| 1 | Safe loading Carriage including unloading and proper stacking of following materials from central store Barabanki / JE Store to site of work. |
| 2 | PCC POLE 8.5 MTR LONG |
| 3 | STP Pole 11 Mtr |
| 4 | T/F11/0.4KV, 63 KVA |
| 5 | T/F11/0.4KV, 100 KVA |
| 6 | T/F11/0.4KV, 250 KVA |
| 7 | MS Top Channel |
| 8 | T-off Channel |
| 9 | MS Channel (Dropper) |
| 10 | LT ABC (3*120+1*95+1*16) SQMM |
| 11 | LT ABC (3*95+1*70+1*16) SQMM |
| 12 | LT ABC (3*50+1*35+1*16) SQMM |
| 13 | Single Core L.T Cable (1*240)SQ MM |
| 14 | Single Core L.T Cable (1*400)SQ MM |
| 15 | Single Core L.T Cable (1*120)SQ MM |
| 16 | 11 KV Composite Polymer Pin Insulater |
| 17 | 11 KV Composite Polymer Disc Insulator With Fitting |
| 18 | Earthing Rod |
| 19 | ACSR WEASEL CONDUCTOR |
| 20 | ACSR Rabbit CONDUCTOR |
| 21 | GI wire 8 SWG |
| 22 | Stay Set complete |
| 23 | Substation Base angle |
| 24 | Dragging of pole from JE Dump Store to site |
| 25 | Grouting Of STP/PCC Pole |
| 26 | Erection of Stay set of 16x1800 mm rod duly painted with red oxide,anchor plate, thumble turn buckle andstay insulate etc. digging of pit of size of size 0.4x0.6x1.6 m for grouting 1:3:6 cement concrete, with stay of size 7/8 SWG, nuzzling & Grouting. |
| 27 | Installation of Mounting of Following capacityof Transformer including its connection between 11 KV and LT Line mountingprovinding Crimping type Aluminium lugs of required size.( All the material except transformer will be arranged by the contractor) |
| 28 | Mounting of 63 KVA Tranformer |
| 29 | Mounting of 100 KVA Tranformer |
| 30 | Mounting of 250 KVA Tranformer |
| 31 | Stringing and sagging of 11 KV line with ACSR Weasel Conductor including nuzzling binding and jumpering (Weasel conductor will be provided by the department) |
| 32 | Stringing and sagging of 11 KV line with ACSR Rabbit Conductor including nuzzling binding and jumpering (Rabbit conductor will be provided by the department) |
| 33 | Errectionof Substation type double pole with ST/PCCincluding mounting of Top Channal Dropper Channel, base angle with clamps with nut & bolt 33/11 KV line including grouting of support and plinthing 300 mm above ground level, fitting of 33/11 KV pin & Pin insulator. 1/6 of total lenght of poles will remain under the ground and planted on stone pad of Size 300x300x75 MM. |
| 34 | Errectionof singlePCC /ST Pole for Stringing and sagging of conductor 1/6 of total length of poles will remain under the ground and planted on stone pad of size 300x300x75 mm. |
| 35 | Stringing and Sagging of LT single core Cable (1x120+1x400+1x120) SQMM (LT Cable will be provided by the department) |
| 36 | Stringing and Sagging of LT ABC Cable(3*120+1*95+1*16) & (3*95+1*70+1*16)and (3*50+1*35+1*16) SQMM (LT Cable will be provided by the department) |
| 37 | MS Earthing Rod. |
| 38 | Provinding & Fixing of various type materials. All materials shall be supplied by the contractor. |
| 39 | Nut & Bolt |
| 40 | Clamp for Top/ Dropper and T-off Channel etc. |
| 41 | Dead End Clamp |
| 42 | Suspension Clamp |
| 43 | Holding Clamp |
| 44 | Insulated Piercing Connector 16-120 sqmm |
| 45 | Dead End Insulator |
| 46 | I-J Hook |
| 47 | Al Lug 95 sqmm |
| 48 | Al Lug 120 sqmm |
| 49 | Al Lug 240 sqmm |
| 50 | Al Lug 400 sqmm |
| 51 | 11 KV D.O FUSE SET Complete |
| 52 | Construction Of LT DistriBution Cum LT Protection Piller Box MS Angle in RectangleSize 50x50x6 MM 7.5Meter long For installation Of Henley Type Tailleness Fuse Unit 300 AMP 650 Volt For 3 nos Outgoing Circuits With Copper Bus bar OF size 1000x50x6 mm Including Proper Grouting of Structure By Digging OF pits Off Size 300x300x600 mm With the Help Of Cement, Coresand And Aggregate in the ratio 1:3:6 And Fabrication of structure Complete. |
| 53 | Wiremesh fencing of 11/0.4 KV substation shall be made rectangular off size as per site requirement not exceeding 3 meter fabrication 45x45x5mm angle. material shall be supplied by the contractor. |
| 54 | Construction of massionary type transformer plinth of Suitable sizewith brick ,cement, coarse sand , sand & brick ballast. Filling of sand in the hollow space , plastering , outer surface in ration 1:4:6 top of the plinth 4\" thickness grouting of 2 nos MS Channel of size 100x50x2000 mm on the top of the plinth for placement of transformer . All material shall be supplied by the contractor. |
| 55 | Erection of pipe type earthng for DT with the help of B-Class G.I pipe of size 1.5 inch dia, 40 feet deep boring by providing G.I strip 50x6 MM, 6 meter long attached with clamp L-piece nut & bolt & G.I cap |