Tender For Annual Plan-Padivayal Take A Break Electrification @Muppainad Gp-S0351/25-General Electrical Work - ELECTRIFICATION 2 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C 3 1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire 4 1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 5 1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire 6 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm 7 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm 8 1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). 9 1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 10 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 11 1.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 12 1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 13 1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required. 14 OD511494/2024-2025:Supply and fixing of 9W LED 15 90.3.20.4:Supply & installation of light fittings on TW round block <br> Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thicknesscomplete with all accessories andlamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 2X20W LED Lamp with box type fixture 16 90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. 17 90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply 18 OD511883/2024-2025:supply of 150mm sweep Light Duty Exhaust fan in plastic body with self opening lowers working on 230V single phase A/C 19 1.50.1:Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep 20 90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required. 21 90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 22 90.3.18.1:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.25 mm dia with HG company fabricated clamps 23 2.3.4:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door 24 2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 25 2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole 26 2.14.2:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residualcurrent circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 27 2.16:Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts C curve DP MCB complete with connections, testing and commissioning etc. as required. 28 90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) 29 OD511493/2024-2025:Supply and installation of dust and vermin proof single-phase Sintex meter board(GS-MB-3525) [350 x 250 x 150] and to fix KSEB meters, fuse units, CTs, etc. as required including fixing it on the wall, making good the damages, color washing etc. as required. 30 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 31 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 32 OD511495/2024-2025:Supply and fixing of 32A, Bakelite HRC fuse with HRC fuse link 33 OD511492/2024-2025:Supplying and fixing 32A, 2 way Bakelite Neutral link mounted on DMC/SMC base with connection, in the existing meter board 34 OD511496/2024-2025:Supply and fixing of 8mm GI hook for supporting service wire in the existing parapet/wall 35 OD511735/2024-2025:Supply andinstallation testing and commissioning 1HP open well submersible, Monoblocks,Horizontal type Water cooled motor pump set having 2900 RPM, suitable for Single phase, 240V 50 Hz, AC supply conform to relevant ISS. Head 20/28 m,with a flow rate of 200/90 LPM and should provide 200 LPM at a head of 20m , 90LPM at a head of 28m with standard size delivery pipe (1inch) connecting to the motor using leakproof materials with GI supporting hook as required including giving connection as per the direction of the engineer.,(Kirloskar/Texmo/Crompton/Deccan or equivalent brands),conforms to IS 14220/1. 36 OD511739/2024-2025:Supply and connect a 1- inch HDPE pipe ISI (10 kg/cm2) to the existing pump set and as a delivery pipe with suitable connectors. 37 OD511740/2024-2025:Supply and installation of 1- inch Cast iron barrel nipple 38 OD511741/2024-2025:Supply and providing 1- inch or nearest size stainless steel Hose collar with hose clip 39 OD511742/2024-2025:Supply and fix 1- inch or nearest size GI flange with the required bolt, nut, washer and gasket etc. 40 OD511743/2024-2025:Supply and installation of 1- inch full way valve 41 OD511756/2024-2025:Supply and providing 1- inch or nearest size dia Gun metal non return valve (ISI) 42 OD511745/2024-2025:S & F Motor starters of the following ratings submersible pump controller with ammeter , voltmeter, pushbuttons, capacotor, indicator with IP 54 for single phase 140-270 V, 1-2 hp pumpset. Overload relay range 13.2-20 Amp with dimensions 8x4x10 cm and a minimum of one year warranty.( Havels, L&T) 43 OD511746/2024-2025:Supply and laying of 20mm or nearest size Nylon rope 44 90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size 45 90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm 46 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 47 5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 48 OD519280/2024-2025:Providing and fixing 2 X 25 mm X 3 mm GI striptest joint for earthing system 49 5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.