Tender For Conversion Of Oh Conductors To Lt Ug Cable, Lt Panel And Connected Work At Nagrota; 1 Earthing completewith galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth strip 32x6 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel,PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish ,internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge,80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit shall be filled withcharcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified includingprovision of 40mm dia light grade GI pipe for earth strip protection and 20 mm dia for watering complete ,all excavation andearth work & connecting the earthing to an earthing test point / main switch board as specified and testing on completion complete. 2 Earthing completewith galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm diaby means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel,PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish ,internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge,80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit shall be filled withcharcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified includingprovision of 15mm dia light grade GI pipe for earth wire protection and 20 mm dia for watering complete ,all excavation andearth work & connecting the earthing to an earthing test point / main switch board as specified and testing on completion complete. 3 Earth work in excavation by mechanical means Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 3m, including getting out in any type of soil (the excavated soil) anddisposal of surplus excavated soil, within a lead of 50m complete all as specified and directed. 4 Returning, filling in any type of soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm, complete all as specified and as directed. 5 Double walled corrugated (DWC) pipe for cable protection with outer dia 40mm andinner dia 32 mm including suitable size of coupler for connection of pipe complete all as specified and directed. 6 Double walled corrugated (DWC) pipe for cable protection with outer dia 50 mm andinner dia 38 mm including suitable size of coupler for connection of pipe complete all as specified and directed. 7 Double walled corrugated (DWC) pipe for cable protection with outer dia 63mm andinner dia 50mm including suitable size of coupler for connection of pipe complete all as specified and directed. 8 Double walled corrugated (DWC) pipe for cable protection with outer dia 77mm andinner dia 63 mm including suitable size of coupler for connection of pipe complete all as specified and directed. 9 Double walled corrugated (DWC) pipe for cable protection with outer dia 90mm andinner dia 75mm including suitable size of coupler for connection of pipe complete all as specified and directed. 10 Supply,laying, jointing, testing and commissioning aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured and overall PVC sheathed, heavy duty, 1100 volts grade in trenches/on surface of wall/ in DWC pipe including dressing and clamping the cable with MS Zinc Passivated clamps and fixing suitable thimbles/lugs including cable glands of suitable size etc; for following cross sectional area of cable complete all as specified and directed. 11 Cross sectional area 630 Sqmm, 3.5 core 12 Cross sectional area 400 Sqmm, 3.5 core 13 Cross sectional area 300 Sqmm, 3.5 core 14 Cross sectional area 240 Sqmm, 3.5 core 15 Cross sectional area 185 Sqmm, 3.5 core 16 Cross sectional area 150 Sqmm, 3.5 core 17 Cross sectional area 120 Sqmm, 3.5 core 18 Cross sectional area 95 Sqmm, 3.5 core 19 Cross sectional area 70 Sqmm, 3.5 core 20 Cross sectional area 50 Sqmm, 3.5 core 21 Cross sectional area 35 Sqmm, 3.5 core 22 Cross sectional area 25 Sqmm, 4 core 23 Cross sectional area 16 Sqmm, 4 core 24 Cross sectional area 16 Sqmm, 2 core 25 Cross sectional area 10 Sqmm, 2 core 26 Notes for Srl item No.10.00 (a) Earth work shall be measured and paid separately.(b) The quoted rates shall be deemed to be include the following:- (i) Colour code of LT cables shall be as per IS standard.(ii) Pre-dispatch inspection ofLT cables shall be carried out at manufactures factory by the rep of Accepting Officer before dispatching to site.(iii)) Cable shall be marked or embossed as GE Nagrota at every one metre length. 27 Steel tubular swaged pole complete with base plate and top cover welded with pole, bolt, nut and screws as specified type 410 SP-31 (9.0m long) including one coat of red-oxide zinc chrome primer and two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternately on external surface above PCC benching including numbering with black paint and painting with bituminous paint internally complete and externally for portion embedded in PCC, complete all as specified and directed. Note:- PCC, earth work shall be measured & paid separately under respective items. 28 Supply, fixing, commissioning and testing of CPRI approved outdoor cubical type LT Feeder pillar box suitable for 415volts 3 phase 4 wire, 50 HZ AC supply system, floor mounted, outdoor type factory fabricated duly power coated inside and outside, outer cover made out of 3.15 mm thick CRCA sheet, internal cover and partition made out of 2 mm thick CRCA sheet with angle iron 50 mm x 50 mm x 6 mm covered from all side with front and back openable, weather proof including suitable size rating aluminium bus bar for 3 phase 4 wire system, wiring with suitable size copper cable and embedded in brickwork in CM 1:4 not less than 60cm above ground level with suitablefoundation for fixing panel of required size in ground with nuts, bolts and washer etc. including comprising of following including taking out the old unserviceable panel complete all as specified and directed by Engineer-in-Charge.Note:- Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 40 cm above ground level and 20 cm below ground level with suitable foundation, rendering 15 mm in CM 1:6 and applying two coats of cement base paint and the rates shall be inclusive in the quoted rate. Main LT Panel ( Pionner unit) & 16 CSR. 29 Incoming:(a) ACB 800 Amp 4 pole 50 KA, Microprocessor based - 01 No.(b) Alum bus bar 1200 Amp TPN - 01 Set(c) Digital Multifunctional meter Showing V, I, PF, HZ etc with suitable CT ratio(d) Indicator lamp LBD type (RYB) complete with bakelite fuse fitting- 01 setOutgoing:(a) MCCB 4 Pole, 250Amp, 36 KA Adjustable Thermal & adjustable Magnetic setting , Ics = 100% of Icu,-01 No.(b) MCCB 4 Pole, 200 Amp, 36 KA, Adjustable Thermal & adjustable Magnetic setting , Ics = 100% of Icu - 05 No.(c) MCCB 4 Pole, 63 Amp, 20 KA Adjustable Thermal & Fixed Magnetic setting , Ics = 100% of Icu - 03 No. 30 Supply, fixing, commissioning and testing of CPRI approved outdoor cubical type LT Feeder pillar box suitable for 415volts 3 phase 4 wire, 50 HZ AC supply system, floor mounted, outdoor type factory fabricated duly power coated inside and outside, outer cover made out of 3.15mm thick CRCA sheet, internal cover and partition made out of 2 mm thick CRCA sheet with angle iron 50 mm x 50 mm x 6 mm covered from all side with front and back openable, weather proof including suitable size rating aluminium bus bar for 3 phase 4 wire system, wiring with suitable size copper cable and embedded in brickwork in CM 1:4 not less than 60cm above ground level with suitablefoundation for fixing panel of required size in ground with nuts, bolts and washer etc. including comprising of following including taking out the old unserviceable panel complete all as specified and directed by Engineer-in-Charge.Note:- Note:- Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 40 cm above ground level and 20 cm below ground level with suitable foundation, rendering 15 mm in CM 1:6 and applying two coats of cement base paint and the rates shall be inclusive in the quoted rate. Main LT Panel ( 4 ASD) 31 Incoming:(a) ACB 630 Amp 4 pole 50 KA,drawout typed with Microprocessor based - 01 No.(b) Alum bus bar 1000 Amp TPN - 01 Set(c) Digital Multifunctional meter Showing V, I, PF, HZ etc with suitable CT ratio(d) Indicator lamp LBD type (RYB) complete with bakelite fuse fitting- 01 setOutgoing(a) MCCB 4 Pole, 160 Amp, 45 KA, Adjustable Thermal & adjustable Magnetic setting , Ics = 100% of Icu-03 No.(b) MCCB 4 Pole, 100 Amp, 20 KA Adjustable Thermal & Fixed Magnetic setting , Ics = 100% of Icu - 02 No.(c) MCCB 4 Pole, 63 Amp,45 KA ,Adjustable Thermal & Fixed Magnetic setting , Ics = 100% of Icu - 03 No. 32 Supply, fixing, commissioning and testing of CPRI approved outdoor cubical type LT Feeder pillar box suitable for 415volts 3 phase 4 wire, 50 HZ AC supply system, floor mounted, outdoor type factory fabricated duly power coated inside and outside, outer cover made out of 3.15mm thick CRCA sheet, internal cover and partition made out of 2 mm thick CRCA sheet with angle iron 50 mm x 50 mm x 6 mm covered from all side with front and back openable, weather proof including suitable size rating aluminium bus bar for 3 phase 4 wire system, wiring with suitable size copper cable and embedded in brickwork in CM 1:4 not less than 60cm above ground level with suitablefoundation for fixing panel of required size in ground with nuts, bolts and washer etc. including comprising of following including taking out the old unserviceable panel complete all as specified and directed by Engineer-in-Charge. Main LT Panel ( CMP ) Note:- Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 40 cm above ground level and 20 cm below ground level with suitable foundation, rendering 15 mm in CM 1:6 and applying two coats of cement base paint and the rates shall be inclusive in the quoted rate. 33 Incoming:(a) ACB 630 Amp 4 pole 50 KA,drawout typed with Microprocessor based - 01 No.(b) Alum bus bar 1000 Amp TPN - 01 Set(c) Digital Multifunctional meter Showing V,I, PF , HZ etc with suitable CT ratio(d) Indicator lamp LBD type (RYB) complete with bakelite fuse fitting- 01 setOutgoing(a)MCCB 4 Pole, 250 Amp, 36 KA, Adjustable Thermal & adjustable Magnetic setting , Ics = 100% of Icu - 01 No.(b)MCCB 4 Pole, 200 Amp, 36 KA, Adjustable Thermal & adjustable Magnetic setting , Ics = 100% of Icu - 01 No.(c)MCCB 4 Pole, 125 Amp, 25 KA, Adjustable Thermal & Fixed Magnetic setting , Ics = 100% of Icu- 01 No.(d)MCCB 3 Pole, 63 Amp, 20 KA, Adjustable Thermal & Fixed Magnetic setting , Ics = 100% of Icu- 01 No. 34 Supply, fixing, commissioning and testing of CPRI approved outdoor cubical type LT Feeder pillar box suitable for 415volts 3 phase 4 wire, 50 HZ AC supply system, floor mounted, outdoor type factory fabricated duly power coated inside and outside, outer cover made out of 3.15mm thick CRCA sheet, internal cover and partition made out of 2 mm thick CRCA sheet with angle iron 50 mm x 50 mm x 6 mm covered from all side with front and back openable, weather proof including suitable size rating aluminium bus bar for 3 phase 4 wire system, wiring with suitable size copper cable and embedded in brickwork in CM 1:4 not less than 60cm above ground level with suitablefoundation for fixing panel of required size in ground with nuts, bolts and washer etc. including comprising of following including taking out the old unserviceable panel complete all as specified and directed by Engineer-in-Charge. Main LT Panel ( 651 EPU )Note:- Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 40 cm above ground level and 20 cm below ground level with suitable foundation, rendering 15 mm in CM 1:6 and applying two coats of cement base paint and the rates shall be inclusive in the quoted rate. 35 Incoming:(a) ACB 630 Amp 4 pole 50 KA,drawout typed with Microprocessor based - 01 No.(b) Alum bus bar 1000 Amp TPN - 01 Set(c) Digital Multifunctional meter Showing V,I, PF , HZ etc with suitable CT ratio(d) Indicator lamp LBD type (RYB) complete with bakelite fuse fitting- 01 setOutgoing(a)MCCB 4 Pole, 250 Amp, 36 KA, Adjustable Thermal & adjustable Magnetic setting , Ics = 100% of Icu - 01 No.(b)MCCB 4 Pole, 200 Amp, 20 KA, Adjustable Thermal & adjustable Magnetic setting , Ics = 100% of Icu - 01 No.(c)MCCB 4 Pole, 125 Amp, 20 KA, Adjustable Thermal & fixed Magnetic setting , Ics = 100% of Icu - 01 No.(d)MCCB 4 Pole, 63 Amp, 20 KA, Adjustable Thermal & Fixed Magnetic setting , Ics = 100% of Icu - 02 No. 36 Supply, fixing, commissioning and testing of CPRI approved outdoor cubical type LT Feeder pillar box suitable for 415volts 3 phase 4 wire, 50 HZ AC supply system, floor mounted, outdoor type factory fabricated duly power coated inside and outside, outer cover made out of 3.15mm thick CRCA sheet, internal cover and partition made out of 2 mm thick CRCA sheet with angle iron 50 mm x 50 mm x 6 mm covered from all side with front and back openable, weather proof including suitable size rating aluminium bus bar for 3 phase 4 wire system, wiring with suitable size copper cable and embedded in brickwork in CM 1:4 not less than 60cm above ground level with suitablefoundation for fixing panel of required size in ground with nuts, bolts and washer etc. including comprising of following including taking out the old unserviceable panel complete all as specified and directed by Engineer-in-Charge. Main LT Panel ( EME old Location )Note:- Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 40 cm above ground level and 20 cm below ground level with suitable foundation, rendering 15 mm in CM 1:6 and applying two coats of cement base paint and the rates shall be inclusive in the quoted rate. 37 Incoming:(a) ACB 630 Amp 4 pole 50 KA,drawout typed with Microprocessor based - 01 No.(b) Alum bus bar 1000 Amp TPN - 01 Set(c) Digital Multifunctional meter Showing V,I, PF , HZ etc with suitable CT ratio(d) Indicator lamp LBD type (RYB) complete with bakelite fuse fitting- 01 setOutgoing(a)MCCB 4 Pole, 315 Amp, 36 KA,Adjustable Thermal & adjustableMagnetic setting , Ics = 100% of Icu- 01 No.(b)MCCB 4 Pole, 200 Amp, 36 KA, Adjustable Thermal & adjustable Magnetic setting , Ics = 100% of Icu- 01 No.(c)MCCB 4 Pole, 63 Amp, 20 KA, Adjustable Thermal & Fixed Magnetic setting , Ics = 100% of Icu - 02 No. 38 Supply, fixing, commissioning and testing of CPRI approved outdoor cubical type LT Feeder pillar box suitable for 415volts 3 phase 4 wire, 50 HZ AC supply system, floor mounted, outdoor type factory fabricated duly power coated inside and outside, outer cover made out of 3.15mm thick CRCA sheet, internal cover and partition made out of 2 mm thick CRCA sheet with angle iron 50 mm x 50 mm x 6 mm covered from all side with front and back openable, weather proof including suitable size rating aluminium bus bar for 3 phase 4 wire system, wiring with suitable size copper cable and embedded in brickwork in CM 1:4 not less than 60cm above ground level with suitablefoundation for fixing panel of required size in ground with nuts, bolts and washer etc. including comprising of following including taking out the old unserviceable panel complete all as specified and directed by Engineer-in-Charge. Main LT Panel ( EME new Location )Note:- Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 40 cm above ground level and 20 cm below ground level with suitable foundation, rendering 15 mm in CM 1:6 and applying two coats of cement base paint and the rates shall be inclusive in the quoted rate. 39 Incoming:(a) ACB 630 Amp 4 pole 50 KA,drawout typed with Microprocessor - 01 No.(b) Alum bus bar 1000 Amp TPN - 01 Set(c) Digital Multifunctional meter Showing V,I, PF , HZ etc with suitable CT ratio(d) Indicator lamp LBD type (RYB) complete with bakelite fuse fitting- 01 setOutgoing(a) MCCB 4 Pole, 250 Amp, 36 KA, Adjustable Thermal & adjustable Magnetic setting , Ics = 100% of Icu- 01 No.(b) MCCB 4 Pole, 200 Amp, 36 KA, Adjustable Thermal & adjustable Magnetic setting , Ics = 100% of Icu - 01 No.(c) MCCB 4 Pole, 125 Amp, 20 KA, Adjustable Thermal & Fixed Magnetic setting , Ics = 100% of Icu - 01 No.(d) MCCB 4 Pole, 63 Amp, 20 KA, Adjustable Thermal & Fixed Magnetic setting , Ics = 100% of Icu - 02 No. 40 Supply, fixing, commissioning and testing of CPRI approved outdoor cubical type LT Feeder pillar box suitable for 415volts 3 phase 4 wire, 50 HZ AC supply system, floor mounted, outdoor type factory fabricated duly power coated inside and outside, outer cover made out of 3.15mm thick CRCA sheet, internal cover and partition made out of 2 mm thick CRCA sheet with angle iron 50 mm x 50 mm x 6 mm covered from all side with front and back openable, weather proof including suitable size rating aluminium bus bar for 3 phase 4 wire system, wiring with suitable size copper cable and embedded in brickwork in CM 1:4 not less than 60cm above ground level with suitablefoundation for fixing panel of required size in ground with nuts, bolts and washer etc. including comprising of following including taking out the old unserviceable panel complete all as specified and directed by Engineer-in-Charge. Main LT Panel ( R&O Adm Area)Note:- Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 40 cm above ground level and 20 cm below ground level with suitable foundation, rendering 15 mm in CM 1:6 and applying two coats of cement base paint and the rates shall be inclusive in the quoted rate. 41 Incoming:(a) MCCB 400 Amp 4 pole 45 KA Adjustable Thermal* & adjustable Magnetic setting , Ics = 100% of Icu - 01 No.(b) Alum bus bar 600 Amp TPN - 01 Set(c) Digital Multifunctional meter Showing V,I, PF , HZ etc with suitable CT ratio(d) Indicator lamp LBD type (RYB) complete with bakelite fuse fitting- 01 setOutgoing(a) MCCB 4 Pole, 250 Amp, 36 KA, Adjustable Thermal & adjustableMagnetic setting , Ics = 100% of Icu- 02 No.(b) MCCB 4 Pole, 63 Amp, 20 KA, Adjustable Thermal & Fixed Magnetic setting, Ics = 100% of Icu- 02 No. 42 Supply, fixing, commissioning and testing of CPRI approved outdoor cubical type LT Feeder pillar box suitable for 415volts 3 phase 4 wire, 50 HZ AC supply system, floor mounted, outdoor type factory fabricated duly power coated inside and outside, outer cover made out of 3.15mm thick CRCA sheet, internal cover and partition made out of 2 mm thick CRCA sheet with angle iron 50 mm x 50 mm x 6 mm covered from all side with front and back openable, weather proof including suitable size rating aluminium bus bar for 3 phase 4 wire system, wiring with suitable size copper cable and embedded in brickwork in CM 1:4 not less than 60cm above ground level with suitablefoundation for fixing panel of required size in ground with nuts, bolts and washer etc. including comprising of following including taking out the old unserviceable panel complete all as specified and directed by Engineer-in-Charge. Main LT Panel ( R&O tech Area)Note:- Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 40 cm above ground level and 20 cm below ground level with suitable foundation, rendering 15 mm in CM 1:6 and applying two coats of cement base paint and the rates shall be inclusive in the quoted rate. 43 Incoming:(a) ACB 630 Amp 4 pole 50 KA, Microprocessor based - 01 No.(b) Alum bus bar 1000 Amp TPN - 01 Set(c) Digital Multifunctional meter Showing V,I, PF , HZ etc with suitable CT ratio(d) Indicator lamp LBD type (RYB) complete with bakelite fuse fitting- 01 setOutgoing(a) MCCB 4 Pole, 250 Amp, 36 KA, Adjustable Thermal & adjustable Magnetic setting , Ics = 100% of Icu- 01 No.(b) MCCB 4 Pole, 160 Amp, 36 KA, Adjustable Thermal & adjustable Magnetic setting , Ics = 100% of Icu- 03 No.(c) MCCB 4 Pole, 100 Amp, 25 KA, Adjustable Thermal & adjustable Magnetic setting , Ics = 100% of Icu- 01 No.(d) MCCB 4 Pole, 63 Amp, 20 KA, Adjustable Thermal & Fixed Magnetic setting , Ics = 100% of Icu- 02 No. 44 Supply, Fixing , Commissioning and testing of CPRI approved outdoor cubical type LT Feeder Pillar box suitable for 415 V, 3 Phase , 4 wire50 Hz , AC Supply system fabricated from MS Sheettotally encloused ,dust, weather & vermin proof, 3.15mm thick for outer shell and 2 mm thick for inner shell having MS section not less than 50x50x6 mm thick havingTPN aluminium busbar of capacity 500 Amps mounted on porcelain insulatorduly drilled hole for cable connection including front and rear side opening with locking arrangement with Digital Multifunctional meter Showing V,I, PF , HZ etc with suitable CT ratio also with MCCB 4P 315 Amp, 36 KA, 415 Volts 50 Hz with adjustable thermal and adjustable magnetic setting and provn for incoming and outgoing cables withglands includingcontrol wiring with minimum 2.5 sqmm PVC insulated copper conductor for measuring of voltage, amp with indicators RYB ,painting with two coat of smoke grey synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.Note:- Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 30 cm above ground level with suitable foundation, rendering 15 mm in CM 1:6 and two coats of cement base paint and the rates shall be inclusive in the quoted rate. 45 Supply, Fixing , Commissioning and testing of CPRI approved outdoor cubical type LT Feeder Pillar box suitable for 415 V, 3 Phase , 4 wire50 Hz , AC Supply system fabricated from MS Sheettotally encloused ,dust, weather & vermin proof , 3.15 mm thick for outer shell and 2 mm thick for inner shell having MS section not less than 50x50x6 mm thick havingTPN aluminium busbar of capacity 400 Amps mounted on porcelain insulatorduly drilled hole for cable connection including front and rear side opening with locking arrangement with Digital Multifunctional meter Showing V,I, PF , HZ etc with suitable CT ratio also with MCCB 4P 250 Amp, 36 KA, 415 Volts 50 Hz with adjustable thermal and adjustable magnetic setting and provn for incoming and outgoing cables withglands includingcontrol wiring with minimum 2.5 sqmm PVC insulated copper conductor for measuring of voltage, amp with indicators RYB ,painting with two coat of smoke grey synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.Note:- Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 30 cm above ground level with suitable foundation, rendering 15 mm in CM 1:6 and two coats of cement base paint and the rates shall be inclusive in the quoted rate. 46 Supply, Fixing , Commissioning and testing of CPRI approved outdoor cubical type LT Feeder Pillar box suitable for 415 V, 3 Phase , 4 wire50 Hz , AC Supply system fabricated from MS sheet totally encloused ,dust, weather & vermin proof, 3.15mm thick for outer shell and 2 mm thick for inner shell having MS section not less than 50x50x6 mm thick havingTPN aluminium busbar of capacity 300 Amps mounted on porcelain insulatorduly drilled hole for cable connection including front and rear side opening with locking arrangement with Digital Multifunctional meter Showing V,I, PF , HZ etc with suitable CT ratio also with MCCB 4P 200 Amp, 36 KA, 415 Volts 50 Hz with adjustable thermal and adjustable magnetic setting and provn for incoming and outgoing cables withglands includingcontrol wiring with minimum 2.5 sqmm PVC insulated copper conductor for measuring of voltage, amp with indicators RYB ,painting with two coat of smoke grey synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.Note:- Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 30 cm above ground level with suitable foundation, rendering 15 mm in CM 1:6 and two coats of cement base paint and the rates shall be inclusive in the quoted rate. 47 Supply, Fixing , Commissioning and testing of CPRI approved outdoor cubical type LT Feeder Pillar box suitable for 415 V, 3 Phase , 4 wire50 Hz , AC Supply system fabricated from MS sheet totally encloused ,dust, weather & vermin proof, 3.15mm thick for outer shell and 2 mm thick for inner shell having MS section not less than 50x50x6 mm thick havingTPN aluminium busbar of capacity 250 Amps mounted on porcelain insulatorduly drilled hole for cable connection including front and rear side opening with locking arrangement with Digital Multifunctional meter Showing V,I, PF , HZ etc with suitable CT ratio also with MCCB 4P 160 Amp, 36 KA, 415 Volts 50 Hz with adjustable thermal and adjustable magnetic setting and provn for incoming and outgoing cables withglands includingcontrol wiring with minimum 2.5 sqmm PVC insulated copper conductor for measuring of voltage, amp with indicators RYB ,painting with two coat of smoke grey synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.Note:- Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 30 cm above ground level with suitable foundation, rendering 15 mm in CM 1:6 and two coats of cement base paint and the rates shall be inclusive in the quoted rate. 48 Supply, Fixing , Commissioning and testing of CPRI approved outdoor cubical type LT Feeder Pillar box suitable for 415 V, 3 Phase, 4 wire50 Hz , AC Supply system fabricated from MS sheet totally encloused ,dust, weather & vermin proof, 3.15mm thick for outer shell and 2 mm thick for inner shell having MS section not less than 50x50x6 mm thick havingTPN aluminium busbar of capacity 200 Amps mounted on porcelain insulatorduly drilled hole for cable connection including front and rear side opening with locking arrangement with Digital Multifunctional meter Showing V,I, PF , HZ etc with suitable CT ratio also with MCCB 4P 125 Amp, 36 KA, 415 Volts 50 Hz with adjustable thermal and fixed magnetic setting and provn for incoming and outgoing cables withglands includingcontrol wiring with minimum 2.5 sqmm PVC insulated copper conductor for measuring of voltage, amp with indicators RYB ,painting with two coat of smoke grey synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.Note:- Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 30 cm above ground level with suitable foundation, rendering 15 mm in CM 1:6 and two coats of cement base paint and the rates shall be inclusive in the quoted rate. 49 Supply, Fixing, Commissioning and testing of CPRI approved outdoor cubical type LT Feeder Pillar box suitable for 415 V, 3 Phase, 4 wire50 Hz , AC Supply system fabricated from MS sheet totally encloused ,dust, weather & vermin proof, 3.15mm thick for outer shell and 2 mm thick for inner shell having MS section not less than 50x50x6 mm thick havingTPN aluminium busbar of capacity 150 Amps mounted on porcelain insulatorduly drilled hole for cable connection including front and rear side opening with locking arrangement with Digital Multifunctional meter Showing V,I, PF , HZ etc with suitable CT ratio also with MCCB 4P 100 Amp, 36 KA, 415 Volts 50 Hz with adjustable thermal and fixed magnetic setting and provn for incoming and outgoing cables withglands includingcontrol wiring with minimum 2.5 sqmm PVC insulated copper conductor for measuring of voltage, amp with indicators RYB ,painting with two coat of smoke grey synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.Note:- Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 30 cm above ground level with suitable foundation, rendering 15 mm in CM 1:6 and two coats of cement base paint and the rates shall be inclusive in the quoted rate. 50 Feeder pillar box out door type ‘factorymade’ made out from 16 SWG MS sheet supported with legs of 45cm long made of iron angle 25x25x4mm thick of size 75cm x60cm x45 cm with 04 Nos aluminiumbus bar of200 Amps mounted on porcelain insulatorduly drilled hole for cable connection including front and rear side opening with locking arrangement provn for incoming and outgoing cables withglands including painting with two coat of smoke grey synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.Note:- Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 30 cm above ground level with suitable foundation, rendering 15 mm in CM 1:6 and two coats of cement base paint and the rates shall be inclusive in the quoted rate. 51 Feeder pillar box out door type ‘factorymade’ made out from 16 SWG MS sheet supported with legs of 45cm long made of iron angle 25x25x4mm thick of size 75cm x60cm x45 cm with 04 Nos aluminiumbus bar of100 Amps mounted on porcelain insulatorduly drilled hole for cable connection including front and rear side opening with locking arrangement provn for incoming and outgoing cables withglands including painting with two coat of smoke grey synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.Note:- Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 30 cm above ground level with suitable foundation, rendering 15 mm in CM 1:6 and two coats of cement base paint and the rates shall be inclusive in the quoted rate. 52 Hot press moulded junction box of size 400mmx300mmx 190mm hinged type including 04 No aluminium bus bar of suitable capacity with fixing arrangement like suitable size clamps, nuts, bolts and washers etc and including SP MCB 6 Amps clamped with pole complete all as specified anddirected. 53 Mounting arm for fixing of LED light made 40mm dia GI pipe light grade of length 2 mts (to be fabricated as per approved design), to be supplied alongwith mounting clamps - 02 No, fabricated from (65mm x 5mm) MS providing 04 no nut, bolt, washer including with clamps, nuts bolts etc; complete all as per directed.Note: The Contractor should fix the clamp as per site requirement. 54 PCC route indicator (solid block) including excavation and other civil work made out of PCCtype B1 1:2:4 using 20mm graded crushed stone aggregate, set in cement Mortar (1:4) of size 30cm x 45cm above ground level and 25cm below ground level for LT cablementioning the size of Cable with paint on PCC block, complete all as specified and directed. 55 Three core copper wire FRLS insulated cable 2.5 Sqmm withand drawn through pole from junction box to street light connection through and including PVC conduit pipe 20mm dia (heavy duty), complete all as specified and directed.Note: Quoted rate include the rate of PVC conduit pipe of 20mm dia. 56 Drilling of concrete road /path with horizontal drilling machine for laying the cable under the road in any type of soil, complete all as specified and directed. 57 Plain Cement concrete 1:2:4, type B-1 (using 20mm graded crushed stone aggregate),as coping etc. and benching including weathering, slightly rounded or chamfered angles and throating including necessary formwork and finishing the exposed surfaces, complete all as specified and directed 58 Plain cement concrete, 1:4:8type D-2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. 59 Plain cement concrete, 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. 60 Dismantling PCC, Steel poles/struts, any size complete all as directed. 61 Dismantling cross arms of M.S. channel or angle sections etc.complete all as directed. 62 Dismantling insulators any type, any size complete all as directed. 63 Dismantling ACSR conductor any type, any size complete all as directed. 64 Dismantling stay assembly complete all as directed. 65 Dismatling of unserviceable LT panel of any type, any size complete all as directed. 66 Dismantling and taking downof any Street light bracket of any fittingsand refixingthe same on newstreet light pole along with mounting clamps - 02 No, fabricated from (65mm x 5mm) MS providing 04 no, nut, bolt, washer including with clamps, nuts, bolts etc. complete all as per directed.Note: The Contractor should fix the clamp as per site requirement. 67 Dismantling and taking down street light fittings any capacity and refixingthe same on newstreet light pole complete all as directed. 68 Deduction to be made from BOQfor Sch A Part -II (Schedule of credit) Amount of Rs. 7,68,440.00 during AOC.Note: Tenderers shall not quote for this schedule.