| 1 | Providing day to daymaintenance of Electrical and electromechanical services installed in telecom premises to ensure minimum breakdown, by arranging/ deployingTWO un-skilled, ONE semi-skilled Man-powers in general shift (for 26 days) for checking of system, cleaning and restructuring of MV panels, feeder Pillers along with switch gears,minor testing checking and connection/disconnection, preventive maintenance of AVR, AFD panel,Pump Set, DG set etc, Cleaningwith blower, greasing of moving contacts and terminals, testing of system wherever required. The work includes restoration of all kinds electrical breakdown at LT end ofTE/BTS/Quarters, checking of faults in the system, replacing faulty spare parts/fittings/appliances, checking ofinsulation by meggering with insulation tester, checking of earth resistance by Earth tester, checking AC/DC voltage, AC/DC current, frequency using Clamp Meter, counting/measuring of Electrical items/appliances at all the Telecom buildings and submit report to Engineer In charge to prepare inventories, Arranging to restore the systemwith the available resource & materialetc as reqd etc and any kind of work as instructed by the Engineer in charge [The cost of materials shall be measured separately as per the direction of Engineer in charge)] [The manpower will be responsible for traveling throughout the state of Tripura whenever required, as per the instructions of the Engineer-in-Charge. Accordingly, the cost of journey/transportation will be calculated.] |
| 2 | Fault rectification including transportation charge/ vehicle fairto the various exchange /BTS sitesfor skilled mechanic & helperalong with necessary tools and plants for the following distance category of site.(No of site taken approximatefor attending any breakdown work or preventive maintenance as per the direction of Engineer in charge, The cost of materials shall be measured separately as per actual requirement) |
| 3 | 8 to 10 Km |
| 4 | 10 to 25 Km |
| 5 | 25 to 50 Km |
| 6 | 50 to 75 Km |
| 7 | 50 to 100 Km |
| 8 | 100 to 125 Km |
| 9 | Repairing/restoration of Feeder Piller/meter boxwith concrete base using hired welder, welding machine and cutter at site. |
| 10 | Supply and installation of the following spare parts, fittings, and appliances for attending to faults in the TE building, BTS sites, quarter complexes, and IQs, including the removal of faulty accessories for smooth operation, as required.Note: The warranty period of the supplied products is to be verified by this office. The warranty termination date should be clearly mentioned on the product using a permanent marker, along with the vendor\"s signature. If the product malfunctions within the warranty period, it must be replaced free of cost. |
| 11 | 63 AFuse |
| 12 | 32 A Fuse |
| 13 | 100 A Fuse |
| 14 | MS Sheet 16 SWG per Sq Meter |
| 15 | SP MCB (6 A - 25 A) |
| 16 | TPN MCB (32 A) |
| 17 | TPN MCB (40 A) |
| 18 | TPN MCB (63 A) |
| 19 | 4 Pole Isolator 63 A |
| 20 | DP Isolator (32-63 A) |
| 21 | DP Isolator (63 A) |
| 22 | LED Lamp (3-9 W) |
| 23 | LED Lamp (12-15 W) |
| 24 | LED Lamp (18-23 W) |
| 25 | LED Lamp (30-50 W) |
| 26 | Aluminium Bulb Shade for Outdoor |
| 27 | LED Street Light (25 - 30W) |
| 28 | LED Street Light (45 W) |
| 29 | PVC Holder (Angle/Batten) |
| 30 | PVC Holder (pendant) |
| 31 | LED Tube light 18-20 W |
| 32 | 6 A Switch |
| 33 | 16 A Switch |
| 34 | 6A socket (ISI Marked) |
| 35 | 16A Socket |
| 36 | 3 Pin Top (6 A) |
| 37 | 3 Pin Top (16 A) |
| 38 | Single core FRLS 1.5 Sq.mm Cu wire |
| 39 | Single Core FRLS 2.5 Sq.mm Cu wire |
| 40 | Single Core FRLS 4 Sq.mm Cu wire |
| 41 | Single Core FRLS 6 Sq.mm Cu wire |
| 42 | Single Core FRLS 10 Sq.mm Al wire |
| 43 | Single Core FRLS 16 Sq.mm Al wire |
| 44 | 4 core 16 Sq.mm armoured Al conductor Sq.mm |
| 45 | 3.5 core 35 Sq.mm armoured Al conductor Sq.mm |
| 46 | 1.5 sqmm 2 core Cu round flexible Sheathed Cable |
| 47 | 1.5 sqmm 3 core Cu round flexible Sheathed Cable |
| 48 | 4 sqmm 2 core Al round flexible Sheathed Cable |
| 49 | 4 sqmm 3 core Al round flexible Sheathed Cable |
| 50 | Cu Lugs 1.5 Sqmm |
| 51 | Cu Lugs 2.5 Sqmm |
| 52 | Cu Lugs 4 Sqmm |
| 53 | Cu Lugs 6 Sqmm |
| 54 | Cu Lugs 10 Sqmm |
| 55 | Al Lugs 16 Sqmm |
| 56 | Al Lugs 25 Sqmm |
| 57 | Al Lugs 35 Sqmm |
| 58 | Al Lugs 50 Sqmm |
| 59 | Ceiling Rose (3 Plate) |
| 60 | 3\"x3\" PVC Box |
| 61 | 4\"x4\" PVC Box |
| 62 | 7\" x 4\" PVC Board |
| 63 | 6\" x 8\" PVC Board |
| 64 | 32x12 mm Casing |
| 65 | 38 x 16 mm Casing |
| 66 | 63 A Triple Pole with Neutral Link, 415 V AC, 50 Hz SFU with Metal seal enclosere |
| 67 | 63 A, 4 Pole Offload/onload Changeover Switch- AC 21 (side handle) in sheet enclosure, 415 V AC, 50 Hz |
| 68 | 380 mm Exhaust Fan 900 rpm Heavy duty (Industriel type) |
| 69 | 380 mm Exhaust Fan louvre Shutter |
| 70 | 300 mm Exhaust Fan 1350 rpm Semi comercial (Double ball bearing) |
| 71 | 300 mm Exhaust Fan louvre Shutter |
| 72 | Timer Unit for cyclic operation of exhaust fan (L&T / GIC) |
| 73 | Rewinding of 380 mm/300 mm Exhaust Fan |
| 74 | Tube Light Starter |
| 75 | 1200 mm Ceiling Fan |
| 76 | Wall Fan (400 mm 3 blade) |
| 77 | Fan Bearing |
| 78 | Fan Rewinding |
| 79 | 2.5 mFD Fan Capacitor |
| 80 | Digital Clamp Meter (Mk-MECO, 400A AC/DC Auto Ranging) with DC/AC current/voltage measuring facility |