Tender For Internal Electrification Work In The Authoritys Spz Scheme - Distribution Substation Package Sub Station With Apfc Panel Supplying Installation Testing And Commissioning Of 11/0.4Kv 500 Kva Package Sub Stations With Apfc Panel As Details Below, bharatpur-Rajasthan

Urban Improvement Trust has published Tender For Internal Electrification Work In The Authoritys Spz Scheme - Distribution Substation Package Sub Station With Apfc Panel Supplying Installation Testing And Commissioning Of 11/0.4Kv 500 Kva Package Sub Stations With Apfc Panel As Details Below. Submission Date for this Tender is 03-04-2025. Electrification Work Tenders in bharatpur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

48250936
Tender For Internal Electrification Work In The Authoritys Spz Scheme - Distribution Substation Package Sub Station With Apfc Panel Supplying Installation Testing And Commissioning Of 11/0.4Kv 500 Kva Package Sub Stations With Apfc Panel As Details Below
Open Tender
NCB
Rajasthan
Bharatpur
03-04-2025

Tender Documents

Tender Details

Tender For Internal electrification work in the Authoritys SPZ scheme - DISTRIBUTION SUBSTATION PACKAGE SUB STATION WITH APFC PANEL Supplying installation testing and commissioning of 11/0.4KV 500 KVA Package sub stations with APFC panel as details below:-PSS/RMU-1A/1 (BLOCK-A)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I, EEL1TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 500 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 1000 AR/Y/B indicating lampsLT PANEL Incomer ACB, 800A, MDO 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamp & Multifunction meterENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU -1A/1 described as above. 2 Supplying installation testing and commissioning of 11/0.4KV 315 KVA Package sub stations with APFC panel as details below:-PSS/RMU-2A/4 (BLOCK-A)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I, EEL1TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 500 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 1000 AR/Y/B indicating lampsLT PANEL Incomer ACB, 800A, MDO 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamp & Multifunction meterOutgoing i. 100A, 4 Pole , 25KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 2nosii. 200A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 2nosiii. 250A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 1nosiv. 320A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 1nosv. 400A, 4 Pole ,36KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 165kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU -2A/4 described as above. 3 PSS/RMU-1A/2 (BLOCK-A)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I, EEL-1TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 315 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 630 AR/Y/B indicating lampsLT PANEL Incomer MCCB, 500A, 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamp & Multifunction meterENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-1A/2described as above. 4 PSS/RMU-1A/3 (BLOCK-A)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I, EEL-1TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 315 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 630 AR/Y/B indicating lampsLT PANEL Incomer MCCB, 500A, 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamp& Multifunction meterENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-1A/3 described as above. 5 Supplying installation testing and commissioning of 11/0.4KV 630 KVA Package sub stations with APFC panel as details below:-PSS/RMU-2A/2 (BLOCK-A)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I, EEL-1TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 315 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 630 AR/Y/B indicating lampsLT PANEL Incomer MCCB, 500A, 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamp& Multifunction meterOutgoing i. 250A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 3nosii. 250A, 4 Pole ,36KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 105kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-2A/2 described as above. 6 PSS/RMU-2A/1 (BLOCK-A)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I , EEL-1 TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 630 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 1250AR/Y/B indicating lampsLT PANEL Incomer ACB, 1000A, MDO 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamp & Multifunction meterOutgoing i. 63A, 4 Pole , 25KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 1nosii. 200A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 4nosiii. 320A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-3nosiv. 500A, 4 Pole ,36KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 200kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-2A/1 described as above. 7 PSS/RMU-2A/3 (BLOCK-A)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I, EEL-1TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 630KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 1250 AR/Y/B indicating lampsLT PANEL Incomer ACB, 1000A, MDO 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamp & Multifunction meterOutgoing i. 250A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 2nosii 320A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 3nosiii. 500A, 4 Pole ,35KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 200kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-2A/3 described as above. 8 Supplying installation testing and commissioning of 11/0.4KV 500 KVA Package sub stations with APFC panel as details below:-PSS/RMU-2A/5 (BLOCK-A)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I , EEL-1 TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 630KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 1250 AR/Y/B indicating lampsLT PANEL Incomer ACB, 1000A, MDO 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamp & Multifunction meterOutgoing i. 250A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 2nosii320A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-3nosiii. 500A, 4 Pole ,36KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 200kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-2A/5 described as above. 9 PSS/RMU-B1 (BLOCK-B)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I, EEL-1 TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 500 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fittings AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 1000 AR/Y/B indicating lampsLT PANEL Incomer ACB, 800A, MDO 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamp & Multifunction meterOutgoing i. 63A, 4 Pole, 25KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-1nosii. 100A, 4 Pole , 25KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-1nosiii. 160A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-3nosiv200A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault releasewith ON/OFF-2nosv. 400A, 4 Pole ,36KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 165kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-B1 described as above. 10 Supplying installation testing and commissioning of 11/0.4KV 315 KVA Package sub stations with APFC panel as details below:-PSS/RMU-B2 (BLOCK-B)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I, EEL-1 TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 500 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fittings AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 1000 AR/Y/B indicating lampsLT PANEL Incomer ACB, 800A, MDO 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamp & Multifunction meterOutgoing i. 125A, 4 Pole , 25KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-1nosii. 250A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-2nosiii. 320A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-2nosiv. 400A, 4 Pole ,36KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 165kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-B2 described as above. 11 PSS/RMU-B3 (BLOCK-B)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I, EEL-1 TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 315 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 630AR/Y/B indicating lampsLT PANEL Incomer MCCB, 500A, 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamp & Multifunction meterOutgoing i. 160A, 4 Pole, 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-3nosii. 200A, 4 Pole, 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-2nosiii. 250A, 4 Pole, 36 KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 105kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-B3 described as above. 12 PSS/RMU-B4 (BLOCK-B)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I, EEL-1 TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 315 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 630AR/Y/B indicating lampsLT PANEL Incomer MCCB, 500A, 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamp & Multifunction meterOutgoing i. 250A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-3nosii. 250A, 4 Pole , 36 KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 105kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-B4 described as above.Supplying installation testing and commissioning of 11/0.4KV 500 KVA Package sub stations with APFC panel as details below:- 13 PSS/RMU-C1 (BLOCK-C)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I, EEL-1 TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 500 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fittings AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 1000 AR/Y/B indicating lampsLT PANEL Incomer ACB, 800A, MDO 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamp & Multifunction meterOutgoing i. 200A, 4 Pole, 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-2nosii. 250A, 4 Pole, 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-3nosiii. 400A, 4 Pole,36KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 165kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-C1 described as above. 14 PSS/RMU-C5(BLOCK-C)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I, EEL-1 TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 500 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fittings AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 1000 AR/Y/B indicating lampsLT PANEL Incomer ACB, 800A, MDO 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamp & Multifunction meterOutgoing i. 200A, 4 Pole, 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-2nosii. 250A, 4 Pole, 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-3nosiii. 400A, 4 Pole,36KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 165kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-C5 described as above.Supplying installation testing and commissioning of 11/0.4KV 315 KVA Package sub stations with APFC panel as details below:- 15 PSS/ RMU-C2(BLOCK-C)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I, EEL-1 TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 315 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 630AR/Y/B indicating lampsLT PANEL Incomer MCCB, 500A, 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamp & Multifunction meterOutgoing i. 63A, 4Pole, 25KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-1nosii. 125A, 4Pole, 25KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-2nosiii. 160A, 4Pole, 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-2nosiv. 250A, 4Pole, 36 KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 105kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-C2described as above. 16 PSS/RMU-C3(BLOCK-C)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I, EEL-1 TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 315 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 630AR/Y/B indicating lampsLT PANEL Incomer MCCB, 500A, 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamp & Multifunction meterOutgoing i. 160A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-5nosii. 250A, 4 Pole , 36 KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 105kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-C3 described as above. 17 PSS/RMU-C4(BLOCK-C)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I, EEL-1 TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 315 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 630AR/Y/B indicating lampsLT PANEL Incomer MCCB, 500A, 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamp & Multifunction meterOutgoing i. 125A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-4nosii. 250A, 4 Pole , 36 KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 105kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-C4 described as above.Supplying installation testing and commissioning of 11/0.4KV 500 KVA Package sub stations with APFC panel as details below:- 18 PSS/RMU-D1 (BLOCK-D)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I, EEL-1 TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 500 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fittings AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 1000 AR/Y/B indicating lampsLT PANEL Incomer ACB, 800A, MDO 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamp & Multifunction meterOutgoing i. 160A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-2nosii. 200A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-1nosiii. 250A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-3nosiv. 400A, 4 Pole ,36KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 165kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-D1 described as above. 19 PSS/RMU-D3 (BLOCK-D)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I, EEL-1 TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 500 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fittings AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 1000 AR/Y/B indicating lampsLT PANEL Incomer ACB, 800A, MDO 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamp & Multifunction meterOutgoing i. 200A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-3nosii. 250A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-2nosiii. 400A, 4 Pole ,36KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 165kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-D3 described as above.Supplying installation testing and commissioning of 11/0.4KV 315 KVA Package sub stations with APFC panel as details below:- 20 PSS/RMU-D2 (BLOCK-D)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I, EEL-1TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 315 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 630AR/Y/B indicating lampsLT PANEL Incomer MCCB, 500A, 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamp & Multifunction meterOutgoing i. 160A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release 1nosii. 200A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release 3nosiii. 250A, 4 Pole , 36 KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 105kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-D2 described as above.Supplying installation testing and commissioning of 11/0.4KV 500 KVA Package sub stations with APFC panel as details below:- 21 PSS/RMU-E1 (BLOCK-E)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I, EEL-1TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 500 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 1000 AR/Y/B indicating lampsLT PANEL Incomer ACB, 800A, MDO 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamp & Multifunction meterOutgoing i. 200A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 1nosii. 250A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-4nosiii. 400A, 4 Pole ,36KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 165kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-E1 described as above. 22 PSS/RMU-E2 (BLOCK-E)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I , EEL-1TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 500 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 1000 AR/Y/B indicating lampsLT PANEL Incomer ACB, 800A, MDO 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamp & Multifunction meterOutgoing i. 160A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 3nosii200A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-1nosiii250A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-2nosiv. 400A, 4 Pole ,36KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 165kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-E2 described as above. 23 PSS/RMU-E4 (BLOCK-E)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I , EEL-1TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 500 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 1000 AR/Y/B indicating lampsLT PANEL Incomer ACB, 800A, MDO 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamp & Multifunction meterOutgoing i. 200A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 2nosii250A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-3nosiii. 400A, 4 Pole ,36KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 165kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-E4 described as above.Supplying installation testing and commissioning of 11/0.4KV 315 KVA Package sub stations with APFC panel as details below:- 24 PSS/RMU-E3 (BLOCK-E)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I, EEL-1TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 315 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fittings AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 630AR/Y/B indicating lampsLT PANEL Incomer MCCB, 500A, 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamp & Multifunction meterOutgoing i. 63A, 4 Pole , 25KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-1nosii. 160A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-4nosiii. 200A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-2nosiv. 250A, 4 Pole , 36 KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 105kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-E3 described as above.Supplying installation testing and commissioning of 11/0.4KV 315 KVA Package sub stations with APFC panel as details below:- 25 PSS/RMU-F1 (BLOCK-F)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I, EEL-1TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 315 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 630AR/Y/B indicating lampsLT PANEL Incomer MCCB, 500A, 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamp & Multifunction meterOutgoing i. 200A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 1nosii. 320A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 3nosiii. 250A, 4 Pole , 36 KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 105kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-F1 described as above. 26 PSS/RMU-F4 (BLOCK-F)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I, EEL-1TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 315 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 630AR/Y/B indicating lampsLT PANEL Incomer MCCB, 500A, 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamp & Multifunction meterOutgoing i. 63A, 4 Pole , 25KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 1nosii. 200A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 2nosiii. 250A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 1nosiv. 250A, 4 Pole , 36 KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 105kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-F4 described as above.Supplying installation testing and commissioning of 11/0.4KV 500 KVA Package sub stations with APFC panel as details below:- 27 PSS/RMU-F2 (BLOCK-F)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I, EEL-1TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 500 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 1000 AR/Y/B indicating lampsLT PANEL Incomer ACB, 800A, MDO 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamp & Multifunction meterOutgoing i. 250A, 4 Pole, 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-5nosii. 400A, 4 Pole,36KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 165kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-F2 described as above. 28 PSS/RMU-F3 (BLOCK-F)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I, EEL-1 TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 500 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 1000 AR/Y/B indicating lampsLT PANEL Incomer ACB, 800A, MDO 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamp & Multifunction meterOutgoing i. 125A, 4 Pole, 25KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-4nosii. 200A, 4 Pole, 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF-3nosiii. 400A, 4 Pole,36KA, MCCB,microprocessor based over current, short circuit and earth fault release. 1 nos for 165kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-F3 described as above. 29 PSS/RMU-F5 (BLOCK-F)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I EEL-1TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 500 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)TransformerFitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 1000AR/Y/B indicating lampsLT PANEL Incomer ACB, 800A, MDO 4 Pole, 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamps & Multifunction meter-Outgoing i. 200A, 4 Pole, 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 1nosii. 250A, 4 Pole, 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 4nosiii. 400A, 4 Pole,36KA, MCCB,microprocessor based over current, short circuit and earth fault release. 1 nos for 165kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-F5 described as above. 30 PSS/RMU-F6 (BLOCK-F)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I EEL-1TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 500 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)TransformerFitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 1000AR/Y/B indicating lampsLT PANEL Incomer ACB, 800A, MDO 4 Pole, 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamps & Multifunction meter-Outgoing i. 160A, 4 Pole, 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 2nosii. 200A, 4 Pole, 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 3nosiii. 400A, 4 Pole,36KA, MCCB,microprocessor based over current, short circuit and earth fault release. 1 nos for 165kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-F6 described as above.Supplying installation testing and commissioning of 11/0.4KV 500 KVA Package sub stations with APFC panel as details below:- 31 PSS/RMU-GH1 (GROUP HOUSING)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I, EEL-1TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 500 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 1000 AR/Y/B indicating lampsLT PANEL Incomer ACB, 800A, MDO 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release.On, OFF, RYB lamp & Multifunction meterENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-GH1 described as above.Supplying installation testing and commissioning of 11/0.4KV 630 KVA Package sub stations with APFC panel as details below:- 32 PSS/RMU-GH2 (GROUP HOUSING)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:- 3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I , EEL-1 TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 630 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 1250AR/Y/B indicating lampsLT PANEL Incomer ACB, 1000A, MDO 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamp & Multifunction meterENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-GH2 described as above. 33 PSS/RMU-GH3 (GROUP HOUSING)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I , EEL-1 TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 630 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 1250AR/Y/B indicating lampsLT PANEL Incomer ACB, 1000A, MDO 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamp & Multifunction meterENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-GH3 described as above.Supplying installation testing and commissioning of 11/0.4KV 315 KVA Package sub stations with APFC panel as details below:- 34 PSS/ RMU-EWS/LIG (GROUP HOUSING)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I, EEL-1TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 315 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 630AR/Y/B indicating lampsLT PANEL Incomer MCCB, 500A, 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamp & Multifunction meterrrection.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-EWS/LIG described as above.Supplying installation testing and commissioning of 11/0.4KV 500 KVA Package sub stations with APFC panel as details below:- 35 PSS/RMU-G1 (BLOCK-G)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I EEL-1TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 500 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 1000 AR/Y/B indicating lampsLT PANEL Incomer ACB, 800A, MDO 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamps & Multifunction meterOutgoing i. 250A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release 4nosii. 400A, 4 Pole ,36KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 165kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-G1 described as above. 36 PSS/RMU-G2 (BLOCK-G)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I EEL-1TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 500 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 1000 AR/Y/B indicating lampsLT PANEL Incomer ACB, 800A, MDO 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamps & Multifunction meterOutgoing i. 160A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release 1nosii. 200A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release 1nosiii. 250A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release 3nosiv. 400A, 4 Pole ,36KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 165kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-G2 described as above.Supplying installation testing and commissioning of 11/0.4KV 160 KVA Package sub stations with APFC panel as details below:- 37 PSS/ RMU-G3 (BLOCK-G)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-1 EEL-1TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 160 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts 11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 320 AR/Y/B indicating lampsLT PANEL Incomer MCCB, 250A, 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamps & Multifunction meterOutgoing i. 63A, 4 Pole , 25KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 2nosii. 160A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 3nosiii. 125A, 4 Pole , 25KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 55kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-G3 described as above.Supplying installation testing and commissioning of 11/0.4KV 500 KVA Package sub stations with APFC panel as details below:- 38 PSS/RMU-H1 (BLOCK-H)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I EEL-1TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 500 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 1000 AR/Y/B indicating lampsLT PANEL Incomer ACB, 800A, MDO 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamps & Multifunction meterOutgoing i. 320A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release 4nosii. 400A, 4 Pole ,36KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 165kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-H1 described as above. 39 PSS/RMU-H2 (BLOCK-H)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I EEL-1TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 500 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 1000 AR/Y/B indicating lampsLT PANEL Incomer ACB, 800A, MDO 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamps & Multifunction meterOutgoing i. 200A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release 3nosii. 320A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release 2nosiii. 400A, 4 Pole ,36KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 165kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-H2 described as above. 40 PSS/RMU-H3 (BLOCK-H)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I EEL-1TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 500 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 1000 AR/Y/B indicating lampsLT PANEL Incomer ACB, 800A, MDO 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamps & Multifunction meterOutgoing i. 160A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release 2nosii. 200A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release 1nosiii. 320A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release 3nosiv. 400A, 4 Pole ,36KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 165kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-H3 described as above. 41 PSS/RMU-H4 (BLOCK-H)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I EEL-1TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 500 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 1000 AR/Y/B indicating lampsLT PANEL Incomer ACB, 800A, MDO 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamps & Multifunction meterOutgoing i. 160A, 4 Pole, 36KA, MCCB,microprocessor based over current, short circuit and earth fault release 3nosii. 200A, 4 Pole, 36KA, MCCB,microprocessor based over current, short circuit and earth fault release 3nosiii. 400A, 4 Pole,36KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 165kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-H4 described as above.Supplying installation testing and commissioning of 11/0.4KV 315 KVA Package sub stations with APFC panel as details below:- 42 PSS/RMU-H5 (BLOCK-H)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I, EEL-1 TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 315 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 630AR/Y/B indicating lampsLT PANEL Incomer MCCB, 500A, 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF,RYB lamps & Multi function meterOutgoing i. 63A, 4 Pole , 25KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 1nosii. 125A, 4 Pole , 25KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 2nosiii. 200A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 1nosiv. 250A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 2nosv. 250A, 4 Pole , 36 KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 105kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-H5 described as above.Supplying installation testing and commissioning of 11/0.4KV 500 KVA Package sub stations with APFC panel as details below:- 43 PSS/RMU-FACILITIES-1(FACILITIES)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I EEL-1TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 500 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 1000 AR/Y/B indicating lampsLT PANEL Incomer ACB, 800A, MDO 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamps & Multifunction meterOutgoing i. 63A, 4 Pole , 25KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 1nosii. 320A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF -3nosiii. 400A, 4 Pole ,36KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 165kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-FACILITIES-1 described as above. 44 PSS/RMU-STP / PLUMBING (FACILITIES)HT Switchgear Outdoor type package substation with facility for internal lighting, earthing, padlocks etc. connection(or equivalent as approved by the Deptt.) between RMU & transformer will be by 1 nos. 3Cx300 sq.mm. Aluminium XLPE cable and connection(or equivalent as approved by the Deptt.) from transformer to LT ACB will be by Aluminium busbar connection(or equivalent as approved by the Deptt.).RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I EEL-1TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 500 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 1000 AR/Y/B indicating lampsLT PANEL Incomer ACB, 800A, MDO 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamps & Multifunction meterOutgoing i. 250A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 1nosii. 320A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF -2nosiii. 400A, 4 Pole ,36KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 165kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-STP/ PLUMBING described as above.Supplying installation testing and commissioning of 11/0.4KV 315 KVA Package sub stations with APFC panel as details below:- 45 PSS/RMU-FACILITIES-2 (FACILITIES)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I, EEL-1 TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 315 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 630AR/Y/B indicating lampsLT PANEL Incomer MCCB, 500A, 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF,RYB lamps & Multi function meterENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-FACILITIES-2 described as above. 46 PSS/RMU-FACILITIES-3 (FACILITIES)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I, EEL-1 TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 315 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 630AR/Y/B indicating lampsLT PANEL Incomer MCCB, 500A, 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF,RYB lamps & Multi function meterOutgoing i. 63A, 4 Pole , 25KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 1nosii. 250A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 1nosiii. 320A, 4 Pole , 36KA, MCCB,microprocessor based over current, short circuit and earth fault release with ON/OFF- 2nosiv. 250A, 4 Pole , 36 KA, MCCB,microprocessor based over current, short circuit and earth fault release . 1 nos for 105kVAR capacitor bank with Stepped relay(APFCR) with 8 steps (each to be of 50/20/5 KVAR) for automatic power factor correction.ENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-FACILITIES-3 described as above.Supplying installation testing and commissioning of 11/0.4KV 630 KVA Package sub stations with APFC panel as details below:- 47 PSS/RMU-SCHOOL(G) (FACILITIES)HT Switchgear Outdoor type package / Compact substation complete with RMU, Transformer & LT Breaker panel including interconnecting HT & LT Cables complete housed in weather proof housing (As per OEM Design) made out of CRCA Sheet with louvers etc. andto withstand internal arch withstand test of 20kA for one second with internal earthing with Al strips, pad locking, internal lighting complete as required.RMU-NON-Extensible (2 isolators (C), 1 Vacuum circuit breaker(T2), cu busbars, C FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit.1. Operation of LBS-Manual.2. Cable Switch Rating- 12KV, 630A, 21 KA/3 sec.3. Cable Bushing Rating-630A,4. Cable Cover:- As per our standard,5. Fixed type Capacitive voltage indication,6. On/Off/EARTH Switch via MIMIC,7. Bottom Cable Termination- Suitable up to 300sq. mm. ,T2 FUNCTION Type:-3 position Disconnection(or equivalent as approved by the Deptt.) and Earthing switch equipped with separate drive unit. T2 equipped with over current time release for transformer protection.1. Vacuum circuit breaker 12 kV, 630A, 21 KA/3 sec.2 Operation of breaker – MANUAL3 Self Powered Electronic numerical protection relay providing over-current & earth fault protection – relay.4 Ring core protection current transformers.5 Aux. contacts for VCB. ( 2 no + 2nc )6 Capacitive voltage indication fixed type.7 ON, OFF, TRIP indication on the front mimic of the panel.8 Cable box for termination of cable up to 1 No. x 300 sq. mm.9 Cable cover standard. 10 Emergency trip push button.11 Shunt trip coil – 230 V AC.Transformer TRANSFORMER (Manufactured as per IS 1180), Part-I EEL-1TYPE:- ONAN, Hermitically sealed.1. Ratio-11KV/433V,2. Capacity:- 630 KVA,3. Vector Group- DYn11,4. Off Load Tapings-+/-5% in steps of 2.5%,5. Winding- Double wound copper,6. Class of Insulation- A,7. Ambient Temperature- 50Deg C,8. Temperature rise in winding over ambient- 50Deg C,9. Temperature rise in oil over ambient- 40Deg C,9. Max losses at 50% loading - 1700 watts10. Max losses at 100% loading - 6800 watts11. Impedance - 5% ( IS tol applicable)Transformer Fitting AccessoriesAs per ISLT SwitchboardLT BUSBARS- ALUMINIUMVoltage Rating- 433VCurrent Rating- 1250AR/Y/B indicating lampsLT PANEL Incomer ACB, 1000A, MDO 4 Pole , 50 KA, microprocessor based over current, short circuit and earth fault release .On, OFF, RYB lamps & Multifunction meterENCLOSURE-HV KITEARTHING - ALUMINIUMTROLLEYCOPPER FLEXIBLEWith Oil type TransformerPSS/RMU-SCHOOL described as above. 48 Design, manufacture, supplying, erection, testing and commissioning of the following Distribution Feeder Pillar made out of 2mm thickCRCA sheet steel enclosure with slanting roof top/over hang for protection against rain, outdoor type, dust and vermin proof with IP55 whether proof protection with hinged and lockable doors complete with interconnections, electrolytic aluminium crimping lugs, brass glands, bonding to earth and painting, suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system, The FEEDER PILLAR shall be complete with all interconnections, labels wiring, etc, Erection of feeder pillar shall include Foundation(450 mm above surround ground level), excavation, back filling, PCC, Brickwork, Plastering, Providing PVC sleeves in Brick work for cables, grouting of FP in brick work, complete including removal of surplus earth work as per direction of Engineer-in-charge. FEEDER PILLAR-1(BLOCK-A) 49 INCOMER 01 no.-200 amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps. BUS BAR Al three phase and neutral busbars rated at 300 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGS i) 12 nos 40 amp 10 kA FP MCB with thermal magnetic protective releasesFEEDER PILLAR-1A (BLOCK-A) 50 INCOMER 1 no.-200 amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR ,Al three phase and neutral busbars rated at 300 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGS i) 12 nos 40 amp 10 kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-2 (BLOCK-A) 51 1 no.-200 amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR, Al three phase and neutral busbars rated at 300 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 12nos 40 amp 10 kA FP MCB with thermal magnetic protective releasesFEEDER PILLAR-2A (BLOCK-A) 52 INCOMER 1 no.-200 amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps. BUS BAR, Al three phase and neutral busbars rated at 300 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity. OUTGOINGS, i) 12nos 40 amp 10 kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-9 (BLOCK-A) 53 INCOMER 1 no.-320 amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps. BUS BAR, Al three phase and neutral busbars rated at 400 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity. OUTGOINGS,i) 7 nos 80 amp 25kA FP MCCB with thermal magnetic protective releasesFEEDER PILLAR-9A (BLOCK-A) 54 INCOMER 1 no.-320 amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps. BUS BAR,Al three phase and neutral busbars rated at 400 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity. OUTGOINGSi) 7 nos 80 amp 25kA FP MCCB with thermal magnetic protective releases 55 INCOMER 1 no.-63 amps 25kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, kwh meter & RYB Indicating lamps. BUS BAR,Al three phase and neutral busbars rated at 100 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity. OUTGOINGS i) 6 nos 20amp 10kA DP MCB with thermal magnetic protective releases ii) 6 nos 32amp 10kA DP MCB with thermal magnetic protective releasesiii) 6 nos 32amp 10kA FP MCB with thermal magnetic protective releasesiv) 6 nos 40amp 10kA FP MCB with thermal magnetic protective releases1 no.-63 amps 25kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, kwh meter & RYB Indicating lamps. BUS BAR,Al three phase and neutral busbars rated at 100 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity. OUTGOINGS i) 6 nos 20amp 10kA DP MCB with thermal magnetic protective releases ii) 6 nos 32amp 10kA DP MCB with thermal magnetic protective releasesiii) 6 nos 32amp 10kA FP MCB with thermal magnetic protective releasesiv) 6 nos 40amp 10kA FP MCB with thermal magnetic protective releasesFEEDER PILLAR-8 (BLOCK-A) 56 INCOMER1 no.-250amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity. OUTGOINGSi) 7 nos 80 amp 25kA FP MCCB with thermal magnetic protective releases 57 INCOMER 1 no.-250amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps. BUS BARAl three phase and neutral busbars rated at 300 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity. OUTGOINGSi) 7 nos 80 amp 25kA FP MCCB with thermal magnetic protective releasesFEEDER PILLAR-4 (BLOCK-A) 58 INCOMER 1 no.-320amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR , Al three phase and neutral busbars rated at 400 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity. OUTGOINGSi) 9 nos 80 amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-5 (BLOCK-A) 59 INCOMER 1 no.-250amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 7 nos 80 amp 25kA FP MCCB with thermal magnetic protective releases 60 INCOMER 1 no.-250amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 7 nos 80 amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-3 (BLOCK-A) 61 INCOMER1 no.-320amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps. BUS BARAl three phase and neutral busbars rated at 400 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 9 nos 80 amp 25kA FP MCCB with thermal magnetic protective releases 62 INCOMER 1 no.-200 amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 13 nos 40amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-6A (BLOCK-A) 63 INCOMER 1 no.-200 amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR Al three phase and neutral busbars rated at 300 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGS i) 4 nos 63amp 25kA FP MCCB with thermal magnetic protective releases ii) 9 nos 40amp 10kA FP MCB with thermal magnetic protective releasesFEEDER PILLAR-7 (BLOCK-A) 64 INCOMER1 no.-100amps 25kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 200 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 13 nos 40amp 10kA FP MCB with thermal magnetic protective releasesFEEDER PILLAR-7A (BLOCK-A) 65 INCOMER1 no.-100amps 25kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps. BUS BARAl three phase and neutral busbars rated at 200 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 19 nos 32amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-7B (BLOCK-A) 66 INCOMER 1 no.-100amps 25kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR Al three phase and neutral busbars rated at 200 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 19 nos 32amp 10kA FP MCB with thermal magnetic protective releasesFEEDER PILLAR-10 (BLOCK-A) 67 INCOMER 1 no.-320amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR, Al three phase and neutral busbars rated at 400 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGS i) 8 nos 100amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-10A (BLOCK-A) 68 INCOMER 1 no.-320amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps. BUS BAR, Al three phase and neutral busbars rated at 400 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity. OUTGOINGS i) 8 nos 100amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-11 (BLOCK-A) 69 INCOMER 1 no.-250amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR, Al three phase and neutral busbars rated at 300 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 12 nos 40amp 10kA FP MCB with thermal magnetic protective releasesFEEDER PILLAR-11A (BLOCK-A) 70 INCOMER 1 no.-250amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR, Al three phase and neutral busbars rated at 300 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 14 nos 40amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-17 PARK-2 (BLOCK-B) 71 INCOMER 1 no.-63amps 25kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, Kwh ,RYB Indicating & ON/OFF lamps. BUS BAR, Al three phase and neutral busbars rated at 100 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGS i) 6 nos 20amp 10kA FP MCB with thermal magnetic protective releases , ii) 6 nos 32amp 10kA FP MCB with thermal magnetic protective releases , iii) 6 nos 20amp 10kA DP MCB with thermal magnetic protective releases ,iv) 6 nos 32amp 10kA DP MCB with thermal magnetic protective releases , FEEDER PILLAR-21 (BLOCK-B) 72 INCOMER 1 no.-200 amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGS i) 15 nos 32amp 10kA FP MCB with thermal magnetic protective releases ii) 10nos 40amp 10kA FP MCB with thermal magnetic protective releasesFEEDER PILLAR-22 (BLOCK-B) 73 INCOMER 1 no.-160amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR ., Al three phase and neutral busbars rated at 250 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 25nos 32amp 10kA FP MCB with thermal magnetic protective releases ,FEEDER PILLAR-22A (BLOCK-B) 74 INCOMER 1 no.-100amps 25kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR,Al three phase and neutral busbars rated at 200 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGS,i) 9 nos 40amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-23(BLOCK-B) 75 INCOMER 1 no.-160amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR, Al three phase and neutral busbars rated at 250 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 18 nos 40amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-23A (BLOCK-B) 76 INCOMER 1 no.-160amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR, Al three phase and neutral busbars rated at 250 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 18 nos 40amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-13 (BLOCK-B) 77 INCOMER 1 no.-125amps 25kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR ,Al three phase and neutral busbars rated at 200 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGS ,i) 20nos 32amp 10kA FP MCB with thermal magnetic protective releasesFEEDER PILLAR-14 (BLOCK-B) 78 INCOMER 1 no.-250amps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps. BUS BAR, Al three phase and neutral busbars rated at 300 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGS ,i) 35 nos 32amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-15 (BLOCK-B) 79 INCOMER 1 no.-250amps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR,Al three phase and neutral busbars rated at 300 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 35 nos 32amp 10kA FP MCB with thermal magnetic protective releasesFEEDER PILLAR-16 (BLOCK-B) 80 INCOMER 1 no.-320amps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR,Al three phase and neutral busbars rated at 400 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity. OUTGOINGS i) 43nos 32amp 10kA 4P MCB with thermal magnetic protective releasesFEEDER PILLAR-12 (BLOCK-B) 81 INCOMER1 no.-200amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR, Al three phase and neutral busbars rated at 300 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGS, i) 12nos 40amp 63kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-20 (BLOCK-B) 82 INCOMER1 no.-160amps 25kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR ,Al three phase and neutral busbars rated at 250 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 10nos 63amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-20A (BLOCK-B) 83 INCOMER 1 no.-125amps 25kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 250 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 15nos 40amp 10kA FP MCB with thermal magnetic protective releasesFEEDER PILLAR-12A (BLOCK-B) 84 INCOMER1 no.-160amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 250 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 17nos 40amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-18 (BLOCK-B) 85 INCOMER1 no.-250amps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 23nos 40amp 10kA FP MCB with thermal magnetic protective releasesFEEDER PILLAR-19 (BLOCK-B) 86 INCOMER1 no.-250amps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 13nos 40amp 10kA FP MCB with thermal magnetic protective releases ii) 9nos 63amp 10kA FP MCB with thermal magnetic protective releasesFEEDER PILLAR-24 (BLOCK-C) 87 INCOMER1 no.-250amps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 12 nos 63amp 25kA FP MCCB with thermal magnetic protective releasesFEEDER PILLAR-24A (BLOCK-C) 88 INCOMER 1 no.-250amps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR, Al three phase and neutral busbars rated at 300 amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGS, i) 12 nos 63amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-24B (BLOCK-C) 89 INCOMER 1 no.-200amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR,Al three phase and neutral busbars rated at 250amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity. OUTGOINGS i) 14nos 40amp 10kA FP MCB with thermal magnetic protective releasesFEEDER PILLAR-24C (BLOCK-C) 90 INCOMER 1 no.-200amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR,Al three phase and neutral busbars rated at 250amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity. i) 12nos 63amp 25kA FP MCCB with thermal magnetic protective releasesFEEDER PILLAR-27 (BLOCK-C) 91 INCOMER 1 no.-125amps 25kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps. BUS BAR, Al three phase and neutral busbars rated at 200amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGS,i) 15nos 40amp 10kA FP MCB with thermal magnetic protective releasesFEEDER PILLAR-28 (BLOCK-C) 92 INCOMER1 no.-125amps 25kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR, Al three phase and neutral busbars rated at 200amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGS, i) 15nos 40amp 10kA FP MCB with thermal magnetic protective releasesFEEDER PILLAR-25 (BLOCK-C) 93 INCOMER 1 no.-160amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR ,Al three phase and neutral busbars rated at 250amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 23nos 32amp 10kA FP MCB with thermal magnetic protective releasesFEEDER PILLAR-28B PARK-3 (BLOCK-C) 94 INCOMER1 no.-63amps 25kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, Kwh RYB Indicating & ON/OFF lamps.BUS BAR,Al three phase and neutral busbars rated at 100amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 6nos 20amp 10kA DP MCB with thermal magnetic protective releases ,ii) 6nos 32amp 10kA DP MCB with thermal magnetic protective releases , i) 6nos 20amp 10kA FP MCB with thermal magnetic protective releases , ii) 6nos 32amp 10kA FP MCB with thermal magnetic protective releases, FEEDER PILLAR-26 (BLOCK-C) 95 INCOMER 1 no.-160amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR,Al three phase and neutral busbars rated at 250amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGS,i) 11nos 40amp 10kA FP MCB with thermal magnetic protective releases , FEEDER PILLAR-26A (BLOCK-C) 96 INCOMER1 no.-160amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR,Al three phase and neutral busbars rated at 250amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGS,i) 11nos 40amp 10kA FP MCB with thermal magnetic protective releases ,FEEDER PILLAR-26B (BLOCK-C) 97 INCOMER , 1 no.-160amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR,Al three phase and neutral busbars rated at 250amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity. ,OUTGOINGS,i) 6nos 63amp 25kA FP MCCB with thermal magnetic protective releases , FEEDER PILLAR-26C (BLOCK-C) 98 INCOMER 1 no.-160amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR ,Al three phase and neutral busbars rated at 250amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGS,i) 8nos 63amp 25kA FP MCCB with thermal magnetic protective releases ,FEEDER PILLAR-25A (BLOCK-C) 99 INCOMER 1 no.-125amps 25kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR, Al three phase and neutral busbars rated at 200amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity., OUTGOINGS, i) 23nos 32amp 10kA FP MCB with thermal magnetic protective releases , FEEDER PILLAR-27A (BLOCK-C) 100 INCOMER , 1 no.-125amps 25kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps. BUS BAR , Al three phase and neutral busbars rated at 200amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity. ,OUTGOINGS, i) 17nos 40amp 10kA FP MCB with thermal magnetic protective releases , FEEDER PILLAR-28A (BLOCK-C) 101 INCOMER 1 no.-125amps 25kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR ,Al three phase and neutral busbars rated at 200amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGS,i) 17nos 40amp 10kA FP MCB with thermal magnetic protective releases , FEEDER PILLAR-29(BLOCK-C) 102 INCOMER 1 no.-200amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps. BUS BAR , Al three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity. ,OUTGOINGS, i) 17nos 40amp 10kA FP MCB with thermal magnetic protective releases , FEEDER PILLAR-29A (BLOCK-C) 103 INCOMER 1 no.-200amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps. BUS BAR, Al three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.,OUTGOINGS, i) 17nos 40amp 10kA FP MCB with thermal magnetic protective releases ,FEEDER PILLAR-30(BLOCK-C) 104 INCOMER 1 no.-250amps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR, l three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity., OUTGOINGS , i) 14nos 63amp 10kA FP MCB with thermal magnetic protective releases , FEEDER PILLAR-30A (BLOCK-C) 105 INCOMER 1 no.-250amps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps. , BUS BAR,Al three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.,OUTGOINGS, i) 14nos 63amp 10kA FP MCB with thermal magnetic protective releases , FEEDER PILLAR-47 (BLOCK-D) 106 INCOMER 1 no.-250amps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR,Al three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.,OUTGOINGS,i) 15nos 63amp 10kA FP MCB with thermal magnetic protective releases , FEEDER PILLAR-47A (BLOCK-D) 107 INCOMER 1 no.-250amps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGS i) 15nos 40amp 10kA FP MCB with thermal magnetic protective releases , FEEDER PILLAR-50 (BLOCK-D) 108 INCOMER 1 no.-200amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR,Al three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.,OUTGOINGS,i) 216nos 40amp 10kA FP MCB with thermal magnetic protective releases, FEEDER PILLAR-52 (BLOCK-D) 109 INCOMER 1 no.-160amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR,Al three phase and neutral busbars rated at 250amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity. .,OUTGOINGS ,i) 23nos 32amp 10kA FP MCB with thermal magnetic protective releases , EEDER PILLAR-48 (BLOCK-D) 110 INCOMER 1 no.-160amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps. BUS BAR, Al three phase and neutral busbars rated at 250amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity., OUTGOINGS,i) 23 nos 32amp 10kA FP MCB with thermal magnetic protective releases , FEEDER PILLAR-48A (BLOCK-D) 111 INCOMER 1 no.-160amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps., BUS BAR,Al three phase and neutral busbars rated at 250amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.,OUTGOINGS,i) 23 nos 32amp 10kA FP MCB with thermal magnetic protective releases , FEEDER PILLAR-49 (BLOCK-D) 112 INCOMER 1 no.-200amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR,Al three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity., OUTGOINGS,i) 16 nos 40amp 10kA FP MCB with thermal magnetic protective releases ,FEEDER PILLAR-49A (BLOCK-D) 113 INCOMER , 1 no.-200amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps. BUS BAR,Al three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.,OUTGOINGS , i) 16 nos 40amp 10kA FP MCB with thermal magnetic protective releases , FEEDER PILLAR-51 (BLOCK-D) 114 INCOMER 1 no.-200amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.,BUS BAR,Al three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.,OUTGOINGS,i) 15 nos 40amp 10kA FP MCB with thermal magnetic protective releases ,FEEDER PILLAR-51A (BLOCK-D) 115 INCOMER1 no.-200amps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR,Al three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.,OUTGOINGS, i) 16 nos 40amp 10kA FP MCB with thermal magnetic protective releases ,FEEDER PILLAR-53 (BLOCK-D) 116 INCOMER1 no.-250amps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR,Al three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity., OUTGOINGS, i) 15 nos 40amp 10kA FP MCB with thermal magnetic protective releases , FEEDER PILLAR-53A (BLOCK-D) 117 INCOMER 1 no.-250amps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR, Al three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.,OUTGOINGS, i) 15 nos 40amp 10kA FP MCB with thermal magnetic protective releases ,EDER PILLAR-54 (BLOCK-E) 118 INCOMER 1 no.-250amps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps. BUS BAR,Al three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity., OUTGOINGS, i) 13 nos 63amp 10kA FP MCB with thermal magnetic protective releases , FEEDER PILLAR-54A (BLOCK-E) 119 INCOMER 1 no.-250amps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps. BUS BAR , Al three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity. , OUTGOINGS,i) 14 nos 63amp 10kA FP MCB with thermal magnetic protective releases ,FEEDER PILLAR-55 (BLOCK-E) 120 INCOMER, 1 no.-250amps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps., BUS BAR,Al three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.,OUTGOINGS,i) 14 nos 63amp 10kA FP MCB with thermal magnetic protective releases ,FEEDER PILLAR-55A (BLOCK-E) 121 INCOMER 1 no.-250amps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps., BUS BAR,Al three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.,OUTGOINGS,i) 14 nos 63amp 10kA FP MCB with thermal magnetic protective releases ,FEEDER PILLAR-55A (BLOCK-E) 122 1 no.-250amps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps. 123 INCOMER 1 no.-250amps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR ,Al three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity., OUTGOINGS, i) 12 nos 63amp 25kA FP MCCB with thermal magnetic protective releases, FEEDER PILLAR-57 (BLOCK-E) 124 INCOMER 1 no.-160amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.,BUS BAR, Al three phase and neutral busbars rated at 250amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.,OUTGOINGS,i) 23 nos 32amp 10kA FP MCB with thermal magnetic protective releases , FEEDER PILLAR-57A (BLOCK-E) 125 INCOMER 1 no.-160amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BAR, Al three phase and neutral busbars rated at 250amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity., OUTGOINGSM, i) 23 nos 32amp 10kA FP MCB with thermal magnetic protective releasesFEEDER PILLAR-57B PARK-4 (BLOCK-E) 126 INCOMER 1 no.-63amps 25kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter,kwh meter, RYB Indicating & ON/OFF lamps., BUS BAR., Al three phase and neutral busbars rated at 100amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.,OUTGOINGSi) 6 nos 20amp 10kA DP MCB with thermal magnetic protective releases ii) 6 nos 32amp 10kA DP MCB with thermal magnetic protective releases iii) 6 nos 20 amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-58 (BLOCK-E) 127 INCOMER 1 no.-160amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter,kwh meter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 250amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity. OUTGOINGSi) 23 nos 32amp 10kA FP MCB with thermal magnetic protective releases , FEEDER PILLAR-60A (BLOCK-E) 128 INCOMER 1 no.-200amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter,kwh meter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 16 nos 40amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-58A (BLOCK-E) 129 INCOMER1 no.-160amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter,kwh meter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 250amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 23 nos 32amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-59 (BLOCK-E) 130 INCOMER 1 no.-160amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter,kwh meter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 250amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 23 nos 32amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-59A (BLOCK-E) 131 INCOMER 1 no.-160amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter,kwh meter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 250amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 23 nos 32amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-60 (BLOCK-E) 132 INCOMER 1 no.-160amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter,kwh meter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 250amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 23 nos 32amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-61 (BLOCK-E) 133 INCOMER 1 no.-250mps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter,RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 14nos 63amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-61A (BLOCK-E) 134 INCOMER 1 no.-250mps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter,RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 13nos 63amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-62 (BLOCK-E) 135 INCOMER 1 no.-250mps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter,RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 13nos 63amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-62A (BLOCK-E) 136 INCOMER 1 no.-250mps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter,RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 13nos 63amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-70 (BLOCK-F) 137 INCOMER1 no.-320amps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter,RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 400amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 10nos 100amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-70A (BLOCK-F) 138 INCOMER 1 no.-320amps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter,RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 400amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 10nos 100amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-71 (BLOCK-F) 139 INCOMER 1 no.-200amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter,RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 15nos 40amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-63 (BLOCK-F) 140 INCOMER1 no.-250amps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter,RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 10nos 63amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-63A (BLOCK-F) 141 INCOMER1 no.-250amps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter,RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 10nos 63amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-63B (BLOCK-F) 142 INCOMER1 no.-250amps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter,RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 10nos 63amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-63C (BLOCK-F) 143 INCOMER 1 no.-250amps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter,RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 10nos 63amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-64 (BLOCK-F) 144 INCOMER 1 no.-125amps 25kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter,RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 200amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 8nos 63amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-64A (BLOCK-F) 145 INCOMER 1 no.-125amps 25kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter,RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 200amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 8nos 63amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-71A (BLOCK-F) 146 INCOMER1 no.-125amps 25kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter,RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 200amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 8nos 63amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-71B (BLOCK-F) 147 INCOMER1 no.-125amps 25kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter,RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 200amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 8nos 63amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-69 (BLOCK-F) 148 INCOMER 1 no.-200amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter,RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi)9nos 63amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-69A (BLOCK-F) 149 INCOMER1 no.-200amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter,RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi)7nos 100amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-68 (BLOCK-F) 150 INCOMER 1 no.-200amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter,RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi)9nos 100amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-68A (BLOCK-F) 151 INCOMER 1 no.-250amps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter,RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi)8nos 100amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-68B PARK- (BLOCK-F) 152 INCOMER1 no.-63amps 25kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter,kwh meter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 100amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 6 nos 20amp 10kA DP MCB with thermal magnetic protective releases ii) 6 nos 32amp 10kA DP MCB with thermal magnetic protective releases iii) 6 nos 32 amp 10kA FP MCB with thermal magnetic protective releases iv) 6 nos 40 amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-67(BLOCK-F) 153 INCOMER 1 no.-250amps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter,RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 7 nos 100amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-67A(BLOCK-F) 154 INCOMER 1 no.-250amps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter,RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 7 nos 100amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-66(BLOCK-F) 155 INCOMER 1 no.-250amps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter,RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 7 nos 100amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-66A(BLOCK-F) 156 INCOMER 1 no.-250amps 36kA 415 volt 4P MCCB with Microprocessor Over loadandShortcircuit Release Complete with Ammeter,Voltmeter,RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 9 nos 100amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-65(BLOCK-F) 157 INCOMER1 no.-200amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter,RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi)7nos 100amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-65A (BLOCK-F) 158 INCOMER 1 no.-200amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter,RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi)7nos 100amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-65B (BLOCK-F) 159 INCOMER1 no.-200amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter,RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi)7nos 100amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-65C (BLOCK-F) 160 INCOMER1 no.-200amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter,RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi)7nos 100amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-42 (BLOCK-G) 161 INCOMER1 no.-250amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter,RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 8 nos 100amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-42A(BLOCK-G) 162 INCOMER 1 no.-250amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 8 nos 100amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-42B(BLOCK-G) 163 INCOMER 1 no.-250amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 8 nos 100amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-43B(BLOCK-G) 164 INCOMER 1 no.-160amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 250amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 6 nos 100amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-43A (BLOCK-G) 165 INCOMER1 no.-250amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 8 nos 100amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-43 (BLOCK-G) 166 INCOMER1 no.-250amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 8 nos 100amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-45B (BLOCK-G) 167 INCOMER1 no.-200amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 8 nos 63amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-45 (BLOCK-G) 168 INCOMER , 1 no.-160amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter,kwh meter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 250amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 14 nos 40amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-45A (BLOCK-G) 169 INCOMER 1 no.-160amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter,kwh meter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 250amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 14 nos 40amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-46 PARK (BLOCK-G) 170 INCOMER 1 no.-63amps 25kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter,kwh meter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 200amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 6nos 20amp 10kA DP MCB with thermal magnetic protective releases ii) 6nos 32amp 10kA DP MCB with thermal magnetic protective releases iii) 6nos 32amp 10kA FP MCB with thermal magnetic protective releases iv) 6nos 40amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-44 PARK-6 (BLOCK-G) 171 INCOMER 1 no.-63amps 25kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter,kwh meter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 200amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 6nos 20amp 10kA DP MCB with thermal magnetic protective releases ii) 6nos 32amp 10kA DP MCB with thermal magnetic protective releases iii) 6nos 32amp 10kA FP MCB with thermal magnetic protective releases iv) 6nos 40amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-31 (BLOCK-H) 172 INCOMER ,1 no.-320amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 400amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 12 nos 63amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-31A (BLOCK-H) 173 INCOMER 1 no.-320amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 400amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 12 nos 63amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-32A (BLOCK-H) 174 INCOMER 1 no.-320amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 400amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 12 nos 63amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-32 (BLOCK-H) 175 INCOMER, 1 no.-320amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 400amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 12 nos 63amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-33 (BLOCK-H) 176 INCOMER 1 no.-200amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 12 nos 63amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-33A (BLOCK-H) 177 INCOMER 1 no.-200amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 12 nos 63amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-34 (BLOCK-H) 178 INCOMER 1 no.-200amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 12 nos 63amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-37(BLOCK-H) 179 INCOMER1 no.-320amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 400amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 11 nos 63amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-37A(BLOCK-H) 180 INCOMER1 no.-200amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 13 nos 40amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-35(BLOCK-H) 181 INCOMER1 no.-160amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 250amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 12 nos 40amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-35A(BLOCK-H) 182 INCOMER 1 no.-160amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 250amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 12 nos 40amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-36(BLOCK-H) 183 INCOMER1 no.-320amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 400amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 8 nos 63amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-34A(BLOCK-H) 184 INCOMER 1 no.-200amps 25kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 12 nos 63amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-38(BLOCK-H) 185 INCOMER 1 no.-200amps 25kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 10 nos 63amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-38A(BLOCK-H) 186 INCOMER 1 no.-160amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 250amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 11 nos 63amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-39(BLOCK-H) 187 INCOMER, 1 no.-160amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 250amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 15 nos 40amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-39A(BLOCK-H) 188 INCOMER1 no.-160amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 250amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 15 nos 40amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-36A (BLOCK-H) 189 INCOMER 1 no.-200amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 7 nos 63amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-36B (BLOCK-H) 190 INCOMER 1 no.-125amps 25kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 200amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 6 nos 63amp 25kA FP MCCB with thermal magnetic protective releases FEEDER PILLAR-36C (BLOCK-H) 191 INCOMER1 no.-125amps 25kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 200amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 8 nos 40amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-40(BLOCK-H) 192 INCOMER 1 no.-250amps 36kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 300amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 15 nos 40amp 10kA FP MCB with thermal magnetic protective releases FEEDER PILLAR-41 (BLOCK-H) 193 INCOMER 1 no.-63amps 25kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter, kwh meter, RYB Indicating & ON/OFF lamps.BUS BARAl three phase and neutral busbars rated at 100amps having a minimum current density of 1.0 amp per sq mm. The neutral busbar is to be of 100% capacity.OUTGOINGSi) 6 nos 20amp 10kA DP MCB with thermal magnetic protective releases ii) 6 nos 32amp 10kA DP MCB with thermal magnetic protective releases iii) 6 nos 32amp 10kA FP MCB with thermal magnetic protective releases iv) 6 nos 40amp 10kA FP MCB with thermal magnetic protective releases Feeder Pillar foundations. All civil work for feeder pillar foundationas perapproved drawing including excavation, back filling, brick masonry work, plastering, PCC 1:2:4, PVC sleeves in brick masonry foundation for cables, removal of surplus earth work(Soil) within lead of 50m complete including grouting of feeder pillar frame work in masonry foundationfeeder pillar foundation shall be minimum 450mm above sounding ground level finish level complete as required. 194 3.5Cx300 sq.mm ,LT CABLES Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armouredaluminiumcable of 1.1 KV grade as per PWD specification for electrical Worksin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size andas per points (a), (b), (c), mentioned below:- (a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I(b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures .(c)OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities forcables . Appropriate type test certificate / OEM test report shall be submitted .All above as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 195 3.5Cx240 sq.mmProviding & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armouredaluminiumcable of 1.1 KV grade as per PWD specification for electrical Worksin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size andas per points (a), (b), (c), mentioned below:- (a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I(b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures .(c)OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities forcables . Appropriate type test certificate / OEM test report shall be submitted .All above as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 196 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armouredaluminiumcable of 1.1 KV grade as per PWD specification for electrical Worksin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size andas per points (a), (b), (c), mentioned below:- (a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I(b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures .(c)OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities forcables . Appropriate type test certificate / OEM test report shall be submitted .All above as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 3.5Cx185 sq.mm 197 3.5Cx150 sq.mm Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armouredaluminiumcable of 1.1 KV grade as per PWD specification for electrical Worksin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size andas per points (a), (b), (c), mentioned below:- (a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I(b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures .(c)OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities forcables . Appropriate type test certificate / OEM test report shall be submitted .All above as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 198 3.5Cx120 sq.mm Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armouredaluminiumcable of 1.1 KV grade as per PWD specification for electrical Worksin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size andas per points (a), (b), (c), mentioned below:- (a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I(b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures .(c)OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities forcables . Appropriate type test certificate / OEM test report shall be submitted .All above as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 199 3.5Cx95 sq.mmProviding & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armouredaluminiumcable of 1.1 KV grade as per PWD specification for electrical Worksin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size andas per points (a), (b), (c), mentioned below:- (a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I(b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures .(c)OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities forcables . Appropriate type test certificate / OEM test report shall be submitted .All above as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 200 3.5Cx70 sq.mm Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armouredaluminiumcable of 1.1 KV grade as per PWD specification for electrical Worksin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size andas per points (a), (b), (c), mentioned below:- (a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I(b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures .(c)OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities forcables . Appropriate type test certificate / OEM test report shall be submitted .All above as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 201 3.5Cx50 sq.mm Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armouredaluminiumcable of 1.1 KV grade as per PWD specification for electrical Worksin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size andas per points (a), (b), (c), mentioned below:- (a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I(b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures .(c)OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities forcables . Appropriate type test certificate / OEM test report shall be submitted .All above as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 202 4Cx16 sq.mmProviding & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armouredaluminiumcable of 1.1 KV grade as per PWD specification for electrical Worksin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size andas per points (a), (b), (c), mentioned below:- (a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I(b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures .(c)OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities forcables . Appropriate type test certificate / OEM test report shall be submitted .All above as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 203 4Cx10 sq.mmProviding & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armouredaluminiumcable of 1.1 KV grade as per PWD specification for electrical Worksin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size andas per points (a), (b), (c), mentioned below:- (a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I(b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures .(c)OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities forcables . Appropriate type test certificate / OEM test report shall be submitted .All above as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 204 3.5Cx300 sq.mm Cable End Termination :Supplying and making one end termination with heavy duty single compression brass gland (as per IS 12943- 1990) SIBG type, heavy duty Copper/ Bimetallic lugs (IS 8337- 1976) duly crimped with crimping tool, PVC tapeas per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium/copper conductor cable of 1100 volt grade as required of size. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 205 3.5Cx240 sq.mmCable End Termination :Supplying and making one end termination with heavy duty single compression brass gland (as per IS 12943- 1990) SIBG type, heavy duty Copper/ Bimetallic lugs (IS 8337- 1976) duly crimped with crimping tool, PVC tapeas per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium/copper conductor cable of 1100 volt grade as required of size. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 206 3.5Cx185 sq.mmCable End Termination :Supplying and making one end termination with heavy duty single compression brass gland (as per IS 12943- 1990) SIBG type, heavy duty Copper/ Bimetallic lugs (IS 8337- 1976) duly crimped with crimping tool, PVC tapeas per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium/copper conductor cable of 1100 volt grade as required of size. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 207 3.5Cx150 sq.mmCable End Termination :Supplying and making one end termination with heavy duty single compression brass gland (as per IS 12943- 1990) SIBG type, heavy duty Copper/ Bimetallic lugs (IS 8337- 1976) duly crimped with crimping tool, PVC tapeas per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium/copper conductor cable of 1100 volt grade as required of size. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 208 3.5Cx120 sq.mmCable End Termination :Supplying and making one end termination with heavy duty single compression brass gland (as per IS 12943- 1990) SIBG type, heavy duty Copper/ Bimetallic lugs (IS 8337- 1976) duly crimped with crimping tool, PVC tapeas per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium/copper conductor cable of 1100 volt grade as required of size. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 209 3.5Cx95 sq.mm Cable End Termination :Supplying and making one end termination with heavy duty single compression brass gland (as per IS 12943- 1990) SIBG type, heavy duty Copper/ Bimetallic lugs (IS 8337- 1976) duly crimped with crimping tool, PVC tapeas per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium/copper conductor cable of 1100 volt grade as required of size. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 210 3.5Cx70 sq.mm Cable End Termination :Supplying and making one end termination with heavy duty single compression brass gland (as per IS 12943- 1990) SIBG type, heavy duty Copper/ Bimetallic lugs (IS 8337- 1976) duly crimped with crimping tool, PVC tapeas per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium/copper conductor cable of 1100 volt grade as required of size. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 211 3.5Cx50 sq.mm Cable End Termination :Supplying and making one end termination with heavy duty single compression brass gland (as per IS 12943- 1990) SIBG type, heavy duty Copper/ Bimetallic lugs (IS 8337- 1976) duly crimped with crimping tool, PVC tapeas per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium/copper conductor cable of 1100 volt grade as required of size. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 212 4Cx16 sq.mmCable End Termination :Supplying and making one end termination with heavy duty single compression brass gland (as per IS 12943- 1990) SIBG type, heavy duty Copper/ Bimetallic lugs (IS 8337- 1976) duly crimped with crimping tool, PVC tapeas per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium/copper conductor cable of 1100 volt grade as required of size. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 213 4Cx10 sq.mm Cable End Termination :Supplying and making one end termination with heavy duty single compression brass gland (as per IS 12943- 1990) SIBG type, heavy duty Copper/ Bimetallic lugs (IS 8337- 1976) duly crimped with crimping tool, PVC tapeas per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium/copper conductor cable of 1100 volt grade as required of size. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 214 Providing & Laying of 25 cm thick layer of river sandto cover of existing cable in 30cmx75cm size cabletrench with levelling and making symmetric 25 mmthick layer in complete running length of trench asrequired. Mtr 54.00 215 Providing & covering of existing cable lying inexisting trench by IInd class bricks/ Stone slab of minimum 32mm thick and 250 mm wide in completerunning length of trench complete as required.Mtr 44.00 216 Labour charges for Excavation of 30cmx75cm sizetrench in loose soil including refilling of excavatedearth,compaction of earth, making good the samecomplete as required . Mtr 59.00 217 Laying Charges for cable through Vermeer machineby making pit at regular interval and repairing the pitafter laying of cable with PCC/ Bitumin as required.Mtr 263.00 218 HT CABLES & TERMINATION Providing & Laying XLPE insulated as per IS:7098/II/85H.T.cable as per PWD specification for electrical Works for working voltage 11 K.V.(E) in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size as per points (a), (b), (c) mentioned below:- (a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I(b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999for armouring of cables , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures (c)OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities forcables .All above as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 3 core 300.0 Sq.mm 219 3 core 300.0 Sq.mm , Laying Charges for cable through Vermeer machineby making pit at regular interval and repairing the pitafter laying of cable with PCC/ Bitumin as required.Mtr 263.00Page 8Chapter E-11Providing & Laying XLPE insulated IS:7098/II/85 of Group1 and approved make H.T.cable for working voltage 33K.V.Earthed direct in ground including excavation of 30cmx120cm size trench, 25cmlayer of river sand, IInd class bricks covering, refilling earth, compaction of earth, making necessary connection testing etc.as required of size. 220 3 core 300 Sq.mmHT CABLESTERMINATIONProviding & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit as per PWD specification for electrical Works suitable for11 KV / 33 KV cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for straightthrough joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Crosslinking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. OEM test lab should be as per ISO 9001:2015 & 14001 : 2015 & reports submitted to engineer in charge includingtesting etc. as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 221 3 core 300 Sq.mmHT CABLESTERMINATIONProviding & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kit as per PWD specification for electrical Works suitable for11 KV / 33 KV cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for straightthrough joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Crosslinking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. OEM test lab should be as per ISO 9001:2015 & 14001 : 2015 & reports submitted to engineer in charge includingtesting etc. as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 222 Providing & Laying of 25 cm thick layer of river sand tocover of existing cable in 30 cm x 100/ 120 cm size cabletrench with levelling and making symmetric 25 mm thicklayer in complete running length of trench as required.Mtr 54.00 223 Providing & covering of existing cable lying in existingtrench by IInd class bricks/ Stone slab of minimum32mm thick and 250 mm wide in complete runninglength of trench complete as required.Mtr 44.00 224 Labour charges for Excavation of 30cmx100cm size loosesoil trench including refilling of excavatedearth,compaction of earth, making good the samecomplete as required . Mtr79. 225 Labour charges for Excavation of 30cmx120cm size loosesoil trench including refilling of excavatedearth,compaction of earth, making good the samecomplete as required . Mtr95. 226 Labour charges for cable through Vermeer machine bymaking pit at regular interval and repairing the pit afterlaying of cable with PCC/ Bitumin as required.Mtr 263 227 EARTHING FOR SUB-STATION EQUIPMENT Pipe Earthing as per PWD specification for electrical Works as per IS:3043-1987 with 3.0Mtr. Long, 40mmdia. Bclass G.I.Pipe IS:1239 (Part-1) 2004, Equivalent to BS:1387 with perforated holes of 12mm dia, including all accessories like nut, bolts, reducer, nipple, wiremeshed funnel, and Heavy duty weather proof poly-propy lene earthpit chamber with lockable Jam free lid suitable for safe working load 5000Kg or more of size Top Dia. 225to260mm, Bottom Dia300 to 350mm. and Height 250 to300mm. and embodying the pipe complete with alternate layers salt and coke/charcoal, testing of earth resistance for value of 5ohms or less as required & mustrecord by engineer incharge during site visit and ensure to enter in measurement book. All as per preapproved by Engineer in charge. For additional technical parameters of products/work , refer Annexure A attached with this BSR . 228 EARTHING FOR SUB-STATION EQUIPMENT Plate Earthing as per PWD specification for electrical Works as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurement book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 229 Plate Earthing as per PWD specification for electrical Works as per IS:3043 withcopper Earth plate of size 600mm x 600mm x 3.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurement book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 230 50mm x 6mm copper strip, Supply & Laying following size earth stripin horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 231 50mm x 6mm GI, Supply & Laying following size earth stripin horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 232 25mm x 6mm GI Strip , Supply & Laying following size earth stripin horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 233 8 SWG GI WIRE, Supply & Laying following size earth stripin horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 234 50 mm dia.Supply & Laying following size B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc.for laying earth conductor/ strip / cable in ground/ surface/ recess as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 235 65 mm dia.Supply & Laying following size B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc.for laying earth conductor/ strip / cable in ground/ surface/ recess as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 236 80 mm dia.Supply & Laying following size B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc.for laying earth conductor/ strip / cable in ground/ surface/ recess as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 237 100 mm dia.Supply & Laying following size B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc.for laying earth conductor/ strip / cable in ground/ surface/ recess as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 238 125 mm dia.Supply & Laying following size B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc.for laying earth conductor/ strip / cable in ground/ surface/ recess as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 239 LED Street Light fixture 70 Watt EXTERNAL LIGHTINGWORK, STREET LIGHT FIXTUERSProviding & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wtwith High Power LEDs is to be usedand potted driver must be potted & has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <1000mA shown in LM79 report. The luminaireshall be BIS certified and T.C. certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened ,color Rendering Index >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 240 LED Street Light fixture 90 WattEXTERNAL LIGHTINGWORK, STREET LIGHT FIXTUERSProviding & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wtwith High Power LEDs is to be usedand potted driver must be potted & has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <1000mA shown in LM79 report. The luminaireshall be BIS certified and T.C. certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened ,color Rendering Index >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 241 4 Mtr.PolesSupply and erection of M.S. Galvanized Octagonal pole ( as per BSEN 40-3-3:2003 /BSEN 10025/IS 2062 IS:875 Part-1 – 2015/ for MS plate for baseflange )of following length and dimension as per table P-01 with base plate on the cement concrete foundation of M-20 grade (1:1.5:3) as perIS 456/IS 2911. with the help of anchor bolts of grade 6.8 (IS: 1367 P III ).The pole shall have a weatherproof flush door and locking arrangements. complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Octagonal MS Polesmade of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629. 242 8 Mtr. PolesSupply and erection of M.S. Galvanized Octagonal pole ( as per BSEN 40-3-3:2003 /BSEN 10025/IS 2062 IS:875 Part-1 – 2015/ for MS plate for baseflange )of following length and dimension as per table P-01 with base plate on the cement concrete foundation of M-20 grade (1:1.5:3) as perIS 456/IS 2911. with the help of anchor bolts of grade 6.8 (IS: 1367 P III ).The pole shall have a weatherproof flush door and locking arrangements. complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Octagonal MS Polesmade of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629. 243 Single arm overhang Supply, Erection and Fixing of hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 244 Providing & Fixing of thermoplastic Polycarbonate cable junction boxes with IP66 rating of protection & knock out for cable entry/out of following sizesincluding clamps for holding the box, including cost ofDIN rail for MCB mounting, 10 Sqmm 4 pole connectors for cables terminals, threaded cable glands made of polyamide material etc. complete in allrespect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work , refer Annexure A attached with this BSR .300mm X 200mm X125mm 245 The EXT. LIGHTING FEEDER PILLAR shall be complete with all interconnections, labels wiring, etc as required EXTERNAL STREET LIGHTING FEEDER PILLAR 1 (TYPICAL FOR FEEDER PILLAR 2 TO FEEDER PILLAR 8) (OUTDOOR TYPE IP-55) INCOMER1 no.- 63 amps 25kA 415 volt 4P MCCB with Thermal Over loadand Magnetic Shortcircuit Release Complete with Ammeter,Voltmeter and KWH meter, RYB Indicating lamps, On /Offlamp and with 63 4P amp Contactorwith Dual setting 24 hour calibrated time switch for automatic operationBUS BARAlu three phase and neutral busbars rated at 100 amps having a minimum current density of 1.0 amp per sq mm . The neutral busbar is to be of 100% capacity.OUTGOINGSi) 5 nos 32 amp 10 kA DP MCB with thermal magnetic protective releases ii) 5 nos 20 amp 10 kA DP MCB with thermal magnetic protective releases 246 Brick masonry Foundation for Feeder pillar minimum 450mm above ground with excavation, backfill, 230mm brick work, plaster, PVC sleeves etc complete including disposal of surplus earth with as requied. 247 4Cx16 sq.mm, Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armouredaluminiumcable of 1.1 KV grade as per PWD specification for electrical Worksin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size andas per points (a), (b), (c), mentioned below:- (a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I(b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures .(c)OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities forcables . Appropriate type test certificate / OEM test report shall be submitted .All above as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 248 4Cx10 sq.mm, Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armouredaluminiumcable of 1.1 KV grade as per PWD specification for electrical Worksin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size andas per points (a), (b), (c), mentioned below:- (a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I(b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures .(c)OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities forcables . Appropriate type test certificate / OEM test report shall be submitted .All above as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 249 Providing & Fixing of ISO certified company made IK10 IP65 protectedTop/Bottom mounted LED Post top Light system. Fixture made of powder coated die cast alluminium housing with UV stabalized PCdiffuser. The System level Luminous efficacy≥ 90 Lumen/W. SMDLEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. Theintegral electronic driver must be potted & has a unique BIS R numbermust be potted & has a unique BIS R number constant current andInternal/external surge protection device of min. 4KV(L-N) andefficiency > 85%, PF>0.9, THD<20% and input Voltage range of 90-270V AC at 50Hz. System life of 30000 Burning hours with 70% of Initial Lumens maintained Light output in Cool white or Warm WhiteColour as per engineers choice. driver current <1000mA shown inLM79 report. Fixture must be in compliance with BIS Standards andT.C . Certificate complete in all respect.OEM Must have its own inhouse NABL lab setup for all testing facilities for LED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per preapproved by Engineer in charge. For additional technical parametersof products/ work , refer Annexure A attached with this BSR45 W LED Post Top Fixture 250 2Cx6 sq.mmSupplying and making one end termination with heavy duty single compression brass gland (as per IS 12943- 1990) SIBG type, heavy duty Copper/ Bimetallic lugs (IS 8337- 1976) duly crimped with crimping tool, PVC tapeas per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium/copper conductor cable of 1100 volt grade as required of size. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 251 2Cx10sq.mmSupplying and making one end termination with heavy duty single compression brass gland (as per IS 12943- 1990) SIBG type, heavy duty Copper/ Bimetallic lugs (IS 8337- 1976) duly crimped with crimping tool, PVC tapeas per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium/copper conductor cable of 1100 volt grade as required of size. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 252 Pipe Earthing as per PWD specification for electrical Works as per IS:3043-1987 with 3.0Mtr. Long, 40mmdia. Bclass G.I.Pipe IS:1239 (Part-1) 2004, Equivalent to BS:1387 with perforated holes of 12mm dia, including all accessories like nut, bolts, reducer, nipple, wiremeshed funnel, and Heavy duty weather proof poly-propy lene earthpit chamber with lockable Jam free lid suitable for safe working load 5000Kg or more of size Top Dia. 225to260mm, Bottom Dia300 to 350mm. and Height 250 to300mm. and embodying the pipe complete with alternate layers salt and coke/charcoal, testing of earth resistance for value of 5ohms or less as required & mustrecord by engineer incharge during site visit and ensure to enter in measurement book. All as per preapproved by Engineer in charge. Foradditional technical parameters of products/work , refer Annexure A attached with this BSR . 253 25mm x 6mm GI Strip ,Supply & Laying following size earth stripin horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 254 8 SWG GI WIRE, Supply & Laying following size earth stripin horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 255 50 mm dia., Supply & Laying following size B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 (2004 ) with accessories like bend, socket etc.for laying earth conductor/ strip / cable in ground/ surface/ recess as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 256 65 mm dia., Supply & Laying following size B class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 (2004 ) with accessories like bend, socket etc.for laying earth conductor/ strip / cable in ground/ surface/ recess as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 257 3.5Cx50 sq.mm , SERVICES CONNECTION (CABLES) TO INDIVIDUL PLOTProviding & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armouredaluminiumcable of 1.1 KV grade as per PWD specification for electrical Worksin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size andas per points (a), (b), (c), mentioned below:- (a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I(b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures .(c)OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities forcables . Appropriate type test certificate / OEM test report shall be submitted .All above as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 258 4Cx25 sq.mm , SERVICES CONNECTION (CABLES) TO INDIVIDUL PLOTProviding & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armouredaluminiumcable of 1.1 KV grade as per PWD specification for electrical Worksin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size andas per points (a), (b), (c), mentioned below:- (a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I(b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures .(c)OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities forcables . Appropriate type test certificate / OEM test report shall be submitted .All above as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 259 4Cx16 sq.mmSERVICES CONNECTION (CABLES) TO INDIVIDUL PLOTProviding & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armouredaluminiumcable of 1.1 KV grade as per PWD specification for electrical Worksin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size andas per points (a), (b), (c), mentioned below:- (a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I(b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures .(c)OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities forcables . Appropriate type test certificate / OEM test report shall be submitted .All above as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 260 4Cx10 sq.mm SERVICES CONNECTION (CABLES) TO INDIVIDUL PLOTProviding & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armouredaluminiumcable of 1.1 KV grade as per PWD specification for electrical Worksin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size andas per points (a), (b), (c), mentioned below:- (a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I(b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures .(c)OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities forcables . Appropriate type test certificate / OEM test report shall be submitted .All above as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 261 2Cx10 sq.mm , SERVICES CONNECTION (CABLES) TO INDIVIDUL PLOTProviding & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armouredaluminiumcable of 1.1 KV grade as per PWD specification for electrical Worksin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size andas per points (a), (b), (c), mentioned below:- (a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I(b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures .(c)OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities forcables . Appropriate type test certificate / OEM test report shall be submitted .All above as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 262 2Cx6 sq.mm , SERVICES CONNECTION (CABLES) TO INDIVIDUL PLOTProviding & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured / Armouredaluminiumcable of 1.1 KV grade as per PWD specification for electrical Worksin existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench with filling of excavated earth in trench, on existing cable trays or on surface etc.including making necessary connection, testing etc. as required of size andas per points (a), (b), (c), mentioned below:- (a) Material :- H4- Gradealuminium conductor of purity >99.6 %& as perIS:1554 P-I / IS :7098 P - I(b) conductor shall have electrolytic aluminium confirming to IS 8130, IS 3975-1999for armouring of cables in armoured cable items , IS 5831 for sheath, IS 10810 (Part 0 to 64 ) for testing procedures .(c)OEM Must have ISO 9001 & 14001 certifications for quality assuarance & its own in house NABL lab setup for all testing facilities forcables . Appropriate type test certificate / OEM test report shall be submitted .All above as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 263 3.5Cx50 sq.mm Cable End Termination : Supplying and making one end termination with heavy duty single compression brass gland (as per IS 12943- 1990) SIBG type, heavy duty Copper/ Bimetallic lugs (IS 8337- 1976) duly crimped with crimping tool, PVC tapeas per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium/copper conductor cable of 1100 volt grade as required of size. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 264 4Cx25 sq.mm Cable End Termination : Supplying and making one end termination with heavy duty single compression brass gland (as per IS 12943- 1990) SIBG type, heavy duty Copper/ Bimetallic lugs (IS 8337- 1976) duly crimped with crimping tool, PVC tapeas per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium/copper conductor cable of 1100 volt grade as required of size. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 265 4Cx16 sq.mmCable End Termination : Supplying and making one end termination with heavy duty single compression brass gland (as per IS 12943- 1990) SIBG type, heavy duty Copper/ Bimetallic lugs (IS 8337- 1976) duly crimped with crimping tool, PVC tapeas per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium/copper conductor cable of 1100 volt grade as required of size. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 266 4Cx10 sq.mmCable End Termination : Supplying and making one end termination with heavy duty single compression brass gland (as per IS 12943- 1990) SIBG type, heavy duty Copper/ Bimetallic lugs (IS 8337- 1976) duly crimped with crimping tool, PVC tapeas per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium/copper conductor cable of 1100 volt grade as required of size. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 267 2Cx10 sq.mmCable End Termination : Supplying and making one end termination with heavy duty single compression brass gland (as per IS 12943- 1990) SIBG type, heavy duty Copper/ Bimetallic lugs (IS 8337- 1976) duly crimped with crimping tool, PVC tapeas per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium/copper conductor cable of 1100 volt grade as required of size. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 268 2Cx6 sq.mmCable End Termination : Supplying and making one end termination with heavy duty single compression brass gland (as per IS 12943- 1990) SIBG type, heavy duty Copper/ Bimetallic lugs (IS 8337- 1976) duly crimped with crimping tool, PVC tapeas per PWD specification for electrical Works etc for following size of Armoured PVC insulated & PVC sheathed/ XLPE aluminium/copper conductor cable of 1100 volt grade as required of size. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .

Key Value

Document Fees
INR 2500 /-
EMD
INR 5166000.0 /-
Tender Value
INR 25.83 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail