| 1 | CREATION OF 2 No\"s 100 KVA SUB-STATION each at MANJOOS WSS at Banihal UNDER JJM |
| 2 | 11/0.433KV, 3-phase Copper wound 250 KVA Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, , and with LV Cable Box having detachable Aluminium Gland plate |
| 3 | Gapless Surge Arrestor,9 KV ,10 KA ,LA with (polymer/porcelain) housing, Stn. Type |
| 4 | 11 kV G.O AB Switch , 3-phase, 3 pole 200 Amp. Vertical type |
| 5 | 11 kV Horn Gap Fuse Set 3 Phase3 pole, 200 Amp |
| 6 | 70 mm² (2Ckt) Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type |
| 7 | 9 Mtr. Long Pole( ST-540 SP33) |
| 8 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 9 | GI Channel/Angle/Flat of sizes including clamps |
| 10 | Chainlink Fencing of Sub station Yard by way of mass concrete in foundations and chain link fenscing of 6 Ft Height. |
| 11 | Galvinized Nuts and Bolts. |
| 12 | Earthing of substation --Excavation of earth pit of dia 650 mm &depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75 mmx10 mm & 50mmx6 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
| 13 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 14 | LT Fuse set |
| 15 | Wedge Connectors / PG Clamps |
| 16 | Danger Plates with Clamps |
| 17 | GI Barbed Wire for Anti Climbing |
| 18 | Cement bottoming 1:2:4 mix as per REC standards .5cum /pole |
| 19 | Painting of Poles Red Oxide |
| 20 | Painting of Poles Aluminium Paint |
| 21 | Sundry items like aluminium lugs, Jumpers, binding Tape |
| 22 | Erection of HT line on 9 mtrs ST Poles with 30mmsq Conductor forCREATION OF 2 No\"s 100 KVA SUB-STATION each at MANJOOS WSS at Banihal UNDER JJM |
| 23 | 9 Mtr ST pole (ST-410 SP 33) |
| 24 | GI V Cross Arm with top bracket including Clamp |
| 25 | GIchannel x-Arm including Clamps and braces |
| 26 | 11 KV Polymer Composite Pin Insulator |
| 27 | 30 mm Sq ACSR Conductor |
| 28 | PG Clamps for 30 mm sq ACSR Conductor |
| 29 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
| 30 | Galvanized Nuts and Bolts |
| 31 | Danger Plates with Clamps |
| 32 | Anti Climb Device With Clamp |
| 33 | Earthing of Poles complete by G.I pipe 40mm or GI Rod 20mm 2.5 mtr long through GI Strip |
| 34 | Red Oxide |
| 35 | Aluminnium Paint |
| 36 | Cement Bottomming 1:2:4 mix as per REC Standards 0.5cum per pole |
| 37 | Erection of LT line on 8 mtrs ST Poles with 120 sqm ABC Cable forCREATION OF 2 No\"s 100 KVA SUB-STATION each at MANJOOS WSS at Banihal UNDER JJM |
| 38 | 8 Mtr ST pole (ST-410 SP 15) |
| 39 | 120 mm² AB (LT) Cable ( 3 x 120 + 1 x 16 + 1 x 70 mm²) XLPE(1.1kV, 3+1 C, Al) |
| 40 | Suspension/Tension clamp with eye hook |
| 41 | Straight through cable joint Kit |
| 42 | Galvanized Nuts and Bolts |
| 43 | Danger plates |
| 44 | anti-Climbing Device with clamps |
| 45 | Earthing with GI pipes 40MM or GI Rod 20MM 2.5 Mtr long through GI strip |
| 46 | Red oxide |
| 47 | Aluminium paint |
| 48 | Cement Bottoming 1:2:4 mix as per REC standards 0.45cum/pole |
| 49 | Insulating peircing connectors |
| 50 | PG Clamps for 30 mm sq ACSR Conductor |
| 51 | Galvanized stay set with 50*8mm stay clamp,guy insulator(2no)anchor plate(200*200*6mm),nut-bolt,2no turn buckles,1.8m long,16mm diameter solid GS stay Rod & 7/3.15 mm dia GI stranded wire complete |
| 52 | Erection of LT line on 8 mtrs ST Poles with ACSR 30SQM Conductor forCREATION OF 2 No\"s 100 KVA SUB-STATION each at MANJOOS WSS at Banihal UNDER JJM |
| 53 | 8 Mtr ST pole (ST-410 SP 33) |
| 54 | Clamp for Shakle Insulator |
| 55 | 30 mm Sq ACSR Conductor |
| 56 | 16 kN Polymer Shakle Insulator |
| 57 | Galvanized Nuts and Bolts |
| 58 | Danger Plates |
| 59 | Anti Climb Device With Clamp |
| 60 | Earthing of Pole |
| 61 | Red Oxide |
| 62 | Aluminnium Paint |
| 63 | Cement Bottomming 1:2:4 mix as per REC Standard |