| 1 | Overhauling of cooling fans of transformer at 132KV substation Handia, Gyanpur (PC) and Saidabad Prayagraj under ETD-I Prayagraj. The job includes disconnection of supply cable, dismantling the fan from fan mounting frame then opening of fan motor, bearing, straightening of motor shaft, replacement of defective bearing, refitting of fan motor. Fixing of cooling fan at fan mounting frame and checking performance of fan upto 02 hours after connecting proper supply. |
| 2 | 132KV S/S Handia |
| 3 | 40 MVA T/F-I |
| 4 | 40 MVA T/F-II |
| 5 | 40 MVA T/F-III |
| 6 | 132KV S/S Gyanpur |
| 7 | 20 MVA T/F-I |
| 8 | 20MVA T/F-II |
| 9 | 132KV S/S Saidabad |
| 10 | 20 MVA T/F-I |
| 11 | 20 MVA T/F-II |
| 12 | Supply and fixing of01 no,415 volt,32 A,4NO,contactor for main supply of cooling fans installed onT/F .Work includes proper connection of contactor with ACDB or AC cubical installed in the switchyard. |
| 13 | 132KV S/S Handia |
| 14 | 40MVA T/F II |
| 15 | 132KV S/S Saidabad |
| 16 | 20MVA T/F-I |
| 17 | Supply of,415 volt,32 A,4NO,contactor of L & T, Siemens, ABB make as per sample. |
| 18 | 132KV S/S Handia |
| 19 | 132KV S/S Saidabad |
| 20 | 132KV S/S Gyanpur PC |
| 21 | Supply and fixingoverload relay (Type 3US5000) of rating (0.5-2A) for cooling fan of transformers on the front side of the marshaling box. |
| 22 | 132KV S/S Handia |
| 23 | 40MVA T/F I & T/F-II |
| 24 | 132KV S/S Gyanpur PC |
| 25 | 20MVA T/F- II |
| 26 | Supply ofoverload relay (Type 3US5000) of rating (0.5-2A) for cooling fan of transformers of L & T, Siemens, ABB make as per sample. |
| 27 | 132KV S/S Handia |
| 28 | 132KV S/S Saidabad |
| 29 | 132KV S/S Gyanpur PC |
| 30 | Supply and fixing offan control contactors of rating 440 V,16A,08 NO,for auto function of cooling fans andrelays of rating 230 V,10A,02 NO+02NC for supply monitoring for cooling fans. |
| 31 | 132KV S/S Handia |
| 32 | 40MVA T/F I |
| 33 | 132KV S/S Saidabad |
| 34 | 20MVA T/F- II |
| 35 | Supply offan control contactors of rating 440 V,16A,08 NO,for auto function of cooling fans. |
| 36 | 132KV S/S Handia |
| 37 | 132KV S/S Saidabad |
| 38 | 132KV S/S Gyanpur PC |
| 39 | Supplyof 4 poleMCB of rating 230 V, 16A 4poleof L & T, Siemens, ABB make as per sample. |
| 40 | 132KV S/S Handia |
| 41 | 132KV S/S Saidabad |
| 42 | 132KV S/S Gyanpur PC |
| 43 | Complete overhauling of 62.5 KVA Kirloskar Green make diesel generator set installed at 132 KV S/S Saidabad. Work includes replacement of feed pump kit cam beering tapped roller, control rod starting spring, oil seal, packing kit, including radiator cleaning, self starting making effective one and associated work to complete the work satisfactory |
| 44 | Supply and fixing of 150AH lead acid battery make luminous/exide suitable for 63 KVA DG set. Work includes changingdamaged lead acid battery with new one and testing of proper functionig of DG set under supervision of JE/SDO at 132 KV S/S Saidabad. |