Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | LAND DEVELOPMENT : |
| 2 | Clearing grass and removal of the rubbish outside site premises and at an unobjectionable place. |
| 3 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm. depth dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth within premises |
| 4 | CONSTRUCTION OF SALES BUILDING : |
| 5 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 |
| 6 | i) All kinds of Soil |
| 7 | Extra for every additional lift of 1.5m or part thereof in excavation or banking excavated or stacked materials in all kinds of soil |
| 8 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m |
| 9 | Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete. |
| 10 | i) Local Fine Sand within grading zone IV |
| 11 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5mm nominal size). Item includes providing & mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer\"s specifications. Providing & applying a coat of residual petroleum bitumen of grade VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes & finally with a piece of cloth lightly soaked in kerosene oil |
| 12 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth |
| 13 | Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: |
| 14 | iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) |
| 15 | v) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm) |
| 16 | viii) 1:4:8(1 Cement :4 Coarse Sand :8 Graded stone aggregate of 40mm) |
| 17 | Centeringand shutteringincludingstrutting,proppingetc. and removal of form work for: |
| 18 | i) Foundations,footings,bases of column |
| 19 | Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level |
| 20 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm |
| 21 | Providing & Laying Reinforcedcementconcreteworkinwalls (Any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level UP TO FLOOR V LEVEL excluding cost of centering, shuttering, finishing and reinforcement : |
| 22 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm |
| 23 | Reinforced cement concrete work in beams, suspended floors, roofshavingslopeupto15°landings,balconies,shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircases above plinth level up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate 20 mm nominal size) |
| 24 | Providing and laying RCC work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size). |
| 25 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 26 | i) Foundations,footings,bases of columns, etc. for mass concrete |
| 27 | v) Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 28 | vii) Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards |
| 29 | viii) Suspended floors, roofs,landings balconies and access platform with water proof ply 12mm thick |
| 30 | ix) Lintels, beams, plinth beams, girders, bressumers cantilevers and with water proof ply 12mm thick |
| 31 | Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels |
| 32 | ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 |
| 33 | Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth |
| 34 | ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH |
| 35 | viii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH |
| 36 | Providing and laying dry brick on edge flooring in required pattern with bricks of Class designation 7.5 on a bed of 12 mm mud mortar including filling joints with river sand with common burnt clay non- modular bricks |
| 37 | Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: |
| 38 | Supplying and fixing rolling shutters of approved make, madeof required size M.S. laths interlocked together through their entire length,jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS 4454 Part-I & M.S. top cover of required thickness for rolling shutters:- 80x1.25mm MS laths with1.25 mm thick top cover |
| 39 | Chequered precast cement concrete tiles 22 mm thick in footpath & courtyard jointed with neat cement slurry mixed with pigment to match the shade of tiles including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Tiles of dark shade pigment using ordinary cement |
| 40 | Providing & fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (minimum thickness of 5 mm) of approved make in all colours,shades except burgundy,bottle green,black of any size as approved by Engineer-in-Charge in skirting,risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointinginwhite cementmixed withpigment ofmatchingshade. |
| 41 | Providing & laying Ceramic Glazed floor tiles 300x300 mm or more (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours White, Ivory, Grey, Fume Red Brown, laid on 20mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) jointing with grey cement slurry@ 3.3kg/sqm including pointing the joints with white cement and matching pigments etc. complete. |
| 42 | Providing & laying vitrified floor tile in different sizes (thickness as per manufacturer) with water absorption\"s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar as specified with coarse sand jointing with greycement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc. complete for flooring/skirting as specified |
| 43 | i)Flooring with size of Tiles 60x60Cm in cement mortar 1:4 |
| 44 | Providingandfixing18mmthickgangsawcutmirrorpolished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels. |
| 45 | iv) Granite of any colour and shade having Area of slab over 0.50 sqm |
| 46 | 25mm Thick Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade ofthe slab including rubbing and polishing complete. with baseof cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 47 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes. |
| 48 | ii) 110 mm diameter |
| 49 | Providing and laying cement plaster on surfaces with fine sand including curing etc. |
| 50 | ii)12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand) |
| 51 | Providing and laying 6mm thick cement plaster on surfaces with fine sand including curing etc. |
| 52 | i) 6mm thick plaster of mix 1:3 (1 cement: 3 fine sand) |
| 53 | 40mm Thick Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand:4 stone aggregate of 20mm nominal size) finished with a floating cement coat of neat including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 54 | Painting top of roofs with residual type petroleum bitumen of grade VG10 of approved quality at 17kg per10sqm impregnated with a coat of coarse sand at 60 cudm per 10sqm including cleaning the slab surface with brushes & finally with a piece of cloth lightly soaked in kerosene oil complete. |
| 55 | Providing and applying plaster of Paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete |
| 56 | Finishing walls with Acrylic Smooth exterior paint of required shade (2 or more coat applied @ 1.67 ltr/10 sqm over & including priming coat of exterior Primer applied @ 2.20kg/10 sqm) |
| 57 | Finishing walls with Deluxe Multi surface paint system for interiors & exteriors using Primer as per manufacturers specifications with two or more coats applied on wall @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @ 0.75 ltr / 10sqm |
| 58 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 59 | Providing and fixing water closet squatting pan (Indian type W.C.pan) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C.flushing cistern including flush pipewith manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required -White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 60 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white PVC flushing cisternincluding flush pipe with manually controlled device (handle lever),conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required: |
| 61 | i) W.C. pan with ISI marked white solid plastic seat and lid |
| 62 | Providing and fixing white vitreous china flat back or wall corner type lippedfronturinalbasinof430x260x350mmand340x410x 265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : |
| 63 | i) One urinal basin with 5 litre white P.V.C. automatic flushing cistern |
| 64 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : |
| 65 | i) White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps |
| 66 | Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 67 | Providing and fixing toilet paper holder : |
| 68 | i) C.P. brass |
| 69 | Providing and fixing soil, waste and vent pipes : |
| 70 | i) 100mm dia Sand cast iron S&S pipe as per IS: 1729. |
| 71 | Providing and fixing Chlorinated PolyvinylChloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall |
| 72 | i) 15 mm nominal outer dia Pipes |
| 73 | ii) 20 mm nominal outer dia Pipes |
| 74 | iii) 25 mm nominal outer dia Pipes |
| 75 | v) 40 mm nominal outer dia Pipes |
| 76 | Providing and fixing B class G.I. pipes complete with G.I. fittings & clamps, i/c cutting & making good the walls etc. Internal work Exposed on wall. |
| 77 | ii) 20 mm nominal outer dia Pipes |
| 78 | iii) 25 mm nominal outer dia Pipes |
| 79 | Providing and fixing brass bib cock of approved quality : |
| 80 | i) 15 mm nominal bore |
| 81 | Providing and fixing brass stop cock of approved quality : |
| 82 | i) 15 mm nominal bore |
| 83 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : |
| 84 | i) 25 mm nominal bore |
| 85 | iii) 40 mm nominal bore |
| 86 | Providing & fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : |
| 87 | i) 100mm inlet & 100mm outlet SCI S&S as per IS -3989. |
| 88 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank IS : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank |
| 89 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions,at top, bottom & sides with with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling, C.P. brass/stainless steel screws including fixingall complete as per drawing & the directions of Engineer-in-charge. (Cost of glazing or panels to be paid for separately) |
| 90 | i) Fixed Glazing with Powder coated aluminium (minimum thickness of powder coating 50 micron) sections |
| 91 | iii) For shutters of doors, windows & ventilators with Powder coated aluminium sections including providing fixing hinges/ pivots & making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 92 | Providing and fixing panelling or panelling and glazing in panelled or panelled & glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : |
| 93 | ii) 12mm thick particle board with Veneered flat pressed three layer or graded wood particle board with commercial veneering on both sides conforming to IS:3097, Grade I |
| 94 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): |
| 95 | ii) With float glass panes of 5.0 mm thickness (weight not less than 12.5kg/sqm) |
| 96 | Providingandfixingmachinemouldedaluminiumcovering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ceilings, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fasteners of 8 mm dia and 75 mm long bolt including providing aluminium washers 2 mm thick & 15 mm dia, at a staggered pitch of 200 mm centre to centre including drilling holes in the receiving surface and expandable plastic sleeves in holes etc. complete as per direction of Engineer-in-charge. |
| 97 | ii) Powder coated aluminium sheet 2.5mm thick(minimum thickness of powder coating 50 micron) |
| 98 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately). |
| 99 | Providing & fixing chromium plated brass 100mm mortice latch & lock with 6 levers & a pair of lever handles with necessary screws etc complete (best make of approved quality). |
| 100 | Providing & fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 101 | i) 250x10 mm |
| 102 | ii) 200x10 mm |
| 103 | Providing & fixingaluminium handles ISImarked anodised(anodic coating not less than grade AC10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 104 | i) 125 mm |
| 105 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 having brand logo embossed on the body/plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. |
| 106 | i) With stainless steel cover plate |
| 107 | Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc. complete as per direction of Engineer-in-Charge. |
| 108 | i) Powder coated minimum thickness 50 micron aluminium tubular handle bar |
| 109 | Providing and fixing factory made 30mm thick door shutter made of solid PVC foam profile. The styles & rails shall be of size 75mm x 30mm having wall thickness 5mm. The styles, top & bottom rails shallhave one side wall thickness of 15mm integrally extruded on the hinge side of the profile for better screw holding power. The styles and rails shall be reinforced with MS tubes of size 33mm x 17mm x 1mm painted with primer, all four corners of reinforcement to be welded or sealed. Solid PVC extruded bidding (push fit type) will be set inside the styles and rails with a cavity to receive single piece extruded 5mm PVC sheet as panel. The styles and rails shall be mitred cut and joint with help of PVC solvent cement and self tapping screws. Single piece extruded solid PVC lock rail of size 100mm x 30mm with wall thickness 5mm & 15 mm integrally extruded in the middle of the lock rail & fixed with styles with the help of PVC solvent cement & self driven self tapping screws of size 100mm x 8mm complete as per manufacturer\"s specifications and direction of Engineer-in-charge |
| 110 | i) Non Decorative finish |
| 111 | CONSTRUCTION OF SEPTIC TANK & SOAK PIT :- |
| 112 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 |
| 113 | i) All kinds of Soil |
| 114 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth |
| 115 | Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level |
| 116 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm |
| 117 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 118 | iii) Suspendedfloors,roofs,landings,balconies, access platform and Shelves (Cast in situ) |
| 119 | Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels |
| 120 | ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 |
| 121 | Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth |
| 122 | ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH |
| 123 | Providing and laying cement plaster on surfaces with fine sand including curing etc. |
| 124 | ii)12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand) |
| 125 | Providing Neat cement punning |
| 126 | Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth |
| 127 | viii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH |
| 128 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and SW drain pipe 100 mm diameter, 1.8 m long complete as per standard design with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 129 | CONST. OF BOX CULVERT WITH OPEN DRAIN: |
| 130 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 |
| 131 | i) All kinds of Soil |
| 132 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth |
| 133 | Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level |
| 134 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm |
| 135 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 136 | i) Foundations,footings,bases of columns, etc. for mass concrete |
| 137 | Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels |
| 138 | ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 |
| 139 | Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth |
| 140 | ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH |
| 141 | Structural steel work in built up sections/ framed work in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cutting,hoisting,fixing in position & applying a priming coat of approved steel primer etc. as required. |
| 142 | Providing and laying 6mm thick cement plaster on surfaces with fine sand including curing etc. |
| 143 | i) 6mm thick plaster of mix 1:3 (1 cement: 3 fine sand) |
| 144 | Providing Neat cement punning |
| 145 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes. |
| 146 | ii) 110 mm diameter |
| 147 | CONSTRUCTION OF DRIVEWAY, APPROACH & BUFFER STRIP |
| 148 | Construction of granular sub-base by providing close graded material conforming to specifications, mixing in a mechanical mixer plant at Optimum Moisture Content, carriage of mixed material by tippers to work site, for all lead and lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface & compacting with vibratory power roller to achieve the desired density, complete as per specification & direction of Engineer-in-charge. |
| 149 | i) With material confirming to grade-I (size 75 mm to .075 mm) having CBR value - 30, Thickness as desired |
| 150 | Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to .075 mm) to wet mix macadam (WMM) specifications including premixing the material with water at OMC for all leads and lifts, laying in uniform layers with mechanical paver finisher in sub-base/base course on well prepared surface and compacting with vibratory roller of 8 to 10 ton capacity to achieve the desired density, complete as per specifications & directions of Engineer-in- charge |
| 151 | Providing & laying factory made reflective type Lacquered finish Grey / coloured pre-cast cement concrete, interlocking paver block of specified grade made by block making machine wih vibratory compaction & of approved size and design / shape, shade and manufacturers and as per IOCL\"s specifications. The paver blocks shall have peripheral chamfer, with average crushing strength as per IS 15658, maximum water absorption of 2% after 10 minutes and 5% after 24 hrs. as per BS 1881, maximum dimensional deviations of +/- 2mm on length @ width and +/- 3 mm on thickness. The job includes supplying and laying a layer of 50 mm thick clean coarse sand on thoroughly compacted sub-base below the paver blocks, cutting the paver blocks wherever required with hydraulic splitter, filling in the joints at the edges of paver blocks with sand, compacting with machine vibrator to required line and level, etc. complete. (Payment for provision of edge restraints shall be made separately) |
| 152 | ii) M40 grade 80 mm thick reflective type Lacquered finish |
| 153 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 |
| 154 | i) All kinds of Soil |
| 155 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth |
| 156 | Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: |
| 157 | iii) 1:2:4(1 Cement : 2 Coarse Sand :4 Graded stone aggregate of 20mm) |
| 158 | Centeringand shutteringincludingstrutting,proppingetc. and removal of form work for: |
| 159 | i) Foundations,footings,bases of column |
| 160 | Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level |
| 161 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm |
| 162 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 163 | i) Foundations,footings,bases of columns, etc. for mass concrete |
| 164 | Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels |
| 165 | ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 |
| 166 | Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth |
| 167 | ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH |
| 168 | Providing and laying cement plaster on surfaces with fine sand including curing etc. |
| 169 | ii)12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand) |
| 170 | Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite/perlite respectively conforming to IS:2547 (Part - I & II), applied on hacked / uneven background such as bare brick/ block/ RCC work on walls & ceiling at all floors and locations, finished in smooth line and level etc. complete. Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 171 | Providing and applying plaster of Paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete |
| 172 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade with two or more coats over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 173 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level and curvature jointed with cement mortar 1:3 (1 cement:3 coarse sand) including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm) including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment) (Precast C.C. kerb stone shall be approved by Engineer-in-charge. |
| 174 | Providing and fixing of alternate black and yellow plastic road hump safety speed breaker of width minimum 350 mm and height 75mm all complete, as per specification and direction of Engineer-in-charge. |
| 175 | CONSTRUCTION OF CANOPY |
| 176 | Constructing masonry Chamber 60x60x75 cm,inside in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valves etc, with CI surface box 100mm. top diameter,160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominalsize), i/c necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement:3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S (non modular) bricks of class designation 7.5 |
| 177 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty |
| 178 | ii) 150 mm dia. R.C.C. pipe |
| 179 | iv) 300 mm dia. R.C.C. pipe |
| 180 | Excavating trenches of required width for pipes, cables etc including excavation for sockets & dressing of sides, ramming of bottoms,depth upto 1.5m including taking out excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing surplus excavated soil as directed, within or outside site at unobjectionable place in all kinds of soil |
| 181 | iv) Pipes, Cable etc. > 80mm < 300m dia |
| 182 | Providing and fixing Klippon Galvalume steel profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) of Cold rolled steel confirming to IS:513-2008 of base metal thickness 0.50 mm, having Yield Stress of Min. 275 MPa. Steel surface shall have hot dip metallic coating of Al-Zinc alloy comprising 55% Alluminium, 43.5% Zinc and 1.5% Silicon as per the ASTM-A792M, with total mass of coating on both sides shall be 150 gms/sqm. The steel shall have organic coating with Silicon Modified Polyester (SMP) /Super Durable Polyester (SDP) paint on continuous coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns SMP /SDP paint over 5-7 microns epoxy primer) and back side 8-10 Microns SMP/SDP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.58 MM. Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation and should be supplied in single length up to 6m or as desired by Engineer-in-charge. |
| 183 | ii) Plain Sheet for Ridges (500 - 600mm). |
| 184 | iii) Plain sheet for Flashings/ Aprons (Upto 600 mm) |
| 185 | iv) Plain Sheet for Gutter (600 mm over all girth) |
| 186 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes. |
| 187 | ii) 110 mm diameter |
| 188 | Providing & fixing BARE Klippon Galvalume steel profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) ofbare metal thickness 0.55 mm as per ASTM A446 having yield stress of 275mpa, surface shall have hot dip metallic coating of Aluminium Zinc alloy comprising of 55% aluminium,43.5% zinc & 1.5% silicon, Sheet shall have protective guard film of25 microns minimum to avoid scratches while transportation & should be supplied in single length up to 6m or as desired by Engineer-in-charge. |
| 189 | Providing and fixing 150F/200F flush panel,(pre-coated steel) False Ceiling made of Cold rolled steel sheet conforming to IS 513, having minimum yield stress and tensile stress as 240 Mpa & 300 Mpa respectively. Base metal thickness for ceiling panel and Carriers shall be 0.45mm and 0.55mm respectively. The steel surface shall have hot dip metallic coated with Zinc coating (galvanizing) as per IS277, with total mass of coating on both sides shall be 120 gms/sqm. The steel shall have organic coating with Regular Modified Polyester (RMP) paint on continuous coil coating line. The thickness of coating on top side shall be 20-25 Microns (i.e. 15-18 microns RMP paint, over 5-7 microns epoxy primer) and back side 8-10 Microns RMP paint over epoxy primer. Total Coated Thickness (TCT) shall be 0.50 MM for Ceiling panel and 0.60 MM for Carrier. Sheet shall have protective Sheet shall have protective guard film of thickness of 25 microns minimum to avoid scratches while transportation & should be supplied in single length up to 6m (for panel) and up to 5m (for carrier) or as desired by Engineer-in-charge. The ceiling panel shall be clipped into carriers which are suspended from steel trusses/purlins with the help of GI suspension angle of size 25x25x0.5mm thick by means of rigid suspension system meant for exterior. The longitudinal joints of two panels shall be butt joined with a special type of panel splice to be fixed from inner side. The carrier will be joined with carrier splices maintaining a module of 150 mm. The spans shall not exceed as recommended and manufacturer recommendations shall be followed on installation procedure. |
| 190 | Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: |
| 191 | CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying ofXLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items |
| 192 | iv) 3 Core x 2.5 sq. mm Copper Cable FRLS |
| 193 | CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compressoncable glands, crimping type lugs and allied jointing materials, etc. all complete as per specificationand direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. |
| 194 | vii) 3 Core x 2.5 sq. mm |
| 195 | Providing, fixing, testing and commissioning of FLPjunction box of approved make for cable connection/ jointing. |
| 196 | i) For cables 2.5 to 4 sqmm XLPE / AYFY |
| 197 | Supply and fixing of Linear Recessed mounted LED (Light Emitting Diode) Light fittings of size 2400mm and 80 Watt, having IP 65 protection class with Pressure Die Cast Aluminium housing and with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer-in-charge. High Efficiency Translucence(HET) diffuser. Colour Rendering Index CRI>80, Temp-0 to 45 Deg C, Driver efficiency>85%, THD < 10%, CCT- 6500 K Powerfactor>0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 140-270V AC and Safety Extra Low Voltage Safe level < 60V DC as per IEC standard, Luminaire lumen≥ 2100lm.Each lot of Fittings shall have serial numbers & accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc |
| 198 | CONSTRUCTION OF DOUBLE SIDED HOARDING : |
| 199 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 |
| 200 | i) All kinds of Soil |
| 201 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m |
| 202 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth |
| 203 | Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level: |
| 204 | ii) 1:1½:3(1 Cement :1½ Coarse Sand: 2 Graded stone aggregate of 20mm) |
| 205 | Providing and laying cement plaster on surfaces with fine sand including curing etc. |
| 206 | ii)12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand) |
| 207 | Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: |
| 208 | Painting on G.S. sheet with synthetic enamel paint of approved brand & manufacture of required colour to give an even shade, 2 or more coats,including a coat of approved steel primer but excluding a coat of mordant solution |
| 209 | Centeringand shutteringincludingstrutting,proppingetc. and removal of form work for: |
| 210 | i) Foundations,footings,bases of column |
| 211 | Supply and fixing of 30 W LED (Light Emitting Diode) light fixture with fittings and accessories for hoarding light purposes having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. |
| 212 | CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compressoncable glands, crimping type lugs and allied jointing materials, etc. all complete as per specificationand direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. |
| 213 | vi) 3 Core x 1.5 sq. mm. |
| 214 | vii) 3 Core x 2.5 sq. mm |
| 215 | CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying ofXLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items |
| 216 | iv) 3 Core x 2.5 sq. mm Copper Cable FRLS |
| 217 | i) 2 Core x 1.5 sq. mm. (copper) |
| 218 | Supply & drawing/laying, jointing, connecting, testing and commissioning ofearth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following : |
| 219 | v) 25 x 3 mm GI strip |
| 220 | Supply & fixing of weatherproof125 mm dia junction box (4 way entry) of BALIGA/CEAG-FCG/FLEXPRO/FEPL makeincluding clamping arrangement, all complete as per specification & direction of Engineer In-charge. |
| 221 | PROVISION OF ELECTRIC PANEL & ALLIED ELECTRICAL WORKS |
| 222 | PANEL BOARDS AND DISTRIBUTION BOARDS Supply, installation, testing and commissioning of cubicle type power and motor control centre panel fabricated out of 14 SWG sheet steel undergone 7 tank process,dust & vermin proof, floor mounting type, suitable for indoor use having cable entry from the bottom and having following specific components complete, control wiring etc. as per enclosed standard drawing. Any other components/hardware required to complete the panels but not mentioned here shall also be provided. Note: Both incomers should have mechanical interlock for proper & safe operation. The MCCB used for incomer feeder shall have short circuit, overload and earthfault protection and also shunt coil for ESD operation. The Bus Bar support shall be DMC/ SMC/Epoxy moulded. All equipment/components shall be mounted logically to have free access for maintenance, tightening of connections & visual inspection. All the metering equipment shall be Digital & mounted on the panel and size of meter shall be 96 mm x 96 mm. The Bus Bar shall be provided with heat shrunk PVC sleeves & all power terminals shall be stud type with properly shrouding to avoid accidental contact. Neoprene type gasket shall be provided at the doorof the panel. The enclosure of the Panel shall have IP52 degree of protection. 2 Nos earth terminal shall be provided at the Panel frame with extension link for earthing connections. Painting:The under surface shall be prepared by applying a coat of phosphate paint and coat of yellow zinc chromate primer. The under surface shall be made free from all imperfections before undertaking the finishing coat. After preparation of the under surface, the switchboard shall be spray painted with two coats of epoxy based final paint or shall be powder coated. Colour shade of final paint shall be RAL 7032. |
| 223 | Medium RO, Standard drawing No. ENG/IOCL/PDIL-2. List of Componets are: (a) 1 No. MCCB (3P+N) of 100 A, 35 KA with O/L, E/F & S/C Releases for incomer from Electricity Board (b) AC Digital Voltmeter (0-500V) with built in selector switch for incomer from Electricty Board (c) AC Digital Ammeter (0-100A) with built in selector switch for incomer from Electricity Board (d) 1 No. FP, On Load, 100 A, Manually Operated Change over switch suitable for connection of Mains supply and 30 KVA DG Set /5 KW Solar system with required No. of MCCB (100 A,35 KA,3P+N) for change over between Mains supply and DG Set /Solar Supply along with 2 Nos 6A , SP, Control MCB with Indicating lamps. (e) 1 No. MCCB (3P+N) of 100A, 35 KA with UV coilO/L , E/F & S/C Releases for incomer from Electricity Board/DG Set/Solar Supply & 1 No 6A , SP, Control MCB with 3 Nos LED Type (RYB) Indicating lamps (f) 3 Nos 100/5 A CL1 10VA Current Transformers ; PT (50 VA) along with 2 A control fuse link and 1 No. 6A , SP, Control MCB (g) 1 No DP MCB of 40 A, 10 KAfor supply of essential loads (h) 1 No Single Phase Contactor(3NO+3NC) for supply to essential loads (i) 1 No MCB DB Hosuing 6 Nos , 16 A, 10 KA DP MCB as outgoings for essential loads (j) 415 V, TP & N, 125 A, Al Bus Bar (k) 4 Nos MCB (3P+N) of 40 A,10 KA for supply of outgoing feeders 1-4 (l) 9 Nos DP MCB of 10 A, 10 KA in Outgoing Feeder -1 (m) 6 Nos DP MCB of 16 A, 10 KA & 3 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-2 (n) 3 Nos DP MCB of 16 A, 10 KA & 6 Nos DP MCB of 20 A, 10 KA in outgoing Feeder-3 (o) 8 Nos TP MCB of 16 A, 10 KA & 1 Nos TP MCB of 25 A, 10 KA in outgoing Feeder-4 (p) Provision for Termination of Solar Power (Up to 10 KW) Incomer to Essential DB in Panel as per requirement ofIOCL. |
| 224 | CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying ofXLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items |
| 225 | xviii) 3.5 Core x 50 sq. mm Aluminium Cable FRLS |
| 226 | PROVIDING INTERNAL WIRING |
| 227 | i) Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. |
| 228 | Providing following point wiring with standard wire/ cable, plug, fittings, with suitable sockets, suitable GI box with front plate etc. complete, to include circuits from distribution boards to individual point boards, suitable PVC casing capping and required accessories pulling of wires, etc. complete. |
| 229 | i) Supplying and drawing following 2 pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 230 | Supplying, drawing sub-main/power wiring with PVC insulated Copper 1100 V grade FRLS type through heavy duty rigid PVC conduit either on wall or in concealed. The job include terminations at both ends through proper jointing materials all complete for the following Make of Insulated wires shall be as per approved make |
| 231 | i) 2 x 1.5 sq mm + 1 x 1.5 sq mm earth wire |
| 232 | ii) 2 x 2.5 sq mm + 1 x 2.5 sq mm earth wire |
| 233 | iii) 2 x 4 sq mm + 1 x 4 sq mm earth wire |
| 234 | iv) 2 x 6 sq mm + 1 x 6 sq mm earth wire |
| 235 | SWITCHES, FUSES, MCBS, ELCBS ETC Supply and fixing of Modular switch frame with inner and outer face plates and accessories as per following details of approved includingflush metal boxes/surface mounting boxes, plates, etc. all complete as per manufacturer\"s specification and direction of Engineer In-charge. |
| 236 | iii) 4 module frame |
| 237 | viii) 15 A Modular switch |
| 238 | xi) 2 Pin Telephone Modular Socket |
| 239 | xii) Fan Regulator of stepped modular type |
| 240 | Supply & fixing of 300mA RCCB of approved Make of following ratings: |
| 241 | v) 4 poles, 63A |
| 242 | Supplying & fixing of approved make 4 pole change over switch in steel sheet enclosure with side handle operation onload type grouting in C.C. Complete as per direction of Engineer-In-Charge. |
| 243 | iii) 100 Amps., 4 Pole |
| 244 | Supply and Installation of Flame Proof ESD Push Button |
| 245 | MCB DISTRIBUTION BOARD INCLUSIVE OF 3- PHASE MCB Supply & fixing of MCB Distribution Board double door type inclusive ofMCB, Three Phase, as per Approved Make of following types: (MCB - 10KA Breaking Capacity) |
| 246 | i) S/E 4 way DB with 63A FPRCBO, 300 mA sensitivity as incoming - 1No.& 6 to 16A SP as outgoing - 4 Nos. for each phase. |
| 247 | Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 18 Watts with fittings and accessories, having IP65 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. |
| 248 | Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 8 Watts with fittings and accessories, having IP20 protection class with CRCA/PC/Aluminium Extrusion housing & with UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer in charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall range from 5700 Kelvin (5665 K +/- 355 K) to 6500 Kelvin, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 80 for indoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 95 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 2kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. |
| 249 | CEILING FANS Supply & fixing of ceiling fan for inside of the sales building of following type: |
| 250 | iii) 1200 mm sweep |
| 251 | EXHAUST FANS Supply and fixing of exhaust fan including electrical wiring all shall be with per specification and direction of site In charge. The fans shall be with louvers / shutters. (The job does notinclude making suitable cut out in thewall for fixing the fan). |
| 252 | ii) 9\" dia light duty, make Khaitan or equivalent |
| 253 | Air compressor Supply and installation of horizontal air compressor assembly with delivery pressure of 12 kg/sq cm equipped with pressure gauge, non- return/safety/drain/delivery valves, automatic cut-off switch and suitable electrical connections & all standard accessories, including civil works: |
| 254 | iii) Horizontal air compressor Assembly of 5 HP (160-220 LITRES) including civil works |
| 255 | Tyre Inflator Supply & installation of Digital tyre inflator which is microprocessor based, automatic air pressure controller with solenoid controlled nozzle for automatic fill and release functions. Complete with weather proof cabinet, 3 digit LED displays with backlight illuminations i.e. one for actual tyre pressure and another for set pressure. Air filter, remote controller, cables, PVC hose pipe and working pressure upto 10bar (Excluding civil work for foundation,etc.) |
| 256 | Supplying and fixing of MV Lightining Arrestor horn gap type as required |
| 257 | Supply of Galvanised Fire buckets of 9 litre capacity, painted white inside and red outside with letters \"fire\" in black, conforming to IS 2546-1974. |
| 258 | Supplying Fire bucket stand- 4 buckets hanging arrangement 1 meter height, made of 50x50x6mm angle frame, painted with 2 coats of primer and 2 coats of Red, synthetic enamel paint. |
| 259 | Supplying and fixing of 4.5kg CO2 fire extinguisher of approved make Conforming to IS 15683, portable high pressure type. Body seamless Manganese Steel, ISI marked conforming to IS 7285, discharge valve conforming to IS 324,polyethylene flat discharge horn with diffuser,1m wire braded rubber hose, powder coated wall mounting mild steel bracket,stainless steel safety pin of SS 316 grade, CO2 gas with 99.5% purity. Extinguisher shall have anti corrosive treatment of phosphating by hot dipping process to thickness not less than 0.012mm both internally and externally. Epoxy polyester powder coating of minimum 50 micron to all metallic external parts with two bands of yellow colored fluorescent adhesive tape of minimum 20mm thickness of body. Finish of the paint to be PO red as per shade 538 ofIS:5 |
| 260 | Supplying and fixing of 9kg DCP portable,cartridge type Fire extinguisher of approved make,Conforming to IS15683:2006,Body Carbon Steel as per IS:513,EDD grade with no vertical weld joint on the body Neck ring of seamless mild steel tube conforming to IS 1239 part-1, Valve assembly conforming to SS 316 grade or forged brass as per IS 6912 grade FLB, Inlet and outlet siphon tubes of SS 316 grade or of brass as per IS 407, Discharge nozzle of SS 316 grade of forgedbrass as per IS 6912, 500mm long discharge hose of EDPM rubber, powder coated wall mounting mild steel bracket,stainless steel safety Pin of SS 316 grade, Dry Chemical powder ( potassium bi-carbonate & Minimum 90% of the total chemical), ISI marked CO2 Gas cartridge of 200 gms, dia of the body 175mm +/- 10mm & overall height less than 650mm.Extinguisher shall have anticorrosive treatment of phosphating by hot dipping process to thickness not less than 0.012mm both internally & externally. Epoxy polyester powder coating of minimum 50 micron to all metallic external parts with two bands of yellow colored fluorescent adhesive tape of minimum 20mm thickness of body. Finish of the paint to be PO red as per shade 538 ofIS:5 |
| 261 | iii) Supply and fixing of shock treatment chart in English, Hindi & local language framed in glass framework. |
| 262 | Providing & fixing flexible copper cable PVC insulated of 16sqmm for connecting the earth grid/earth strip with the crocodile clip i/c cost of 1 no. crocodile clip (for tanker earthing & other job) |
| 263 | Supplying & Fixing of following items for electrical safety in switch rooms/DG rooms etc |
| 264 | i) Electrical insulating mats made of PVC Elastomer 3mm Thick & 1 mtr wide near swichboards, etc as per direction of Engineer In charge. Mat should conform to IS 15652 Class A - suitable for safe working voltage of upto 33 kV. Test certificate to be provided with supply. Mat\"s top Surface should be Antiskid Dotted & Bottom Surface should be Textured for Floor Grip. Mat\"s top Surface should be Antiskid Dotted & Bottom Surface should be Textured for Floor Grip. |
| 265 | iv) 11 KV grade hand gloves, ISI mark |
| 266 | Formation of lighting protection arrangement with supply of 1.0 M height spike and erection at top most portion of structure/building and connecting the same to earthpit by 40x6mm GI strip (excluding supply and laying of GI strip) |
| 267 | SUPPLY AND INSTALLATION OF YARD LIGHTS : |
| 268 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Light Duty |
| 269 | ii) 150 mm dia. R.C.C. pipe |
| 270 | Excavating trenches of required width for pipes, cables etc including excavation for sockets & dressing of sides, ramming of bottoms,depth upto 1.5m including taking out excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing surplus excavated soil as directed, within or outside site at unobjectionable place in all kinds of soil |
| 271 | iv) Pipes, Cable etc. > 80mm < 300m dia |
| 272 | Constructing masonry Chamber 60x60x75 cm,inside in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valves etc, with CI surface box 100mm. top diameter,160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominalsize), i/c necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement:3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S (non modular) bricks of class designation 7.5 |
| 273 | CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying ofXLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items |
| 274 | iv) 3 Core x 2.5 sq. mm Copper Cable FRLS |
| 275 | xviii) 3.5 Core x 50 sq. mm Aluminium Cable FRLS |
| 276 | CABLE TERMINATION GLANDS NON-FLP HEAVY DUTY DOUBLE COMPRESSION Cable Termination (NON FLP): Providing termination of 1.1 kV grade armoured cable for the following sizes including supply of NON FLP heavy duty Double Compressoncable glands, crimping type lugs and allied jointing materials, etc. all complete as per specificationand direction of Engineer In-charge. Glands and lugs shall be of approved make. Copper lugs for copper cables and aluminium lugs for aluminium cables shall be used. |
| 277 | vii) 3 Core x 2.5 sq. mm |
| 278 | Supply & drawing/laying, jointing, connecting, testing and commissioning ofearth strip/copper strip/GI wire for earthing and lightning protection under or aboveground complete as per specification for the following : |
| 279 | v) 25 x 3 mm GI strip |
| 280 | OCTAGONAL POLES Supply & Fixing of Octagonal Poles of following type (Civil job shall be paid separatly) : |
| 281 | iii) S/E of 5 Meter high galvanised Octagonal pole with top 60mm(A/F), bottom 130mm (A/F) made up of 3 mm thick plate having a base plate of size 210 x 210 x 12 with single arm 1500mm long bracket arm made up of 48 O.D. pipe with EN 8 grade galvanised foundation bolts and anchor plate on suitable concrete foundation as per standard drawings enclosed herein(Civil & Electrical works shall be paid separately) having fixing arrangement for mounting 2 Nos. of 250W Metal halide luminaries (on opposite sides) |
| 282 | Supply, fitting, fixing of arm bracket, tubular type, 38mm/50mm dia on pole including painting, all complete. |
| 283 | ii) S/EArm \" Y \" bracket 38/50mm dia on pole, as per specifications and direction of Engineer in charge |
| 284 | Supplying & drawing inside the poles 3 core 2.5 sq.mm PVC insulated flexible copper conductor, fixing of junction box at the pole base (excluding supply of JB), making all connections on both ends, all complete as per specification and direction of Engineer In-charge. |
| 285 | i) \"Y\" Pole |
| 286 | ii) \"L\" Pole |
| 287 | Supply and fixing of 100 W LED (Light Emitting Diode) light fixture with fittings and accessories for Yard lighting purpose having IP66 protection class with Pressure Die Cast LM6/ADC12/LM24 housing and with toughened glass or UV stabilized polycarbonate cover type of approved make or equivalent as per direction of Engineer-in-charge. The LED driver shall have an in-built high voltage cutoff >= 290 V with power factor of complete fitting greater than 0.90. CCT (Correlated Colour temperature) shall be in the range of 5665 K +/- 355 K as per ANSI standard C78.377, CRI (Colour rendering index) should include all colour range from R1 to R15 and > 70 for outdoor luminaire. LED efficacy shall be greater than 140 lumens/watt @ 350mA drive current. The minimum system lumen efficacy of the luminaire shall be 100 Lumens per Watt. The Surge Protection Device (SPD) should be series type with fail safe, surge protection for minimum 3kV shall be provided. Supply of complete fitting with all accessories as per specification attached and as per direction of engineer in charge. Each lot of fittings shall accompany test certificates LM79/ IS:16106 and reference/ batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of minimum 60 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminaire etc. |
| 288 | i) All kinds of Soil |
| 289 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth |
| 290 | Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level |
| 291 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm |
| 292 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 293 | i) Foundations,footings,bases of columns, etc. for mass concrete |
| 294 | Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels |
| 295 | ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 |
| 296 | CONSTRUCTION OF MONOLITH FOUNDATION |
| 297 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed. Extra for levelling and neatly dressing of disposed soil completely to be paid separately as per item no. MH1CN00600 |
| 298 | i) All kinds of Soil |
| 299 | Extra for every additional lift of 1.5m or part thereof in excavation or banking excavated or stacked materials in all kinds of soil |
| 300 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m |
| 301 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation levelling & dressing & finishing the top smooth |
| 302 | Providing and laying inposition specified grade ofreinforced cement concreteexcludingthecostofcentering,shuttering, finishing and reinforcement - All work up to plinth level |
| 303 | ii) RCC 1 Cement :1½ Coarse Sand: 3 Graded Stone Aggregate 20mm |
| 304 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 305 | i) Foundations,footings,bases of columns, etc. for mass concrete |
| 306 | Supply of Steel reinforcement for R.C.C. including straightening, cutting, bending, placing in position and binding all complete at all levels |
| 307 | ii) Thermo Mechanically Treated Bars of Fe- 500D grade or more, conforming to IS1786 |
| 308 | Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth |
| 309 | viii) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement : 4 coarse sand) IN FOUNDATION AND PLINTH |
| 310 | Providingandfixing18mmthickgangsawcutmirrorpolished premoulded and prepolished, machine cut for kitchen platforms, vanity counters, sills, facias, Pump Island & similar locations of required size, approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding & polishing to edge to give high gloss finish etc. complete at all levels. |
| 311 | iii) Granite of any colour and shade having Area of slab upto 0.50 sqm |
| 312 | Supplying and fixing of 10mm thick mirror polished black granite tiles for pump island edges etc. over 12mm thick CM 1:4 including cost of all materials and labour etc. complete. |
| 313 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion, Single socketed pipes. |
| 314 | ii) 110 mm diameter |
| 315 | Providing and laying cement plaster on surfaces with fine sand including curing etc. |
| 316 | i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand) |
| 317 | Supplying and fixing MS foundation bolts with necessary GI nuts and washers of specified sizes,all conforming to relevant Indian Standards and as approved by Engineer-in-charge : |
| 318 | v) 25mm dia x 1000mm long with 100 mm dia x 8 mm thick plate |
| 319 | CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying ofXLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items |
| 320 | iv) 3 Core x 2.5 sq. mm Copper Cable FRLS |
| 321 | CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying ofXLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items |
| 322 | vii) 3 Core x 2.5 sq. mm |
| 323 | Supply & fixing of weatherproof125 mm dia junction box (4 way entry) of BALIGA/CEAG-FCG/FLEXPRO/FEPL makeincluding clamping arrangement, all complete as per specification & direction of Engineer In-charge. |