}

Tender For Supply, Installation Testing And Commissioning Of Replacement Of Existing Forced Air Supply An Exhaust System In Bldg No 7 And Installation Of New Gaseous Effluent Treatment Plant(Getp) Setup For Interfacing Of Exhaust System Of Bldg No 7, Visakhapatanam-Andhra Pradesh

Indian Navy has published Tender For Supply, Installation Testing And Commissioning Of Replacement Of Existing Forced Air Supply An Exhaust System In Bldg No 7 And Installation Of New Gaseous Effluent Treatment Plant(Getp) Setup For Interfacing Of Exhaust System Of Bldg No 7. Submission Date for this Tender is 28-04-2025. Effluent Treatment Plant Tenders in Visakhapatanam Andhra Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

48266875
Corrigendum : Tender For Supply, Installation Testing And Commissioning Of Replacement Of Existing Forced Air Supply An Exhaust System In Bldg No 7 And Installation Of New Gaseous Effluent Treatment Plant(Getp) Setup For Interfacing Of Exhaust System Of Bldg No 7
Open Tender
Indian
Andhra Pradesh
Visakhapatanam
28-04-2025

Tender Documents

Tender Details

Supply, Installation Testing And Commissioning Of Replacement Of Existing Forced Air Supply An Exhaust System In Bldg No 7 And Installation Of New Gaseous Effluent Treatment Plant(Getp) Setup For Interfacing Of Exhaust System Of Bldg No 7 , Supply, Installation Testing And Commissioning Of Replacement Of Existing Forced Air Supply & Exhaust System In Bldg No – 7 And Installation Of New Gaseous Effluent Treatment Plant (Getp) Setup For Interfacing Of Exhaust System Of Bldg No 7 & Bldg 7 Extn With Getp At Ece Department At Nd (V) , Fresh Air Fan Of Capacity 36000 Cfm (Refers To Para 3.1 Of Part Ii Of Rfp) , Exhaust Air Ventilation Fan Of Capacity - 40000 Cfm (Refers To Para 3.2 Of Part Ii Of Rfp) , Exhaust Air Ventilation Fan Of Capacity - 36000 Cfm (Refers To Para 3.3 Of Part Ii Of Rfp) , Packed Tower For 80000 Cfm Scrubber System (Refers To Para 3.4 Of Part Ii Of Rfp) , Recirculation Tank For 80000 Cfm Scrubber System (Refers To Para 3.5 Of Part Ii Of Rfp) , Recirculation Skid For 80000 Cfm Scrubber System (Refers To Para 3.6 Of Part Ii Of Rfp) , Bio Wet Scrubber For 80000 Cfm Scrubber System (Refers To Para 3.7 Of Part Ii Of Rfp) , Packed Tower For 40000 Cfm Scrubber System (Refers To Para 3.8 Of Part Ii Of Rfp) , Recirculation Tank For 40000 Cfm Scrubber System (Refers To Para 3.9 Of Part Ii Of Rfp) , Recirculation Skid For 40000 Cfm Scrubber System (Refers To Para 3.10 Of Part Ii Of Rfp) , Bio Wet Scrubber For 40000 Cfm Scrubber System (Refers To Para 3.11 Of Part Ii Of Rfp) , Dp Gauge (Refers To Para 3.12 Of Part Ii Of Rfp) , Level Gauge (Refers To Para 3.13 Of Part Ii Of Rfp) , Manual Ball Valve (Refers To Para 3.14 Of Part Ii Of Rfp) , Manual Ball Valve For Bleed Off Line (Refers To Para 3.15 Of Part Ii Of Rfp) , Pressure Gauge (Refers To Para 3.16 Of Part Ii Of Rfp) , Pressure Switch (Refers To Para 3.17 Of Part Ii Of Rfp) , Non Returning Valve (Refers To Para 3.18 Of Part Ii Of Rfp) , Support Structure & Platform For Scrubber System, Exhaust/ Fresh Air Fan And Air Flow Duct (Refers To Para 3.19 Of Part Ii Of Rfp) , Electrical Control Panel (Refers To Para 3.20 Of Part Ii Of Rfp) , Xlpe, Armoured, 1.1 Kv, Lt Cable 3.5 Core 240 Sqmm (Refers To Para 3.21 Of Part Ii Of Rfp) , Xlpe, Armoured, 1.1 Kv, Lt Cable 3.5 Core 185 Sqmm (Refers To Para 3.22 Of Part Ii Of Rfp) , Xlpe, Armoured, 1.1 Kv, Lt Cable 4 Core 70 Sqmm (Refers To Para 3.23 Of Part Ii Of Rfp) , Xlpe, Armoured, 1.1 Kv, Lt Cable 4 Core 25 Sqmm (Refers To Para 3.24 Of Part Ii Of Rfp) , Galvanised Perforated Type Cable Tray Of 600Mm Width (Refers To Para 3.25 Of Part Ii Of Rfp) , Galvanised Perforated Type Cable Tray Of 300Mm Width (Refers To Para 3.26 Of Part Ii Of Rfp) , Supporting Structure For Cable Tray (Refers To Para 3.27 Of Part Ii Of Rfp) , Establishment Of Earthing Pits (Refers To Para 3.28 Of Part Ii Of Rfp) , Gi Earthing Strip 50 X 6Mm Gi Flate (Refers To Para 3.29 Of Part Ii Of Rfp) , Gi Earthing Strip 40 X 6Mm Gi Flate (Refers To Para 3.30 Of Part Ii Of Rfp) , Gi Earthing Strip 25 X 6Mm Gi Flate (Refers To Para 3.31 Of Part Ii Of Rfp) , Gi Earthing Strip 25 X 3Mm Gi Flate (Refers To Para 3.32 Of Part Ii Of Rfp) , Gi Pipe 50Mm Dia Medium Grade With Frp Coating (Refers To Para 3.33 Of Part Ii Of Rfp) , Frp Ducting For Fresh/ Exhaust Air (Refers To Para 3.34 Of Part Ii Of Rfp) , Air Quality Transmitter (Refers To Para 3.35 Of Part Ii Of Rfp) , Air Quality Monitor (Refers To Para 3.36 Of Part Ii Of Rfp) , Volume Control Damper (Refers To Para 3.37 Of Part Ii Of Rfp) , Non Return Damper (Refers To Para 3.38 Of Part Ii Of Rfp) , Fire Rated Canvas Cloth For Protection Of Duct (Refers To Para 3.39 Of Part Ii Of Rfp) , Discrete Grill (Refers To Para 3.40 Of Part Ii Of Rfp) , Drum Louvers (Refers To Para 3.41 Of Part Ii Of Rfp) , Aluminium Collar Dampers (Refers To Para 3.42 Of Part Ii Of Rfp) , Fresh Air Louver (Refers To Para 3.43 Of Part Ii Of Rfp) , Dismantling And Shifting Of Existing Forced Air Ventilation System (Refers To Para 3.44 Of Part Ii Of Rfp) , Appcb Clearance Certificate (Refers To Para 3.45 Of Part Ii Of Rfp) , Civil Work (Refers To Para 11 Of Part Ii Of Rfp) , Standard Accessories (Refers To Para 14 Of Part Ii Of Rfp) , Twoyears Operation & Maintenance Spares (Refers To Para 15 Of Part Ii Of Rfp) , Special Maintenance Toolsand Test Equipment (Refers To Para 16 Of Part Ii Of Rfp) , Technical Literature / Certificates / Documentation (Refers To Para 17 Of Part Ii Of Rfp) , Acceptance, Tests, Trials And Commissioning Charges (Refers To Para 22 Of Part Ii Of Rfp) , Training(Refers To Para 25 Of Part Ii Of Rfp) , Any Other Item Such As Transportation, Insurance, Freight, Packing Etc , Notes: 1. Cost Of Item Listed At Sl 1.01 To 1.45 And8 (If Applicable) Are To Be Quotedin The Respective Rows Of The Price Bid Sheet. 2. Bidder Not Permitted To Include Cost Of Items Listed At Sl 2 To 8 With Sl 1.01 To 1.45 As Lumpsum Amount3. Bidder Required To Mandatorily Quote For Sl 1.01 To 1.45 And8 Failing Which Bid Shall Be Treated As Non Bonafied And Liable For Rejection. 4. Bidders Are Mandatorily To Quote Gst/ Taxes As Applicable Against Each Serials, Falling Which Bid Shall Be Treated As Non Bonafied And Liable For Rejection.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 04-04-2025 CORRIGENDUM NO.1 Date 28-04-2025

Key Value

Document Fees
INR 1000 /-
EMD
INR 1121000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail