}

Flow Measurement In Connection With Functionability Assessment At Different Points Of Different Zones Of Mograhat-I Block Under Falta Mathurapur Mega Surface Water Based Water Supply Project In South 24 Pgs District Under Smd Phe Dte., Kolkata-West Bengal

Public Health Engineering Department has published Flow Measurement In Connection With Functionability Assessment At Different Points Of Different Zones Of Mograhat-I Block Under Falta Mathurapur Mega Surface Water Based Water Supply Project In South 24 Pgs District Under Smd Phe Dte.. Submission Date for this Tender is 25-03-2025. Flowmeters Tenders in Kolkata West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

48203075
Flow Measurement In Connection With Functionability Assessment At Different Points Of Different Zones Of Mograhat-I Block Under Falta Mathurapur Mega Surface Water Based Water Supply Project In South 24 Pgs District Under Smd Phe Dte.
Open Tender
Indian
West Bengal
Kolkata
25-03-2025

Tender Documents

Tender Details

Flow Measurement In Connection With Functionability Assessment At Different Points Of Different Zones Of Mograhat-I Block Under Falta Mathurapur Mega Surface Water Based Water Supply Project In South 24 Pgs District Under Smd Phe Dte.-2 Supply , delivery & storage at site of Full Bore Electromagnetic Flowmeter with inbuilt RTU and pressure sensor- 3 Full Bore type Electro Magnetic Flow meter with smart Transmitter ,protection : IP 67 ,output: Cellular radio,RX pulse/switch output 1X status input with 4 line backlit display, calibration lab as per ISO 17025 ,Accuracy : 0.5% +/- 2 mm /sec , measuring,Reference & Empty pipe ,Detection electrode with polyurethane /hard Rubber liner supply : 24 V DC /230 V AC operation via Bluetooth pressure Cell: 40 Bar with inbuilt 10 meter cable . The data logger logs up to 10,000 items A data item consists ofa time stamp and the configured values: volume flow, pressure, electrical conductivity, Totalizer 1 ,Totalizer 2, Totalizer 3, systems diagnostics status.The TLS encryption protocol is used fro wireless communication between the flow meter and the MQTT broker Make-Endress+Hauser/Krone marshall/Siemens/Any other approved vendor of PHED 4 Magntic Flow Meter DN 150 5 Supply , delivery & storage at site of weather proof Protection panel consisting of Fully wire protection panel with24 V DC,SMPS,Surge protection ,over voltage protection ,MCB all complete as per direction of EIC 6 Supply and Installation at site of MS flanged Dismantling joint ( PN 1.0 rating)-2 nos. , MS fabricated companion flanges(FF,IS: 6392 Tab 11)drilling to match as per IS 1538 table 4 & 6 ,DN 150 Slip on flange-2 nos., short piece with one end flange & one end socketed-2 nos., reducer/enlarger of appropriate size, Gaskets as requiredas per direction of EIC 7 Installation of flowmeter ( vertical mounting at suitable man height position ) as in item no. 1.0with proper allignment ,connection , protection etc all complete as per direction of EIC. (This is also including the charge of hiringtools & tackles ,welding including hiring of DG set , scaffolding arrangement (if required)arrangement of proper supporting etc all complete .) 8 Installation ofProtection panel (including connection of screened control cable through appropriate PVC conduit ( including the supply)the same as in item no. 2.0with proper allignment etc all complete 9 Supply and fixing of 4mm thick fabricated MS sheet protection boxfor vertical mountedflowmeter with hinge door , lockingarrangement andappropriate size MS angle support ,grouting etc all complete as per direction of EIC 10 Trial run for 12 months ( after installation and Commissioning) , calibration of meter by referral meter time to time ,configuration of meters, data analysis ,data upload ,submission of reports etc all complete 11 N.B.: 1. Test Certificate & Calibration certificate of the flowmeter should be submitted at the time of delivery.2. The system should have a provision for sending data in the end of Server/SCADA/Cloud should be provided and all the requirements for the same need to be furnished at the site endto make a successful communication between device and server /SCADA/ Cloud.

Key Value

Document Fees
Refer document
EMD
INR 130000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail