouredaluminiumpower cableof1.1KVgradeof thefollowingsizes intheexisting RCC/HUME/STONEWARE/GI/DWCpipeas required.4 core 6 sq mm 19 9.1.1:Supplying andmaking end terminationwith brass compressionglandandaluminiumlugsforfollowingsizeof PVC insulated and PVC sheathed / XLPE aluminium conductorcableof1.1KVgradeasrequired.2X6sq.mm (19mm) 20 OD227915/2023-2024:Supplying and making end terminationwithbrass compressionglandandaluminium lugsforfollowingsizeofPVCinsulatedandPVCsheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. 4 x 6 sq. mm (19mm) 21 90.6.5.12:SupplyanddrawingthefollowingsizesofmulticorePVCinsulated&FRLS PVCsheathed650/1100V gradecopperconductorroundflexiblecablesconformingto IS694partI1960intheexistingsurface/recessconduitas required including giving necessary connections of the following sizes.3 core 2.50 sq mm 22 90.14.1.1:Fabrication, supply, conveyance, installation testing and commissioning of floor or wallmounting,dust and vermin proof,cubicle type MV panel board comprising of the following components/ devices & amp;complying to IS8623.<br> Fabrication of fully partitioned,dustand vermin proofen closure for panel assembly as per form 4 of IS8623 (withlatestamendments)using CRCA sheet as per approved design and requirement, with front and rearaccessfacility,busbarchambers,hingeddoorsforallswitch gear compartments, earthing the doors using 4 sqmm braidedcopperconductor,providingnecessarycut-outsformounting meters, relays, indication lamps, bus barinterconnectionetc,detachablecoversforbusbarchamberand cable alley, powder coating the assembly aftersubjecting to7tankprocessetcas required. CRCAsheetalonebeused for the fabrication. Angles/ flats/ slotted angles etc shall notbeused for the fabricationof panelassembly. Themeasurmentswill betakentheareaofthecompletesheetsusedforpanelboardincludingpartitions,folding,shroudingetc.SupplyandfabricationofMVpanelboardusing2.00mmCRCAsheet,powdercoated(excluding base frame) 23 90.14.3.1:Supply and providing heavy duty A section neoprene gasket in the panel boardA section neoprene beeding suitable for 1.60/ 2.00 mm sheet