Tender For Rate Contract For Supply Of Electric Items For Fy 2025-26 - Providing & Fixing of IKUR, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover)/Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each. The System efficacy 125 Im/wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @300 V AC and Auto resetting Salety, Power Factor >0.95 driver Efficiency >85%, THD(0) <10% Humidity 10% to 90% RH Working Temp -SC to 45C. driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Ufe Expectancy Equal or more than 50000 buming hrs with Minimum 70% lumen maintened, CRI >70 and CCT 5700K +355K. Surge protection shall be min 2 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced. DEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LMBO) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/work, refer Annexure A attached with this BSA. LED Street Light fixture with Minimum lumen output 3700 lm LED Street Light fixture with Minimum lumen output 5600lm LED Street Light fixture with Minimum lumen output 8700 im Providing & Laying P.V.C/XLPE insulated & P.V.C. sheathed Un-Armoured Aluminium cable confirming to 15:15541-4/15:7088 P-1 of 1.1 KV with H4-Grade electrolytic aluminium conductor confirming to 15 8130 of purity >99.5%, Inner/outer sheath confirming to 15:5831 in existing RCC/Hume/Stoneware/PVC pipe/open duct/cable trench/Cable tray (with cable tie) including testing etc, as required of following size. OEM must have its own in house NABI, accrediated Laboratory for testing procedure as per 15:10810. For additional technical parameters of product/work refer Annexure A attached with this BSR Gsqmm 2Core 105qmm 2Core 65qmm 3Core 105qmm 3Core Providing & Fising of AC operated heavy duty 230/440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1:2000 having provision of mechanical interlocking, ausilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR. 3 pole Power contactors with following AC 3 Rating 40Amp Providing & Fuing of mechanical/digital time switch having following day/week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming το IEC 60730-1 and 50730-2-7 etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/work, refer Annexure A attached with this BSR. One day reserve (Analog type) P&F of 240 V Electronic ON-OFF Timer 3-30 Sec/12-120 Sec including making Connection etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/work, refer Annexure A attached with this S P&F of 415 V Electronic ON-OFF Timer 3-30 Sec/12-120 Sec including making Connection etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/work, refer Annexure A attached with this BSR. Providing & Fiảng of 240/415 V AC MCB with positive isotation of 10 kA breaking capacity (B/C/D tripping characteristic as per type of load and site requirement) 4 XV impulse withstand voltage, marked S 8823(1996)/conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisan, energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm, conductor line load reversibility, IP 20 contact protection and fitted in existing distribution board/sheels, minimum slectrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL/CPRI/ERDA accrediated lah type last reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product/werk refer Annexure A attached with this BSR Scan 12 Triple pole MCB (With B/C curve trippingCharacteristics) 6Mimp Sit of 1/4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat tentant material having following current rating, short crest breaking capacity at 440/415 V, 50 Hz: O/L & S/C settings, conforming to 15/1EC 609471-2:2001 with front face and centralised adpintable, trip free mechanisum, true contact position indicator, tine load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, satable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive holation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity ict 100% ICU. U imp 8 KV, rated insulation voltage 690 V. provision for UVB, shunt trap, earth faut trip, door interlock, pad lock & rotary handle, including making connections ett, as required. OEM shall have submit NABL/CPRI/ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in-charge. For 3 additional technical parameters of product/work refer Annexure A attached with this BSR 4 pole MCCB With Thermal Magnetic release up to 100 Amp, 10 AA, flised O/L & fixed S/C setting 4 200 Amp, 25 kA, adjustable O/L & adjustable S/C setting Providing & Fising of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, 15 marked 15 R828(1996)/conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum, energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq mm., conductor line load reversibility, IP 20 contact protection and fitted in existing distribution buard/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL/CPRI/ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product/work refer Annexure A attached with this 858 5 Single pole MCB (With B/C curve tripping Characteristics) 40Amp part B Wire Coil 7/10 HRC Fuse Grip 200Amp Complete Tape Roll PVC Wire Coil 2C 4mm Wire Coil 2C 6mm Wire Coil 2C 10mm Plyer Tester Set Voltmeter Timer switch with complete contactor