Finalization Of Rate Contract For The Procurement Of diagnostic & Therapeutic Items For Cardiac Cath Lab For The Year 2025-27 Group-“A” , Fda Approved 1.5& 3T Whole Body Mri Compatible Single Chamber Rate Responsive Pacemaker (Vvir Mode) Fully Automatic With Capture Management And Sensitivity Management For Rv With Standard Warranty & With 7 Fr. Compatible Passive Fixation Tined Leads Or Screw-In Leads & Lead Introducers , Fda Approved 1.5& 3T Whole Body Mri Compatible Single Chamber Rate Responsive Pacemaker (Vvir Mode+ Remote Monitor) Fully Automatic With Capture Management And Sensitivity Management For Rv With Lifetime Warranty & With 7 Fr. Compatible Passive Fixation Tined Leads Or Screw-In Leads & Lead Introducers , Fda Approved 1.5& 3T Whole Body Mri Compatible Single Chamber Rate Responsive Pacemaker (Vvir Mode+ Pfl) Fully Automatic With Capture Management And Sensitivity Management For Rv With Standard Warranty & Remote Monitoring Device &With 7 Fr. Compatible Passive Fixation Tined Leads Or Screw-In Leads & Lead Introducers , Fda Approved Digital Multi-Programmable Dual Chamber Pacemaker With Lifetime Warranty 1.5& 3T Whole Body Mri Compatible Dddr Pacemaker (Dddr Mode+ Pfl) Fully Automatic With Capture Management And Sensitivity Management For Both Ra And Rv & Proven Extended Longevity Of > 10 Years With 100% Pacing Of Ra And Rv, With Advanced Features Like: 1. Mode Based Reduction In Rv Pacing Or Equivalent. 2. Rate Drop Response Or Equivalent & 3. +Af Detection And Prevention Algorithm & With 7 Fr. Compatible Passive-Fixation Tined Leads Or Screw-In Leads & Lead Introducers. , Fda Approved Digital Multi-Programmable Dual Chamber Pacemaker With Standard Warranty 1.5& 3T Whole Body Mri Compatible Dddr Pacemaker (Dddr Mode+ Remote Monitor) Fully Automatic With Capture Management And Sensitivity Management For Both Ra And Rv & Proven Extended Longevity Of > 10 Years With 100% Pacing Of Ra And Rv With 7 Fr. Compatible Passive-Fixation Tined Leads Or Screw-In Leads & Lead Introducers & With Remote Monitoring Device , Ce Approved Digital Multi-Programmable Dual Chamber Pacemaker With Lifetime Warranty, 1.5 T And 3Rfull Body Mri Compatible Dddr Pacemaker (Dddr + Pfl+Lbbap) Fully Automatic With Capture Management & Sensitivity Management For Both Ra & Rv And Proven Extended Longevity Of > 10 Years With 100% Pacing Of Ra & Rv, With Advanced Features Like: 1. Mode Based Reduction In Rv Pacing Or Equivalent, 2. Rate Drop Response Or Equivalent. 3. Af Detection And Prevention Algorithm, & With 7 Fr. Compatible Passive-Fixation Tined Leads Or Screw-In Leads & Lead Introducers Along With Lbbap Set. , Fda Approved Digital Multi-Programmable Dual Chamber Pacemaker With Lifetime Warranty 1.5& 3T Fullbody Mri Compatible Dddr Pacemaker (Dddr Mode+ Pfl+Lbbap) Fully Automatic With Capture Management And Sensitivity Management For Both Ra And Rv & Proven Extended Longevity Of > 10 Years With 100% Pacing Of Ra And Rv, With Advanced Features Like: 1. Mode Based Reduction In Rv Pacingor Equivalent. 2. Rate Drop Response Or Equivalent & Af Detection And Prevention Algorithm & With 7 Fr. Compatible Passive-Fixation Tined Leads Or Screw-In Leads & Lead Introducers Along With Lbbap Set. , Fda Approved Single Chamber Icd (Sc-Icd) With All Basic Programmable Parameters, 1.5 T And 3T Full Body Mri Compatible With All Lead Combinations, With Features Like: 1. Must Have Svt Discrimination In Vf Zone. 2. Must Have Atp During And Before Charging In Vf Zone. 3. Must Have Independently Programmable Shock Vector For Each Therapy. 4. Must Have Morphological Based Svt Discrimation. 5. Must Have Remote Patient Management Capability. All Lead Combinations To Be Made Available With Option Of Programming True-Bi-Polar And Integrated Bi-Polar Configuration. , Fda Approved Single Chamber Icd (Sc-Icd) With Advanced Features And Extended Longevity) With All Basic Programmable Parameters, 1.5 T And 3T Full Body Mri Compatible With All Lead Combinations, With Features Like: 1. Must Have Svt Discrimination In Vf Zone. 2. Must Have Atp During And Before Charging In Vf Zone. 3. Must Have Independently Programmable Shock Vector For Each Therapy. 4. Must Have Morphological Based Svt Discrimination. 5. Must Have Atrial Arrhythmia Monitoringcapabilites. 6. Must Have Proven Extended Longevity. 7. Must Have Remote Patient Management Capability. All Lead Combinations To Be Made Available With Option Of Programming True-Bi-Polar And Integrated Bi-Polar Configuration. , Fda Approved Dual Chamber Icd (Dc-Icd) With All Basic Programmable Parameters, 1.5T And 3T Full Body Mri Compatible With All Lead Combinations, With Features Like: 1. Must Have Svt Discrimination In Vf Zone. 2. Must Have Atp During And Before Charging In Vf Zone. 3. Must Have Independently Programmable Shock Vector For Each Therapy. 4. Must Have Morphological Based Svt Discrimination. 5. Must Have Remote Patient Management Capability. All Lead Combinations To Be Made Available With Option Of Programmingtrue Bi-Polar And Integrated Bi-Polar Configuration. , Fda Approved Dual Chamber Icd (Dc-Icd With Advance Features And Extended Longevity) With All Basic Programmable Parameters, 1.5T And 3T Full Body Mri Compatible With All Lead Combinations, With Features Like: 1. Must Have Svt Discrimination In Vf Zone. 2. Must Have Atp During And Before Charging In Vf Zone. 3. Must Have Independently Programmable Shock Vector For Each Therapy. 4. Must Have Morphological Based Svt Discrimination. 5. Must Have Atrial Pacing To Overcome At/Af Management. 6. Must Have Proven Extended Longevity. 7. Must Have Remote Patient Management Capability. All Lead Combinations To Be Made Available With Option Of Programmingtrue Bi-Polar And Integrated Bi-Polar Configuration. , Fda Approved Crt-P (Quadripolar) With All Basic Programmable Parameters, 1.5 T & 3T Full Body Mri Compatible With All Lead Combinations; Pacemaker Fully Automatic With Capture Management & Sensitivity Management For Ra, Rv & Lv Lead Amplitude, Pulse Width And Vv Delay. Must Have Pacing In The Atrial Channel For Af Management. All Types Of Lv Leads And Lv Lead Compatible Guidewires And Other Accessories (One Complete Set). Must Have Remote Patient Management Capability. , Fda Approved Advanced Crt-P (Quadripolar) With Extra Longevity, With All Basic Programmable Parameters, 1.5 T & 3T Full Body Mri Compatible With All Lead Combinations; Pacemaker Fully Automatic With Capture Management & Sensitivity Management For Ra, Rv & Lv; Must Have Autoadjusting Av & Vv Delay Capabilities; Must Have Separate Programmable Ra, Rv &; Lv Lead Amplitude, Pulse Width And Vv Delay. Must Have Pacing In The Atrial Channel For Af Management. All Types Of Lv Leads And Lv Lead Sheaths To Be Made Available Along With Compatible Guide Wires And Other Accessories (One Complete Set). Must Have Proven Extended Longevity. Must Have Remote Patient Management Capability. , Fda Approved Crt-P (Quadripolar) With All Basic Programmable Parameters, 1.5 T & 3T Full Body Mri Compatible With All Lead Combinations; Pacemaker Fully Automatic With Capture Management & Sensitivity Management For Ra, Rv & Lv; Must Have Separate Programmable Ra, Rv & Lv Lead Amplitude, Pulse Width And Vv Delay. Must Have Atp Before & During Charging In Vf Zone. Must Have Independently Programmable Shock Vector For Each Therapy. Must Havepacing In The Atrial Channel For Af Management. Must Have Morphological Based Svt Discrimination With Option Of Programming True Bi-Polar & Integrated Bi-Polar Configuration. All Types Of Lv Leads And Lv Lead Sheaths To Be Made Available Along With Compatible Guide Wires And Other Accessories (One Complete Set). Must Have Remote Patient Management Capability. , Fda Approved Crt-P (Quadripolar) With Extended Longevity With All Basic Programmable Parameters, 1.5 T & 3T Full Body Mri Compatible With All Lead Combinations With Advanced Features For Optimizing Av & Vv Delays Automatically, Multiple Point Pacing; Must Have Minimum 14 Programmable Vectors. Pacemaker Fully Automatic With Capture Management & Sensitivity Management For Ra, Rv & Lv; Must Have Separate Programmable Ra, Rv & Lv Lead Amplitude, Pulse Width And Vv Delay. Must Have Svt Discrimination In Vf Zone. Must Have Atp Before & During Charging In Vf Zone. Must Have Independently Programmable Shock Vector For Each Therapy. Must Havepacing In The Atrial Channel For Af Management. Must Have Morphological Based Svt Discrimination With Option Of Programming True Bi-Polar & Integrated Bi-Polar Configuration. All Types Of Lv Leads And Lv Lead Sheaths To Be Made Available Along With Compatible Guide Wires And Other Accessories (One Complete Set). Must Have Remote Patient Management Capability. , Fda Approved Full Body 1.5 T Mri Compatible Biventricular Pacemaker With Bipolar Endocardial/ Epicardial Lv Lead , Fda Approved Special Leadless Pacemaker For Av Synchronous Pacing Along With Delivery System , Fda Approved Special Single Chamber Rate Responsive Pacemaker Suitable For Neonates And Infants , Special Full Body 3T Mri Compatible Singlechamber Aicd With Df1 Lead Compatibility With Thin Icd Lead Compatible With 7 Fr. Insertion Sheath , Special Full Body 3T Mri Compatible Singlechamber Aicd With Df4 Lead Compatibility With Thin Icd Lead Compatible With 7 Fr. Insertion Sheath , Special Full Body 3T Mri Compatible Dualchamber Aicd With Df1 Lead Compatibility With Thin Icd Lead Compatible With 7 Fr. Insertion Sheath , Special Full Body 3T Mri Compatible Singlechamber Aicd With Df4 Lead Compatibility With Thin Icd Lead Compatible With 7 Fr. Insertion Sheath , Specialsubcutaneousicdwith Subcutaneous Sternal Lead , Fda Approved Single Chamber Leadless Pacemaker Along With Delivery System , Fda Approved Remote Monitoring Module, With The Help Of Which Patient Can Transfer Device Data To Server So That Physician Can Analyse That Device Parameters On Server With Login Facility. , Event/External Loop Recorders. External Cardiac Event Recorder, Minimum Single Lead With Minimum Of 7 Days Recording , Fda Approved 3 Tesla Whole Body Mri Conditional Epicardial Steroid Eluting Bipolar Pacing Lead , Fda Approved Longendocardial Lead For Implantation Via Femoral Approach , Fda Approved 3 Tesla Whole Body Mri Condition Single Chamber Pacemaker Vvir/ Aair Generator Only With Warranty , Ce Approved 3 Tesla Whole Body Mri Conditional Single Chamber Pacemaker Vvir/Aair Generator Only With Warranty , Fda Approved 3 Tesla Whole Body Mri Conditional Dual Chamber Pacemaker Dddr Generator Only With Warranty , Ce Approved 3 Tesla Whole Body Mri Conditional Dual Chamber Pacemaker Dddr Generator Only With Warranty