}

General-Project 338 Kodiyathur Panchayath - Installation Of Low Mast Light-Installation Of Low Mast-General Electrical Work, Kozhikode-Kerala

Grama Panchayat has published General-Project 338 Kodiyathur Panchayath - Installation Of Low Mast Light-Installation Of Low Mast-General Electrical Work. Submission Date for this Tender is 12-03-2025. Street Lighting Tenders in Kozhikode Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

48106194
General-Project 338 Kodiyathur Panchayath - Installation Of Low Mast Light-Installation Of Low Mast-General Electrical Work
Open Tender
Indian
Kerala
Kozhikode
12-03-2025

Tender Documents

Tender Details

GENERAL-Project 338 Kodiyathur Panchayath - Installation of Low Mast Light-Installation of Low Mast-General Electrical Work Electrical , 90.12.10.2:Supply & Laying Of Dwc Pipe In Ordinary Soil 0.75M Below Ground Level Including Excavation50/38 Mm Or Nearest Size , 90.12.5.2:Supply & Laying Of One Number Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable Of 1.1Kv Grade Of The Following Sizes In The Existing Rcc/ Hume / Stone Ware/ Gi/ Dwc Pipe As Required.2 Core 6 Sq Mm , 90.15.1.1:Supply Installation Testing And Commissioning Of Octogaonal Pole Made Of Hot Dip Galvanised Gi Sheet 70Mm Top Diameter. 130Mm Bottom Diameter Thickness 3Mm Base Plate Dimensions Of 200X200x16mm Suitable For Windspeed As Per Is 875 Part Iii Fixed Head Frame Including Round Arm Luminary Carriage Suitable To Install 4/6 Nos Luminaries In Symmetrical Arrangement Including Connector Foundation Bolt 4 Nos Existing Rcc Foundation And Junction Box Etc, Complete 8 Meters , 90.16.1.3:Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg) , 90.16.5.3:Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.3.15 Mm (10 Swg) , 9.1.1:Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.2 X 6 Sq. Mm (19Mm) , 1.14.2:Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2x 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire , 1.21.1:Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.20 Mm , 1.21.3:Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.32 Mm , 14.1:Excavation For Foundation In Soft Soil Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 Metres. , 14.10:Providing And Laying In Position Reinforced Cement Concrete 1 :2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) In Foundation Of Pump, Dg Set Etc. Including Form Work Etc. As Required (Excluding Reinforcement). , 14.12:Providing 15Mm Thick Cement Plaster Of Mix 1:4(1 Cement: 4 Fine Sand) At All Levels , 14.8:Providing And Laying In Position Cement Concrete 1 :3:6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) In Foundation Of Pump, Dg Set Etc. Including Form Work Etc. As Required. , 2.10.3:Supplying And Fixing 5 Amps To 32 Amps Rating, 240/415 Volts, &Quot;C&Quot; Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Double Pole , 2.12.1:Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps , 2.14.1:Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral), 240 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current Upto 300 Milliamperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.25 Amps , 5.3:Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. (But Without Charcoal/ Coke And Salt ) As Required. , 5.9:Supplying And Laying 25 Mm X 5 Mm G.I Strip At 0.50 Metre Below Ground As Strip Earth Electrode, Including Connection/ Terminating With G.I. Nut, Bolt, Spring, Washer Etc. As Required.(Jointing Shall Be Done By Overlapping And With 2 Sets Of G.I. Nut Bolt & Spring Washer Spaced At 50Mm) , Od456349/2024-2025:Preparing And Submitting The Relevant Documents In Kseb Office Including Sketches And Necessary Drawings, Filling The Required Proforma For Service Connection Application, Collecting The Various Documents And After Obtaining The Signature From The Applicant. Remitting The Application Fee And The Required Amount . The Required Amount May Be Collected From Panchayath/Municipal Office And Hand Over The Receipt Received From Kseb To The Authorities. , Od456350/2024-2025:Supply And Installation Of Dust And Vermin Proof , Single Phase Syntax Meter Board(Gsmb 3525)To Fix Kseb Meters, Fuse Units Cts Etc As Required Invludig Fixing On Wall,Making Good The Damages Colorpainting Etr... As Required , Od456351/2024-2025:Supplying And Fixing 32A , 2 Way Neutral Links Mounted On Dmc/Smmc Basewith Connections, In The Existing Meter Board , Od456353/2024-2025:Supplylaying And Binding Ms Tor Steel Of Various Sizes For Rcc Works , Od456354/2024-2025:Providing And Fixing 2 X 25 X 3Mm Gi Strip Test Joint For Earthing System , 90.15.4.7:Supply Conveyance, Installation, Testing And Commissioning Of 100W Led Flood Light Output Greater Than 105Lumen/W 4000-6000 K With Ip 66 Protection Led Chip Make Cree/Lumilled/Nichea With Power Factor Greater Than 0.95 At Full Load, Internal Surge Protection Up To 8 Kv,And Aluminium Pressure Die-Cast Powder Coated Housing, Acrylic Cover Complete With Thd Less Than 10%, Power Factor Greater Than 0.98, Rohs Compliant, Duly Wired Up For Use On 230 V Ac Supply. Driver Compartment Should Be Seperatly Accessible For Maintenance (Lm 79&80 Certificates From Nabl Accredited Third Party Lab To Be Produced Mentioning Chip Manufacturer) , Od462854/2024-2025:Supply And Fixing 32A,Hrc Fuse With 32A Fuse Link With Connections, In The Existing Meter Board

Key Value

Document Fees
INR 555 /-
EMD
INR 2605.0 /-
Tender Value
INR 1.04 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail