Tender For Providing Generator Set For Oxygen Generation Plant And Isolation Covid Ward At Civil Hospital Rewari (Pdg. Earthing, Cabling, Hpde Pipe And Foundation Etc. Only)(Pdg. Balance Work)., Rewari-Haryana
TDR : 48159894
Tender Notice
BOQ
Expired
Rewari
Haryana
Tender For Providing Generator Set For Oxygen Generation Plant And Isolation Covid Ward At Civil Hospital Rewari (Pdg. Earthing, Cabling, Hpde Pipe And Foundation Etc. Only)(Pdg. Balance Work).
Name of Work:Construction of RVDEC Centre of LUVAS at Rewasa in Distt Mohindergarh. (Pdg. Light and Fan Fitting Only)
Sl. No.
Item Description
1
[20.71.1]Supply, erection, testing of Ceiling fansIS marked (as per IS code 374) with suitable GI pipe complete in all respects complete as per directions of Engineer-in-charge 1. 48\" (1200mm) [Through Rate]
2
[23.1.6.1]COPPER WIRING IN MS CONDUIT (SURFACE/RECESS) 6.1. Wiring main ,sub mains and Circuit wiring in twosingle core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in MS Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate]
3
[23.5.2.1]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 2.1. Wiring only in existing conduit and MS box for Twin control light point with 2 nos , 2-ways, 5 amp. switch in 1.5 sqmm FRLS PVC insulated copper conductor cable. Group A [Through Rate]
4
[23.5.3.1]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 3.1. Wiring only in existing conduit and MS Box for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable , without separate control switch Group A [Through Rate]
5
[23.5.4.1]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 4.1. Wiring in existing conduit and MS box for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin socket and 1 no 5/6 Amp switch etc complete as required Group A [Through Rate]
6
[23.5.5.1]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 5.1. Wiring in existing conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin socket and 1 no 15/16 Amp switch etccomplete as required Group A [Through Rate]
7
[24.12.46]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING AND ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR CABLE 0.75 METER BELOW GROUND LEVEL COVERED WITHOUT SAND AND BRICKS INCLUDING EXCAVATION AND REFILLING OF TRENCHES 46.50 Sq mm 3.5core (Arm.) [Through Rate]
8
[24.5.2.3]MISCELLANEOUS ITEMS 2.3. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work.DWC/HDPE pipe 63/50 mm outer dia/inner dia [Through Rate]
9
Supply and Erection of Exhaust fan 150mm complete in all respect upto satisfaction of Engineer-in-charge. Make: Bajaj / Usha / Orient / Crompton
10
Supply and Erection of LED Batten 36/40W complete in all respect upto satisfaction of Engineer-incharge. Make: Bajaj /Wipro/ Phillips/Surya Roshni/Orient