| 1 | PLCC Equipments |
| 2 | 400kV PLCC for Raebareli S/S |
| 3 | Line traps |
| 4 | PLCC Cabinets (Digital) |
| 5 | Carrier equipment ( Speech+data+protection) 80 Watt |
| 6 | Coupling device (2 LMU + 1 BT) |
| 7 | EPAX (24/8) with 24 nos telephones, cable etc |
| 8 | 4 wire telephone instrument( alongwith telephone wiring) |
| 9 | HF cable |
| 10 | Digital Tele-Protection Coupler (4 Commands) |
| 11 | FOTE (4 Directions with redundancy STM-16 with 4 Nos. STM-1 SFP as spare) as per technical specification & list of FOTE equipments |
| 12 | 400kV PLCC for Fatehpur S/S |
| 13 | PLCC Cabinets (Digital) |
| 14 | Carrier equipment ( Speech+data+protection) 80 Watt |
| 15 | Coupling device (2 LMU + 1 BT) |
| 16 | HF cable |
| 17 | Digital Tele-Protection Coupler (4 Commands) |
| 18 | FOTE (4 Directions with redundancy STM-16 with 4 Nos. STM-1 SFP as spare) as per technical specification & list of FOTE equipments |
| 19 | 400kV PLCC for NTPC Unchahar |
| 20 | PLCC Cabinets (Digital) |
| 21 | Carrier equipment ( Speech+data+protection) 80 Watt |
| 22 | Coupling device (2 LMU + 1 BT) |
| 23 | HF cable |
| 24 | Digital Tele-Protection Coupler (4 Commands) |
| 25 | FOTE (4 Directions with redundancy STM-16 with 4 Nos. STM-1 SFP as spare) as per technical specification & list of FOTE equipments |
| 26 | 220kV PLCC For 400 kV Raebareli |
| 27 | PLCC Cabinets (Digital) |
| 28 | Carrier equipment ( Speech+data+protection) 40 Watt, with 4 command protection coupler |
| 29 | Coupling device (2 LMU + 1 BT) |
| 30 | HF cable |
| 31 | LT Switchgear |
| 32 | 415V Air Conditioning and Ventilation DB |
| 33 | 250 kVA, 440V Silent type DG Set along with accessories and control panel |
| 34 | Fire prevention & extinguishing system |
| 35 | Remaining Works of HVW spray system, Hydrant system and complete U/G & O/G piping and accessories etc. out side the pump house for 2x500 MVA, 2x160 MVA Auto Transformers and 125 MVAR Bus Reactor including all pipelines, angle, tees, strainer etc as per directions of Engineer in Charge (Pipelines, angle, tees, strainer shall be provided by department). |
| 36 | Remaining Works of Fire Protection and microprocessor based fire detection alarm system comprising of smoke & heat type detectors for GIS cum Control room buildings, Control & Relay panels rooms, DG set room etc. as per technical specification. |
| 37 | Illumination System |
| 38 | Illumination System with LED/CFL/Metal Halide Lamp as per technical specification(All the lights & fittings shall preferably be of LED type) |
| 39 | Control Room Building |
| 40 | GIS Halls |
| 41 | Relay & Protection Panel Rooms |
| 42 | DG Set Room / FWPH |
| 43 | Indoor Lighting for 10 cars Parking shed |
| 44 | Switchyard/ Street Lighting (High Mast Lighting System) |
| 45 | Grounding/ Earthing System |
| 46 | 40mm MS rod for Main Earthmat |
| 47 | 40mm diaMS electrodes of 3 metre length |
| 48 | Flat for Earthing |
| 49 | 75x12 mm MS Flat |
| 50 | 50x6 mm MS Flat |
| 51 | 25x6 mm MS Flat |
| 52 | 75x12 mm Copper Flat (For GIS Switchgear Screening, Shielding and Earthing) |
| 53 | 50x6 mm Copper Flat |
| 54 | Spike for top of GIS Hall |
| 55 | EOT Crane (Double Girder Type) with micro settings complete in all respect |
| 56 | for 220kV GIS Building |
| 57 | Erection Hardware: |
| 58 | 400 kV DM-type Layout for GIS Termination Arrangement |
| 59 | Insulator strings, Disc Insulators, Hardware coductor, bus-bar materials, Bay MB, clamps, spacers, connectors including equipment connectors, junction box, earthwire, earthing material risers, buried cable trenches,/pipe equipment & lighting, all accessories etc. for the following: |
| 60 | Transformer Bay |
| 61 | Reactor Bay |
| 62 | Line Bay |
| 63 | 220 kV DM-type Layout for GIS Termination Arrangement |
| 64 | Insulator strings, Disc Insulators, Hardware coductor, bus-bar materials, Bay MB, clamps, spacers, connectors including equipment connectors, junction box, earthwire, earthing material risers, buried cable trenches,/pipe equipment & lighting, all accessories etc. for the following: |
| 65 | Transformer Bay |
| 66 | Line Bay |
| 67 | 132 kV DM-type Layout for GIS Termination Arrangement |
| 68 | Insulator strings, Disc Insulators, Hardware coductor, bus-bar materials, Bay MB, clamps, spacers, connectors including equipment connectors, junction box, earthwire, earthing material risers, buried cable trenches,/pipe equipment & lighting, all accessories etc. for the following: |
| 69 | Transformer Bay |
| 70 | Line Bay |
| 71 | Erection Hardware for the 72.5 kV and 36 kV |
| 72 | Erection Hardware for 72.5 kV Equipment |
| 73 | Erection Hardware for 36kV kV Equipment |
| 74 | Complete Testing & Commissioning of Substation including Station Transformers,Outdoor Surge Arrestors, CTs, CVTs, CBs, Isolator, Ventilation System, LT switchgear, Battery and battery charger system, Earh Resistance Calculation, Illumination System, EOT cranes, all erection hardwares & fittings, in co-ordination with all OEMs/other vendors for proper commissioning of 400/220/132 KV GIS Substation |